Juan Gabriel Barra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Juan Gabriel Barra has a total of 118 co-authors. Here are the top co-authors by number of shared publications:
- Ricardo Luis Armentano
Living Systems Engineering Lab., Department of Biological Engineering, CenUR LN Universidad de la República 1 , Montevideo, Uruguay
14 shared publications - Damian Craiem
Instituto de Medicina Traslacional, Trasplante y Bioingeniería (IMETTyB), Universidad Favaloro-CONICET, Buenos Aires, Argentina
11 shared publications - Alberto Crottogini
Department of Physiology, Favaloro University, Buenos Aires, Argentina
9 shared publications Alain Simon
7 shared publicationsJaime Levenson
7 shared publicationsR H Pichel
Basic Sciences Research Center, University Institute of Biomedical Sciences, Favaloro Foundation, Buenos Aires, Argentina
6 shared publications
Latest Publications
- Open Access
- 31 December 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 477 (1) , 012030
Contribution of arterial tree structure to the arterial pressure fractal behavior
Arterial vascular beds can be characterized considering the arterial segments in terms of their physical properties. These and other trees have an open structure based on repeated bifurcations, following fractal rules. Fractal dimension (FD) quantifies the time series complexity defined by its geometrical representation. Objective: To evaluate the arterial pressure and diameter time series in order to assess the influence of arterial tree structure in arterial pressure fractal dimension (FD). Methods: Simultaneous aortic pressure and diameter were measured in 14 conscious dogs. A pair of ultrasonic crystals, a pressure microtransducer and a pneumatic cuff occluder were positioned in the upper third of the descending aorta. Results: Total reflection induced by the occlusion maneuver decreased FD concomitant to the aortic stiffening and early wave reflection. Conclusion: Arterial pressure fractality is highly dependent on the arterial tree structure.
- 31 December 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 477 (1) , 012030
Open AccessContribution of arterial tree structure to the arterial pressure fractal behavior
Arterial vascular beds can be characterized considering the arterial segments in terms of their physical properties. These and other trees have an open structure based on repeated bifurcations, following fractal rules. Fractal dimension (FD) quantifies the time series complexity defined by its geometrical representation. Objective: To evaluate the arterial pressure and diameter time series in order to assess the influence of arterial tree structure in arterial pressure fractal dimension (FD). Methods: Simultaneous aortic pressure and diameter were measured in 14 conscious dogs. A pair of ultrasonic crystals, a pressure microtransducer and a pneumatic cuff occluder were positioned in the upper third of the descending aorta. Results: Total reflection induced by the occlusion maneuver decreased FD concomitant to the aortic stiffening and early wave reflection. Conclusion: Arterial pressure fractality is highly dependent on the arterial tree structure.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2013 (1094687X) , 1960-1963
Arterial pressure fractality is highly dependent on wave reflection
Wave reflection is an important factor that influences pressure wave morphology and becomes more significant with aging, when cardiovascular risk increases. A pressure wave, measured at any location in the arterial tree, can be decomposed into its forward and backward components and depends on the corresponding amplitude and shifting time delays. Fractal dimension (FD) quantifies the time series complexity defined by its geometrical representation. Objective: The aim of this study was to evaluate the arterial pressure and diameter time series in order to assess the relationship between wave reflection and arterial pressure fractal dimension (FD). Methods: Simultaneous aortic pressure and diameter were measured in 14 conscious dogs. A pair of ultrasonic crystals, a pressure microtransducer and a pneumatic cuff occluder were positioned in the upper third of the descending aorta. Results: Total reflection induced by the occlusion maneuver decreased FD concomitant to the aortic stiffening. Conclusion: Arterial pressure fractality is highly dependent on wave reflection.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2013 (1094687X) , 1960-1963
Arterial pressure fractality is highly dependent on wave reflection
Wave reflection is an important factor that influences pressure wave morphology and becomes more significant with aging, when cardiovascular risk increases. A pressure wave, measured at any location in the arterial tree, can be decomposed into its forward and backward components and depends on the corresponding amplitude and shifting time delays. Fractal dimension (FD) quantifies the time series complexity defined by its geometrical representation. Objective: The aim of this study was to evaluate the arterial pressure and diameter time series in order to assess the relationship between wave reflection and arterial pressure fractal dimension (FD). Methods: Simultaneous aortic pressure and diameter were measured in 14 conscious dogs. A pair of ultrasonic crystals, a pressure microtransducer and a pneumatic cuff occluder were positioned in the upper third of the descending aorta. Results: Total reflection induced by the occlusion maneuver decreased FD concomitant to the aortic stiffening. Conclusion: Arterial pressure fractality is highly dependent on wave reflection.
