Diana K. Tazhetdinova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Diana K. Tazhetdinova has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Kirill A. Tomyshev
Kotelnikov Institute of Radioengineering and Electronics of RAS, Moscow, Russia
3 shared publications - Oleg V. Butov
Kotelnikov Institute of Radioengineering and Electronics of RAS, Moscow 125009, Russia
3 shared publications - Egor Manuylovich
Aston University
2 shared publications E.I. Dolzhenko
1 shared publicationE.S. Manuilovich
1 shared publicationK.A. Tomyshev
1 shared publication
Latest Publications
- 1 June 2020
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 308
High-precision data analysis for TFBG-assisted refractometer
- 1 June 2020
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 308
High-precision data analysis for TFBG-assisted refractometer
- 11 December 2018
- Published by Wiley in Physica Status Solidi (a)
- Vol. 216 (3)
Ultrastable Combined Planar‐Fiber Plasmon Sensor
A new design for a hybrid fiber‐planar refractive index sensor based on the surface plasmon resonance effect is presented. The key element of the design is a thin layer of gold covering a tilted fiber Bragg grating. In the study, a specially developed microfluidic chip is used to perform measurements directly in the flow of the investigated liquid. Rigidly mounting the sensor to the base of the fluid chip is proposed. The presented experimental data demonstrate the high stability of the sensor readings and the low noise level during measurements in a liquid flow. The proposed construction is a promising decision for application in compact immunoassay systems based on microfluidic technologies.
- 11 December 2018
- Published by Wiley in Physica Status Solidi (a)
- Vol. 216 (3)
Ultrastable Combined Planar‐Fiber Plasmon Sensor
A new design for a hybrid fiber‐planar refractive index sensor based on the surface plasmon resonance effect is presented. The key element of the design is a thin layer of gold covering a tilted fiber Bragg grating. In the study, a specially developed microfluidic chip is used to perform measurements directly in the flow of the investigated liquid. Rigidly mounting the sensor to the base of the fluid chip is proposed. The presented experimental data demonstrate the high stability of the sensor readings and the low noise level during measurements in a liquid flow. The proposed construction is a promising decision for application in compact immunoassay systems based on microfluidic technologies.
- 19 September 2018
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 124 (11) , 113106
High-resolution fiber optic surface plasmon resonance sensor for biomedical applications
This paper presents a modified design of a high-resolution fiber optic sensor that operates on the surface plasmon resonance effect. The sensor is based on the well-known method of generating surface plasmons with the help of an inscribed tilted fiber Bragg grating that excites the cladding modes. Because the original design solution used a polarizing fiber, it was possible to significantly improve the stability of the sensor readings. The specialized mathematical apparatus was used to determine the surface plasmon resonance spectral position. It was experimentally shown that the limit of detection to the refractive index of such a sensor is 2 × 10−6 refractive index units. The sensor's response to the investigated medium temperature change is presented and analyzed. The high resolution of the sensor in detecting protein molecules was demonstrated. Such sensors open wide perspectives for their application in real high-sensitivity sensor systems as biosensors for immune analysis in medical diagnostics.
- 19 September 2018
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 124 (11) , 113106
High-resolution fiber optic surface plasmon resonance sensor for biomedical applications
This paper presents a modified design of a high-resolution fiber optic sensor that operates on the surface plasmon resonance effect. The sensor is based on the well-known method of generating surface plasmons with the help of an inscribed tilted fiber Bragg grating that excites the cladding modes. Because the original design solution used a polarizing fiber, it was possible to significantly improve the stability of the sensor readings. The specialized mathematical apparatus was used to determine the surface plasmon resonance spectral position. It was experimentally shown that the limit of detection to the refractive index of such a sensor is 2 × 10−6 refractive index units. The sensor's response to the investigated medium temperature change is presented and analyzed. The high resolution of the sensor in detecting protein molecules was demonstrated. Such sensors open wide perspectives for their application in real high-sensitivity sensor systems as biosensors for immune analysis in medical diagnostics.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 53-56
High-resolution fiber plasmon sensor
A new fiber optic plasmon refractive index sensor was designed. On water solutions a resolution of 2*10-6 refractive index units (RIU) was demonstrated. It was shown that a reliable detection of low concentrations of proteins in solutions is possible. Myoglobin in acetate buffer at a concentration of 500ng/ml was detected.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 53-56
High-resolution fiber plasmon sensor
A new fiber optic plasmon refractive index sensor was designed. On water solutions a resolution of 2*10-6 refractive index units (RIU) was demonstrated. It was shown that a reliable detection of low concentrations of proteins in solutions is possible. Myoglobin in acetate buffer at a concentration of 500ng/ml was detected.