Pierrick Clément
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Pierrick Clément has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
- Eduard Llobet
Universitat Rovira i Virgili
9 shared publications - Adnane Abdelghani
Unité de Recherche de Physique des Semiconducteurs et Capteurs, IPEST, 2070 La Marsa, Tunisia
5 shared publications - Matteo Palma
Department of Chemistry Queen Mary University of London London UK
4 shared publications Eduard Llobet
niversitat Roviri I Virgili, 43007 Tarragona, Spain
3 shared publicationsHamdi Baccar
Carthage University, National Institute of Applied Science and Technology, Nanotechnology Group, Bp676, Centre Urbain Nord, 1080 Charguia Cedex, Tunisia
3 shared publicationsAntonio Attanzio
School of Biological and Chemical Sciences, Materials Research Institute, Queen Mary University of London, London, E1 4NS, UK
2 shared publications
Latest Publications
- 31 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Functionalized carbon nanotubes for detecting traces of benzene vapors employing screen-printed resistive and resonant transducers
Nanotubes de carbone fonctionnalisés pour la détection de traces de vapeurs de benzène à l’aide de transducteurs résistifs et résonants sérigraphiés: Ce travail de thèse porte sur l’optimisation des propriétés de nanotubes de carbone pour la détection de gaz.Pour cette application, les nanotubes de carbone ont été déposés sur deux types de transducteur sérigraphiés, résistif et résonant. Les nanotubes de carbone à multi-parois traités par plasma d’oxygène (O-MWCNTs) ont été le point de départ de ces travaux. Les performances de ces nanomatériaux déposés par air-brushing sur le transducteur de type résistif comportant deux électrodes de platine interdigitées préalablement déposées sur un substrat d’alumine ont été étudiées en présence de composés organiques volatils (COVs). Par comparaison aux réponses obtenues sous éthanol et acétone,une meilleure sensibilité et un meilleur temps de recouvrement ont été observés en présence de benzène et de toluène. Les nanotubes de carbone O-MWCNTs ont été ensuite déposés sur une micropoutre piézoélectrique sérigraphiée. Cette dernière, à base de PZT placé entre 2 électrodes, permet simultanément l’actionnement et la mesure de sa fréquence de résonance. De plus, le remplacement de l’électrode supérieure de géométrie rectangulaire par deux électrodes interdigitées a permis la mesure simultanée de la résistance des nanotubes de carbone et de la fréquence de résonance. Grâce à cette nouvelle génération de transducteur, la variation de résistance de la couche de nanotubes de carbone et la variation de masse ont pu être mesurés en présence de COVs mais aussi de monoxyde de carbone et de dioxyde d’azote. Sous forte concentration de vapeurs/gaz, la prise de masse de la couche sensible entraîne des variations de fréquence négatives. En revanche, à plus faible concentration, des variations de fréquence positives ont été observées. Ce phénomène est attribué à une modification de la rigidité de la poutre résonante suite à l’adsorption sur la poutre de l’espèce à détecter enfaible quantité. La mesure simultanée de la résistance des OMWCNTs de type-p a de plus permis la discrimination du caractère oxydant ou réducteur des gaz/vapeurs. Finalement,face à la difficulté de détecter le benzène à faible concentration, une approche basée sur la reconnaissance moléculaire « host-guest » a été proposée. Afin de promouvoir des interactions spécifiques avec le benzène, les MWCNTs ont été fonctionnalisés avec une molécule de type quinoxaléine en conformation de cavité. Ainsi, la mesure de la résistance de ce nanomatériau hybride a permis la détection de 2,5 ppb de benzène sous air sec avec une limite de détection (LOD) proche de 600 ppt. Ces résultats remarquables démontrent les potentialités des nanotubes de carbone fonctionnalisés pour la détection de faibles traces de composés aromatiques.
