Gopinath Mudhana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gopinath Mudhana has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Byeong Ha Lee
Department of Electrical Engineering and Computer Science, Gwangju Institute of Science and Technology, Gwangju 61005, Republic of Korea
8 shared publications - Bala Murugan
School of Electronics Engineering, Vellore Institute of Technology, Chennai, India
3 shared publications Seon Young Ryu
Division of Instrument Development, Korea Basic Science Institute, Daejeon, Republic of Korea
3 shared publicationsSivakumar Muthu
Department of Physics, School of Advanced Sciences, Vellore Institute of Technology, Chennai, Tamil Nadu, India
3 shared publicationsDinesan Chinnaiya
Department of Physics School of Advanced Sciences Vellore Institute of Technology Chennai India
2 shared publicationsEunSeo Choi
Department of Information and Communications Gwangju Institute of Science and Technology 1, Oryong-dong, Buk-Gu, Gwangju, 500-712, Korea
2 shared publications
Latest Publications
- Open Access
- 12 February 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (2) , e70383
The geometric accuracy of off‐axis targets in stereotactic body radiotherapy treatments across three linear accelerators
Purpose: This study quantifies isocenter and off‐axis geometric uncertainties using MultiMet Winston–Lutz (WL) tests to optimize gross tumour volume (GTV)‐to‐PTV (planning target volume) margin for single isocenter multiple target (SIMT) stereotactic body radiotherapy (SBRT) across three linear accelerators. Methods and Materials: Geometric inaccuracies were quantified for Trilogy (HD‐MLC, 6 MV SRS), TrueBeam (Millennium MLC), and TrueBeam STx (HD‐MLC, 6‐degrees‐of‐freedom (6DoF) couch) using a Sun Nuclear MultiMet‐WL cube containing six tungsten carbide markers arranged along the superior–inferior axis. The electronic portal imaging device (EPID) images acquired at four cardinal gantry angles with varied collimator/couch rotations were analyzed using MultiMet‐WL software (v2.1) to measure 3D (Δ) displacements for all the LINACs. The required GTV‐to‐PTV margins were calculated using a modified van Herk formula (2.5Σ+1.64σ), incorporating measured 3D displacements for isocenter and off‐axis targets. Results: The TrueBeam STx (HD‐MLC/6DoF) demonstrated superior geometric accuracy, maintaining ≤0.5 mm isocenter precision and ≤0.59 mm off‐axis targeting (3–7 cm). The Trilogy exceeded TG‐142 tolerances (1.06 ± 0.59 to 1.09 ± 0.57 mm) at all targets, requiring 4 mm uniform margins, while the TrueBeam (MMLC) showed optimal variations (isocenter: 0.68 ± 0.34 mm; superior off‐axis: 0.74 ± 0.36 mm). Both TrueBeam platforms achieved sub‐millimeter accuracy but demonstrated direction dependency for off‐axis targets, requiring 2–3 mm anisotropic margins. Notably, isotropic margins introduced up to 11% delineation errors for off‐axis targets due to these machine‐specific geometric variations, highlighting the imperative for platform‐specific margin protocols in SIMT SBRT. Conclusion: This study demonstrates that routine analysis of MultiMet WL testing is an essential tool for the spatial accuracy of the LINAC to establish machine‐specific PTV margin expansion in SIMT‐SBRT, particularly for targets where rotational errors dominate.
