Jose L. Elizondo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jose L. Elizondo has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Marco Rivera
University of Nottingham
10 shared publications - Osvaldo M. Micheloud
Tecnologico de Monterrey, Campus Monterrey, Monterrey, Nuevo Leon, Mexico
8 shared publications M. E. Macias
Department of Electrical and Computational Engineering, Tecnológico de Monterrey, Monterrey, Mexico
6 shared publicationsA. Olloqui
Department of Electrical and Computational Engineering, Tecnológico de Monterrey, Monterrey, Mexico
5 shared publications- Jose Rodriguez
Universidad San Sebastián Santiago
5 shared publications - Patrick Wheeler
University of Nottingham
4 shared publications
Latest Publications
- 17 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (2) , 1510-1516
Model-Based Predictive Rotor Current Control Strategy for Indirect Power Control of a DFIM Driven by an Indirect Matrix Converter
This paper presents a new control strategy using model-based predictive current control (MB-PCC) for a doubly fed induction machine (DFIM) driven by an indirect matrix converter (IMC). This strategy proposes the control of rotor currents, whose references are calculated from active and reactive stator power set points and the dynamic model of the DFIM. The control strategy works well in the four P-Q operating regions of the DFIM. The grid synchronization process is carried out by setting the P-Q power set points to zero. The results presented include the DFIM synchronization procedure as well as the active and reactive power control at variable shaft speed to validate the feasibility of the proposed strategy.
- 17 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (2) , 1510-1516
Model-Based Predictive Rotor Current Control Strategy for Indirect Power Control of a DFIM Driven by an Indirect Matrix Converter
This paper presents a new control strategy using model-based predictive current control (MB-PCC) for a doubly fed induction machine (DFIM) driven by an indirect matrix converter (IMC). This strategy proposes the control of rotor currents, whose references are calculated from active and reactive stator power set points and the dynamic model of the DFIM. The control strategy works well in the four P-Q operating regions of the DFIM. The grid synchronization process is carried out by setting the P-Q power set points to zero. The results presented include the DFIM synchronization procedure as well as the active and reactive power control at variable shaft speed to validate the feasibility of the proposed strategy.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Finite states-modulated model predictive control of a Quasi-z-Source Inverter with LCL filter
This paper presents a new Modulated Model Predictive Control (M 2 PC) scheme for a three phase Quasi-Impedance Source Inverter (QZSI). This scheme is the result of a delay error compensation implementation in an M 2 PC algorithm for a QZSI, and a technique to achieve fixed switching frequency for the ease of a passive LCL filter design. The transient and steady state response of the proposed algorithm is validated through simulation. The introduced control technique for a QZSI can be considered for further development of a reliable and efficient power converter suitable for renewable energy systems.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Finite states-modulated model predictive control of a Quasi-z-Source Inverter with LCL filter
This paper presents a new Modulated Model Predictive Control (M 2 PC) scheme for a three phase Quasi-Impedance Source Inverter (QZSI). This scheme is the result of a delay error compensation implementation in an M 2 PC algorithm for a QZSI, and a technique to achieve fixed switching frequency for the ease of a passive LCL filter design. The transient and steady state response of the proposed algorithm is validated through simulation. The introduced control technique for a QZSI can be considered for further development of a reliable and efficient power converter suitable for renewable energy systems.
- 12 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Overview of wind energy conversion systems development, technologies and power electronics research trends
Wind energy use has shown a remarkable increase in last years. In order to achieve the highest efficiency with the best characteristics in wind turbines, it is necessary to analyze relevant factors in wind energy conversion. In this review a state of the art is presented focused on modeling, constitutive elements, structure and control of wind generation systems and the increasing use of wind energy worldwide is evidenced.
