Amrita Ray
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Amrita Ray has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- John R. Craig
Department of Otolaryngology‐Head and Neck Surgery Henry Ford Health Detroit Michigan USA
6 shared publications - Michael J. Brenner
Department of Otolaryngology - Head and Neck Surgery, University of Michigan Medical School, Ann Arbor, MI, USA
6 shared publications - Jochen Schacht
University of Michigan
4 shared publications Jacob G. Eide
Department of Otolaryngology—Head and Neck Surgery Mayo Clinic Rochester Minnesota USA
3 shared publications- Jacob G. Eide
Department of Otolaryngology–Head and Neck Surgery Mayo Clinic Rochester Minnesota USA
3 shared publications - Abdul Yassin-Kassab
Rush University Medical Center
2 shared publications
Latest Publications
- 20 March 2025
- Published by Wiley in The Laryngoscope
- Vol. 135 (8) , 2696-2701
Rapid Intrathecal Fluorescein Injection During Cerebrospinal Fluid Leak Repair Is Safe and Effective
Objective: Intrathecal fluorescein (IF) is effective for localizing nasal cerebrospinal fluid (CSF) leaks along the skull base during endoscopic exploration, with largest studies reporting sensitivities ranging from 66%–93%. Due to reports of intraoperative and postoperative neurologic complications such as seizures and paralysis, surgeons often dilute the fluorescein and inject it intrathecally slowly over a variable amount of time. However, no study has assessed whether rapid IF administration causes the aforementioned risks or whether it affects its accuracy in identifying CSF leaks intraoperatively.Methods: A prospective study was conducted from 2015 to 2024, where all patients undergoing endoscopic exploration and/or repair of CSF rhinorrhea had 0.1 mL of 10% fluorescein (10 mg) mixed with 3–5 mL of patients' CSF injected rapidly via the lumbar drain over a few seconds.Results: Of the 82 included patients, the mean age was 53.8 ± 15.2 years, and 84% were female. Sixty‐nine patients underwent successful endoscopic CSF leak repairs, and 13 had negative endoscopic explorations. Rapid IF injection was 80% sensitive (20% false negative rate) and 100% specific for identifying CSF leaks, and it caused no seizures, paralysis, or other neurologic complications.Conclusion: Compared to prior reports of slow low‐dose IF injection for CSF leak localization, rapid IF injection yielded similar efficacy (80% sensitivity) with no IF‐related complications. Rapid IF injection was safe and effective but should be corroborated by future studies.Level of Evidence: 4.
- 20 March 2025
- Published by Wiley in The Laryngoscope
- Vol. 135 (8) , 2696-2701
Rapid Intrathecal Fluorescein Injection During Cerebrospinal Fluid Leak Repair Is Safe and Effective
Objective: Intrathecal fluorescein (IF) is effective for localizing nasal cerebrospinal fluid (CSF) leaks along the skull base during endoscopic exploration, with largest studies reporting sensitivities ranging from 66%–93%. Due to reports of intraoperative and postoperative neurologic complications such as seizures and paralysis, surgeons often dilute the fluorescein and inject it intrathecally slowly over a variable amount of time. However, no study has assessed whether rapid IF administration causes the aforementioned risks or whether it affects its accuracy in identifying CSF leaks intraoperatively.Methods: A prospective study was conducted from 2015 to 2024, where all patients undergoing endoscopic exploration and/or repair of CSF rhinorrhea had 0.1 mL of 10% fluorescein (10 mg) mixed with 3–5 mL of patients' CSF injected rapidly via the lumbar drain over a few seconds.Results: Of the 82 included patients, the mean age was 53.8 ± 15.2 years, and 84% were female. Sixty‐nine patients underwent successful endoscopic CSF leak repairs, and 13 had negative endoscopic explorations. Rapid IF injection was 80% sensitive (20% false negative rate) and 100% specific for identifying CSF leaks, and it caused no seizures, paralysis, or other neurologic complications.Conclusion: Compared to prior reports of slow low‐dose IF injection for CSF leak localization, rapid IF injection yielded similar efficacy (80% sensitivity) with no IF‐related complications. Rapid IF injection was safe and effective but should be corroborated by future studies.Level of Evidence: 4.