- 12 February 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (2) , e70383
Open AccessThe geometric accuracy of off‐axis targets in stereotactic body radiotherapy treatments across three linear accelerators
Purpose: This study quantifies isocenter and off‐axis geometric uncertainties using MultiMet Winston–Lutz (WL) tests to optimize gross tumour volume (GTV)‐to‐PTV (planning target volume) margin for single isocenter multiple target (SIMT) stereotactic body radiotherapy (SBRT) across three linear accelerators. Methods and Materials: Geometric inaccuracies were quantified for Trilogy (HD‐MLC, 6 MV SRS), TrueBeam (Millennium MLC), and TrueBeam STx (HD‐MLC, 6‐degrees‐of‐freedom (6DoF) couch) using a Sun Nuclear MultiMet‐WL cube containing six tungsten carbide markers arranged along the superior–inferior axis. The electronic portal imaging device (EPID) images acquired at four cardinal gantry angles with varied collimator/couch rotations were analyzed using MultiMet‐WL software (v2.1) to measure 3D (Δ) displacements for all the LINACs. The required GTV‐to‐PTV margins were calculated using a modified van Herk formula (2.5Σ+1.64σ), incorporating measured 3D displacements for isocenter and off‐axis targets. Results: The TrueBeam STx (HD‐MLC/6DoF) demonstrated superior geometric accuracy, maintaining ≤0.5 mm isocenter precision and ≤0.59 mm off‐axis targeting (3–7 cm). The Trilogy exceeded TG‐142 tolerances (1.06 ± 0.59 to 1.09 ± 0.57 mm) at all targets, requiring 4 mm uniform margins, while the TrueBeam (MMLC) showed optimal variations (isocenter: 0.68 ± 0.34 mm; superior off‐axis: 0.74 ± 0.36 mm). Both TrueBeam platforms achieved sub‐millimeter accuracy but demonstrated direction dependency for off‐axis targets, requiring 2–3 mm anisotropic margins. Notably, isotropic margins introduced up to 11% delineation errors for off‐axis targets due to these machine‐specific geometric variations, highlighting the imperative for platform‐specific margin protocols in SIMT SBRT. Conclusion: This study demonstrates that routine analysis of MultiMet WL testing is an essential tool for the spatial accuracy of the LINAC to establish machine‐specific PTV margin expansion in SIMT‐SBRT, particularly for targets where rotational errors dominate.
- Open Access
- 1 April 2025
- Published by Wolters Kluwer Health in Journal of Medical Physics
- Vol. 50 (2) , 297-305
Normal Tissue Objective Parameter Optimization in Eclipse Treatment Planning System: Enhancing Stereotactic Radiosurgery Quality with Noncoplanar RapidArc versus HyperArc Plans
Purpose: The purpose of this study was to identify the most effective manual normal tissue objective (mNTO) parameters for noncoplanar RapidArc (RA) stereotactic radiosurgery (SRS) plans and assess their performance against HyperArc (HA) plans. Materials and Methods: This retrospective study included 28 patients with single brain metastasis prescribed 21 Gy. Noncoplanar RA (RA-mNTO) plans were generated using dose fall-offs of 0.1–5.0 mm−1 and end doses of 50%, 25%, and 10%. In addition, two HA plans were created for comparison: one with SRS NTO (HA-sNTO) and the other with mNTO (HA-mNTO). Plans were evaluated using an integrated scoring approach that include Paddick Conformity Index (CI), gradient index (GI), homogeneity index (HI), monitor units (MUs), normal brain doses (V18 Gy, V15 Gy, and V12 Gy), and delivery accuracy with aS1200 portal dosimetry applying 3%/1 mm gamma criteria. Statistical analysis was carried out using Wilcoxon signed-rank test. Results: RA-mNTO plan with a 25% end-dose and a 0.5 mm−1 dose fall-off significantly outperformed HA plans (P < 0.05) in CI, GI, and HI values (0.92 ± 0.02, 3.0 ± 0.17, and 0.32 ± 0.05 vs. 0.91 ± 0.04, 3.41 ± 0.19, and 0.40 ± 0.04 for HA-sNTO and 0.90 ± 0.04, 3.17 ± 0.24, and 0.40 ± 0.05 for HA-mNTO). Furthermore, RA-mNTO significantly (P < 0.05) reduced brain doses at V18Gy (0.88 cc ± 0.40), V15Gy (1.80 cc ± 0.77), and V12Gy (3.19 cc ± 1.35) compared to HA-sNTO (1.13 cc ± 0.51, 2.30 cc ± 1.01, 3.96 cc ± 1.72) and HA-mNTO (1.02 cc ± 0.44, 2.06 cc ± 0.86, 3.53 cc ± 1.47). Moreover, RA-mNTO showed significantly (P < 0.05) lower MUs (8238 ± 948) compared to HA-sNTO (9505 ± 1098) and HA-mNTO (9315 ± 421) and higher gamma pass rates (99.8% ± 0.39) than HA-sNTO (98.9% ± 0.68) and HA-mNTO (99.0% ± 0.51). Conclusion: Optimized mNTO (25% end-dose and a 0.5 mm−1 dose fall-off)-based noncoplanar RA plans outperformed HA in SRS treatment of single brain metastasis.
