SKStephan Kuschel

Stephan Kuschel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Stephan Kuschel has a total of 314 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Nonlinear reversal of photoexcitation on the attosecond time scale improves ultrafast X-ray diffraction images

    by Anatoli Ulmer, Phay J. Ho, Bruno Langbehn, Stephan Kuschel, Linos Hecht, Razib Obaid, Simon Dold, Taran Driver, Joseph Duris, Ming-Fu Lin, et al.

    The complex refractive index of a material governs its light-matter interactions, with intense light fields enabling tailored nonlinear optical responses. In the X-ray regime, rapid photoionization limits the potential of nonlinear techniques by inducing irreversible electronic damage. Here we demonstrate that intense, sub-femtosecond X-ray pulses, shorter than typical Auger decay times, can partially reverse photoexcitation via stimulated emission near atomic resonances. By analyzing thousands of coherent diffraction patterns and ion spectra from neon nanoparticles exposed to sub-fs and 15-fs pulses, we observe enhanced X-ray diffraction alongside reduced energy absorption for sub-fs pulses. Theoretical modeling attributes this to dynamics akin to Rabi flopping that prolong the lifetime of resonant states and suppress electronic bleaching. These findings suggest that ultrashort, intense X-ray pulses enable active control of X-ray refractive index and damage pathways, opening avenues for improved high-resolution imaging and nonlinear spectroscopy in complex nanoscale systems.


  • Open Access

    Determination of few femtosecond to attosecond electron bunch durations using a passive plasma lens

    by Andreas Seidel, Carola Zepter, Alexander Sävert, Stephan Kuschel, Matt Zepf

    Determining the pulse duration of femtosecond electron bunches is challenging and often experimentally invasive. An effective method for measuring the duration based on the time-dependent variations in electron beam divergence induced by a passive plasma lens is described. Reconstruction of the temporal shape of the electron bunch down to c × d t = 10 n m ( ∼ 30 a s ) without external RF cavities or multioctave spanning spectrometer is shown numerically. Experimental data from an ∼ 3 fs electron bunch demonstrates practical applicability of this method. While this approach can be used with any high-current electron beam, it is particularly well suited to laser-driven and particle-driven wakefield accelerators, which accommodate electron beams with a time-dependent beam energy (e.g., “chirp”).

  • Open Access

    Experimental study of laser plasma instabilities with broadband laser pulses at the GSI PHELIX laser facility

    by C Kanstein, F Wasser, Ş Zähter, S Atzeni, G Benincasa, G Cristoforetti, G Erdogdu, M Fischer, L A Gizzi, K Glize, et al.

    We present first experimental data obtained at the recently commissioned experimental platform to compare laser plasma instabilities (LPIs) driven by monochromatic and broad spectral bandwidth ( ≈ 0.5 % ) laser pulses with a wavelength of around 527 nm. The evaluation of LPIs at 10 15 W cm −2 is shown by utilizing a full aperture backscatter diagnostic and side scatter diagnostics. For a broad bandwidth, our study indicates a suppression of stimulated Brillouin back- and side scattering as well as of the two plasmon decay instability, but an increase of stimulated Raman side scattering. An increase in both temperature and numbers of hot electrons is also identified by direct and indirect measurements.


  • Open Access

    Determination of few femtosecond to attosecond electron bunch durations using a passive plasma lens

    by Andreas Seidel, Carola Zepter, Alexander Sävert, Stephan Kuschel, Matt Zepf

    Determining the pulse duration of femtosecond electron bunches is challenging and often experimentally invasive. An effective method for measuring the duration based on the time-dependent variations in electron beam divergence induced by a passive plasma lens is described. Reconstruction of the temporal shape of the electron bunch down to $c \cdot dt=10$ nm ($\sim 30$ as) without external RF-cavities or multi-octave spanning spectrometer is shown numerically. Experimental data from a $\sim$ 3fs electron bunch demonstrates practical applicability of this method. While this approach can be used with any high current electron beam, it is particularly well matched to laser-driven and particle-driven wakefield accelerators and also accommodates electron beams with a time-dependent beam-energy (eg. 'chirp').

  • Top Cited Papers
    Open Access

    Non-linear enhancement of ultrafast X-ray diffraction through transient resonances

    by Stephan Kuschel, Phay J. Ho, Andre Al Haddad, Felix F. Zimmermann, Leonie Flueckiger, Matthew R. Ware, Joseph Duris, James P. MacArthur, Alberto Lutman, Ming-Fu Lin, et al.

