GFGaetano Florio

Gaetano Florio

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gaetano Florio has a total of 108 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Risk assessment and prevention of postoperative and postprocedural respiratory failure: recommendations from an international expert panel

    by Michael E. Kiyatkin, Omid Azimaraghi, Takashi Asai, Marcos F Vidal Melo, Karuna Wongtangman, Aiman Suleiman, Gaetano Florio, Tomer Kotek, Ana Fernandez-Bustamante, Astrid Stucke, et al.


  • Open Access

    Treatment with inhaled Argon: a systematic review of pre-clinical and clinical studies with meta-analysis on neuroprotective effect

    by Giulia Merigo, Gaetano Florio, Fabiana Madotto, Aurora Magliocca, Ivan Silvestri, Francesca Fumagalli, Marianna Cerrato, Francesca Motta, Daria De Giorgio, Mauro Panigada, et al.


  • Hematocrit: The Neglected Variable of Extracorporeal CO2 Removal

    by Luigi Vivona, Michele Battistin, Eleonora Carlesso, Gaetano Florio, Serena Todaro, Sebastiano M. Colombo, Francesco Zadek, Giacomo Grasselli, Alberto Zanella, Thomas Langer


  • Impact of Positive End-Expiratory Pressure and FiO2 on Lung Mechanics and Intrapulmonary Shunt in Mechanically Ventilated Patients with ARDS Due to COVID-19 Pneumonia

    by Gaetano Florio, Alberto Zanella, Douglas Slobod, Amedeo Guzzardella, Ilaria Protti, Eleonora Carlesso, Arif Canakoglu, Jacopo Fumagalli, Vittorio Scaravilli, Sebastiano M. Colombo, et al.

    Purpose: This study aimed to investigate the effects of inspired oxygen fraction (FiO2) and positive end-expiratory pressure (PEEP) on gas exchange in mechanically ventilated patients with COVID-19. Methods: Two FiO2 (100%, 40%) were tested at 3 decreasing levels of PEEP (15, 10, and 5 cmH2O). At each FiO2 and PEEP, gas exchange, respiratory mechanics, hemodynamics, and the distribution of ventilation and perfusion were assessed with electrical impedance tomography. The impact of FiO2 on the intrapulmonary shunt (delta shunt) was analyzed as the difference between the calculated shunt at FiO2 100% (shunt) and venous admixture at FiO2 40% (venous admixture). Results: Fourteen patients were studied. Decreasing PEEP from 15 to 10 cmH2O did not change shunt (24 [21-28] vs 27 [24-29]%) or venous admixture (18 [15-26] vs 23 [18-34]%) while partial pressure of arterial oxygen (FiO2 100%) was higher at PEEP 15 (262 [198-338] vs 256 [147-315] mmHg; P < .05). Instead when PEEP was decreased from 10 to 5 cmH2O, shunt increased to 36 [30-39]% ( P < .05) and venous admixture increased to 33 [30-43]% ( P < .05) and partial pressure of arterial oxygen (100%) decreased to 109 [76-177] mmHg ( P < .05). At PEEP 15, administration of 100% FiO2 resulted in a shunt greater than venous admixture at 40% FiO2, ((24 [21-28] vs 18 [15-26]%, P = .005), delta shunt 5.5% (2.3-8.8)). Compared to PEEP 10, PEEP of 5 and 15 cmH2O resulted in decreased global and pixel-level compliance. Cardiac output at FiO2 100% resulted higher at PEEP 5 (5.4 [4.4-6.5]) compared to PEEP 10 (4.8 [4.1-5.5], P < .05) and PEEP 15 cmH2O (4.7 [4.5-5.4], P < .05). Conclusion: In this study, PEEP of 15 cmH2O, despite resulting in the highest oxygenation, was associated with overdistension. PEEP of 5 cmH2O was associated with increased shunt and alveolar collapse. Administration of 100% FiO2 was associated with an increase in intrapulmonary shunt in the setting of high PEEP. Trial registration: NCT05132933.


  • Bedside Evaluation of Pulmonary Embolism by Electrical Impedance Tomography

    by Luigi G. Grassi, Roberta Santiago, Gaetano Florio, Lorenzo Berra


  • Open Access

    Development of a Lung Rescue Team to Improve Care of Subjects With Refractory Acute Respiratory Failure

    by Stefano Spina, Martin Capriles, Roberta De Santis Santiago, Gaetano Florio, Maddalena Teggia-Droghi, Luigi Grassi, Jie Hu, Rosemary Kelley, Edward A Bittner, Robert M Kacmarek, et al.

    BACKGROUND: A lung-protective mechanical ventilation strategy has become the hallmark of ventilation management for patients with acute respiratory failure. However, some patients progress to more severe forms of acute respiratory failure with refractory hypoxemia. In such circumstances, individualized titration of mechanical ventilation according to the patient's specific respiratory and cardiovascular pathophysiology is desirable. A lung rescue team (LRT) was recently established at our institution to improve the medical care of patients with acute respiratory failure when conventional treatment fails. The aim of this report is to describe the consultation processes, the cardiopulmonary assessment, and the procedures of the LRT. METHODS: This was a retrospective review of the LRT management of patients with acute respiratory failure and refractory hypoxemia at Massachusetts General Hospital in Boston, Massachusetts. The LRT is composed of a critical care physician, the ICU respiratory therapist on duty, the ICU nurse on duty, and 2 critical care fellows. In the LRT approach, respiratory mechanics are evaluated through lung recruitment maneuvers and decremental PEEP trials by means of 3 tools: esophageal manometry, echocardiography, and electrical impedance tomography lung imaging. RESULTS: The LRT was consulted 89 times from 2014 to 2019 for evaluation and management of severely critically ill patients with acute respiratory failure and refractory hypoxemia on mechanical ventilation. The LRT was requested a median of 2 (interquartile range 1–6) d after intubation to optimize mechanical ventilation and to titrate PEEP in 77 (86%) subjects, to manage ventilation in 8 (9%) subjects on extracorporeal membrane oxygenation (ECMO), and to manage weaning strategy from mechanical ventilation in 4 (5%) subjects. The LRT found consolidations with atelectasis responsive to recruitment maneuvers in 79% ( n = 70) of consultations. The LRT findings translated into a change of care in 81% ( n = 72) of subjects. CONCLUSIONS: The LRT individualized the management of severe acute respiratory failure. The LRT consultations were shown to be effective, safe, and efficient, with an impact on decision-making in the ICU.