- 1 April 2025
- Published by Wolters Kluwer Health in Journal of Medical Physics
- Vol. 50 (2) , 297-305
Open AccessNormal Tissue Objective Parameter Optimization in Eclipse Treatment Planning System: Enhancing Stereotactic Radiosurgery Quality with Noncoplanar RapidArc versus HyperArc Plans
Purpose: The purpose of this study was to identify the most effective manual normal tissue objective (mNTO) parameters for noncoplanar RapidArc (RA) stereotactic radiosurgery (SRS) plans and assess their performance against HyperArc (HA) plans. Materials and Methods: This retrospective study included 28 patients with single brain metastasis prescribed 21 Gy. Noncoplanar RA (RA-mNTO) plans were generated using dose fall-offs of 0.1–5.0 mm−1 and end doses of 50%, 25%, and 10%. In addition, two HA plans were created for comparison: one with SRS NTO (HA-sNTO) and the other with mNTO (HA-mNTO). Plans were evaluated using an integrated scoring approach that include Paddick Conformity Index (CI), gradient index (GI), homogeneity index (HI), monitor units (MUs), normal brain doses (V18 Gy, V15 Gy, and V12 Gy), and delivery accuracy with aS1200 portal dosimetry applying 3%/1 mm gamma criteria. Statistical analysis was carried out using Wilcoxon signed-rank test. Results: RA-mNTO plan with a 25% end-dose and a 0.5 mm−1 dose fall-off significantly outperformed HA plans (P < 0.05) in CI, GI, and HI values (0.92 ± 0.02, 3.0 ± 0.17, and 0.32 ± 0.05 vs. 0.91 ± 0.04, 3.41 ± 0.19, and 0.40 ± 0.04 for HA-sNTO and 0.90 ± 0.04, 3.17 ± 0.24, and 0.40 ± 0.05 for HA-mNTO). Furthermore, RA-mNTO significantly (P < 0.05) reduced brain doses at V18Gy (0.88 cc ± 0.40), V15Gy (1.80 cc ± 0.77), and V12Gy (3.19 cc ± 1.35) compared to HA-sNTO (1.13 cc ± 0.51, 2.30 cc ± 1.01, 3.96 cc ± 1.72) and HA-mNTO (1.02 cc ± 0.44, 2.06 cc ± 0.86, 3.53 cc ± 1.47). Moreover, RA-mNTO showed significantly (P < 0.05) lower MUs (8238 ± 948) compared to HA-sNTO (9505 ± 1098) and HA-mNTO (9315 ± 421) and higher gamma pass rates (99.8% ± 0.39) than HA-sNTO (98.9% ± 0.68) and HA-mNTO (99.0% ± 0.51). Conclusion: Optimized mNTO (25% end-dose and a 0.5 mm−1 dose fall-off)-based noncoplanar RA plans outperformed HA in SRS treatment of single brain metastasis.