- 1 January 2013
- Published by Springer Nature
- p. 798-801
Estudio de la Variabilidad de las Propiedades Mecánicas Arteriales en 24 horas: Prueba Preliminar en Oveja Consciente
- 1 January 2013
- Published by Springer Nature
- p. 798-801
Estudio de la Variabilidad de las Propiedades Mecánicas Arteriales en 24 horas: Prueba Preliminar en Oveja Consciente
- 18 December 2012
- Published by IOP Publishing in Physiological Measurement
- Vol. 34 (1) , 83-97
Fractal dimension as an index of left ventricular ischaemia: a pilot study
Myocardial perfusion is performed by the left and the right coronary arteries, which deliver blood to the left and right ventricles, respectively. The impairment of arterial flow supply to the cardiac muscle by disease denotes a phenomenon known as ischaemia. Previous studies have demonstrated the ability of fractal dimension (FD) value of a physiological parameter in differentiating healthy/pathological behaviours. The aim of this study consisted in quantifying the loss of ventricular thickness fractal complexity in order to determine if FD is an intrinsic marker of acute coronary ischaemia. Five mongrel dogs weighing 18.8-26.5 kg (24.4 ± 3.3, mean ± SD) were submitted to this studio. A left ventricular pressure transducer and a fluid-filled catheter for later calibration of the pressure transducer were introduced through a stab wound near the apex. Two pairs of ultrasonic microcrystals (5 MHz) for continuous wall thickness measurements were implanted at the anterior and posterior walls of the left ventricle following a previously described technique. During coronary occlusion, the ischemic wall started to thin at the very onset of relaxation (showing abnormal motility), while the normoperfused wall displayed postejective thickening. Concomitantly, posterior ventricular wall thickness and anterior wall ventricular thickness showed a significant decrease in its FD value (P <0.05). In conclusion, loss of time series fractal complexity (waveform fine structure diminution or 'unwrinkling') constitutes a marker of the presence of an ischemic process. As a result, a single scalar value is sufficient to characterize the entire behaviour of the time series. This value manifested a similar trend compared to the most well-known clinical indices of myocardial ischaemia.
- 18 December 2012
- Published by IOP Publishing in Physiological Measurement
- Vol. 34 (1) , 83-97
Fractal dimension as an index of left ventricular ischaemia: a pilot study
Myocardial perfusion is performed by the left and the right coronary arteries, which deliver blood to the left and right ventricles, respectively. The impairment of arterial flow supply to the cardiac muscle by disease denotes a phenomenon known as ischaemia. Previous studies have demonstrated the ability of fractal dimension (FD) value of a physiological parameter in differentiating healthy/pathological behaviours. The aim of this study consisted in quantifying the loss of ventricular thickness fractal complexity in order to determine if FD is an intrinsic marker of acute coronary ischaemia. Five mongrel dogs weighing 18.8-26.5 kg (24.4 ± 3.3, mean ± SD) were submitted to this studio. A left ventricular pressure transducer and a fluid-filled catheter for later calibration of the pressure transducer were introduced through a stab wound near the apex. Two pairs of ultrasonic microcrystals (5 MHz) for continuous wall thickness measurements were implanted at the anterior and posterior walls of the left ventricle following a previously described technique. During coronary occlusion, the ischemic wall started to thin at the very onset of relaxation (showing abnormal motility), while the normoperfused wall displayed postejective thickening. Concomitantly, posterior ventricular wall thickness and anterior wall ventricular thickness showed a significant decrease in its FD value (P <0.05). In conclusion, loss of time series fractal complexity (waveform fine structure diminution or 'unwrinkling') constitutes a marker of the presence of an ischemic process. As a result, a single scalar value is sufficient to characterize the entire behaviour of the time series. This value manifested a similar trend compared to the most well-known clinical indices of myocardial ischaemia.
