Rahman Wagiran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rahman Wagiran has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Mohd Nizar Hamidon
Universiti Putra Malaysia
8 shared publications R. Sidek
Dept. of Electr. & Electron. Eng., Universiti Putra Malaysia, Selangor, Malaysia
6 shared publications- Hamid Farahani
Freiburg Materials Research Center, FMF, University of Freiburg, Stefan-Meier-Str. 21, 79104 Freiburg, Germany
5 shared publications - Abdul Halim Shaari
Superconductor and Thin Film Laboratory, Department of Physics, Faculty of Science, Universiti Putra Malaysia, UPM, Serdang 43400, Selangor Darul Ehsan, Malaysia
4 shared publications B.S. Suparjo
4 shared publications- Norhafizah Abdullah
Universiti Putra Malaysia
4 shared publications
Latest Publications
- 9 November 2021
- Published by American Chemical Society (ACS) in ACS Applied Electronic Materials
- Vol. 3 (11) , 4919-4933
Barium Strontium Titanate-Based Humidity Sensors: Microstructure, Surface Morphology, Dopant Influence, and Transduction Mechanism Investigations
- 9 November 2021
- Published by American Chemical Society (ACS) in ACS Applied Electronic Materials
- Vol. 3 (11) , 4919-4933
Barium Strontium Titanate-Based Humidity Sensors: Microstructure, Surface Morphology, Dopant Influence, and Transduction Mechanism Investigations
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Perovskites As Surface-Assisted Room Temperature Protonic Conductor Humidity Sensor
This paper shows a correlation between surface effective porosity due to various sintering regimes and humidity sensitive electrical properties of the perovskite-based bulk type humidity sensors. Furthermore, room temperature humidity transduction mechanism of the thick film type humidity sensors was studied in details through electrochemical impedance spectroscopy (EIS) and major transmissive components were detected by fitting to the equivalent circuits. The materials were synthesized employing solid state reaction and bulk and film type devices were fabricated by hydraulic pressing and screen printing techniques, respectively. The morphological and elemental characterizations were carried on using FESEM, EFTEM, and EDX. Physical properties including open porosity/bulk density were investigated through ASTM methods. An innovative self-designed material test fixture with ceramic supports was fabricated for high S/N ratio electrical measurement of the bulk samples. All the sensors were set up at 20-95% RH. The morphological, physical, and electrical results of bulk pellets indicate direct correlation of the open cavities and AC conduction. Presence of the ionic transport is clearly observed from the frequency-conductance spectra at room temperature. Noise-free detected behavior via EIS proves that proton transfer mechanism is a dominant responsible.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Perovskites As Surface-Assisted Room Temperature Protonic Conductor Humidity Sensor
This paper shows a correlation between surface effective porosity due to various sintering regimes and humidity sensitive electrical properties of the perovskite-based bulk type humidity sensors. Furthermore, room temperature humidity transduction mechanism of the thick film type humidity sensors was studied in details through electrochemical impedance spectroscopy (EIS) and major transmissive components were detected by fitting to the equivalent circuits. The materials were synthesized employing solid state reaction and bulk and film type devices were fabricated by hydraulic pressing and screen printing techniques, respectively. The morphological and elemental characterizations were carried on using FESEM, EFTEM, and EDX. Physical properties including open porosity/bulk density were investigated through ASTM methods. An innovative self-designed material test fixture with ceramic supports was fabricated for high S/N ratio electrical measurement of the bulk samples. All the sensors were set up at 20-95% RH. The morphological, physical, and electrical results of bulk pellets indicate direct correlation of the open cavities and AC conduction. Presence of the ionic transport is clearly observed from the frequency-conductance spectra at room temperature. Noise-free detected behavior via EIS proves that proton transfer mechanism is a dominant responsible.
- Open Access
- 13 December 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 1007
Barium Strontium Titanate Humidity Sensor: Impact of Doping on the Structural and Electrical Properties
The influence of Mg2+ doping (3 mol %) on structural and humidity sensing properties of (Ba0.5,Sr0.5)TiO3 (BST) perovskite nanocomposite were studied in details. Microstructural properties revealed the particle size, surface area, and average pore volume diminished for doped sample. For the MgO doped BST sensor, the film resistance and total impedance are changed more than four orders of magnitude in the 20–95% RH range, while BST sensor shows three orders change. The 3 mol % MgO doped sample with maximum hysteresis of 6.1 RH% and response/recovery time of about 30/80 s exhibits faster characteristics compare to pure BST sample with 6.8 RH% hysteresis and response/recovery of 41 s and 98 s, respectively. Transduction mechanism was found based on the proton transfer and further confirmed by a Bode plot and Nyquist complex impedance plane plot.