- Open Access
- 28 November 2024
- Published by Association for Computing Machinery (ACM)
- p. 184-188
Measurement of Hourly Tear Volume Variation using Smartphone Meniscometer: A 24-Hour Pilot Study
- 28 November 2024
- Published by Association for Computing Machinery (ACM)
- p. 184-188
Open AccessMeasurement of Hourly Tear Volume Variation using Smartphone Meniscometer: A 24-Hour Pilot Study
- Open Access
- 28 November 2024
- Published by Association for Computing Machinery (ACM)
- p. 180-183
Development of Advanced Pulse Measuring Diagnostic Device Working on Traditional Ayurvedic Principles
- 28 November 2024
- Published by Association for Computing Machinery (ACM)
- p. 180-183
Open AccessDevelopment of Advanced Pulse Measuring Diagnostic Device Working on Traditional Ayurvedic Principles
- 6 November 2024
- Published by Springer Nature in Japanese Journal of Radiology
- p. 1-10
Optimizing normal tissue objectives (NTO) in eclipse treatment planning system (TPS) for stereotactic treatment of multiple brain metastases using non-coplanar RapidArc and comparison with HyperArc techniques
Purpose To optimize NTO parameters in non-coplanar RapidArc (RA) stereotactic radiosurgery (SRS) for multiple brain metastases and compare them with HyperArc (HA) plans. Materials and methods Thirty patients with multiple brain metastases, receiving 21 Gy prescriptions, were retrospectively enrolled, with lesions ranging from two to eight and volumes between 0.27 and 10.56 cm3. Non-coplanar RapidArc plans utilized manual NTO (RA-mNTO) with varying dose fall-off values (0.1 mm−1, 0.5 mm−1, 1.0 mm−1, 2.0 mm−1, 3.0 mm−1) and end doses (50%, 25% & 10%). Additionally, two HyperArc plans were generated: HA-ALDO used Automatic Lower Dose Objectives with SRS NTO, while HA-mNTO used the same beam geometry with manual NTO parameters optimized from RA-mNTO plans. TrueBeam with High-Definition Multi-leaf Collimators (HDMLC), 6 MV Flattening Filter Free (FFF) Beam at a maximum dose rate of 1400 MU/min, and Eclipse version 16.1 TPS were used. Plans were assessed for Paddick Conformity Index (CI), Gradient Index (GI), Homogeneity Index (HI), normal brain doses (V18Gy, V15Gy, and V12Gy), Monitor Units (MUs), and delivery accuracy using aS1200 Digital Megavolt Imager (DMI) with 2%/2 mm gamma criteria. Statistical analysis utilized integrated scoring and the Wilcoxon signed-rank test. Results RA-mNTO plans with 0.5 mm⁻1 dose fall-off and 10% end-dose showed superior dosimetric outcomes: CI (0.85 ± 0.08), GI (3.63 ± 0.87), and HI (0.36 ± 0.06) compared to HA-ALDO (CI 0.84 ± 0.09, GI: 3.97 ± 0.85, HI: 0.39 ± 0.07) and HA-mNTO (CI 0.83 ± 0.08, GI: 3.60 ± 0.93, HI: 0.40 ± 0.06). MUs were comparable: RA-mNTO (9679 ± 1882), HA-ALDO (9509 ± 1315), and higher for HA-mNTO (10,457 ± 1980). RA-mNTO plans exhibited significantly lower normal brain doses (V18Gy: 1.78 ± 1.23, V15Gy: 3.54 ± 2.37, V12Gy: 6.21 ± 4.09) compared to HA-ALDO (V18Gy: 2.02 ± 1.34, V15Gy: 4.09 ± 2.66, V12Gy: 7.15 ± 4.56) and HA-mNTO (V18Gy: 1.85 ± 1.20, V15Gy: 3.68 ± 2.33, V12Gy: 6.36 ± 3.97). All techniques achieved > 98% gamma pass rate. Conclusion Non-coplanar RA plans with optimized mNTO settings outperformed HyperArc plans in all studied dosimetric parameters for SRS treatment of multiple brain metastases.