- 14 October 2024
- Published by Wiley in The Laryngoscope
Diagnostic Accuracy of Beta‐2 Transferrin Gel Electrophoresis for Detecting Cerebrospinal Fluid Rhinorrhea
Objective: Unilateral thin clear rhinorrhea (UTCR) may represent a variety of pathologies including cerebrospinal fluid (CSF) rhinorrhea. Beta‐2 transferrin (B2Tf) gel electrophoresis (GE) has become the preferred testing modality due to reportedly high sensitivity (87%–100%) and specificity (71%–100%). However, there have been relatively few studies assessing its diagnostic accuracy. The purpose of this single‐institution study was to determine the accuracy of B2Tf GE in detecting CSF rhinorrhea.Methods: A single‐center retrospective review was conducted from 2016 and 2024 for all patients who presented with UTCR and underwent B2Tf GE. Institutional review board approval was obtained. The gold standard for diagnostic confirmation of true and false positives (TP, FP) as well as false negatives (FN) was endoscopic exploration. The gold standard for true negative (TN) was response to medical therapy.Results: A total of 105 patients underwent 149 B2Tf GE tests. 40 (38.1%) patients were diagnosed with CSF rhinorrhea. Of the 149 B2‐Tf GE tests, there were 51 TPs, 72 TNs, 20 FPs, and 6 FNs yielding 89.5% sensitivity, 78.3% specificity, 71.8% positive predictive value, and 92.3% negative predictive value, respectively. Of the false results the most common causes for error were purulent sinusitis (n = 6, 23.1%), possible mucous contamination from nose‐blowing during collection (n = 3, 11.5%), patient collection error (n = 3, 11.5%), and blood contamination (n = 1, 3.8%).Conclusion: Although these single‐institutional data demonstrate test accuracy within ranges previously reported in the literature, they also demonstrate diagnostic limitations. Future studies should explore reasons for erroneous B2Tf GE results and how these may change clinical decision‐making.Level of Evidence: IV Laryngoscope, 2024
- 14 October 2024
- Published by Wiley in The Laryngoscope
Diagnostic Accuracy of Beta‐2 Transferrin Gel Electrophoresis for Detecting Cerebrospinal Fluid Rhinorrhea
Objective: Unilateral thin clear rhinorrhea (UTCR) may represent a variety of pathologies including cerebrospinal fluid (CSF) rhinorrhea. Beta‐2 transferrin (B2Tf) gel electrophoresis (GE) has become the preferred testing modality due to reportedly high sensitivity (87%–100%) and specificity (71%–100%). However, there have been relatively few studies assessing its diagnostic accuracy. The purpose of this single‐institution study was to determine the accuracy of B2Tf GE in detecting CSF rhinorrhea.Methods: A single‐center retrospective review was conducted from 2016 and 2024 for all patients who presented with UTCR and underwent B2Tf GE. Institutional review board approval was obtained. The gold standard for diagnostic confirmation of true and false positives (TP, FP) as well as false negatives (FN) was endoscopic exploration. The gold standard for true negative (TN) was response to medical therapy.Results: A total of 105 patients underwent 149 B2Tf GE tests. 40 (38.1%) patients were diagnosed with CSF rhinorrhea. Of the 149 B2‐Tf GE tests, there were 51 TPs, 72 TNs, 20 FPs, and 6 FNs yielding 89.5% sensitivity, 78.3% specificity, 71.8% positive predictive value, and 92.3% negative predictive value, respectively. Of the false results the most common causes for error were purulent sinusitis (n = 6, 23.1%), possible mucous contamination from nose‐blowing during collection (n = 3, 11.5%), patient collection error (n = 3, 11.5%), and blood contamination (n = 1, 3.8%).Conclusion: Although these single‐institutional data demonstrate test accuracy within ranges previously reported in the literature, they also demonstrate diagnostic limitations. Future studies should explore reasons for erroneous B2Tf GE results and how these may change clinical decision‐making.Level of Evidence: IV Laryngoscope, 2024
- 27 August 2024
- Published by Wiley in The Laryngoscope
- Vol. 135 (2) , 586-592
Maxillary Antrostomy Versus Complete Sinus Surgery for Odontogenic Sinusitis With Frontal Sinus Extension
Objectives: Endoscopic sinus surgery (ESS) is often necessary when managing odontogenic sinusitis (ODS), but ESS extent for ODS with extramaxillary sinus involvement has been incompletely studied. This study compared outcomes after wide maxillary antrostomy (MA) alone versus complete ESS for ODS with frontal sinus involvement.Methods: A multicenter prospective cohort study was conducted on patients with uncomplicated ODS (no extrasinus spread) who underwent ESS when computed tomography demonstrated maxillary, anterior ethmoid (AE), and frontal sinus opacification. Multiple preoperative and postoperative variables were recorded, including 22‐item sinonasal outcome tests (SNOT‐22) and endoscopic findings. Ultimate SNOT‐22 and endoscopic resolution, and time to SNOT‐22 and endoscopic resolution were compared