Luigi Parise
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Luigi Parise has a total of 174 co-authors. Here are the top co-authors by number of shared publications:
- Giuseppe Parise
Industrial Engineering Department, Sapienza University of Rome, Rome, Italy
69 shared publications - Luigi Martirano
Sapienza University of Rome, Rome, Italy
60 shared publications Giuseppe Parise
IEEE Industry Applications Society
27 shared publicationsG. Parise
University of Rome,Electrical and Energy Engineering (DIAEE) Sapienza,Department of Astronautical,Italy
21 shared publicationsChun-Lien Su
National Kaohsung University of Science and Technology,Department of Marine Engineering,Taiwan
9 shared publicationsErling Hesla
Hesla & Assoc., WA, USA
9 shared publications
Latest Publications
- 10 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (1) , 358-366
Method of the Protected Volume LPZ0B of Lightning Air-Termination Systems
The protection system for the structures against lightning is basically constituted by means of an air termination system, down-conductors and a ground-termination system. The IEC standard 62305 introduces the rolling sphere method to analyze and to design the protected volumes of air-termination systems with a complex configuration. In order to avoid the exposure of equipment and elements on the building roof to direct lightning in the design and the following operation with new exigencies, the identification of the protected volumes LPZ0B allows taking corrective measures if needed. The suggested method assumes as reference element a pair of rods for the air termination system and proposes to identify the protected volume combining the two IEC methods of the graphical rolling sphere with the protective angle. The protected volume method proposes, as simpler first step, the mathematical calculation of the minimum protection height of prospected profile described by the rolling sphere, useful for a preliminary evaluation. As second step, the method completes the definition of the protected volume section, describing a cautionary model that replaces the circular sector of the rolling sphere with a “vase section” shape, applying the protective angle method.
- 10 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (1) , 358-366
Method of the Protected Volume LPZ0B of Lightning Air-Termination Systems
The protection system for the structures against lightning is basically constituted by means of an air termination system, down-conductors and a ground-termination system. The IEC standard 62305 introduces the rolling sphere method to analyze and to design the protected volumes of air-termination systems with a complex configuration. In order to avoid the exposure of equipment and elements on the building roof to direct lightning in the design and the following operation with new exigencies, the identification of the protected volumes LPZ0B allows taking corrective measures if needed. The suggested method assumes as reference element a pair of rods for the air termination system and proposes to identify the protected volume combining the two IEC methods of the graphical rolling sphere with the protective angle. The protected volume method proposes, as simpler first step, the mathematical calculation of the minimum protection height of prospected profile described by the rolling sphere, useful for a preliminary evaluation. As second step, the method completes the definition of the protected volume section, describing a cautionary model that replaces the circular sector of the rolling sphere with a “vase section” shape, applying the protective angle method.
- Open Access
- 11 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Industry Applications Magazine
- Vol. 28 (3) , 1-2
Table of Contents
Presents the table of contents for this issue of the publication.
- 11 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Industry Applications Magazine
- Vol. 28 (3) , 1-2
Open AccessTable of Contents
Presents the table of contents for this issue of the publication.
- 27 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (5) , 4456-4461
Safety Upgrades in Domestic Dwellings. Pluggable Off-Line UPSs of Low Quality and Backfeed Hazards
International policies incentive the reduction of energy consumptions in domestic dwellings and the use of energy from renewable sources, but do not sufficiently support their safety. Many domestic dwellings in many countries operate with the supplying neutral grounded (T) and with all the exposed conductive parts isolated (I) that is with a TI-system. This paper deals with a concise presentation of this unclassified types of grounding systems and, then, with the backfeed hazard originated by pluggable off-line UPSs very commons in homes of stressed electrical grids. Against frequent blackouts, the users install battery powered automatic switchover type standby off line UPS. UPSs of low quality are unsafe and must be upgraded. Cases of back feed have been noted into utility supply lines from these UPSs and linemen doing maintenance by switching off supply receiving fatal shocks. This paper examines the reasons for such back feed and gives few methods to eliminate fatal and often unforeseen back feed. It briefly discusses the needs of upgrading TI-system to TT-system, basic for the safety protection against touch voltages in domestic dwellings. It concludes expecting in a next time the promotion of the global grounding system as constitution of a public grounding service organized and managed similarly to the water, gas, energy, telephone or internet services.