- 23 December 2011
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 332
Estimation of local pulse wave velocity using arterial diameter waveforms: Experimental validation in sheep
- 23 December 2011
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 332
Estimation of local pulse wave velocity using arterial diameter waveforms: Experimental validation in sheep
- 23 December 2011
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 332
Mechanical properties of the aortic arterial wall during 24 hours: a preliminary study in conscious sheep
- 23 December 2011
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 332
Mechanical properties of the aortic arterial wall during 24 hours: a preliminary study in conscious sheep
- 3 November 2011
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 3 (1) , 80-87
Vascular Smooth Muscle Activation Improves Aortic Compliance with Respect to Mechanical Loading
- 3 November 2011
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 3 (1) , 80-87
Vascular Smooth Muscle Activation Improves Aortic Compliance with Respect to Mechanical Loading
- 1 August 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2010 (1094687X) , 3788-3791
A patient-specific method for the evaluation of wall shear stress in human coronary arteries
Atherosclerotic plaques form at specific sites of the arterial tree, an observation that has led to the "geometric risk factor" hypothesis for atherogenesis. It is accepted that the location of atherosclerotic plaques is correlated with sites subjected to low abnormal values of wall shear stress (WSS), which is in turn determined by the specific geometry of the arterial segment. In particular, the left coronary artery (LCA) is one of the most important sites of plaque formation and its progression may lead to stroke. However, little is known about hemodynamics and WSS distributions in the LCA. The purpose of this work is to set up a method to evaluate flow patterns and WSS distributions in the human LCA based on real patient-specific geometries reconstructed from medical images. A three-dimensional model of the LCA of a healthy patient was reconstructed based on a computer tomography (CT) study. A finite element volume mesh was constructed and blood flow trough it was modeled with the finite element method. WSS distribution was computed with later postprocessing. Results showed that the particular details of the geometry such as curvatures and branching produced flow disturbances and determined in last the WSS distribution. Specific regions of low WSS values were determined. This work shows the feasibility of developing a patient-specific method for evaluating flow pattern and WSS distributions in order to study atherosclerotic plaque formation in the human LCA with real geometries obtained from CT images processing.
- 1 August 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2010 (1094687X) , 3788-3791
A patient-specific method for the evaluation of wall shear stress in human coronary arteries
Atherosclerotic plaques form at specific sites of the arterial tree, an observation that has led to the "geometric risk factor" hypothesis for atherogenesis. It is accepted that the location of atherosclerotic plaques is correlated with sites subjected to low abnormal values of wall shear stress (WSS), which is in turn determined by the specific geometry of the arterial segment. In particular, the left coronary artery (LCA) is one of the most important sites of plaque formation and its progression may lead to stroke. However, little is known about hemodynamics and WSS distributions in the LCA. The purpose of this work is to set up a method to evaluate flow patterns and WSS distributions in the human LCA based on real patient-specific geometries reconstructed from medical images. A three-dimensional model of the LCA of a healthy patient was reconstructed based on a computer tomography (CT) study. A finite element volume mesh was constructed and blood flow trough it was modeled with the finite element method. WSS distribution was computed with later postprocessing. Results showed that the particular details of the geometry such as curvatures and branching produced flow disturbances and determined in last the WSS distribution. Specific regions of low WSS values were determined. This work shows the feasibility of developing a patient-specific method for evaluating flow pattern and WSS distributions in order to study atherosclerotic plaque formation in the human LCA with real geometries obtained from CT images processing.
- 1 March 2010
- Published by Wolters Kluwer Health in Journal of Cardiovascular Pharmacology
- Vol. 55 (3) , 255-261
Long-Term Effects of Growth Hormone on Infarct Size and Left Ventricular Function in Sheep With Coronary Artery Occlusion
The effects of growth hormone (GH) on infarct size and left ventricular (LV) function in experimental acute myocardial infarction (AMI) have been controversial. Moreover, little, if any, information exists regarding long-term evaluation of therapeutic doses of GH in large mammalian models of AMI. We therefore aimed to assess the effect of therapeutic doses of GH over 3.5 months on infarct size and heart function in sheep with AMI. After coronary artery ligation, sheep received subcutaneous human GH 8 IU/d (n = 8) or vehicle (n = 8) over 100 days. Infarct area was similar in GH (16.9% ± 3% of LV area) and placebo (16.5% ± 3.7%, P = not significant) sheep. At 3 days of treatment onset, but not at later times, GH sheep had higher LV shortening fraction (30.7% ± 3.5% vs. 24.8% ± 6.1%, P < 0.04), systolic anterior wall thickness (10.1 ± 0.8 vs. 8.6 ± 1.2 mm, P < 0.02), and cardiac index (3.8 ± 0.6 vs. 2.8 ± 0.7 L·min−1·m−2, P < 0.01). This evolution of function parameters paralleled that of serum insulin-like growth factor 1 levels, which differed significantly only during the first week, suggesting a direct effect of GH on LV contractility. These results may suggest the usefulness of therapeutic doses of GH at the early phases of AMI but do not support maintaining the treatment for longer time.