- 31 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Functionalized carbon nanotubes for detecting traces of benzene vapors employing screen-printed resistive and resonant transducers
Nanotubes de carbone fonctionnalisés pour la détection de traces de vapeurs de benzène à l’aide de transducteurs résistifs et résonants sérigraphiés: Ce travail de thèse porte sur l’optimisation des propriétés de nanotubes de carbone pour la détection de gaz.Pour cette application, les nanotubes de carbone ont été déposés sur deux types de transducteur sérigraphiés, résistif et résonant. Les nanotubes de carbone à multi-parois traités par plasma d’oxygène (O-MWCNTs) ont été le point de départ de ces travaux. Les performances de ces nanomatériaux déposés par air-brushing sur le transducteur de type résistif comportant deux électrodes de platine interdigitées préalablement déposées sur un substrat d’alumine ont été étudiées en présence de composés organiques volatils (COVs). Par comparaison aux réponses obtenues sous éthanol et acétone,une meilleure sensibilité et un meilleur temps de recouvrement ont été observés en présence de benzène et de toluène. Les nanotubes de carbone O-MWCNTs ont été ensuite déposés sur une micropoutre piézoélectrique sérigraphiée. Cette dernière, à base de PZT placé entre 2 électrodes, permet simultanément l’actionnement et la mesure de sa fréquence de résonance. De plus, le remplacement de l’électrode supérieure de géométrie rectangulaire par deux électrodes interdigitées a permis la mesure simultanée de la résistance des nanotubes de carbone et de la fréquence de résonance. Grâce à cette nouvelle génération de transducteur, la variation de résistance de la couche de nanotubes de carbone et la variation de masse ont pu être mesurés en présence de COVs mais aussi de monoxyde de carbone et de dioxyde d’azote. Sous forte concentration de vapeurs/gaz, la prise de masse de la couche sensible entraîne des variations de fréquence négatives. En revanche, à plus faible concentration, des variations de fréquence positives ont été observées. Ce phénomène est attribué à une modification de la rigidité de la poutre résonante suite à l’adsorption sur la poutre de l’espèce à détecter enfaible quantité. La mesure simultanée de la résistance des OMWCNTs de type-p a de plus permis la discrimination du caractère oxydant ou réducteur des gaz/vapeurs. Finalement,face à la difficulté de détecter le benzène à faible concentration, une approche basée sur la reconnaissance moléculaire « host-guest » a été proposée. Afin de promouvoir des interactions spécifiques avec le benzène, les MWCNTs ont été fonctionnalisés avec une molécule de type quinoxaléine en conformation de cavité. Ainsi, la mesure de la résistance de ce nanomatériau hybride a permis la détection de 2,5 ppb de benzène sous air sec avec une limite de détection (LOD) proche de 600 ppt. Ces résultats remarquables démontrent les potentialités des nanotubes de carbone fonctionnalisés pour la détection de faibles traces de composés aromatiques.
- Open Access
- 27 February 2024
- Published by Springer Nature in Journal of Cannabis Research
- Vol. 6 (1) , 1-17
Recent advances in the development of portable technologies and commercial products to detect Δ9-tetrahydrocannabinol in biofluids: a systematic review
Background: The primary components driving the current commercial fascination with cannabis products are phytocannabinoids, a diverse group of over 100 lipophilic secondary metabolites derived from the cannabis plant. Although numerous phytocannabinoids exhibit pharmacological effects, the foremost attention has been directed towards Δ9-tetrahydrocannabinol (THC) and cannabidiol, the two most abundant phytocannabinoids, for their potential human applications. Despite their structural similarity, THC and cannabidiol diverge in terms of their psychotropic effects, with THC inducing notable psychological alterations. There is a clear need for accurate and rapid THC measurement methods that offer dependable, readily accessible, and cost-effective analytical information. This review presents a comprehensive view of the present state of alternative technologies that could potentially facilitate the creation of portable devices suitable for on-site usage or as personal monitors, enabling non-intrusive THC measurements. Method: A literature survey from 2017 to 2023 on the development of portable technologies and commercial products to detect THC in biofluids was performed using electronic databases such as PubMed, Scopus, and Google Scholar. A systematic review of available literature was conducted using Preferred Reporting Items for Systematic. Reviews and Meta-analysis (PRISMA) guidelines. Results: Eighty-nine studies met the selection criteria. Fifty-seven peer-reviewed studies were related to the detection of THC by conventional separation techniques used in analytical laboratories that are still considered the gold standard. Studies using optical (n = 12) and electrochemical (n = 13) portable sensors and biosensors were also identified as well as commercially available devices (n = 7). Discussion: The landscape of THC detection technology is predominantly shaped by immunoassay tests, owing to their established reliability. However, these methods have distinct drawbacks, particularly for quantitative analysis. Electrochemical sensing technology holds great potential to overcome the challenges of quantification and present a multitude of advantages, encompassing the possibility of miniaturization and diverse modifications to amplify sensitivity and selectivity. Nevertheless, these sensors have considerable limitations, including non-specific interactions and the potential interference of compounds and substances existing in biofluids. Conclusion: The foremost challenge in THC detection involves creating electrochemical sensors that are both stable and long-lasting while exhibiting exceptional selectivity, minimal non-specific interactions, and decreased susceptibility to matrix interferences. These aspects need to be resolved before these sensors can be successfully introduced to the market.