- 27 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (5) , 4456-4461
Safety Upgrades in Domestic Dwellings. Pluggable Off-Line UPSs of Low Quality and Backfeed Hazards
International policies incentive the reduction of energy consumptions in domestic dwellings and the use of energy from renewable sources, but do not sufficiently support their safety. Many domestic dwellings in many countries operate with the supplying neutral grounded (T) and with all the exposed conductive parts isolated (I) that is with a TI-system. This paper deals with a concise presentation of this unclassified types of grounding systems and, then, with the backfeed hazard originated by pluggable off-line UPSs very commons in homes of stressed electrical grids. Against frequent blackouts, the users install battery powered automatic switchover type standby off line UPS. UPSs of low quality are unsafe and must be upgraded. Cases of back feed have been noted into utility supply lines from these UPSs and linemen doing maintenance by switching off supply receiving fatal shocks. This paper examines the reasons for such back feed and gives few methods to eliminate fatal and often unforeseen back feed. It briefly discusses the needs of upgrading TI-system to TT-system, basic for the safety protection against touch voltages in domestic dwellings. It concludes expecting in a next time the promotion of the global grounding system as constitution of a public grounding service organized and managed similarly to the water, gas, energy, telephone or internet services.
- 4 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (3) , 2098-2103
IoT Innovations and Forensic Engineering in the Digital Age
IoT innovations produce interesting opportunities, impact ethical and social aspects towards human society and influence operational and technical solutions towards the structural systems. This paper discusses the impact of some relevant characteristics of the IoT innovations. Significant debated aspects are the product discontinuity in the global market, their durability, the upcoming “social” virtual systems, new “socialized” equipment, the promotion of electrical microsystems, the human competence in the digital age, the safety, operability and security of IoT. These innovations require an advancement of the technical culture and open new frontiers for electro forensic engineering. In the next future forensic engineering can promote an international reference organization as mediator between social, technical and regulatory aspects. Innovations and efficient sustainability need adequate global regulatory changes to favor the spreading of advantages, with more cert success if old business are transferred into new business.
- 4 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (3) , 2098-2103
IoT Innovations and Forensic Engineering in the Digital Age
IoT innovations produce interesting opportunities, impact ethical and social aspects towards human society and influence operational and technical solutions towards the structural systems. This paper discusses the impact of some relevant characteristics of the IoT innovations. Significant debated aspects are the product discontinuity in the global market, their durability, the upcoming “social” virtual systems, new “socialized” equipment, the promotion of electrical microsystems, the human competence in the digital age, the safety, operability and security of IoT. These innovations require an advancement of the technical culture and open new frontiers for electro forensic engineering. In the next future forensic engineering can promote an international reference organization as mediator between social, technical and regulatory aspects. Innovations and efficient sustainability need adequate global regulatory changes to favor the spreading of advantages, with more cert success if old business are transferred into new business.
- 22 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (1) , 94-100
Operational Resilience of Hospital Power Systems in the Digital Age
An advanced guideline is required to support the design of power supply systems for performances of service continuity and power outage resilience, which are vital for hospital power systems and strategic operational structures (SOS). The supply sources, the power system topology and its management are fundamental in guaranteeing the electrical resilience of the power system. There is still no standard to evaluate the adequacy of hospital power systems for natural calamities and human-made disasters and subsequently for the ordinary operation. The World Health Organization (WHO) recognizes it as a basic problem and at this aim has to claim clearly the status of strategic operational structures for the hospitals, recommending to safeguard and plan the full operability. The hospital power systems need a local fortified electrical structure, designed for service continuity during fault events and managed to ensure an adequate dynamic response to any emergency and maintenance needs. The importance of a Business Continuity Management (BCM) is highlighted; it has to be qualified for a permanent design with both the in-op approaches for the initial installation of the system and its life cycle operation.
