Kayla B. Hicks
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kayla B. Hicks has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
A. Morgan Selleck
Department of Otolaryngology/Head and Neck Surgery University of North Carolina at Chapel Hill Chapel Hill North Carolina U.S.A.
1 shared publication- Adam J. Kimple
Department of Otolaryngology–Head and Neck Surgery University of North Carolina at Chapel Hill Chapel Hill North Carolina USA
1 shared publication Amit Gupta
University Hospitals Department of Radiology, Cleveland, OH, USA
1 shared publicationArmine Kocharyan
Department of Otolaryngology-Head and Neck Surgery, University Hospitals Cleveland Medical Center, Cleveland, OH, USA
1 shared publication- Cameron P. Worden
Department of Otolaryngology University of North Carolina at Chapel Hill Chapel Hill USA
1 shared publication - Eric Devaney
Pediatric Cardiac and Thoracic Surgery, University Hospitals Cleveland Medical Center, Cleveland, OH 44106, USA
1 shared publication
Latest Publications
- 14 February 2024
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 170 (5) , 1246-1269
The Toxicological Effects of e‐Cigarette Use in the Upper Airway: A Scoping Review
Objective: While evidence continues to emerge on the negative health effects of electronic cigarettes (e‐cigarettes) on the lungs, little is known regarding their deleterious effects on the upper airway. The purpose of this review is to summarize the toxicological effects of e‐cigarettes, and their components, on the upper airway.Data Sources: PubMed, SCOPUS, EMBASE databases.Review Methods: Systematic searches were performed in accordance with Preferred Reporting Items for Systematic Reviews and Meta‐analyses guidelines from 2003 to 2023. Studies were included if they investigated the toxicological effects of e‐cigarette exposure on human or animal upper airway tissue. Two authors independently screened, reviewed, and appraised all included articles.Results: A total of 822 unique articles were identified, of which 53 met inclusion criteria and spanned subsites including the oral cavity (22/53 studies), nasal cavity/nasopharynx (13/53), multiple sites (10/53), larynx (5/53), trachea (2/53), and oropharynx (1/53). The most commonly observed consequences of e‐cigarette use on the upper airway included: proinflammatory (15/53 studies), histological (13/53), cytotoxicity (11/53), genotoxicity (11/53), and procarcinogenic (6/53). E‐cigarette humectants independently induced toxicity at multiple upper airway subsites, however, effects were generally amplified when flavoring(s) and/or nicotine were added. Across almost all studies, exposure to cigarette smoke exhibited increased toxicity in the upper airway compared with exposure to e‐cigarette vapor.Conclusion: Current data suggest that while e‐cigarettes are generally less harmful than traditional cigarettes, they possess a distinct toxicological profile that is enhanced upon the addition of flavoring(s) and/or nicotine. Future investigations into underexamined subsites, such as the oropharynx and hypopharynx, are needed to comprehensively understand the effects of e‐cigarettes on the upper airway.
- 14 February 2024
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 170 (5) , 1246-1269
The Toxicological Effects of e‐Cigarette Use in the Upper Airway: A Scoping Review
Objective: While evidence continues to emerge on the negative health effects of electronic cigarettes (e‐cigarettes) on the lungs, little is known regarding their deleterious effects on the upper airway. The purpose of this review is to summarize the toxicological effects of e‐cigarettes, and their components, on the upper airway.Data Sources: PubMed, SCOPUS, EMBASE databases.Review Methods: Systematic searches were performed in accordance with Preferred Reporting Items for Systematic Reviews and Meta‐analyses guidelines from 2003 to 2023. Studies were included if they investigated the toxicological effects of e‐cigarette exposure on human or animal upper airway tissue. Two authors independently screened, reviewed, and appraised all included articles.Results: A total of 822 unique articles were identified, of which 53 met inclusion criteria and spanned subsites including the oral cavity (22/53 studies), nasal cavity/nasopharynx (13/53), multiple sites (10/53), larynx (5/53), trachea (2/53), and oropharynx (1/53). The most commonly observed consequences of e‐cigarette use on the upper airway included: proinflammatory (15/53 studies), histological (13/53), cytotoxicity (11/53), genotoxicity (11/53), and procarcinogenic (6/53). E‐cigarette humectants independently induced toxicity at multiple upper airway subsites, however, effects were generally amplified when flavoring(s) and/or nicotine were added. Across almost all studies, exposure to cigarette smoke exhibited increased toxicity in the upper airway compared with exposure to e‐cigarette vapor.Conclusion: Current data suggest that while e‐cigarettes are generally less harmful than traditional cigarettes, they possess a distinct toxicological profile that is enhanced upon the addition of flavoring(s) and/or nicotine. Future investigations into underexamined subsites, such as the oropharynx and hypopharynx, are needed to comprehensively understand the effects of e‐cigarettes on the upper airway.