- 27 February 2024
- Published by Springer Nature in Journal of Cannabis Research
- Vol. 6 (1) , 1-17
Open AccessRecent advances in the development of portable technologies and commercial products to detect Δ9-tetrahydrocannabinol in biofluids: a systematic review
Background: The primary components driving the current commercial fascination with cannabis products are phytocannabinoids, a diverse group of over 100 lipophilic secondary metabolites derived from the cannabis plant. Although numerous phytocannabinoids exhibit pharmacological effects, the foremost attention has been directed towards Δ9-tetrahydrocannabinol (THC) and cannabidiol, the two most abundant phytocannabinoids, for their potential human applications. Despite their structural similarity, THC and cannabidiol diverge in terms of their psychotropic effects, with THC inducing notable psychological alterations. There is a clear need for accurate and rapid THC measurement methods that offer dependable, readily accessible, and cost-effective analytical information. This review presents a comprehensive view of the present state of alternative technologies that could potentially facilitate the creation of portable devices suitable for on-site usage or as personal monitors, enabling non-intrusive THC measurements. Method: A literature survey from 2017 to 2023 on the development of portable technologies and commercial products to detect THC in biofluids was performed using electronic databases such as PubMed, Scopus, and Google Scholar. A systematic review of available literature was conducted using Preferred Reporting Items for Systematic. Reviews and Meta-analysis (PRISMA) guidelines. Results: Eighty-nine studies met the selection criteria. Fifty-seven peer-reviewed studies were related to the detection of THC by conventional separation techniques used in analytical laboratories that are still considered the gold standard. Studies using optical (n = 12) and electrochemical (n = 13) portable sensors and biosensors were also identified as well as commercially available devices (n = 7). Discussion: The landscape of THC detection technology is predominantly shaped by immunoassay tests, owing to their established reliability. However, these methods have distinct drawbacks, particularly for quantitative analysis. Electrochemical sensing technology holds great potential to overcome the challenges of quantification and present a multitude of advantages, encompassing the possibility of miniaturization and diverse modifications to amplify sensitivity and selectivity. Nevertheless, these sensors have considerable limitations, including non-specific interactions and the potential interference of compounds and substances existing in biofluids. Conclusion: The foremost challenge in THC detection involves creating electrochemical sensors that are both stable and long-lasting while exhibiting exceptional selectivity, minimal non-specific interactions, and decreased susceptibility to matrix interferences. These aspects need to be resolved before these sensors can be successfully introduced to the market.
- Open Access
- 1 January 2024
- Published by AMA Service GmbH
- p. 177-178
OT6.195 - Aptamer-based Electrochemical Sensor for the Monitoring of Carbamazepine in Freshwater Systems
Carbamazepine (CBZ) is an active compound in commonly used drug and is highly durable in the environment, particularly in wastewater, which raises concerns about potential risks to animals and humans. We present an aptamer-based electrochemical sensor labelled with a redox probe which conformational change upon binding event is recorded by square-waved voltammetry. The electrochemical sensor operated in concentrations range from 2.5 pM to 250 μM in buffer. This technology provides a potential method to enable the monitoring of CBZ in treated water.