- 22 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (1) , 94-100
Operational Resilience of Hospital Power Systems in the Digital Age
An advanced guideline is required to support the design of power supply systems for performances of service continuity and power outage resilience, which are vital for hospital power systems and strategic operational structures (SOS). The supply sources, the power system topology and its management are fundamental in guaranteeing the electrical resilience of the power system. There is still no standard to evaluate the adequacy of hospital power systems for natural calamities and human-made disasters and subsequently for the ordinary operation. The World Health Organization (WHO) recognizes it as a basic problem and at this aim has to claim clearly the status of strategic operational structures for the hospitals, recommending to safeguard and plan the full operability. The hospital power systems need a local fortified electrical structure, designed for service continuity during fault events and managed to ensure an adequate dynamic response to any emergency and maintenance needs. The importance of a Business Continuity Management (BCM) is highlighted; it has to be qualified for a permanent design with both the in-op approaches for the initial installation of the system and its life cycle operation.
- 14 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1
ELECTRICAL INTEGRITY RESILIENCE OF DATA CENTERS AND CRITICAL LOADS
The design criteria of powers systems for critical loads has to guarantee their continuous availability. This paper suggests modules of system as reference topologies for data centers, recommending at least a dual-connected utility supply. These modules of system aim to guarantee the service continuity of the loads and, in particular, of the critical loads. The introduced resilience codes for topology integrity TIR and integrity levels ILR represent an index of the system complexity and a numerical codification of service restoration against maintenance exigencies, faults and utility outages at every distribution level. For a resilient supplying system of all the mission critical systems, the goal is to maintain the service continuity of the loads and to restore the outages of the utility supply limiting the operation of engine generators and uninterruptible power supply at the shortest transient duration. The management staff is an essential completion to the integrity resilience. The paper deals with a case study of a very important data center to analyze some details for the service continuity on the performances by design.
- 14 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1
ELECTRICAL INTEGRITY RESILIENCE OF DATA CENTERS AND CRITICAL LOADS
The design criteria of powers systems for critical loads has to guarantee their continuous availability. This paper suggests modules of system as reference topologies for data centers, recommending at least a dual-connected utility supply. These modules of system aim to guarantee the service continuity of the loads and, in particular, of the critical loads. The introduced resilience codes for topology integrity TIR and integrity levels ILR represent an index of the system complexity and a numerical codification of service restoration against maintenance exigencies, faults and utility outages at every distribution level. For a resilient supplying system of all the mission critical systems, the goal is to maintain the service continuity of the loads and to restore the outages of the utility supply limiting the operation of engine generators and uninterruptible power supply at the shortest transient duration. The management staff is an essential completion to the integrity resilience. The paper deals with a case study of a very important data center to analyze some details for the service continuity on the performances by design.
- 20 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (2) , 1156-1161
Grounding Microgrid Systems in Metropolitan and Commercial Areas
Adjacent-grounding systems, in metropolitan areas, are usually interfering, because moreover common external conductive parts interconnect naturally them. Their integration to constitute a grounding microgrid system GMS allows making each grounding system more extended than its ground electrode. It assists resolutely to present limited touch voltages permissible to persist longer than 10 s and so to create the conditions of an intrinsically safe grounding system ISGS. An intentional common integration of adjacent-grounding systems is admissible, because each one of the grounding systems must satisfy equal protection requirements prescribed by utilities. This paper deals with three sample cases of measurements on grounding systems in areas with high GSs density and of a large size. The tests allows identifying a grounding microgrid system assessing for each component ground electrode a dispersing capacity of the fault current more extended than its size up to the dimension of the efficiency saturation with the minimum impedance value. The identification by measures of grounding microgrid systems contribute to recognize and improve natural integrations and promote the progress of the common safety, regardless of formal validation.