- 6 November 2024
- Published by Springer Nature in Japanese Journal of Radiology
- p. 1-10
Optimizing normal tissue objectives (NTO) in eclipse treatment planning system (TPS) for stereotactic treatment of multiple brain metastases using non-coplanar RapidArc and comparison with HyperArc techniques
Purpose To optimize NTO parameters in non-coplanar RapidArc (RA) stereotactic radiosurgery (SRS) for multiple brain metastases and compare them with HyperArc (HA) plans. Materials and methods Thirty patients with multiple brain metastases, receiving 21 Gy prescriptions, were retrospectively enrolled, with lesions ranging from two to eight and volumes between 0.27 and 10.56 cm3. Non-coplanar RapidArc plans utilized manual NTO (RA-mNTO) with varying dose fall-off values (0.1 mm−1, 0.5 mm−1, 1.0 mm−1, 2.0 mm−1, 3.0 mm−1) and end doses (50%, 25% & 10%). Additionally, two HyperArc plans were generated: HA-ALDO used Automatic Lower Dose Objectives with SRS NTO, while HA-mNTO used the same beam geometry with manual NTO parameters optimized from RA-mNTO plans. TrueBeam with High-Definition Multi-leaf Collimators (HDMLC), 6 MV Flattening Filter Free (FFF) Beam at a maximum dose rate of 1400 MU/min, and Eclipse version 16.1 TPS were used. Plans were assessed for Paddick Conformity Index (CI), Gradient Index (GI), Homogeneity Index (HI), normal brain doses (V18Gy, V15Gy, and V12Gy), Monitor Units (MUs), and delivery accuracy using aS1200 Digital Megavolt Imager (DMI) with 2%/2 mm gamma criteria. Statistical analysis utilized integrated scoring and the Wilcoxon signed-rank test. Results RA-mNTO plans with 0.5 mm⁻1 dose fall-off and 10% end-dose showed superior dosimetric outcomes: CI (0.85 ± 0.08), GI (3.63 ± 0.87), and HI (0.36 ± 0.06) compared to HA-ALDO (CI 0.84 ± 0.09, GI: 3.97 ± 0.85, HI: 0.39 ± 0.07) and HA-mNTO (CI 0.83 ± 0.08, GI: 3.60 ± 0.93, HI: 0.40 ± 0.06). MUs were comparable: RA-mNTO (9679 ± 1882), HA-ALDO (9509 ± 1315), and higher for HA-mNTO (10,457 ± 1980). RA-mNTO plans exhibited significantly lower normal brain doses (V18Gy: 1.78 ± 1.23, V15Gy: 3.54 ± 2.37, V12Gy: 6.21 ± 4.09) compared to HA-ALDO (V18Gy: 2.02 ± 1.34, V15Gy: 4.09 ± 2.66, V12Gy: 7.15 ± 4.56) and HA-mNTO (V18Gy: 1.85 ± 1.20, V15Gy: 3.68 ± 2.33, V12Gy: 6.36 ± 3.97). All techniques achieved > 98% gamma pass rate. Conclusion Non-coplanar RA plans with optimized mNTO settings outperformed HyperArc plans in all studied dosimetric parameters for SRS treatment of multiple brain metastases.
- 11 May 2024
- Published by Springer Nature in Indian Journal of Physics
- Vol. 98 (13) , 4399-4420
Half-metallic and thermodynamic properties of Fe-based quaternary Heusler alloys: an ab initio study
- 11 May 2024
- Published by Springer Nature in Indian Journal of Physics
- Vol. 98 (13) , 4399-4420
Half-metallic and thermodynamic properties of Fe-based quaternary Heusler alloys: an ab initio study
- 29 April 2024
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 63 (2) , 203-214
Assessment of stereotactic high-resolution detectors for stereotactic body radiotherapy: comparative analysis between myQA® SRS and Gafchromic EBT-XD films
The study aimed to evaluate dosimetry systems used for stereotactic body radiotherapy (SBRT), specifically 2D array dosimetry and film dosimetry systems, for exploring their characteristics and clinical suitability. For this, high-resolution myQA SRS detectors and Gafchromic EBT-XD films were employed. Film analysis included net optical density (OD) values depending on energy, dose rate, scanner orientation, scanning side, and post-exposure growth. For myQA SRS, signal values were evaluated in terms of dose rate (400–1400 MU/min) and angular dependence (0–180° at 30° intervals) along with couch angles of 0°, 45°, and 90°. Pre-treatment verification included 32 SBRT patients for whom myQA SRS results were compared with those obtained with Gafchromic EBT-XD films. Analysis revealed less than 1% deviation in net OD for energy and dose rate dependence. Scanner orientation caused 2.5% net OD variation, with minimal differences between film front and back scan orientations (variance < 1.0%). A rapid OD rise occurred within six hours post-exposure, followed by gradual increase. The myQA SRS detector showed − 3.7% dose rate dependence (400 MU/min), while the angular dependence at 90° was − 26.7%. A correction factor effectively reduced these differences to < 1%. For myQA SRS, gamma passing rates were—93.6% (2%/1 mm), while those for EBT-XD films were—92.8%. Improved rates were observed with 3%/1 mm: for myQA SRS—97.9%, and for EBT-XD film—98.16%. In contrast, for 2%/2 mm with 10% threshold, for myQA SRS—97.7% and for EBT-XD film—98.97% were obtained. It is concluded that both myQA SRS detectors and EBT-XD films are suitable for SBRT pre-treatment verification, ensuring accuracy and reliability. However, myQA SRS detectors are preferred over EBT-XD film due to the fact that they offer real-time measurements and user-friendly features. Graphical Abstract
