Gad Shani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Gad Shani has a total of 109 co-authors. Here are the top co-authors by number of shared publications:
A. Tsechanski
Ben Gurion University of the Negev, Department of Nuclear Engineering P.O. Box 653, Beer Sheva 84120, Israel
10 shared publicationsR. Ofek
Ben Gurion University of the Negev, Department of Nuclear Engineering P.O. Box 653, Beer Sheva 84120, Israel
6 shared publicationsA. Goldfeld
Ben Gurion University of the Negev, Department of Nuclear Engineering P.O. Box 653, Beer Sheva 84120, Israel
5 shared publicationsA. Haccoun
Department of Nuclear Engineering, Ben-Gurion University of the Negev P.O.B. 653, Beer Sheva 84120, Israel
4 shared publicationsA. Kushelevsky
Department of Nuclear Engineering, Ben-Gurion University of the Negev P.O.B. 653, Beer Sheva 84120, Israel
3 shared publicationsF. J. Litterst
Institut für Metallphysik, Technische Universität Braunschweig, D-3000 Braunschweig, West Germany
3 shared publications
Latest Publications
- Open Access
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S371
PO-0963: Thulium-170 for Brachytherapy
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S371
Open AccessPO-0963: Thulium-170 for Brachytherapy
- 1 March 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (3) , 334-339
Application of spherical micro diodes for brachytherapy dosimetry
- 1 March 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (3) , 334-339
Application of spherical micro diodes for brachytherapy dosimetry
- 16 April 2010
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 86 (5) , 390-399
Effect of 99 GHz continuous millimeter wave electro-magnetic radiation onE. coliviability and metabolic activity
Purpose: To investigate time exposure dependence of continuous millimeter wave (CW) 99 GHz radiation on Escherichia coli bacterial cell viability and metabolic activity. Materials and methods: Suspensions of E. coli bacterial cells with an optical density of OD660nm = 0.1 were used for viability tests and OD660nm = 1.0 for metabolic activity tests. These suspensions were exposed to 99 GHz CW electromagnetic radiation, generated by a Backward Wave Oscillator (BWO) tube base instrument with a horn antenna at the BWO exit, to obtain an almost ideal Gaussian beam. Calculations of the Gaussian beam show that a power of 0.2 mW/cm2 was obtained at the bacterial plane. Results: The experimental results show that 1 hour of exposure to 99 GHz CW electromagnetic radiation had no effect on E. coli viability and colony characterisation. In 19 h of radiation, the number of colonies forming units was half order of magnitude higher than the sham-exposed and the control. However, 19 h of exposure did not affect the E. coli metabolic activity. Conclusions: Exposure of E. coli to millimeter wave (MW) CW 99 GHz radiation for a short period did not affect the viability of E. coli bacterial cells. However, exposure for 19 h caused a slight proliferation but did not influence the metabolic activities of about 90 biochemical reactions that were examined. Hence, we assume that the slight proliferation (half order of magnitude) after 19 h of exposure dose not have a biological meaning.
- 16 April 2010
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 86 (5) , 390-399
Effect of 99 GHz continuous millimeter wave electro-magnetic radiation onE. coliviability and metabolic activity
Purpose: To investigate time exposure dependence of continuous millimeter wave (CW) 99 GHz radiation on Escherichia coli bacterial cell viability and metabolic activity. Materials and methods: Suspensions of E. coli bacterial cells with an optical density of OD660nm = 0.1 were used for viability tests and OD660nm = 1.0 for metabolic activity tests. These suspensions were exposed to 99 GHz CW electromagnetic radiation, generated by a Backward Wave Oscillator (BWO) tube base instrument with a horn antenna at the BWO exit, to obtain an almost ideal Gaussian beam. Calculations of the Gaussian beam show that a power of 0.2 mW/cm2 was obtained at the bacterial plane. Results: The experimental results show that 1 hour of exposure to 99 GHz CW electromagnetic radiation had no effect on E. coli viability and colony characterisation. In 19 h of radiation, the number of colonies forming units was half order of magnitude higher than the sham-exposed and the control. However, 19 h of exposure did not affect the E. coli metabolic activity. Conclusions: Exposure of E. coli to millimeter wave (MW) CW 99 GHz radiation for a short period did not affect the viability of E. coli bacterial cells. However, exposure for 19 h caused a slight proliferation but did not influence the metabolic activities of about 90 biochemical reactions that were examined. Hence, we assume that the slight proliferation (half order of magnitude) after 19 h of exposure dose not have a biological meaning.
- 1 February 2009
- Published by Journal of Solid Waste Technology and Management in The Journal of Solid Waste Technology and Management
- Vol. 35 (1) , 17-25
Application of Ionizing Radiation for Sludge Disinfection and Its Use for Irrigation and Fertilization
- 1 February 2009
- Published by Journal of Solid Waste Technology and Management in The Journal of Solid Waste Technology and Management
- Vol. 35 (1) , 17-25
Application of Ionizing Radiation for Sludge Disinfection and Its Use for Irrigation and Fertilization
- 1 January 2009
- Published by Springer Nature in IFMBE Proceedings
- p. 1-4
Development of New Radioactive Seeds Tm-170 for Brachytherapy
- 1 January 2009
- Published by Springer Nature in IFMBE Proceedings
- p. 1-4
Development of New Radioactive Seeds Tm-170 for Brachytherapy
- Open Access
- 1 June 2008
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 45 (sup5) , 20-23
Radiation Dosimetry in Brachytherapy, Introducing A Spherical Diode Dosimeter
Brachytherapy is a cancer treatment modality in which a radiation source is inserted into the tumor. It is done in one of two ways: Low Dose Rate (LDR) treatment where seeds are permanently implanted, or High Dose Rate (HDR), a short time exposure. The isotopes mostly used for LDR treatment are I-125 and Pd-103 of activity about 18.5 MBq per seed. HDR treatment is generally done with Ir-192 sources of activity 370 GBq. We introduce a new source for both HDR and LDR treatment, namely Tm-170. Safety considerations for the medical staff, the patient and people around him include: well shielded sources, shortest handling time and keeping uninvolved people at a safe distance. HDR sources are kept in a lead container and applied by a remote controlled delivery system. Radiation dosimetry and source calibration is done before the sources are applied to the patient. The methods used for dose measurement are: TLD, diode or ion chamber. We introduced a new diode for dosimetry, micro-spherical diode. This tiny diode causes very little perturbation and provides spherically symmetrical dose measurements. Monte Carlo calculations are used to verify the measurements. Source parameters are calculated for source quality comparison.