between patients who underwent MA alone versus “complete” ESS (maxillary, ethmoid, frontal; not sphenoid).Results: Of 70 patients, mean age was 59.2 years, and 55.7% were male. Thirty‐five underwent MA alone, and 35 had complete ESS. At first postoperative visits (mean 9.3 days), AE sinus purulence was more likely resolved after complete ESS compared with MA (97.1% vs. 71.4%, p = 0.006). However, time to resolution of AE purulence was comparable by 6 weeks postoperatively (p = 0.158). There were no significant differences in times to foul smell resolution and achieving ≥9 point SNOT‐22 reduction (p > 0.05).Conclusions: For ODS with frontal sinus involvement, MA alone and complete ESS both resulted in rapid and long‐term symptomatic resolution. While ultimate resolution of sinus purulence was equivalent between surgery groups, complete ESS did lead to faster resolution of frontoethmoidal purulence in a significant number of cases.Level of Evidence: 2 Laryngoscope, 135:586–592, 2025
- 27 August 2024
- Published by Wiley in The Laryngoscope
- Vol. 135 (2) , 586-592
Maxillary Antrostomy Versus Complete Sinus Surgery for Odontogenic Sinusitis With Frontal Sinus Extension
Objectives: Endoscopic sinus surgery (ESS) is often necessary when managing odontogenic sinusitis (ODS), but ESS extent for ODS with extramaxillary sinus involvement has been incompletely studied. This study compared outcomes after wide maxillary antrostomy (MA) alone versus complete ESS for ODS with frontal sinus involvement.Methods: A multicenter prospective cohort study was conducted on patients with uncomplicated ODS (no extrasinus spread) who underwent ESS when computed tomography demonstrated maxillary, anterior ethmoid (AE), and frontal sinus opacification. Multiple preoperative and postoperative variables were recorded, including 22‐item sinonasal outcome tests (SNOT‐22) and endoscopic findings. Ultimate SNOT‐22 and endoscopic resolution, and time to SNOT‐22 and endoscopic resolution were compared between patients who underwent MA alone versus “complete” ESS (maxillary, ethmoid, frontal; not sphenoid).Results: Of 70 patients, mean age was 59.2 years, and 55.7% were male. Thirty‐five underwent MA alone, and 35 had complete ESS. At first postoperative visits (mean 9.3 days), AE sinus purulence was more likely resolved after complete ESS compared with MA (97.1% vs. 71.4%, p = 0.006). However, time to resolution of AE purulence was comparable by 6 weeks postoperatively (p = 0.158). There were no significant differences in times to foul smell resolution and achieving ≥9 point SNOT‐22 reduction (p > 0.05).Conclusions: For ODS with frontal sinus involvement, MA alone and complete ESS both resulted in rapid and long‐term symptomatic resolution. While ultimate resolution of sinus purulence was equivalent between surgery groups, complete ESS did lead to faster resolution of frontoethmoidal purulence in a significant number of cases.Level of Evidence: 2 Laryngoscope, 135:586–592, 2025
- 21 October 2023
- Published by Wiley in International Forum of Allergy & Rhinology
- Vol. 14 (6) , 1016-1025
Systematic review of errors on beta‐2 transferrin gel electrophoresis testing of rhinorrhea and otorrhea
Background: Beta‐2 transferrin (B2‐Tf) gel electrophoresis (GE) is the preferred non‐invasive diagnostic modality for confirming cerebrospinal fluid (CSF) in body fluids. While B2‐Tf GE testing is highly sensitive and specific for CSF, false‐positive (FP) and false‐negative (FN) results can lead to diagnostic and therapeutic dilemmas. Several series have demonstrated potential causes of false B2‐Tf GE results, but few studies have reported reasons for these errors. The purpose of this systematic review was to describe sources of B2‐Tf GE errors.Methods: A systematic review was performed by searching OVID, EMBASE, and Web of Science databases for B2‐Tf GE studies. After applying exclusion criteria, original research studies directly addressing erroneous B2‐Tf GE results underwent qualitative analysis.Results: Of the 243 abstracts screened, 71 underwent full‐text review and 18 studies reporting B2‐Tf GE errors were included for analysis. There were 15 potential FPs, 12 actual FPs, 12 potential FNs, 19 actual FNs, and 14 indeterminate results. There were also 246 potentially indeterminate results from in vitro studies. Reasons for B2‐Tf GE errors included serum transferrin alterations (n = 17; all potential), infection related (n = 13; 9 potential), orbital or salivary contamination (n = 2; 1 potential), and collection related (n = 255; 246 potential). There were 31 false or indeterminate results with unspecified reasons. There were no reported errors due to laboratory processing.Conclusions: Multiple potential or actual reasons for false or indeterminate results have been reported for B2‐Tf GE testing of rhinorrhea and otorrhea. Future studies should explore reasons for B2‐Tf testing errors and how these may affect clinical decision making.