- 29 April 2024
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 63 (2) , 203-214
Assessment of stereotactic high-resolution detectors for stereotactic body radiotherapy: comparative analysis between myQA® SRS and Gafchromic EBT-XD films
The study aimed to evaluate dosimetry systems used for stereotactic body radiotherapy (SBRT), specifically 2D array dosimetry and film dosimetry systems, for exploring their characteristics and clinical suitability. For this, high-resolution myQA SRS detectors and Gafchromic EBT-XD films were employed. Film analysis included net optical density (OD) values depending on energy, dose rate, scanner orientation, scanning side, and post-exposure growth. For myQA SRS, signal values were evaluated in terms of dose rate (400–1400 MU/min) and angular dependence (0–180° at 30° intervals) along with couch angles of 0°, 45°, and 90°. Pre-treatment verification included 32 SBRT patients for whom myQA SRS results were compared with those obtained with Gafchromic EBT-XD films. Analysis revealed less than 1% deviation in net OD for energy and dose rate dependence. Scanner orientation caused 2.5% net OD variation, with minimal differences between film front and back scan orientations (variance < 1.0%). A rapid OD rise occurred within six hours post-exposure, followed by gradual increase. The myQA SRS detector showed − 3.7% dose rate dependence (400 MU/min), while the angular dependence at 90° was − 26.7%. A correction factor effectively reduced these differences to < 1%. For myQA SRS, gamma passing rates were—93.6% (2%/1 mm), while those for EBT-XD films were—92.8%. Improved rates were observed with 3%/1 mm: for myQA SRS—97.9%, and for EBT-XD film—98.16%. In contrast, for 2%/2 mm with 10% threshold, for myQA SRS—97.7% and for EBT-XD film—98.97% were obtained. It is concluded that both myQA SRS detectors and EBT-XD films are suitable for SBRT pre-treatment verification, ensuring accuracy and reliability. However, myQA SRS detectors are preferred over EBT-XD film due to the fact that they offer real-time measurements and user-friendly features. Graphical Abstract
- Open Access
- 1 April 2024
- Published by EpiSmart Science Vector Ltd in Asian Pacific Journal of Cancer Prevention
- Vol. 25 (4) , 1425-1432
Dosimetric Systems in Pre-Treatment QA for Stereotactic Treatments: Correlation Agreements and Target Volume Dependency
Aim: This study comprehensively investigated pre-treatment quality assurance (QA) for 100 cancer patients undergoing stereotactic treatments (SRS/SRT) using various detectors. Methods: The study conducted QA for SRS/SRT treatments planned with a 6MV SRS beam at a dose rate of 1,000 MU/min, utilizing Eclipse v13.6 Treatment Planning System (TPS). Point dose measurements employed 0.01cm3 and 0.13cm3 cylindrical ionization chambers, while planar dose verification utilized Gafchromic EBT-XD Film and Portal Imager (aS1000). Plans were categorized by target volume, and a thorough analysis compared point dose agreements, planar dose gamma pass rates, and their correlations with chamber volume mean dose, detector type, and point dose agreement. Additionally, the consistency between different ionization chambers was assessed. Results: Point dose agreement generally improved with increasing target volume, except for volumes over 10cm3 with 0.01cm3 chambers, showing a contrary trend. Significant differences (p10cm3 group in EBT XD. EBT XD demonstrated better agreement with TPS for target volumes up to 10cm3 compared to aS1000, with a statistically significant difference (p<0.05) between the detectors. Strong correlations were found between chamber point dose and chamber volume mean dose agreement, as well as between the two gamma criteria analyses of the same detector type in the planar dose correlation analysis. However, weak correlations were discovered for other analyses. Conclusion: This study found weak correlation between different detector types in pre-treatment QA for point dose and planar dose evaluation. However, within a specific detector type, strong correlation was observed for different point dose evaluation methods and gamma criteria. This highlights the importance of cautious interpretation of QA results, particularly for SRS QA, due to the lack of correlation between detector types.