- 1 January 2024
- Published by AMA Service GmbH
- p. 177-178
Open AccessOT6.195 - Aptamer-based Electrochemical Sensor for the Monitoring of Carbamazepine in Freshwater Systems
Carbamazepine (CBZ) is an active compound in commonly used drug and is highly durable in the environment, particularly in wastewater, which raises concerns about potential risks to animals and humans. We present an aptamer-based electrochemical sensor labelled with a redox probe which conformational change upon binding event is recorded by square-waved voltammetry. The electrochemical sensor operated in concentrations range from 2.5 pM to 250 μM in buffer. This technology provides a potential method to enable the monitoring of CBZ in treated water.
- Open Access
- 27 August 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 216, 114642
Comparison of electrical and optical transduction modes of DNA-wrapped SWCNT nanosensors for the reversible detection of neurotransmitters.
- 27 August 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 216, 114642
Open AccessComparison of electrical and optical transduction modes of DNA-wrapped SWCNT nanosensors for the reversible detection of neurotransmitters.
- 27 March 2020
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 12 (15) , 17244-17253
In Vitro Cytocompatibility Assessment of Ti-Modified, Silicon-oxycarbide-Based, Polymer-Derived, Ceramic-Implantable Electrodes under Pacing Conditions
Polymer derived ceramics (PDC) have recently gained increased interest in the field of bioceramics. Among PDC’s, carbon rich silicon oxycarbide ceramics (SiOC) possess good combined electrical and mechanical properties. Their durability in aggressive environments and proposed cytocompatibility makes them an attractive material for fabrication of bio-MEMS devices such as pacemaker electrodes. The aim of the present study is to demonstrate the remarkable mechanical and electrical properties, biological response of PDCs modified with titanium (Ti) and their potential for application as pacemaker electrodes. Therefore, a new type of SiOC modified with Ti fillers was synthesized via PDC route using a Pt-catalyzed hydrosilylation reaction. Preceramic green bodies were pyrolyzed at 1000 °C under argon atmosphere to achieve amorphous ceramics. Electrical and mechanical characterization of SiCxO2(1-x)/TiOxCy ceramics revealed a maximum electrical conductivity of 101 S cm-1 and a flexural strength of maximal 1 GPa, which is acceptable for pacemaker applications. Ti incorporation is found to be beneficial for enhancing the electrical conductivity of SiOC ceramics and the conductivity values were increased with Ti doping and reached a maximum for the composition with 30 wt% Ti precursor. Cytocompatibility was demonstrated for the PDC SiOC ceramics as well as SiOC ceramics modified with Ti fillers. Cytocompatibility was also demonstrated for SiTiOC20 electrodes under pacing conditions by monitoring of cells in an in vitro 3D environment. Collectively, these data demonstrate the great potential of polymer derived SiOC ceramics to be used as pacemaker electrodes.
- 27 March 2020
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 12 (15) , 17244-17253
In Vitro Cytocompatibility Assessment of Ti-Modified, Silicon-oxycarbide-Based, Polymer-Derived, Ceramic-Implantable Electrodes under Pacing Conditions
Polymer derived ceramics (PDC) have recently gained increased interest in the field of bioceramics. Among PDC’s, carbon rich silicon oxycarbide ceramics (SiOC) possess good combined electrical and mechanical properties. Their durability in aggressive environments and proposed cytocompatibility makes them an attractive material for fabrication of bio-MEMS devices such as pacemaker electrodes. The aim of the present study is to demonstrate the remarkable mechanical and electrical properties, biological response of PDCs modified with titanium (Ti) and their potential for application as pacemaker electrodes. Therefore, a new type of SiOC modified with Ti fillers was synthesized via PDC route using a Pt-catalyzed hydrosilylation reaction. Preceramic green bodies were pyrolyzed at 1000 °C under argon atmosphere to achieve amorphous ceramics. Electrical and mechanical characterization of SiCxO2(1-x)/TiOxCy ceramics revealed a maximum electrical conductivity of 101 S cm-1 and a flexural strength of maximal 1 GPa, which is acceptable for pacemaker applications. Ti incorporation is found to be beneficial for enhancing the electrical conductivity of SiOC ceramics and the conductivity values were increased with Ti doping and reached a maximum for the composition with 30 wt% Ti precursor. Cytocompatibility was demonstrated for the PDC SiOC ceramics as well as SiOC ceramics modified with Ti fillers. Cytocompatibility was also demonstrated for SiTiOC20 electrodes under pacing conditions by monitoring of cells in an in vitro 3D environment. Collectively, these data demonstrate the great potential of polymer derived SiOC ceramics to be used as pacemaker electrodes.
