Sourabh Sahu
Sourabh Sahu has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Ghanshyam Singh
Department of Electronics and Communication Engineering Malaviya National Institute of Technology Rajasthan Jaipur India mnit.ac.in
6 shared publicationsJalil Ali
5 shared publications- Ghanshyam Singh
Department of Electronics and Communication Engineering, Malaviya National Institute of Technology Jaipur, Jaipur, India
3 shared publications Preecha P. Yupapin
3 shared publications- Shailendra Kumar Tripathi
Department of Physics and Material Science, Jaypee University, Anoopshahr, India
2 shared publications Abhishek Godbole
Malaviya National Institute of Technology Jaipur, India
1 shared publication
Latest Publications
- 1 September 2024
- Published by Springer Nature
- p. 137-153
A Novel Surface Roughness Estimation and Optimization Model for Turning Process Using RSM-JAYA Method
- 1 September 2024
- Published by Springer Nature
- p. 137-153
A Novel Surface Roughness Estimation and Optimization Model for Turning Process Using RSM-JAYA Method
- Open Access
- 23 May 2024
- Published by Hindawi Limited in The Scientific World Journal
- Vol. 2024, 1-6
Design and Analysis of Digitally Tunable Transconductance Amplifier (DTTA) Using CNTFETs
Carbon nanotube-FETs (CNTFETs) have become a potential challenger because of their exceptional electrical properties and compatibility with conventional CMOS technology. The design and study of digitally tunable transconductance amplifiers (DTTAs) using CNTFETs are the main topics of this work. By utilizing the special characteristics of CNTFETs, the suggested DTTA design makes transconductance tunable, providing a versatile method of adjusting amplifier settings without requiring modifications to the hardware architecture. This study provides a complete description of the CNTFET modeling techniques utilized for realistic circuit simulations, along with a detailed analysis of the DTTA based on CNTFETs. The circuit is implemented using a 32nm CNTFET model and verified results with HSPICE.
- 23 May 2024
- Published by Hindawi Limited in The Scientific World Journal
- Vol. 2024, 1-6
Open AccessDesign and Analysis of Digitally Tunable Transconductance Amplifier (DTTA) Using CNTFETs
Carbon nanotube-FETs (CNTFETs) have become a potential challenger because of their exceptional electrical properties and compatibility with conventional CMOS technology. The design and study of digitally tunable transconductance amplifiers (DTTAs) using CNTFETs are the main topics of this work. By utilizing the special characteristics of CNTFETs, the suggested DTTA design makes transconductance tunable, providing a versatile method of adjusting amplifier settings without requiring modifications to the hardware architecture. This study provides a complete description of the CNTFET modeling techniques utilized for realistic circuit simulations, along with a detailed analysis of the DTTA based on CNTFETs. The circuit is implemented using a 32nm CNTFET model and verified results with HSPICE.
- Open Access
Design, Optimization and Performance Assessment of Single Port Film Bulk Acoustic Resonator through Finite Element Simulation
In this paper, the study is supported by design, FEA simulation, and practical RF measurements on fabricated single-port-cavity-based acoustic resonator for gas sensing applications. In the FEA simulation, frequency domain analysis was performed to enhance the performance of the acoustic resonator. The structural and surface morphologies of the deposited ZnO as a piezoelectric layer have been studied using XRD and AFM. The XRD pattern of deposited bulk ZnO film indicates the perfect single crystalline nature of the film with dominant phase (002) at 2θ = 34.58°. The AFM micrograph indicates that deposited piezoelectric film has a very smooth surface and small grain size. In the fabrication process, use of bulk micro machined oxide (SiO2) for the production of a thin membrane as a support layer is adopted. A vector network analyzer (Model MS2028C, Anritsu) was used to measure the radio frequency response of the resonators from 1 GHz to 2.5 GHz. As a result, we have successfully fabricated an acoustic resonator operating at 1.84 GHz with a quality factor Q of 214 and an effective electromechanical coupling coefficient of 10.57%.
Open AccessDesign, Optimization and Performance Assessment of Single Port Film Bulk Acoustic Resonator through Finite Element Simulation
In this paper, the study is supported by design, FEA simulation, and practical RF measurements on fabricated single-port-cavity-based acoustic resonator for gas sensing applications. In the FEA simulation, frequency domain analysis was performed to enhance the performance of the acoustic resonator. The structural and surface morphologies of the deposited ZnO as a piezoelectric layer have been studied using XRD and AFM. The XRD pattern of deposited bulk ZnO film indicates the perfect single crystalline nature of the film with dominant phase (002) at 2θ = 34.58°. The AFM micrograph indicates that deposited piezoelectric film has a very smooth surface and small grain size. In the fabrication process, use of bulk micro machined oxide (SiO2) for the production of a thin membrane as a support layer is adopted. A vector network analyzer (Model MS2028C, Anritsu) was used to measure the radio frequency response of the resonators from 1 GHz to 2.5 GHz. As a result, we have successfully fabricated an acoustic resonator operating at 1.84 GHz with a quality factor Q of 214 and an effective electromechanical coupling coefficient of 10.57%.