- 21 October 2023
- Published by Wiley in International Forum of Allergy & Rhinology
- Vol. 14 (6) , 1016-1025
Systematic review of errors on beta‐2 transferrin gel electrophoresis testing of rhinorrhea and otorrhea
Background: Beta‐2 transferrin (B2‐Tf) gel electrophoresis (GE) is the preferred non‐invasive diagnostic modality for confirming cerebrospinal fluid (CSF) in body fluids. While B2‐Tf GE testing is highly sensitive and specific for CSF, false‐positive (FP) and false‐negative (FN) results can lead to diagnostic and therapeutic dilemmas. Several series have demonstrated potential causes of false B2‐Tf GE results, but few studies have reported reasons for these errors. The purpose of this systematic review was to describe sources of B2‐Tf GE errors.Methods: A systematic review was performed by searching OVID, EMBASE, and Web of Science databases for B2‐Tf GE studies. After applying exclusion criteria, original research studies directly addressing erroneous B2‐Tf GE results underwent qualitative analysis.Results: Of the 243 abstracts screened, 71 underwent full‐text review and 18 studies reporting B2‐Tf GE errors were included for analysis. There were 15 potential FPs, 12 actual FPs, 12 potential FNs, 19 actual FNs, and 14 indeterminate results. There were also 246 potentially indeterminate results from in vitro studies. Reasons for B2‐Tf GE errors included serum transferrin alterations (n = 17; all potential), infection related (n = 13; 9 potential), orbital or salivary contamination (n = 2; 1 potential), and collection related (n = 255; 246 potential). There were 31 false or indeterminate results with unspecified reasons. There were no reported errors due to laboratory processing.Conclusions: Multiple potential or actual reasons for false or indeterminate results have been reported for B2‐Tf GE testing of rhinorrhea and otorrhea. Future studies should explore reasons for B2‐Tf testing errors and how these may affect clinical decision making.
- 4 June 2023
- Published by Wiley in International Forum of Allergy & Rhinology
- Vol. 13 (11) , 2109-2112
Cadaveric analysis of autonomic nerve fiber density in posterior nasal, posterolateral nasal, and anterior ethmoid nerves
Key points: Autonomic nerve densities were equivalent in posterior nasal (PNN), posterolateral nasal (PLNN), and anterior ethmoid nerves (AEN). Rhinitis studies should explore the utility of PLNN and/or AEN transection over PNN alone.
- 4 June 2023
- Published by Wiley in International Forum of Allergy & Rhinology
- Vol. 13 (11) , 2109-2112
Cadaveric analysis of autonomic nerve fiber density in posterior nasal, posterolateral nasal, and anterior ethmoid nerves
Key points: Autonomic nerve densities were equivalent in posterior nasal (PNN), posterolateral nasal (PLNN), and anterior ethmoid nerves (AEN). Rhinitis studies should explore the utility of PLNN and/or AEN transection over PNN alone.
