Moala K. Bannavti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Moala K. Bannavti has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Keri C. Hornbuckle
University of Iowa 4105 Seamans Center
3 shared publications - Rachel F. Marek
University of Iowa 4105 Seamans Center
3 shared publications - Craig L. Just
University of Iowa
2 shared publications - Jacob C. Jahnke
Department of Civil and Environmental Engineering, IIHR-Hydroscience & Engineering, University of Iowa, Iowa City, Iowa 52242, United States
2 shared publications Craig L. Just
1 shared publication
Latest Publications
- Open Access
- 21 August 2023
- Published by American Chemical Society (ACS) in Environmental Science & Technology Letters
- Vol. 10 (9) , 762-767
Congener-Specific Emissions from Floors and Walls Characterize Indoor Airborne Polychlorinated Biphenyls
To reconcile the federal regulation of material polychlorinated biphenyl (PCB) concentrations with recently implemented state regulations of airborne PCBs, there is a need to characterize the relationship between PCB emissions from surfaces and air concentrations. We hypothesized that the magnitude and congener distribution of emissions from floors and walls fully account for the airborne PCBs measured in rooms constructed during the height of PCB production and sales. We measured emissions of PCB congeners from various wall and floor materials using polyurethane foam passive emission samplers before and after hexane wiping. Our results revealed that PCB emissions from flooring adequately predicted the magnitude and congener distribution of PCBs observed in the room air. Emissions varied by material within a single building (5 × 103 ng m-2 day-1 from wood panel walls to 3 × 104 ng m-2 day-1 from vinyl tile) and within the same room. Yet congener distributions between material emission PCB profiles and room air PCB profiles were statistically similar. Hexane wiping significantly reduced PCB emissions (>60%), indicating the importance of surface films as an ongoing source of airborne PCBs. The magnitude and congener distribution of material bulk concentrations did not explain that of material emissions or air concentrations. Passive measurements of polychlorinated biphenyl emissions from floors in a university building predict the concentrations of PCBs in room air.
- 21 August 2023
- Published by American Chemical Society (ACS) in Environmental Science & Technology Letters
- Vol. 10 (9) , 762-767
Open AccessCongener-Specific Emissions from Floors and Walls Characterize Indoor Airborne Polychlorinated Biphenyls
To reconcile the federal regulation of material polychlorinated biphenyl (PCB) concentrations with recently implemented state regulations of airborne PCBs, there is a need to characterize the relationship between PCB emissions from surfaces and air concentrations. We hypothesized that the magnitude and congener distribution of emissions from floors and walls fully account for the airborne PCBs measured in rooms constructed during the height of PCB production and sales. We measured emissions of PCB congeners from various wall and floor materials using polyurethane foam passive emission samplers before and after hexane wiping. Our results revealed that PCB emissions from flooring adequately predicted the magnitude and congener distribution of PCBs observed in the room air. Emissions varied by material within a single building (5 × 103 ng m-2 day-1 from wood panel walls to 3 × 104 ng m-2 day-1 from vinyl tile) and within the same room. Yet congener distributions between material emission PCB profiles and room air PCB profiles were statistically similar. Hexane wiping significantly reduced PCB emissions (>60%), indicating the importance of surface films as an ongoing source of airborne PCBs. The magnitude and congener distribution of material bulk concentrations did not explain that of material emissions or air concentrations. Passive measurements of polychlorinated biphenyl emissions from floors in a university building predict the concentrations of PCBs in room air.
- Open Access
- 25 May 2021
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 55 (14) , 9460-9468
Room-to-Room Variability of Airborne Polychlorinated Biphenyls in Schools and the Application of Air Sampling for Targeted Source Evaluation
Airborne polychlorinated biphenyl (PCB) concentrations are higher indoors than outdoors due to their historical use in building materials and their presence in modern paints and surface treatments. For some populations, including school children, PCB levels indoors result in inhalation exposures that may be greater than or equivalent to exposure through diet. In a school, PCB exposure may come from multiple sources. We hypothesized that there are both Aroclor and non-Aroclor sources within a single school and that PCB concentration and congener profiles differ among rooms within a single building. To evaluate this hypothesis and to identify potential localized sources, we measured airborne PCBs in nine rooms in a school. We found that schoolroom concentrations exceed outdoor air concentrations. Schoolroom concentrations and congener profiles also varied from one room to another. The concentrations were highest in the math room (35.75 ng m–3 ± 8.08) and lowest in the practice gym (1.54 ng m–3 ± 0.35). Rooms in the oldest wing of the building, originally constructed between 1920 and 1970, had the highest concentrations. The congener distribution patterns indicate historic use of Aroclor 1254 as well as modern sources of non-Aroclor congeners associated with paint pigments and surface coatings. Our findings suggest this noninvasive source identification method presents an opportunity for targeted source testing for more cost-effective prioritization of materials remediation in schools.
- 25 May 2021
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 55 (14) , 9460-9468
Open AccessRoom-to-Room Variability of Airborne Polychlorinated Biphenyls in Schools and the Application of Air Sampling for Targeted Source Evaluation
Airborne polychlorinated biphenyl (PCB) concentrations are higher indoors than outdoors due to their historical use in building materials and their presence in modern paints and surface treatments. For some populations, including school children, PCB levels indoors result in inhalation exposures that may be greater than or equivalent to exposure through diet. In a school, PCB exposure may come from multiple sources. We hypothesized that there are both Aroclor and non-Aroclor sources within a single school and that PCB concentration and congener profiles differ among rooms within a single building. To evaluate this hypothesis and to identify potential localized sources, we measured airborne PCBs in nine rooms in a school. We found that schoolroom concentrations exceed outdoor air concentrations. Schoolroom concentrations and congener profiles also varied from one room to another. The concentrations were highest in the math room (35.75 ng m–3 ± 8.08) and lowest in the practice gym (1.54 ng m–3 ± 0.35). Rooms in the oldest wing of the building, originally constructed between 1920 and 1970, had the highest concentrations. The congener distribution patterns indicate historic use of Aroclor 1254 as well as modern sources of non-Aroclor congeners associated with paint pigments and surface coatings. Our findings suggest this noninvasive source identification method presents an opportunity for targeted source testing for more cost-effective prioritization of materials remediation in schools.