- 27 December 2023
- Published by Wiley in The Laryngoscope
- Vol. 134 (5) , 2401-2404
Surgical Outcomes of Modified Technique for Transcutaneous Bone Conduction Hearing Aid Implantation
Objective: To detail a modified surgical technique for implantation of the Osia 2 Bone Conduction Hearing Aid (BCHA) system and to assess intra‐ and postoperative outcomes of this technique.Methods: A retrospective review was performed for cases undergoing implantation of an Osia 2 BCHA at a tertiary academic medical center. Modifications were made to the surgical procedure including: horizontal or curvilinear incisions, placement of the osseointegrated screw slightly superior to the plane of the external auditory canal, and double layer wound closure. Data regarding outcomes including demographics, incision type, surgical time, drilling requirements, and complications were collected using the electronic medical record.Results: A total of twenty‐eight cases were evaluated with 57.1% and 42.9% utilizing horizontal and curved incisions, respectively. The median age for recipients was 43.1 years with six pediatric cases included in the study. Median operative time was 58 min (43–126 min). The majority of cases required minimal (60.7%) or no drilling (28.6%) with a significant increase in operative time for those requiring moderate drilling versus minimal to no drilling (F = 8.02, p = 0.002). There were no intraoperative complications. One (3.6%) postoperative seroma occurred which resolved with conservative management.Conclusion: The proposed modified surgical technique is a safe and effective method for implantation of the transcutaneous BCHA system with a low complication rate. Keys include incision design, implant placement, and two‐layered closure to minimize wound tension. These modifications can improve ease of the procedure and reduce operative time. These techniques also appear to be applicable to the pediatric population.Level of Evidence: 3 Laryngoscope, 134:2401–2404, 2024
- 27 December 2023
- Published by Wiley in The Laryngoscope
- Vol. 134 (5) , 2401-2404
Surgical Outcomes of Modified Technique for Transcutaneous Bone Conduction Hearing Aid Implantation
Objective: To detail a modified surgical technique for implantation of the Osia 2 Bone Conduction Hearing Aid (BCHA) system and to assess intra‐ and postoperative outcomes of this technique.Methods: A retrospective review was performed for cases undergoing implantation of an Osia 2 BCHA at a tertiary academic medical center. Modifications were made to the surgical procedure including: horizontal or curvilinear incisions, placement of the osseointegrated screw slightly superior to the plane of the external auditory canal, and double layer wound closure. Data regarding outcomes including demographics, incision type, surgical time, drilling requirements, and complications were collected using the electronic medical record.Results: A total of twenty‐eight cases were evaluated with 57.1% and 42.9% utilizing horizontal and curved incisions, respectively. The median age for recipients was 43.1 years with six pediatric cases included in the study. Median operative time was 58 min (43–126 min). The majority of cases required minimal (60.7%) or no drilling (28.6%) with a significant increase in operative time for those requiring moderate drilling versus minimal to no drilling (F = 8.02, p = 0.002). There were no intraoperative complications. One (3.6%) postoperative seroma occurred which resolved with conservative management.Conclusion: The proposed modified surgical technique is a safe and effective method for implantation of the transcutaneous BCHA system with a low complication rate. Keys include incision design, implant placement, and two‐layered closure to minimize wound tension. These modifications can improve ease of the procedure and reduce operative time. These techniques also appear to be applicable to the pediatric population.Level of Evidence: 3 Laryngoscope, 134:2401–2404, 2024
- 19 July 2023
- Published by Wiley in The Laryngoscope
- Vol. 134 (2) , 919-925
Long‐Term Perceived Benefit of Pediatric Cochlear Implant Users with Unilateral Hearing Loss