- 1 April 2024
- Published by EpiSmart Science Vector Ltd in Asian Pacific Journal of Cancer Prevention
- Vol. 25 (4) , 1425-1432
Open AccessDosimetric Systems in Pre-Treatment QA for Stereotactic Treatments: Correlation Agreements and Target Volume Dependency
Aim: This study comprehensively investigated pre-treatment quality assurance (QA) for 100 cancer patients undergoing stereotactic treatments (SRS/SRT) using various detectors. Methods: The study conducted QA for SRS/SRT treatments planned with a 6MV SRS beam at a dose rate of 1,000 MU/min, utilizing Eclipse v13.6 Treatment Planning System (TPS). Point dose measurements employed 0.01cm3 and 0.13cm3 cylindrical ionization chambers, while planar dose verification utilized Gafchromic EBT-XD Film and Portal Imager (aS1000). Plans were categorized by target volume, and a thorough analysis compared point dose agreements, planar dose gamma pass rates, and their correlations with chamber volume mean dose, detector type, and point dose agreement. Additionally, the consistency between different ionization chambers was assessed. Results: Point dose agreement generally improved with increasing target volume, except for volumes over 10cm3 with 0.01cm3 chambers, showing a contrary trend. Significant differences (p10cm3 group in EBT XD. EBT XD demonstrated better agreement with TPS for target volumes up to 10cm3 compared to aS1000, with a statistically significant difference (p<0.05) between the detectors. Strong correlations were found between chamber point dose and chamber volume mean dose agreement, as well as between the two gamma criteria analyses of the same detector type in the planar dose correlation analysis. However, weak correlations were discovered for other analyses. Conclusion: This study found weak correlation between different detector types in pre-treatment QA for point dose and planar dose evaluation. However, within a specific detector type, strong correlation was observed for different point dose evaluation methods and gamma criteria. This highlights the importance of cautious interpretation of QA results, particularly for SRS QA, due to the lack of correlation between detector types.
- Open Access
- 14 December 2023
- Published by Association for Computing Machinery (ACM)
- p. 194-199
Integrative Deep Learning Forecasting of Air Quality Index in India: A Fusion of Bidirectional LSTM and Sensor Data
AQI as a vital metric for evaluating pollution levels, which directly impacts the health and well-being of the population. We have devised a hybrid deep learning (DL) framework that combines the Bi-directional LSTM with a sensor fusion approach. Our integrated model combines the strengths of sensor fusion and Bi-LSTM, enhancing both spatial and temporal dependencies in the data. Additional training of the data from independent sensors prior to the AQI calculation and training of the proposed method provided much better AQI prediction capability due to the added information on the spatial variation of the data. Empirical validation with real-world data from the Chennai city in India, demonstrates superior accuracy, achieving a Root Mean Square Error (RMSE) of 21.7 for AQI prediction.
- 14 December 2023
- Published by Association for Computing Machinery (ACM)
- p. 194-199
Open AccessIntegrative Deep Learning Forecasting of Air Quality Index in India: A Fusion of Bidirectional LSTM and Sensor Data
AQI as a vital metric for evaluating pollution levels, which directly impacts the health and well-being of the population. We have devised a hybrid deep learning (DL) framework that combines the Bi-directional LSTM with a sensor fusion approach. Our integrated model combines the strengths of sensor fusion and Bi-LSTM, enhancing both spatial and temporal dependencies in the data. Additional training of the data from independent sensors prior to the AQI calculation and training of the proposed method provided much better AQI prediction capability due to the added information on the spatial variation of the data. Empirical validation with real-world data from the Chennai city in India, demonstrates superior accuracy, achieving a Root Mean Square Error (RMSE) of 21.7 for AQI prediction.