- 12 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Overview of wind energy conversion systems development, technologies and power electronics research trends
Wind energy use has shown a remarkable increase in last years. In order to achieve the highest efficiency with the best characteristics in wind turbines, it is necessary to analyze relevant factors in wind energy conversion. In this review a state of the art is presented focused on modeling, constitutive elements, structure and control of wind generation systems and the increasing use of wind energy worldwide is evidenced.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Modulated model predictive rotor current control (M2PC) of a DFIG driven by an indirect matrix converter with fixed switching frequency
Conventional finite-set model-based predictive control (FS-MBPC) methods inherently present a variable switching frequency which causes harmonic distortion as well as excessive voltage and current ripple. An indirect power control strategy with fixed frequency capability is presented in this paper for a DFIG driven by an indirect matrix converter. The system initial conditions are maintained for the proposed method, showing improvement in terms of power quality when compared to the conventional FS-MBPC even when a lower sampling frequency is imposed. This strategy is verified to be feasible by successful simulation results, furtherly proving the predictive control capabilities of fast dynamic response and intuitive inclusion of nonlinear constraints into the control algorithm.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Modulated model predictive rotor current control (M2PC) of a DFIG driven by an indirect matrix converter with fixed switching frequency
Conventional finite-set model-based predictive control (FS-MBPC) methods inherently present a variable switching frequency which causes harmonic distortion as well as excessive voltage and current ripple. An indirect power control strategy with fixed frequency capability is presented in this paper for a DFIG driven by an indirect matrix converter. The system initial conditions are maintained for the proposed method, showing improvement in terms of power quality when compared to the conventional FS-MBPC even when a lower sampling frequency is imposed. This strategy is verified to be feasible by successful simulation results, furtherly proving the predictive control capabilities of fast dynamic response and intuitive inclusion of nonlinear constraints into the control algorithm.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 21, 2275-2280
Indirect power control of a DFIG using model-based predictive rotor current control with an indirect matrix converter
A new indirect power control strategy using model-based predictive current control (MB-PCC) is presented in this paper for a doubly fed induction generator (DFIG) driven by an indirect matrix converter suitable for wind energy systems. In this paper the power reference is used to develop a new expression for the stator current in terms of the rotor current. A step by step methodology is presented to generate a dynamic reference for the whole operating regions of the DFIG including synchronization process. Once the reference is generated model-based predictive control (MBPC) is used as it takes into account the nonlinear behavior of the power converter and the discrete-time system model to select the best switching state to be applied in the next sampling period. The switching state is selected using a cost function that minimizes the error between the references and the predicted values. Results are presented for fast and smooth synchronization of the DFIG and flexible active and reactive power control for variable shaft speed to validate the feasibility of the proposed strategy.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 21, 2275-2280
Indirect power control of a DFIG using model-based predictive rotor current control with an indirect matrix converter
A new indirect power control strategy using model-based predictive current control (MB-PCC) is presented in this paper for a doubly fed induction generator (DFIG) driven by an indirect matrix converter suitable for wind energy systems. In this paper the power reference is used to develop a new expression for the stator current in terms of the rotor current. A step by step methodology is presented to generate a dynamic reference for the whole operating regions of the DFIG including synchronization process. Once the reference is generated model-based predictive control (MBPC) is used as it takes into account the nonlinear behavior of the power converter and the discrete-time system model to select the best switching state to be applied in the next sampling period. The switching state is selected using a cost function that minimizes the error between the references and the predicted values. Results are presented for fast and smooth synchronization of the DFIG and flexible active and reactive power control for variable shaft speed to validate the feasibility of the proposed strategy.
- 20 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 2 (4) , 715-726
Model-Based Predictive Rotor Current Control for Grid Synchronization of a DFIG Driven by an Indirect Matrix Converter
A novel predictive rotor current control scheme for a doubly fed induction generator (DFIG) is implemented to perform the DFIG grid synchronization with a fast dynamic response. With this control strategy applied to an experimental setup, the rotor currents swiftly follow the necessary reference for grid synchronization in the range ±30% of the generator rated shaft speed. The DFIG and converter discrete models are used to predict the behavior of the rotor currents. By minimizing the error between the references and the predictive rotor currents for each of the valid states of the converter, the best-suited switching state is selected and applied at the next sampling time. To validate the feasibility of implementing this approach, simulations and experiments were carried out for various shaft speed profiles.
- 20 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 2 (4) , 715-726
Model-Based Predictive Rotor Current Control for Grid Synchronization of a DFIG Driven by an Indirect Matrix Converter
A novel predictive rotor current control scheme for a doubly fed induction generator (DFIG) is implemented to perform the DFIG grid synchronization with a fast dynamic response. With this control strategy applied to an experimental setup, the rotor currents swiftly follow the necessary reference for grid synchronization in the range ±30% of the generator rated shaft speed. The DFIG and converter discrete models are used to predict the behavior of the rotor currents. By minimizing the error between the references and the predictive rotor currents for each of the valid states of the converter, the best-suited switching state is selected and applied at the next sampling time. To validate the feasibility of implementing this approach, simulations and experiments were carried out for various shaft speed profiles.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 4907-4912
Predictive voltage control with imposed source current waveforms in an indirect matrix converter