- 1 March 2010
- Published by Wolters Kluwer Health in Journal of Cardiovascular Pharmacology
- Vol. 55 (3) , 255-261
Long-Term Effects of Growth Hormone on Infarct Size and Left Ventricular Function in Sheep With Coronary Artery Occlusion
The effects of growth hormone (GH) on infarct size and left ventricular (LV) function in experimental acute myocardial infarction (AMI) have been controversial. Moreover, little, if any, information exists regarding long-term evaluation of therapeutic doses of GH in large mammalian models of AMI. We therefore aimed to assess the effect of therapeutic doses of GH over 3.5 months on infarct size and heart function in sheep with AMI. After coronary artery ligation, sheep received subcutaneous human GH 8 IU/d (n = 8) or vehicle (n = 8) over 100 days. Infarct area was similar in GH (16.9% ± 3% of LV area) and placebo (16.5% ± 3.7%, P = not significant) sheep. At 3 days of treatment onset, but not at later times, GH sheep had higher LV shortening fraction (30.7% ± 3.5% vs. 24.8% ± 6.1%, P < 0.04), systolic anterior wall thickness (10.1 ± 0.8 vs. 8.6 ± 1.2 mm, P < 0.02), and cardiac index (3.8 ± 0.6 vs. 2.8 ± 0.7 L·min−1·m−2, P < 0.01). This evolution of function parameters paralleled that of serum insulin-like growth factor 1 levels, which differed significantly only during the first week, suggesting a direct effect of GH on LV contractility. These results may suggest the usefulness of therapeutic doses of GH at the early phases of AMI but do not support maintaining the treatment for longer time.
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (1094687X) , 2847-2850
Assessment of pulsatile wall shear stress in compliant arteries: Numerical model, validation and experimental data
There is evidence that wall shear stress (WSS) is associated with vascular disease. In particular, it is widely accepted that vascular segments with low or oscillatory values of WSS are more probable to develop vascular disease. It is then necessary to establish a realistic model of the blood flow in blood vessels in order to determine precisely WSS. We proposed a numerical 1D model which takes into account the pulsatile nature of blood flow, the elasticity of the vessel, and its geometry. The model allows the calculation of shear stress. It was validated for stationary situations. Then, we computed the time-dependent WSS distribution from experimental data in the sheep thoracic aorta. Results showed that mean WSS calculated through steady flow and rigid walls models is overestimated. Peak WSS values for pulsatile flow must be considered since they resulted to be at least one order higher than mean values. Oscillations in shear stress in a period showed to be approximately of 40%. These findings show that the proposed model is suitable for estimating time-dependent WSS distributions, and confirm the need of using this kind of model when trying to evaluate realistic WSS in blood vessels.
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (1094687X) , 2847-2850
Assessment of pulsatile wall shear stress in compliant arteries: Numerical model, validation and experimental data
There is evidence that wall shear stress (WSS) is associated with vascular disease. In particular, it is widely accepted that vascular segments with low or oscillatory values of WSS are more probable to develop vascular disease. It is then necessary to establish a realistic model of the blood flow in blood vessels in order to determine precisely WSS. We proposed a numerical 1D model which takes into account the pulsatile nature of blood flow, the elasticity of the vessel, and its geometry. The model allows the calculation of shear stress. It was validated for stationary situations. Then, we computed the time-dependent WSS distribution from experimental data in the sheep thoracic aorta. Results showed that mean WSS calculated through steady flow and rigid walls models is overestimated. Peak WSS values for pulsatile flow must be considered since they resulted to be at least one order higher than mean values. Oscillations in shear stress in a period showed to be approximately of 40%. These findings show that the proposed model is suitable for estimating time-dependent WSS distributions, and confirm the need of using this kind of model when trying to evaluate realistic WSS in blood vessels.