    Diffraction-before-destruction imaging with ultrashort X-ray pulses can visualize non-equilibrium processes, such as chemical reactions, with sub-femtosecond precision in the native environment. Here, a nanospecimen diffracts a single X-ray flash before it disintegrates. The sample structure can be reconstructed from the coherent diffraction image (CDI). State-of-the-art X-ray snapshots lack high spatial resolution because of weak diffraction signal. Bleaching effects from photo-ionization significantly restrain image brightness scaling. We find that non-linear transient ion resonances can overcome this barrier if X-ray laser pulses are shorter than in most experiments. We compared snapshots from individual ≈ 100 nm Xe nanoparticles as a function of pulse duration and incoming X-ray fluence. Our experimental results and Monte Carlo simulations suggest that transient resonances can increase ionic scattering cross sections significantly beyond literature values. This provides a novel avenue towards substantial improvement of the spatial resolution in CDI in combination with sub-femtosecond temporal precision at the nanoscale.


  • A spectrometer for ultrashort gamma-ray pulses with photon energies greater than 10 MeV

    by K. T. Behm, J. M. Cole, A. S. Joglekar, E. Gerstmayr, J. C. Wood, C. D. Baird, T. G. Blackburn, M. Duff, C. Harvey, A. Ilderton, et al.

    We present a design for a pixelated scintillator based gamma-ray spectrometer for non-linear inverse Compton scattering experiments. By colliding a laser wakefield accelerated electron beam with a tightly focused, intense laser pulse, gamma-ray photons up to 100 MeV energies and with few femtosecond duration may be produced. To measure the energy spectrum and angular distribution, a 33 × 47 array of cesium-iodide crystals was oriented such that the 47 crystal length axis was parallel to the gamma-ray beam and the 33 crystal length axis was oriented in the vertical direction. Using an iterative deconvolution method similar to the YOGI code, modeling of the scintillator response using GEANT4 and fitting to a quantum Monte Carlo calculated photon spectrum, we are able to extract the gamma ray spectra generated by the inverse Compton interaction.


  • Open Access

    Progress on experiments towards LWFA-driven transverse gradient undulator-based FELs

    by A. Bernhard, V. Afonso Rodríguez, S. Kuschel, M. Leier, P. Peiffer, A. Sävert, M. Schwab, W. Werner, C. Widmann, A. Will, et al.


  • Open Access

    Controlling the Self-Injection Threshold in Laser Wakefield Accelerators

    by S. Kuschel, M. B. Schwab, M. Yeung, D. Hollatz, A. Seidel, W. Ziegler, A. Sävert, M. C. Kaluza, M. Zepf

    Controlling the parameters of a laser plasma accelerated electron beam is a topic of intense research with a particular focus placed on controlling the injection phase of electrons into the accelerating structure from the background plasma. An essential prerequisite for high-quality beams is dark-current free acceleration (i.e., no electrons accelerated beyond those deliberately injected). We show that small-scale density ripples in the background plasma are sufficient to cause the uncontrolled (self-)injection of electrons. Such ripples can be as short as ∼50  μm and can therefore not be resolved by standard interferometry. Background free injection with substantially improved beam characteristics (divergence and pointing) is demonstrated in a gas cell designed for a controlled gas flow. The results are supported by an analytical theory as well as 3D particle in cell simulations.


  • Calibration and cross-laboratory implementation of scintillating screens for electron bunch charge determination

    by Thomas Kurz, Jurjen Pieter Couperus, Jakob Matthias Krämer, Hao Ding, Stephan Kuschel, Alexander Köhler, Omid Zarini, Dominik Hollatz, David Schinkel, Richard D’aRcy, et al.

    We revise the calibration of scintillating screens commonly used to detect relativistic electron beams with low average current, e.g., from laser-plasma accelerators, based on new and expanded measurements that include higher charge density and different types of screens than previous work [Buck et al., Rev. Sci. Instrum. 81, 033301 (2010)]. Electron peak charge densities up to 10 nC/mm2 were provided by focused picosecond-long electron beams delivered by the Electron Linac for beams with high Brilliance and low Emittance (ELBE) at the Helmholtz-Zentrum Dresden-Rossendorf. At low charge densities, a linear scintillation response was found, followed by the onset of saturation in the range of nC/mm2. The absolute calibration factor (photons/sr/pC) in this linear regime was measured to be almost a factor of 2 lower than that reported by Buck et al. retrospectively implying a higher charge in the charge measurements performed with the former calibration. A good agreement was found with the results provided by Glinec et al. [Rev. Sci. Instrum. 77, 103301 (2006)]. Furthermore long-term irradiation tests with an integrated dose of approximately 50 nC/mm2 indicate a significant decrease of the scintillation efficiency over time. Finally, in order to enable the transfer of the absolute calibration between laboratories, a new constant reference light source has been developed.