Objective: To assess the perceived benefit of cochlear implant (CI) use for children with unilateral hearing loss (UHL) and evaluate whether perceived abilities are associated with performance on measures of speech recognition and spatial hearing.Method: Nineteen children with moderate‐to‐profound UHL underwent cochlear implantation. The Speech Spatial and Qualities of Hearing Questionnaire modified for children (SSQ‐C) were completed by parental proxy pre‐operatively and at 3, 6, 9, 12, 18, and 24 months post‐activation. Linear mixed models evaluated perceived benefits over the study period. Pearson correlations assessed the association between subjective report and performance on measures of word recognition with the CI alone and spatial hearing (speech recognition in spatially‐separated noise and sound source localization) in the combined condition (CI plus contralateral ear).Results: For the SSQ‐C, parents reported significant improvements with CI use as compared to pre‐operative perceptions (p < 0.001); improved perceptions were either maintained or continued to improve over the 2‐year post‐activation period. Perceived benefit did not significantly correlate with word recognition with the CI alone or spatial hearing outcomes in the combined condition.Conclusion: Families of children with UHL observed benefits of CI use early after cochlear implantation that was maintained with long‐term device use. Responses to subjective measures may broaden our understanding of the experiences of pediatric CI users with UHL in addition to outcomes on typical measures of CI performance.Level of Evidence: 3 Laryngoscope, 134:919–925, 2024
- 19 July 2023
- Published by Wiley in The Laryngoscope
- Vol. 134 (2) , 919-925
Long‐Term Perceived Benefit of Pediatric Cochlear Implant Users with Unilateral Hearing Loss
Objective: To assess the perceived benefit of cochlear implant (CI) use for children with unilateral hearing loss (UHL) and evaluate whether perceived abilities are associated with performance on measures of speech recognition and spatial hearing.Method: Nineteen children with moderate‐to‐profound UHL underwent cochlear implantation. The Speech Spatial and Qualities of Hearing Questionnaire modified for children (SSQ‐C) were completed by parental proxy pre‐operatively and at 3, 6, 9, 12, 18, and 24 months post‐activation. Linear mixed models evaluated perceived benefits over the study period. Pearson correlations assessed the association between subjective report and performance on measures of word recognition with the CI alone and spatial hearing (speech recognition in spatially‐separated noise and sound source localization) in the combined condition (CI plus contralateral ear).Results: For the SSQ‐C, parents reported significant improvements with CI use as compared to pre‐operative perceptions (p < 0.001); improved perceptions were either maintained or continued to improve over the 2‐year post‐activation period. Perceived benefit did not significantly correlate with word recognition with the CI alone or spatial hearing outcomes in the combined condition.Conclusion: Families of children with UHL observed benefits of CI use early after cochlear implantation that was maintained with long‐term device use. Responses to subjective measures may broaden our understanding of the experiences of pediatric CI users with UHL in addition to outcomes on typical measures of CI performance.Level of Evidence: 3 Laryngoscope, 134:919–925, 2024
- 22 February 2022
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 156, 111072
Hearing loss patterns in enlarged vestibular aqueduct syndrome: Do fluctuations have clinical significance?
- 22 February 2022
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 156, 111072
Hearing loss patterns in enlarged vestibular aqueduct syndrome: Do fluctuations have clinical significance?
- 14 February 2022
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 155, 111067
Assessing the clinical utility of volumetric HRCT in pediatric enlarged vestibular aqueduct related hearing loss
- 14 February 2022
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 155, 111067
Assessing the clinical utility of volumetric HRCT in pediatric enlarged vestibular aqueduct related hearing loss
- Open Access
- 1 February 2019
- Published by Elsevier in Archives of Biochemistry and Biophysics
- Vol. 662, 143-150
The effects of the ketone body β-hydroxybutyrate on isolated rat ventricular myocyte excitation-contraction coupling
- 1 February 2019
- Published by Elsevier in Archives of Biochemistry and Biophysics
- Vol. 662, 143-150
Open AccessThe effects of the ketone body β-hydroxybutyrate on isolated rat ventricular myocyte excitation-contraction coupling