- 20 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (2) , 1156-1161
Grounding Microgrid Systems in Metropolitan and Commercial Areas
Adjacent-grounding systems, in metropolitan areas, are usually interfering, because moreover common external conductive parts interconnect naturally them. Their integration to constitute a grounding microgrid system GMS allows making each grounding system more extended than its ground electrode. It assists resolutely to present limited touch voltages permissible to persist longer than 10 s and so to create the conditions of an intrinsically safe grounding system ISGS. An intentional common integration of adjacent-grounding systems is admissible, because each one of the grounding systems must satisfy equal protection requirements prescribed by utilities. This paper deals with three sample cases of measurements on grounding systems in areas with high GSs density and of a large size. The tests allows identifying a grounding microgrid system assessing for each component ground electrode a dispersing capacity of the fault current more extended than its size up to the dimension of the efficiency saturation with the minimum impedance value. The identification by measures of grounding microgrid systems contribute to recognize and improve natural integrations and promote the progress of the common safety, regardless of formal validation.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Grounding Microgrid Systems in Metropolitan and Commercial Areas
The IEC/EN standards introduce the global grounding system GGS that ensures no dangerous touch voltages to all the interconnected grounding systems and, in practice, creates an intrinsically safe grounding system ISGS when permits indefinitely touch voltages no higher than the conventional limit value. The interconnection of the grounding systems through the cable shields of the utilities distribution contributes to constitute a global grounding system so that the utilities have the responsibility in validating the existence of a GGS. A grounding system, out of a GGS, has to satisfy safety conditions in reference to parameters of the point of delivery communicated by utility. The grounding systems, in metropolitan and commercial areas, are usually interfering and common external conductive parts interconnect them in fact. In these areas, an intentional integration between adjacent grounding systems of users, satisfying equal protection requirements, assists resolutely to satisfy the safety conditions of an ISGS. The constitution of grounding microgrid systems GMSs contribute to recognize and perfect situations in fact and promote the common interest of safety, regardless of formal validation from the utilities.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Grounding Microgrid Systems in Metropolitan and Commercial Areas
The IEC/EN standards introduce the global grounding system GGS that ensures no dangerous touch voltages to all the interconnected grounding systems and, in practice, creates an intrinsically safe grounding system ISGS when permits indefinitely touch voltages no higher than the conventional limit value. The interconnection of the grounding systems through the cable shields of the utilities distribution contributes to constitute a global grounding system so that the utilities have the responsibility in validating the existence of a GGS. A grounding system, out of a GGS, has to satisfy safety conditions in reference to parameters of the point of delivery communicated by utility. The grounding systems, in metropolitan and commercial areas, are usually interfering and common external conductive parts interconnect them in fact. In these areas, an intentional integration between adjacent grounding systems of users, satisfying equal protection requirements, assists resolutely to satisfy the safety conditions of an ISGS. The constitution of grounding microgrid systems GMSs contribute to recognize and perfect situations in fact and promote the common interest of safety, regardless of formal validation from the utilities.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Topology of Integrity Resilience for Service Continuity of Critical Loads
The critical loads, such as hospitals, data centers, institutional services, require systems of continuous availability and their design criteria has to be aimed not only at installation but also at the operational management of the system (In-Op design). This paper highlights how the topology of the infrastructure of a medium/low voltage system must offer performances by design for the service continuity and, in particular, a fault tolerant behavior. This paper suggests special modules of system for the mission critical loads recommending at least a dual-hot supply. These modules aim to guarantee the triple integrity levels ILs against loss services transitory, of short and long time. They also offer integrity resilience IR with adequate capacity of restoring service at every distribution level against maintenance exigencies, faults and utility disservices. Therefore, local power production systems become crucial and not primary with a smoother management. Essential complement to the integrity levels and resiliencies is the management staff. It has to be qualified, trained to operate the safety and integrity procedures for effective use of all the performances of the power systems with a safe service continuity. The paper deals with a case study to analyze some details on performances by design for the service continuity.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Topology of Integrity Resilience for Service Continuity of Critical Loads