In this paper is presented an alternative to generate sinusoidal output voltage waveforms using predictive control in an indirect matrix converter while achieving sinusoidal source currents on the input side. These objectives are accomplished by using a predictive control scheme which calculates the future values of the variables to be controlled in order to choose the converter state that produces the minimal error between them and their references. The proposed predictive method is tested by simulation results, obtaining sinusoidal output voltage and achieving a desired input displacement factor, with a low THD on both source currents and load voltages.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 4907-4912
Predictive voltage control with imposed source current waveforms in an indirect matrix converter
In this paper is presented an alternative to generate sinusoidal output voltage waveforms using predictive control in an indirect matrix converter while achieving sinusoidal source currents on the input side. These objectives are accomplished by using a predictive control scheme which calculates the future values of the variables to be controlled in order to choose the converter state that produces the minimal error between them and their references. The proposed predictive method is tested by simulation results, obtaining sinusoidal output voltage and achieving a desired input displacement factor, with a low THD on both source currents and load voltages.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 6063-6068
Comparison of Model Based Predictive Control and Fuzzy Logic Control of a DFIG with an Indirect Matrix Converter
In this paper two control techniques: Finite States - Model Based Predictive Control (FS - MBPC) and Fuzzy Logic Control (FLC) are developed to obtain arbitrary output currents, needed in a variable speed Wind Energy Conversion System (WECS). In this study, the simulation performance between FS-MBPC and FLC of the rotor current in a Doubly Fed Induction Generator (DFIG) with an Indirect Matrix Converter is evaluated. The simulations were carried out with constant shaft speed, and constant ramp speed with arbitrary rotor current references. Both FS-MBPC and FLC showed very high performance, following smoothly and rapidly the current reference with a very low error. The FS-MBPC dynamic response is slightly better than of the FLC. However, fewer mathematical calculations, and less measured data, and fewer computational requirements suggest that FLC can be easier to implement in FPGAs instead of composite microprocessor-based control platforms.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 6063-6068
Comparison of Model Based Predictive Control and Fuzzy Logic Control of a DFIG with an Indirect Matrix Converter
In this paper two control techniques: Finite States - Model Based Predictive Control (FS - MBPC) and Fuzzy Logic Control (FLC) are developed to obtain arbitrary output currents, needed in a variable speed Wind Energy Conversion System (WECS). In this study, the simulation performance between FS-MBPC and FLC of the rotor current in a Doubly Fed Induction Generator (DFIG) with an Indirect Matrix Converter is evaluated. The simulations were carried out with constant shaft speed, and constant ramp speed with arbitrary rotor current references. Both FS-MBPC and FLC showed very high performance, following smoothly and rapidly the current reference with a very low error. The FS-MBPC dynamic response is slightly better than of the FLC. However, fewer mathematical calculations, and less measured data, and fewer computational requirements suggest that FLC can be easier to implement in FPGAs instead of composite microprocessor-based control platforms.
- 1 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 4296-4301
Rotor current fuzzy control of a DFIG with an Indirect Matrix Converter
This paper presents a soft-computing technique to control the rotor current of a Doubly Fed Induction Generator (DFIG) using an Indirect Matrix Converter (IMC). The technique developed uses fuzzy logic to successfully control the rotor current, even with abnormal grid conditions, by governing the IMC rectifier and inverter sides. Although this control problem has been already analyzed and solved with conventional vector control and with Finite States Model Based Predictive Control (FS-MBPC), the fuzzy logic based controllers have a very acceptable response. The advantages of the developed technique are simpler code without the need of a specific mathematical model and robustness under grid abnormalities. These benefits decrease system costs, increase overall reliability and allow the control scheme to be implemented easily and entirely in FPGAs instead of DSPs-FPGA control systems.
- 1 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 4296-4301
Rotor current fuzzy control of a DFIG with an Indirect Matrix Converter
This paper presents a soft-computing technique to control the rotor current of a Doubly Fed Induction Generator (DFIG) using an Indirect Matrix Converter (IMC). The technique developed uses fuzzy logic to successfully control the rotor current, even with abnormal grid conditions, by governing the IMC rectifier and inverter sides. Although this control problem has been already analyzed and solved with conventional vector control and with Finite States Model Based Predictive Control (FS-MBPC), the fuzzy logic based controllers have a very acceptable response. The advantages of the developed technique are simpler code without the need of a specific mathematical model and robustness under grid abnormalities. These benefits decrease system costs, increase overall reliability and allow the control scheme to be implemented easily and entirely in FPGAs instead of DSPs-FPGA control systems.
- 1 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 2959-2965
Model predictive control of a Doubly Fed Induction Generator with an Indirect Matrix Converter
A simple and intuitive Doubly Fed Induction Generator (DFIG) predictive rotor current control scheme is presented. Predictive control of an Indirect Matrix Converter (IMC) is combined with predictive rotor current control of a DFIG to achieve a very good dynamic response as the rotor currents smoothly follow the applied reference in a ±30% range of the generator nominal rpm. Simulation results are presented for constant torque and rotational speed, as well as for variable rotational speed corresponding to a 10 kW generator dynamic response. Derivation and conjunction of each model equations are also presented along with a delay error compensation strategy to counter the practical implementation issue implicit in discrete time control computation.
- 1 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 2959-2965
Model predictive control of a Doubly Fed Induction Generator with an Indirect Matrix Converter
A simple and intuitive Doubly Fed Induction Generator (DFIG) predictive rotor current control scheme is presented. Predictive control of an Indirect Matrix Converter (IMC) is combined with predictive rotor current control of a DFIG to achieve a very good dynamic response as the rotor currents smoothly follow the applied reference in a ±30% range of the generator nominal rpm. Simulation results are presented for constant torque and rotational speed, as well as for variable rotational speed corresponding to a 10 kW generator dynamic response. Derivation and conjunction of each model equations are also presented along with a delay error compensation strategy to counter the practical implementation issue implicit in discrete time control computation.