- 1 June 2008
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 45 (sup5) , 20-23
Open AccessRadiation Dosimetry in Brachytherapy, Introducing A Spherical Diode Dosimeter
Brachytherapy is a cancer treatment modality in which a radiation source is inserted into the tumor. It is done in one of two ways: Low Dose Rate (LDR) treatment where seeds are permanently implanted, or High Dose Rate (HDR), a short time exposure. The isotopes mostly used for LDR treatment are I-125 and Pd-103 of activity about 18.5 MBq per seed. HDR treatment is generally done with Ir-192 sources of activity 370 GBq. We introduce a new source for both HDR and LDR treatment, namely Tm-170. Safety considerations for the medical staff, the patient and people around him include: well shielded sources, shortest handling time and keeping uninvolved people at a safe distance. HDR sources are kept in a lead container and applied by a remote controlled delivery system. Radiation dosimetry and source calibration is done before the sources are applied to the patient. The methods used for dose measurement are: TLD, diode or ion chamber. We introduced a new diode for dosimetry, micro-spherical diode. This tiny diode causes very little perturbation and provides spherically symmetrical dose measurements. Monte Carlo calculations are used to verify the measurements. Source parameters are calculated for source quality comparison.
- 12 July 2007
- Published by Springer Nature in Journal of Perinatology
- Vol. 27 (9) , 579-585
Unintentional exposure of neonates to conventional radiography in the Neonatal Intensive Care Units
Objective: Study Design: Result: Conclusion:
- 12 July 2007
- Published by Springer Nature in Journal of Perinatology
- Vol. 27 (9) , 579-585
Unintentional exposure of neonates to conventional radiography in the Neonatal Intensive Care Units
Objective: Study Design: Result: Conclusion:
- 30 June 2007
- Published by Springer Nature
- p. 1911-1913
4 $ \mathop \pi \limits_ \cdot $ Dosimetry for Brachytherapy Using Micro-Spherical Diodes- 30 June 2007
- Published by Springer Nature
- p. 1911-1913
4 $ \mathop \pi \limits_ \cdot $ Dosimetry for Brachytherapy Using Micro-Spherical Diodes- 1 February 2006
- Published by Wiley in Bioelectromagnetics
- Vol. 27 (2) , 119-126
Effects of radiofrequency radiation emitted by cellular telephones on the cognitive functions of humans
The present study examined the effects of exposure to Electromagnetic Radiation emitted by a standard GSM phone at 890 MHz on human cognitive functions. This study attempted to establish a connection between the exposure of a specific area of the brain and the cognitive functions associated with that area. A total of 36 healthy right‐handed male subjects performed four distinct cognitive tasks: spatial item recognition, verbal item recognition, and two spatial compatibility tasks. Tasks were chosen according to the brain side they are assumed to activate. All subjects performed the tasks under three exposure conditions: right side, left side, and sham exposure. The phones were controlled by a base station simulator and operated at their full power. We have recorded the reaction times (RTs) and accuracy of the responses. The experiments consisted of two sections, of 1 h each, with a 5 min break in between. The tasks and the exposure regimes were counterbalanced. The results indicated that the exposure of the left side of the brain slows down the left‐hand response time, in the second—later—part of the experiment. This effect was apparent in three of the four tasks, and was highly significant in only one of the tests. The exposure intensity and its duration exceeded the common exposure of cellular phone users. Bioelectromagnetics 27:119–126, 2006.
- 1 February 2006
- Published by Wiley in Bioelectromagnetics
- Vol. 27 (2) , 119-126
Effects of radiofrequency radiation emitted by cellular telephones on the cognitive functions of humans
The present study examined the effects of exposure to Electromagnetic Radiation emitted by a standard GSM phone at 890 MHz on human cognitive functions. This study attempted to establish a connection between the exposure of a specific area of the brain and the cognitive functions associated with that area. A total of 36 healthy right‐handed male subjects performed four distinct cognitive tasks: spatial item recognition, verbal item recognition, and two spatial compatibility tasks. Tasks were chosen according to the brain side they are assumed to activate. All subjects performed the tasks under three exposure conditions: right side, left side, and sham exposure. The phones were controlled by a base station simulator and operated at their full power. We have recorded the reaction times (RTs) and accuracy of the responses. The experiments consisted of two sections, of 1 h each, with a 5 min break in between. The tasks and the exposure regimes were counterbalanced. The results indicated that the exposure of the left side of the brain slows down the left‐hand response time, in the second—later—part of the experiment. This effect was apparent in three of the four tasks, and was highly significant in only one of the tests. The exposure intensity and its duration exceeded the common exposure of cellular phone users. Bioelectromagnetics 27:119–126, 2006.
- 11 November 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 94-97
PET properties of pixellated CdZnTe detector
- 11 November 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 94-97
PET properties of pixellated CdZnTe detector