The critical loads, such as hospitals, data centers, institutional services, require systems of continuous availability and their design criteria has to be aimed not only at installation but also at the operational management of the system (In-Op design). This paper highlights how the topology of the infrastructure of a medium/low voltage system must offer performances by design for the service continuity and, in particular, a fault tolerant behavior. This paper suggests special modules of system for the mission critical loads recommending at least a dual-hot supply. These modules aim to guarantee the triple integrity levels ILs against loss services transitory, of short and long time. They also offer integrity resilience IR with adequate capacity of restoring service at every distribution level against maintenance exigencies, faults and utility disservices. Therefore, local power production systems become crucial and not primary with a smoother management. Essential complement to the integrity levels and resiliencies is the management staff. It has to be qualified, trained to operate the safety and integrity procedures for effective use of all the performances of the power systems with a safe service continuity. The paper deals with a case study to analyze some details on performances by design for the service continuity.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Optimization of Energy Consumption in STS Group Cranes by Using Hybrid Energy Storage Systems Based on PSO Algorithm
In this paper, to avoid peak demand rising and energy management for ship to shore (STS) cranes, three main steps based on the optimization method are considered. The first step for peak shaving in this paper is demand side management (DSM). Since the new generation of STS cranes installed at the port of Long Beach (POLB) are equipped with regenerative capabilities to absorb up to 90% of the energy by the coordination of cranes' duty cycles. For the second part, the utilization of ultracapacitor (UC) is made for local peak shaving for each STS Crane. Finally, a Hybrid Energy Storage System (HESS) for comprehensive peak shaving is used. Since each STS Crane has a separate DC bus, the UC cannot do the peak shaving for the group cranes. For this purpose, for each DC bus in an STS Crane and UC bank can be considered to provide the local peak shaving and HESS is able to do the general peak shaving for two STS groups cranes where each group consists of 4 or 5 STS cranes. This is because for all groups there is a common AC bus and HESS can be installed between the groups. Also, integration on HESS is able to decrease significantly the required power in point of POLB as well. The control strategy proposed in this paper is capable to control the sudden power increase in CTs due to the use of a greater number of STS cranes and enhance the productivity of the system.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Optimization of Energy Consumption in STS Group Cranes by Using Hybrid Energy Storage Systems Based on PSO Algorithm
In this paper, to avoid peak demand rising and energy management for ship to shore (STS) cranes, three main steps based on the optimization method are considered. The first step for peak shaving in this paper is demand side management (DSM). Since the new generation of STS cranes installed at the port of Long Beach (POLB) are equipped with regenerative capabilities to absorb up to 90% of the energy by the coordination of cranes' duty cycles. For the second part, the utilization of ultracapacitor (UC) is made for local peak shaving for each STS Crane. Finally, a Hybrid Energy Storage System (HESS) for comprehensive peak shaving is used. Since each STS Crane has a separate DC bus, the UC cannot do the peak shaving for the group cranes. For this purpose, for each DC bus in an STS Crane and UC bank can be considered to provide the local peak shaving and HESS is able to do the general peak shaving for two STS groups cranes where each group consists of 4 or 5 STS cranes. This is because for all groups there is a common AC bus and HESS can be installed between the groups. Also, integration on HESS is able to decrease significantly the required power in point of POLB as well. The control strategy proposed in this paper is capable to control the sudden power increase in CTs due to the use of a greater number of STS cranes and enhance the productivity of the system.