- 1 February 2023
- Published by Georg Thieme Verlag KG in Journal of Neurological Surgery Part B: Skull Base
- Vol. 84 (S 01) , S1-S344
Rapidly Injecting 10 MG of Intrathecal Fluorescein Caused No Neurologic Complications
Background: Intrathecal fluorescein (ITF) is often effective in localizing nasal cerebrospinal fluid (CSF) leaks along the skull base under nasal endoscopy. Previous reports of seizures and paralysis have led to administration practices aimed at minimizing the risk of these potentially catastrophic neurologic complications. Since these early reports, surgeons have often reported injecting ITF slowly over a variable number of minutes, and that it should be diluted either in saline or patients' CSF. However, no study has assessed whether ITF administration duration or dilution alters the risks of these neurologic complications. Methods: From September 2015 through August 2022, all patients undergoing ITF injection through lumbar drains for localization of possible or confirmed nasal CSF leaks were included. All patients had ITF administered by mixing 0.1 mL of 10% fluorescein (10 mg) with 3 to 5 mL of CSF, with no additional fluorescein dilution. The solutions were then injected through lumbar drains rapidly over 1 to 2 seconds. Patient demographics, CSF leak etiologies, and histories of seizures or cerebrovascular accidents were recorded. Results: Sixty-one patients were included, mean age was 56.3 ± 15.6 years, and 82% were female. Fifty patients had CSF leaks repaired successfully, and 11 patients had negative explorations. CSF leaks were due to the following etiologies: idiopathic intracranial hypertension (76%), skull base tumors (10%), accidental trauma (8%), and surgical trauma (6%). Four patients had histories of seizure disorders, and five patients had remote histories of prior cerebrovascular accidents. There were no intraoperative or postoperative episodes of seizure, paralysis, or other neurologic complications. Conclusion: Injecting 10 mg of ITF through lumbar drains rapidly and without true dilution resulted in no seizures, paralysis, or other neurologic complications in patients undergoing endoscopic exploration with or without nasal CSF leak repair. Article published online: 01 February 2023 © 2023. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 1 February 2023
- Published by Georg Thieme Verlag KG in Journal of Neurological Surgery Part B: Skull Base
- Vol. 84 (S 01) , S1-S344
Rapidly Injecting 10 MG of Intrathecal Fluorescein Caused No Neurologic Complications
Background: Intrathecal fluorescein (ITF) is often effective in localizing nasal cerebrospinal fluid (CSF) leaks along the skull base under nasal endoscopy. Previous reports of seizures and paralysis have led to administration practices aimed at minimizing the risk of these potentially catastrophic neurologic complications. Since these early reports, surgeons have often reported injecting ITF slowly over a variable number of minutes, and that it should be diluted either in saline or patients' CSF. However, no study has assessed whether ITF administration duration or dilution alters the risks of these neurologic complications. Methods: From September 2015 through August 2022, all patients undergoing ITF injection through lumbar drains for localization of possible or confirmed nasal CSF leaks were included. All patients had ITF administered by mixing 0.1 mL of 10% fluorescein (10 mg) with 3 to 5 mL of CSF, with no additional fluorescein dilution. The solutions were then injected through lumbar drains rapidly over 1 to 2 seconds. Patient demographics, CSF leak etiologies, and histories of seizures or cerebrovascular accidents were recorded. Results: Sixty-one patients were included, mean age was 56.3 ± 15.6 years, and 82% were female. Fifty patients had CSF leaks repaired successfully, and 11 patients had negative explorations. CSF leaks were due to the following etiologies: idiopathic intracranial hypertension (76%), skull base tumors (10%), accidental trauma (8%), and surgical trauma (6%). Four patients had histories of seizure disorders, and five patients had remote histories of prior cerebrovascular accidents. There were no intraoperative or postoperative episodes of seizure, paralysis, or other neurologic complications. Conclusion: Injecting 10 mg of ITF through lumbar drains rapidly and without true dilution resulted in no seizures, paralysis, or other neurologic complications in patients undergoing endoscopic exploration with or without nasal CSF leak repair. Article published online: 01 February 2023 © 2023. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- Open Access
- 1 August 2016
- Published by American Medical Association (AMA) in JAMA Otolaryngology–Head & Neck Surgery
- Vol. 142 (8) , 801-2
A Young Woman With a Supraclavicular Mass.
- 1 August 2016
- Published by American Medical Association (AMA) in JAMA Otolaryngology–Head & Neck Surgery
- Vol. 142 (8) , 801-2
Open AccessA Young Woman With a Supraclavicular Mass.
- 1 January 2016
- Published by Springer Nature
- p. 3801-3827
Neurobiology and Pharmacology of Sleep Disorders in Otolaryngology: Head and Neck Surgery
- 1 January 2016
- Published by Springer Nature
- p. 3801-3827
Neurobiology and Pharmacology of Sleep Disorders in Otolaryngology: Head and Neck Surgery
- 1 January 2016
- Published by Springer Nature
- p. 3791-3800
Pharmacologic Intervention for Acquired Hearing Loss: Assays of Drug-Induced Inner Ear Damage
- 1 January 2016
- Published by Springer Nature
- p. 3791-3800
Pharmacologic Intervention for Acquired Hearing Loss: Assays of Drug-Induced Inner Ear Damage
- 1 January 2016
- Published by Springer Nature
- p. 3829-3841
Experimental Models for Drug Evaluation in Noise-Induced Hearing Loss and Age-Related Hearing Impairment
- 1 January 2016
- Published by Springer Nature
- p. 3829-3841
Experimental Models for Drug Evaluation in Noise-Induced Hearing Loss and Age-Related Hearing Impairment