- 27 September 2019
- Published by Elsevier
- p. 223-237
Carbon nanomaterials functionalized with macrocyclic compounds for sensing vapors of aromatic VOCs
- 27 September 2019
- Published by Elsevier
- p. 223-237
Carbon nanomaterials functionalized with macrocyclic compounds for sensing vapors of aromatic VOCs
- 6 May 2019
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 58 (29) , 9928-9932
Direct Synthesis of Multiplexed Metal‐Nanowire‐Based Devices by Using Carbon Nanotubes as Vector Templates
We present the synthesis of metal nanowires in a multiplexed device configuration using single‐walled carbon nanotubes (SWNTs) as nanoscale vector templates. The SWNT templates control the dimensionality of the wires, allowing precise control of their size, shape, and orientation; moreover, a solution‐processable approach enables their linear deposition between specific electrode pairs in electronic devices. Electrical characterization demonstrated the successful fabrication of metal nanowire electronic devices, while multiscale characterization of the different fabrication steps revealed details of the structure and charge transfer between the material encapsulated and the carbon nanotube. Overall the strategy presented allows facile, low‐cost, and direct synthesis of multiplexed metal nanowire devices for nanoelectronic applications.
- 6 May 2019
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 58 (29) , 9928-9932
Direct Synthesis of Multiplexed Metal‐Nanowire‐Based Devices by Using Carbon Nanotubes as Vector Templates
We present the synthesis of metal nanowires in a multiplexed device configuration using single‐walled carbon nanotubes (SWNTs) as nanoscale vector templates. The SWNT templates control the dimensionality of the wires, allowing precise control of their size, shape, and orientation; moreover, a solution‐processable approach enables their linear deposition between specific electrode pairs in electronic devices. Electrical characterization demonstrated the successful fabrication of metal nanowire electronic devices, while multiscale characterization of the different fabrication steps revealed details of the structure and charge transfer between the material encapsulated and the carbon nanotube. Overall the strategy presented allows facile, low‐cost, and direct synthesis of multiplexed metal nanowire devices for nanoelectronic applications.
- 30 April 2019
- Published by Wiley in Chempluschem
- Vol. 84 (9) , 1235-1238
A One‐Step Chemical Strategy for the Formation of Carbon Nanotube Junctions in Aqueous Solution: Reaction of DNA‐Wrapped Carbon Nanotubes with Diazonium Salts
A single‐step chemical strategy allows the formation of single‐walled carbon nanotube (SWCNT) molecular junctions in aqueous solution. SWCNTs were first wrapped with DNA to be water soluble and solution processable. Diazonium salts, which have been shown to react spontaneously with carbon nanotubes in water at room temperature, were then employed to covalently link SWCNT segments. The DNA wrapping of the nanotubes acted as a protective layer that limits the functionalization predominantly to the nanotube terminal ends, therefore allowing the assembly of linear SWCNT junctions. Upon increasing the concentration of the linker, we observed first the formation of side‐to‐end junctions, and eventually the assembly, through side‐to‐side interactions, of SWCNTs into bundles. This approach demonstrates the possibility of tuning the formation of linear and branched carbon nanotube junctions that in turn is of importance for the sustainable fabrication of solution‐processable CNT‐based nanoscale systems and devices.