- 13 December 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 1007
Open AccessBarium Strontium Titanate Humidity Sensor: Impact of Doping on the Structural and Electrical Properties
The influence of Mg2+ doping (3 mol %) on structural and humidity sensing properties of (Ba0.5,Sr0.5)TiO3 (BST) perovskite nanocomposite were studied in details. Microstructural properties revealed the particle size, surface area, and average pore volume diminished for doped sample. For the MgO doped BST sensor, the film resistance and total impedance are changed more than four orders of magnitude in the 20–95% RH range, while BST sensor shows three orders change. The 3 mol % MgO doped sample with maximum hysteresis of 6.1 RH% and response/recovery time of about 30/80 s exhibits faster characteristics compare to pure BST sample with 6.8 RH% hysteresis and response/recovery of 41 s and 98 s, respectively. Transduction mechanism was found based on the proton transfer and further confirmed by a Bode plot and Nyquist complex impedance plane plot.
- Open Access
- 8 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 408
MgO-Doped (Zr,Sr)TiO3 Perovskite Humidity Sensors: Microstructural Effects on Water Permeation
Porous (Zr0.5,Sr0.5)TiO3 and MgO (1, 3, 5 mol%) doped ZST nanocomposites have been developed and investigated as humidity sensing elements. The surface area analyser and FESEM data have indicated that the MgO doped perovskites are contained of the macropores and grain size of about 77 to 87 nm. EFTEM proved the reduction of particle size by addition of MgO dopant concentration. While pure ZST shows BET surface area of about 58 m2/g, MgO doped samples exhibit about 12 m2/g. Sensor contained of ZST doped with 3 mol% MgO shows highest sensitivity with about four orders of magnitude change in impedance within the range of 20% to 95% RH.
- 8 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 408
Open AccessMgO-Doped (Zr,Sr)TiO3 Perovskite Humidity Sensors: Microstructural Effects on Water Permeation
Porous (Zr0.5,Sr0.5)TiO3 and MgO (1, 3, 5 mol%) doped ZST nanocomposites have been developed and investigated as humidity sensing elements. The surface area analyser and FESEM data have indicated that the MgO doped perovskites are contained of the macropores and grain size of about 77 to 87 nm. EFTEM proved the reduction of particle size by addition of MgO dopant concentration. While pure ZST shows BET surface area of about 58 m2/g, MgO doped samples exhibit about 12 m2/g. Sensor contained of ZST doped with 3 mol% MgO shows highest sensitivity with about four orders of magnitude change in impedance within the range of 20% to 95% RH.
- Top Cited PapersOpen Access
Humidity Sensors Principle, Mechanism, and Fabrication Technologies: A Comprehensive Review
Humidity measurement is one of the most significant issues in various areas of applications such as instrumentation, automated systems, agriculture, climatology and GIS. Numerous sorts of humidity sensors fabricated and developed for industrial and laboratory applications are reviewed and presented in this article. The survey frequently concentrates on the RH sensors based upon their organic and inorganic functional materials, e.g., porous ceramics (semiconductors), polymers, ceramic/polymer and electrolytes, as well as conduction mechanism and fabrication technologies. A significant aim of this review is to provide a distinct categorization pursuant to state of the art humidity sensor types, principles of work, sensing substances, transduction mechanisms, and production technologies. Furthermore, performance characteristics of the different humidity sensors such as electrical and statistical data will be detailed and gives an added value to the report. By comparison of overall prospects of the sensors it was revealed that there are still drawbacks as to efficiency of sensing elements and conduction values. The flexibility offered by thick film and thin film processes either in the preparation of materials or in the choice of shape and size of the sensor structure provides advantages over other technologies. These ceramic sensors show faster response than other types.
Top Cited PapersOpen AccessHumidity Sensors Principle, Mechanism, and Fabrication Technologies: A Comprehensive Review
Humidity measurement is one of the most significant issues in various areas of applications such as instrumentation, automated systems, agriculture, climatology and GIS. Numerous sorts of humidity sensors fabricated and developed for industrial and laboratory applications are reviewed and presented in this article. The survey frequently concentrates on the RH sensors based upon their organic and inorganic functional materials, e.g., porous ceramics (semiconductors), polymers, ceramic/polymer and electrolytes, as well as conduction mechanism and fabrication technologies. A significant aim of this review is to provide a distinct categorization pursuant to state of the art humidity sensor types, principles of work, sensing substances, transduction mechanisms, and production technologies. Furthermore, performance characteristics of the different humidity sensors such as electrical and statistical data will be detailed and gives an added value to the report. By comparison of overall prospects of the sensors it was revealed that there are still drawbacks as to efficiency of sensing elements and conduction values. The flexibility offered by thick film and thin film processes either in the preparation of materials or in the choice of shape and size of the sensor structure provides advantages over other technologies. These ceramic sensors show faster response than other types.