- Open Access
- 1 January 2023
- Published by Wiley in Journal of Sensors
- Vol. 2023 (1)
Detection of Biomolecules and Glucose Concentration in Blood Using a Subwavelength Grating Optical Biosensor
The research paper describes the design and simulation of an optical biosensor based on a ring resonator with a strip waveguide and a subwavelength grating waveguide. The main goal of the device is to function in low‐loss regions and prevent bending losses in ring resonator configuration. The finite‐difference‐time‐domain analysis is performed to simulate the device and to observe the sensing parameters. The biosensor is intended to be used for sensing biological molecules. The working principle of the sensor is to detect changes in the resonant wavelength caused by changes in the refractive index of biomaterials. By observing the shift in the resonant wavelength, the sensor can provide sensitive and reliable detection of biomolecules in solution. The evaluated sensitivity of the device is 206.3 nm/RIU, with a limit of detection of the order of 10−5 RIU. The device is also tested for the detection of glucose concentration in blood and found to be well‐suited for on‐chip applications. This makes it a promising candidate for use in a wide range of biosensing applications, from medical diagnostics to food safety testing.
- 1 January 2023
- Published by Wiley in Journal of Sensors
- Vol. 2023 (1)
Open AccessDetection of Biomolecules and Glucose Concentration in Blood Using a Subwavelength Grating Optical Biosensor
The research paper describes the design and simulation of an optical biosensor based on a ring resonator with a strip waveguide and a subwavelength grating waveguide. The main goal of the device is to function in low‐loss regions and prevent bending losses in ring resonator configuration. The finite‐difference‐time‐domain analysis is performed to simulate the device and to observe the sensing parameters. The biosensor is intended to be used for sensing biological molecules. The working principle of the sensor is to detect changes in the resonant wavelength caused by changes in the refractive index of biomaterials. By observing the shift in the resonant wavelength, the sensor can provide sensitive and reliable detection of biomolecules in solution. The evaluated sensitivity of the device is 206.3 nm/RIU, with a limit of detection of the order of 10−5 RIU. The device is also tested for the detection of glucose concentration in blood and found to be well‐suited for on‐chip applications. This makes it a promising candidate for use in a wide range of biosensing applications, from medical diagnostics to food safety testing.
- 21 July 2018
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 50 (8) , 307
High-Q and temperature stable photonic biosensor based on grating waveguides
- 21 July 2018
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 50 (8) , 307
High-Q and temperature stable photonic biosensor based on grating waveguides
- 5 July 2018
- Published by Springer Nature in Microsystem Technologies
- Vol. 25 (3) , 789-795
Effectiveness of Taguchi method for the optimization of narrowband optical filters based on grating waveguides
- 5 July 2018
- Published by Springer Nature in Microsystem Technologies
- Vol. 25 (3) , 789-795
Effectiveness of Taguchi method for the optimization of narrowband optical filters based on grating waveguides
- Open Access
- 16 June 2018
- Published by Springer Nature in Photonic Sensors
- Vol. 8 (3) , 248-254
Porous Silicon Based Bragg-Grating Resonator for Refractive Index Biosensor
- 16 June 2018
- Published by Springer Nature in Photonic Sensors
- Vol. 8 (3) , 248-254
Open AccessPorous Silicon Based Bragg-Grating Resonator for Refractive Index Biosensor
- 1 November 2017
- Published by Elsevier in Optics Communications
- Vol. 402, 408-412
Refractive index biosensor using sidewall gratings in dual-slot waveguide
- 1 November 2017
- Published by Elsevier in Optics Communications
- Vol. 402, 408-412
Refractive index biosensor using sidewall gratings in dual-slot waveguide
- 1 January 2016
- Published by Optica Publishing Group
- p. Th3A.60
Michelson Interferometer Based Refractive Index Biosensor
In this article Michelson interferometer based biosensor is proposeD.The device is compact in size and easy to fabricate and suitable for integration with other photonic devices. The proposed sensor exhibits a sensitivity of 225nm/RIU.
- 1 January 2016
- Published by Optica Publishing Group
- p. Th3A.60
Michelson Interferometer Based Refractive Index Biosensor
In this article Michelson interferometer based biosensor is proposeD.The device is compact in size and easy to fabricate and suitable for integration with other photonic devices. The proposed sensor exhibits a sensitivity of 225nm/RIU.