Nur Dalilah Nordin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nur Dalilah Nordin has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Hasimah Abdul Rahman
4 shared publicationsHasimah Abd Rahman
1 shared publication- Hasimah Abdul Rahman
Universiti Teknologi Malaysia
1 shared publication - Hasimah Abdul Rahman
Centre of Electrical Energy Systems, Institute of Future Energy, Universiti Teknologi Malaysia, 81300, Johor, Malaysia
1 shared publication
Latest Publications
- 1 October 2019
- Published by Elsevier in Renewable Energy
- Vol. 141, 107-123
Comparison of optimum design, sizing, and economic analysis of standalone photovoltaic/battery without and with hydrogen production systems
- 1 October 2019
- Published by Elsevier in Renewable Energy
- Vol. 141, 107-123
Comparison of optimum design, sizing, and economic analysis of standalone photovoltaic/battery without and with hydrogen production systems
- Open Access
- 9 November 2017
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 93 (1) , 012068
Sizing and economic analysis of stand alone photovoltaic system with hydrogen storage
- 9 November 2017
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 93 (1) , 012068
Open AccessSizing and economic analysis of stand alone photovoltaic system with hydrogen storage
- Open Access
- 11 August 2016
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 70, 10005
Optimal Sizing of Decentralized Photovoltaic Generation and Energy Storage Units for Malaysia Residential Household Using Iterative Method
World's fuel sources are decreasing, and global warming phenomena cause the necessity of urgent search for alternative energy sources. Photovoltaic generating system has a high potential, since it is clean, environmental friendly and secure energy sources. This paper presents an optimal sizing of decentralized photovoltaic system and electrical energy storage for a residential household using iterative method. The cost of energy, payback period, degree of autonomy and degree of own-consumption are defined as optimization parameters. A case study is conducted by employing Kuala Lumpur meteorological data, typical load profile from rural area in Malaysia, decentralized photovoltaic generation unit and electrical storage and it is analyzed in hourly basis. An iterative method is used with photovoltaic array variable from 0.1kW to 4.0kW and storage system variable from 50Ah to 400Ah was performed to determine the optimal design for the proposed system.
- 11 August 2016
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 70, 10005
Open AccessOptimal Sizing of Decentralized Photovoltaic Generation and Energy Storage Units for Malaysia Residential Household Using Iterative Method
World's fuel sources are decreasing, and global warming phenomena cause the necessity of urgent search for alternative energy sources. Photovoltaic generating system has a high potential, since it is clean, environmental friendly and secure energy sources. This paper presents an optimal sizing of decentralized photovoltaic system and electrical energy storage for a residential household using iterative method. The cost of energy, payback period, degree of autonomy and degree of own-consumption are defined as optimization parameters. A case study is conducted by employing Kuala Lumpur meteorological data, typical load profile from rural area in Malaysia, decentralized photovoltaic generation unit and electrical storage and it is analyzed in hourly basis. An iterative method is used with photovoltaic array variable from 0.1kW to 4.0kW and storage system variable from 50Ah to 400Ah was performed to determine the optimal design for the proposed system.
- 1 April 2016
- Published by Elsevier in Renewable Energy
- Vol. 89, 706-715
A novel optimization method for designing stand alone photovoltaic system
- 1 April 2016
- Published by Elsevier in Renewable Energy
- Vol. 89, 706-715
A novel optimization method for designing stand alone photovoltaic system
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An optimization method for designing stand alone photovoltaic system using iterative method
World's fuel sources are decreasing and global warming phenomena cause the urgency to search for alternative energy sources. Photovoltaic system has high potential since it is clean and environmental friendly. Standalone photovoltaic (SAPV) system is usually chosen as an alternative to grid utility, where excess to main grid is impossible. The system is designed to fulfill a specific load demand, close to its point of utilization. This paper presents SAPV system sizing and design that include sizing of PV modules, battery storages, charge controller and inverter using iterative method. Loss of power supply probability analysis is set as a benchmark to determine all possible configurations. Then, the optimum design is chosen based on the lowest levelized cost of energy. A case study on small-scale household load profile and hourly solar irradiance is employed to design this system. The findings indicate that the annual LCC for the proposed system is RM 632.08 with LCOE of RM 0.79/kWh.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An optimization method for designing stand alone photovoltaic system using iterative method
World's fuel sources are decreasing and global warming phenomena cause the urgency to search for alternative energy sources. Photovoltaic system has high potential since it is clean and environmental friendly. Standalone photovoltaic (SAPV) system is usually chosen as an alternative to grid utility, where excess to main grid is impossible. The system is designed to fulfill a specific load demand, close to its point of utilization. This paper presents SAPV system sizing and design that include sizing of PV modules, battery storages, charge controller and inverter using iterative method. Loss of power supply probability analysis is set as a benchmark to determine all possible configurations. Then, the optimum design is chosen based on the lowest levelized cost of energy. A case study on small-scale household load profile and hourly solar irradiance is employed to design this system. The findings indicate that the annual LCC for the proposed system is RM 632.08 with LCOE of RM 0.79/kWh.
- Open Access
- 1 April 2015
- Published by Elsevier in Energy Procedia
- Vol. 68, 68-76
Pre-installation Design Simulation Tool for Grid-connected Photovoltaic System Using Iterative Methods
- 1 April 2015
- Published by Elsevier in Energy Procedia
- Vol. 68, 68-76
Open AccessPre-installation Design Simulation Tool for Grid-connected Photovoltaic System Using Iterative Methods
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 152-157
Design and economic analysis in stand alone photovoltaic system
Photovoltaic generating system has a high potential, since it is clean, environmental friendly and secure energy sources. Stand alone photovoltaic system is chosen as an alternative to grid utility where excess to utility is impossible especially in remote area. In stand alone photovoltaic system, the system is designed to fulfill a specific load demand, normally close to its point of utilization. This paper describes the design steps in stand alone photovoltaic system that include sizing of PV modules, battery storages, charge controller and inverter. An economic analysis was performed to identify system practicality based on predefined load. The finding shows that the levelized cost of energy for proposed system is RM 1.76/kWh.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 152-157
Design and economic analysis in stand alone photovoltaic system
Photovoltaic generating system has a high potential, since it is clean, environmental friendly and secure energy sources. Stand alone photovoltaic system is chosen as an alternative to grid utility where excess to utility is impossible especially in remote area. In stand alone photovoltaic system, the system is designed to fulfill a specific load demand, normally close to its point of utilization. This paper describes the design steps in stand alone photovoltaic system that include sizing of PV modules, battery storages, charge controller and inverter. An economic analysis was performed to identify system practicality based on predefined load. The finding shows that the levelized cost of energy for proposed system is RM 1.76/kWh.