- 22 June 2012
- Published by Emerald Publishing in Sensor Review
- Vol. 32 (3) , 245-250
A simple capacitive biosensor device for histamine measurement
Purpose: The purpose of this paper is to describe a capacitive biosensor device consisting of an enzyme electrode and a simple detector which has been developed for histamine measurement.Design/methodology/approach: In this analysis, degradation of histamine through enzymatic reaction produces signal that is monitored using a simple detector equipped with “astable” multivibrator operation circuit (in capacitor‐resistor circuit).Findings: Different frequency (f) readings have been obtained for glucose, alcohol and histamine in different concentration levels, showing the ability of this simple device system to measure their dielectric constant (k) as formulated by the equation f=(1.44d)/ [kA (R1+2R2)]. The analysis using smaller electrode gap (d) produces higher value of f, indicating that d, is directly proportional to f. For histamine, by using immobilized enzyme electrode, the results show that the change of dielectric properties during the 300‐second reaction period could also be monitored. A linear relationship is obtained between concentration and frequency from 50 to 200 ppm.Practical implications: Based on this result, an enzyme electrode and “astable” operation circuits have the potential to be used in the development of a simple capacitive biosensor device.Originality/value: The paper is an outcome of experimental work carried out to observe capacitive sensing behavior using an immobilized enzyme, to measure biological samples, especially histamine.
- 22 June 2012
- Published by Emerald Publishing in Sensor Review
- Vol. 32 (3) , 245-250
A simple capacitive biosensor device for histamine measurement
Purpose: The purpose of this paper is to describe a capacitive biosensor device consisting of an enzyme electrode and a simple detector which has been developed for histamine measurement.Design/methodology/approach: In this analysis, degradation of histamine through enzymatic reaction produces signal that is monitored using a simple detector equipped with “astable” multivibrator operation circuit (in capacitor‐resistor circuit).Findings: Different frequency (f) readings have been obtained for glucose, alcohol and histamine in different concentration levels, showing the ability of this simple device system to measure their dielectric constant (k) as formulated by the equation f=(1.44d)/ [kA (R1+2R2)]. The analysis using smaller electrode gap (d) produces higher value of f, indicating that d, is directly proportional to f. For histamine, by using immobilized enzyme electrode, the results show that the change of dielectric properties during the 300‐second reaction period could also be monitored. A linear relationship is obtained between concentration and frequency from 50 to 200 ppm.Practical implications: Based on this result, an enzyme electrode and “astable” operation circuits have the potential to be used in the development of a simple capacitive biosensor device.Originality/value: The paper is an outcome of experimental work carried out to observe capacitive sensing behavior using an immobilized enzyme, to measure biological samples, especially histamine.
- Open Access
SnO2/Pt Thin Film Laser Ablated Gas Sensor Array
A gas sensor array was developed in a 10 × 10 mm2 space using Screen Printing and Pulse Laser Ablation Deposition (PLAD) techniques. Heater, electrode, and an insulator interlayer were printed using the screen printing method on an alumina substrate, while tin oxide and platinum films, as sensing and catalyst layers, were deposited on the electrode at room temperature using the PLAD method, respectively. To ablate SnO2 and Pt targets, depositions were achieved by using a 1,064 nm Nd-YAG laser, with a power of 0.7 J/s, at different deposition times of 2, 5 and 10 min, in an atmosphere containing 0.04 mbar (4 kPa) of O2. A range of spectroscopic diffraction and real space imaging techniques, SEM, EDX, XRD, and AFM were used in order to characterize the surface morphology, structure, and composition of the films. Measurement on the array shows sensitivity to some solvent and wood smoke can be achieved with short response and recovery times.