- 30 April 2019
- Published by Wiley in Chempluschem
- Vol. 84 (9) , 1235-1238
A One‐Step Chemical Strategy for the Formation of Carbon Nanotube Junctions in Aqueous Solution: Reaction of DNA‐Wrapped Carbon Nanotubes with Diazonium Salts
A single‐step chemical strategy allows the formation of single‐walled carbon nanotube (SWCNT) molecular junctions in aqueous solution. SWCNTs were first wrapped with DNA to be water soluble and solution processable. Diazonium salts, which have been shown to react spontaneously with carbon nanotubes in water at room temperature, were then employed to covalently link SWCNT segments. The DNA wrapping of the nanotubes acted as a protective layer that limits the functionalization predominantly to the nanotube terminal ends, therefore allowing the assembly of linear SWCNT junctions. Upon increasing the concentration of the linker, we observed first the formation of side‐to‐end junctions, and eventually the assembly, through side‐to‐side interactions, of SWCNTs into bundles. This approach demonstrates the possibility of tuning the formation of linear and branched carbon nanotube junctions that in turn is of importance for the sustainable fabrication of solution‐processable CNT‐based nanoscale systems and devices.
- 6 March 2019
- Published by Elsevier in Materials Today: Proceedings
- Vol. 6, 306-309
Printed transducers using nanomaterials for gas sensing
- 6 March 2019
- Published by Elsevier in Materials Today: Proceedings
- Vol. 6, 306-309
Printed transducers using nanomaterials for gas sensing
- Open Access
- 14 August 2018
- Published by Wiley in Advanced Science
- Vol. 5 (10) , 1800596
Tuning the Coupling in Single‐Molecule Heterostructures: DNA‐Programmed and Reconfigurable Carbon Nanotube‐Based Nanohybrids
Herein a strategy is presented for the assembly of both static and stimuli‐responsive single‐molecule heterostructures, where the distance and electronic coupling between an individual functional nanomoiety and a carbon nanostructure are tuned via the use of DNA linkers. As proof of concept, the formation of 1:1 nanohybrids is controlled, where single quantum dots (QDs) are tethered to the ends of individual carbon nanotubes (CNTs) in solution with DNA interconnects of different lengths. Photoluminescence investigations—both in solution and at the single‐hybrid level—demonstrate the electronic coupling between the two nanostructures; notably this is observed to progressively scale, with charge transfer becoming the dominant process as the linkers length is reduced. Additionally, stimuli‐responsive CNT‐QD nanohybrids are assembled, where the distance and hence the electronic coupling between an individual CNT and a single QD are dynamically modulated via the addition and removal of potassium (K+) cations; the system is further found to be sensitive to K+ concentrations from 1 pM to 25 × 10−3m. The level of control demonstrated here in modulating the electronic coupling of reconfigurable single‐molecule heterostructures, comprising an individual functional nanomoiety and a carbon nanoelectrode, is of importance for the development of tunable molecular optoelectronic systems and devices.
- 14 August 2018
- Published by Wiley in Advanced Science
- Vol. 5 (10) , 1800596
Open AccessTuning the Coupling in Single‐Molecule Heterostructures: DNA‐Programmed and Reconfigurable Carbon Nanotube‐Based Nanohybrids
Herein a strategy is presented for the assembly of both static and stimuli‐responsive single‐molecule heterostructures, where the distance and electronic coupling between an individual functional nanomoiety and a carbon nanostructure are tuned via the use of DNA linkers. As proof of concept, the formation of 1:1 nanohybrids is controlled, where single quantum dots (QDs) are tethered to the ends of individual carbon nanotubes (CNTs) in solution with DNA interconnects of different lengths. Photoluminescence investigations—both in solution and at the single‐hybrid level—demonstrate the electronic coupling between the two nanostructures; notably this is observed to progressively scale, with charge transfer becoming the dominant process as the linkers length is reduced. Additionally, stimuli‐responsive CNT‐QD nanohybrids are assembled, where the distance and hence the electronic coupling between an individual CNT and a single QD are dynamically modulated via the addition and removal of potassium (K+) cations; the system is further found to be sensitive to K+ concentrations from 1 pM to 25 × 10−3m. The level of control demonstrated here in modulating the electronic coupling of reconfigurable single‐molecule heterostructures, comprising an individual functional nanomoiety and a carbon nanoelectrode, is of importance for the development of tunable molecular optoelectronic systems and devices.