  • Open Access

    A lung rescue team improves survival in obesity with acute respiratory distress syndrome

    by For the investigators of the lung rescue team, Gaetano Florio, Matteo Ferrari, Edward A. Bittner, Roberta De Santis Santiago, Massimiliano Pirrone, Jacopo Fumagalli, Maddalena Teggia Droghi, Cristina Mietto, Riccardo Pinciroli, et al.

    Background: Limited data exist regarding ventilation in patients with class III obesity [body mass index (BMI) > 40 kg/m2] and acute respiratory distress syndrome (ARDS). The aim of the present study was to determine whether an individualized titration of mechanical ventilation according to cardiopulmonary physiology reduces the mortality in patients with class III obesity and ARDS. Methods: In this retrospective study, we enrolled adults admitted to the ICU from 2012 to 2017 who had class III obesity and ARDS and received mechanical ventilation for > 48 h. Enrolled patients were divided in two cohorts: one cohort (2012–2014) had ventilator settings determined by the ARDSnet table for lower positive end-expiratory pressure/higher inspiratory fraction of oxygen (standard protocol-based cohort); the other cohort (2015–2017) had ventilator settings determined by an individualized protocol established by a lung rescue team (lung rescue team cohort). The lung rescue team used lung recruitment maneuvers, esophageal manometry, and hemodynamic monitoring. Results: The standard protocol-based cohort included 70 patients (BMI = 49 ± 9 kg/m2), and the lung rescue team cohort included 50 patients (BMI = 54 ± 13 kg/m2). Patients in the standard protocol-based cohort compared to lung rescue team cohort had almost double the risk of dying at 28 days [31% versus 16%, P = 0.012; hazard ratio (HR) 0.32; 95% confidence interval (CI95%) 0.13–0.78] and 3 months (41% versus 22%, P = 0.006; HR 0.35; CI95% 0.16–0.74), and this effect persisted at 6 months and 1 year (incidence of death unchanged 41% versus 22%, P = 0.006; HR 0.35; CI95% 0.16–0.74). Conclusion: Individualized titration of mechanical ventilation by a lung rescue team was associated with decreased mortality compared to use of an ARDSnet table.


  • An Artificial Cough Maneuver to Remove Secretions From Below the Endotracheal Tube Cuff

    by Alberto Zanella, Gaetano Florio, Emanuele Rezoagli, Martina Pastore, Paolo Cadringer, Osvaldo Biancolilli, Eleonora Carlesso, Vittorio Scaravilli, Giuseppe Ristagno, Antonio M Pesenti

    BACKGROUND: Endotracheal suctioning is mandatory to prevent complications caused by the retention of tracheal secretions. Endotracheal suctioning is often performed late, when patients show signs of respiratory and hemodynamic alterations. We conceived a prototype device that, when synchronized with the ventilator, automatically removes secretions collected below the endotracheal tube (ETT) cuff, thus avoiding endotracheal suctioning. The aim of our investigation was to assess the performance of this novel prototype in vitro. METHODS: Three studies were performed to examine the characteristics of the prototype. We tested device's ability to generate an effective artificial cough flow (artificial cough maneuver) > 1 L/s by rapidly deflating the ETT cuff within the time of a sustained inflation (at 30 and at 40 cm H 2 O) (cough flow study). We also tested the prototype's ability to remove the fluid positioned below the ETT cuff using saline dye (fluid removal study), and to prevent the aspiration of saline dye from above the ETT cuff during the deflation phase of the ETT cuff (aspiration study). The trachea model was positioned at 45° in the aspiration study, and horizontally in the other two studies. RESULTS: In the cough flow study, the prototype provided an effective artificial cough maneuver, with a mean ± SD of 1.78 ± 0.19 L/s (range, 1.42–2.14 L/s). The tracheal pressure after ETT cuff deflation never decreased below the PEEP level. In the fluid removal study, the prototype cleared the fluid from below the ETT cuff and the experimental trachea. No fluid was aspirated from the area above the ETT cuff toward the lower airways. CONCLUSIONS: We conceived an system capable of automatically expelling fluid from below the ETT cuff outside an experimental trachea by generating an artificial cough maneuver. This system may decrease the use of endotracheal suctioning and its complications. Future in vivo studies are needed to confirm this first in vitro evaluation.


  • Interpretation of Transpulmonary Pressure Measurements in a Patient with Acute Life-Threatening Pulmonary Edema

    by Gaetano Florio, Simone Redaelli, Kenneth Shelton, Maddalena Teggia Droghi, Roberta Santiago, Francesco Marrazzo, Robert Kacmarek, Lorenzo Berra


  • Noninvasive Assessment of Respiratory Function: Capnometry, Lung Ultrasound, and Electrical Impedance Tomography

    by Gaetano Florio, Luca Di Girolamo, Andrea Clarissa Lusardi, Giulia Roveri, Marco Dei Poli