Open AccessSnO2/Pt Thin Film Laser Ablated Gas Sensor Array
A gas sensor array was developed in a 10 × 10 mm2 space using Screen Printing and Pulse Laser Ablation Deposition (PLAD) techniques. Heater, electrode, and an insulator interlayer were printed using the screen printing method on an alumina substrate, while tin oxide and platinum films, as sensing and catalyst layers, were deposited on the electrode at room temperature using the PLAD method, respectively. To ablate SnO2 and Pt targets, depositions were achieved by using a 1,064 nm Nd-YAG laser, with a power of 0.7 J/s, at different deposition times of 2, 5 and 10 min, in an atmosphere containing 0.04 mbar (4 kPa) of O2. A range of spectroscopic diffraction and real space imaging techniques, SEM, EDX, XRD, and AFM were used in order to characterize the surface morphology, structure, and composition of the films. Measurement on the array shows sensitivity to some solvent and wood smoke can be achieved with short response and recovery times.
- 1 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 263-266
Electrical response of multi-walled carbon nanotubes to ammonia and carbon dioxide
This paper presents the electrical response of Multi-Walled Carbon Nanotube (MWCNT) towards the presence of gases at room temperature. The preparation of MWCNT and the experimental setup are also discussed. The resistance of MWCNT elements is extracted from current-voltage measurements done at room temperature. The results show that there is a change in the resistance when the sensing element is exposed to either ammonia or carbon dioxide gas. Fast response time and recovery time have been achieved.
- 1 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 263-266
Electrical response of multi-walled carbon nanotubes to ammonia and carbon dioxide
This paper presents the electrical response of Multi-Walled Carbon Nanotube (MWCNT) towards the presence of gases at room temperature. The preparation of MWCNT and the experimental setup are also discussed. The resistance of MWCNT elements is extracted from current-voltage measurements done at room temperature. The results show that there is a change in the resistance when the sensing element is exposed to either ammonia or carbon dioxide gas. Fast response time and recovery time have been achieved.
- 1 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 88-91
Development of nanocrystalline laser ablated thick film array gas sensor
A multi-layer thick film array sensor for gas sensing application including heater element, insulator layer, and interdigitated electrodes was designed and fabricated on alumina substrate. Tin dioxide and platinum nanopowder were used in the pellet form as the active and catalyst layers, respectively. Pulse laser ablation deposition (PLAD) technique was used to deposit the sensitive layer onto the electrode part of each sensor. Microstructural and morphological properties of the sensor surface were determined. Sensors were exposed to wood smoke and their sensitivity were measured and compared with the results of the sensors without catalyst layer.
- 1 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 88-91
Development of nanocrystalline laser ablated thick film array gas sensor
A multi-layer thick film array sensor for gas sensing application including heater element, insulator layer, and interdigitated electrodes was designed and fabricated on alumina substrate. Tin dioxide and platinum nanopowder were used in the pellet form as the active and catalyst layers, respectively. Pulse laser ablation deposition (PLAD) technique was used to deposit the sensitive layer onto the electrode part of each sensor. Microstructural and morphological properties of the sensor surface were determined. Sensors were exposed to wood smoke and their sensitivity were measured and compared with the results of the sensors without catalyst layer.
- Open Access
Characterization of Mixed xWO3(1-x)Y2O3 Nanoparticle Thick Film for Gas Sensing Application
Microstructural, topology, inner morphology, and gas-sensitivity of mixed xWO3(1-x)Y2O3 nanoparticles (x = 1, 0.95, 0.9, 0.85, 0.8) thick-film semiconductor gas sensors were studied. The surface topography and inner morphological properties of the mixed powder and sensing film were characterized with X-ray diffraction (XRD), atomic force microscopy (AFM), transmission electron microscopy (TEM), and scanning electron microscopy (SEM). Also, gas sensitivity properties of the printed films were evaluated in the presence of methane (CH4) and butane (C4H10) at up to 500 °C operating temperature of the sensor. The results show that the doping agent can modify some structural properties and gas sensitivity of the mixed powder.
Open AccessCharacterization of Mixed xWO3(1-x)Y2O3 Nanoparticle Thick Film for Gas Sensing Application
Microstructural, topology, inner morphology, and gas-sensitivity of mixed xWO3(1-x)Y2O3 nanoparticles (x = 1, 0.95, 0.9, 0.85, 0.8) thick-film semiconductor gas sensors were studied. The surface topography and inner morphological properties of the mixed powder and sensing film were characterized with X-ray diffraction (XRD), atomic force microscopy (AFM), transmission electron microscopy (TEM), and scanning electron microscopy (SEM). Also, gas sensitivity properties of the printed films were evaluated in the presence of methane (CH4) and butane (C4H10) at up to 500 °C operating temperature of the sensor. The results show that the doping agent can modify some structural properties and gas sensitivity of the mixed powder.