Akmal Irfan Majid
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Akmal Irfan Majid has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
Deendarlianto
8 shared publicationsIndarto
6 shared publications- Arif Widyatama
Department of Mechanical & Industrial Engineering, Faculty of Engineering, Universitas Gadjah Mada, Jl. Grafika No. 2, Yogyakarta, 55281, Indonesia
5 shared publications Adhika Widyaparaga
4 shared publications- Deendarlianto Deendarlianto
Universitas Gadjah Mada
4 shared publications - Okto Dinaryanto
Institut Teknologi Dirgantara Adisutjipto
3 shared publications
Latest Publications
- 20 November 2026
- Published by Elsevier in Biomass and Bioenergy
- Vol. 217
Tailoring pore structure and hydrogen adsorption mechanisms of sugarcane bagasse-derived activated carbon by ZnCl2 activation
- 20 November 2026
- Published by Elsevier in Biomass and Bioenergy
- Vol. 217
Tailoring pore structure and hydrogen adsorption mechanisms of sugarcane bagasse-derived activated carbon by ZnCl2 activation
- Open Access
- 26 October 2026
- Published by Wiley in ChemistrySelect
- Vol. 11 (40) , e74958
Upcycling Coffee Waste Into AC/NiO Electrodes for Supercapacitors
The conversion of spent coffee grounds into electrochemically active materials offers a route to integrate biomass waste valorization with aqueous energy storage. In this study, activated carbon derived from coffee‐ground waste (CGW‐AC) was prepared by KOH activation and subsequently combined with nickel oxide (NiO) through hydrothermal deposition to produce a CGW‐AC/NiO hybrid electrode. FTIR, Raman, XRD, SEM–EDS, and N 2 adsorption–desorption analyses confirmed the incorporation of crystalline NiO while preserving the hierarchical porous carbon framework. NiO incorporation reduced the BET surface area from 1189.24 to 552.77 m 2 ·g − 1 , indicating partial pore occupation, but substantially increased charge‐storage capability through the additional Faradaic contribution of NiO. In three‐electrode configuration under 1 M Na 2 SO 4 , CGW‐AC/NiO achieved a specific capacitance of 399 F·g − 1 , while CGW‐AC obtained a specific capacitance of 133 F·g − 1 at 1 A·g − 1 . Under two‐electrode configuration, the specific capacitance for CGW‐AC/NiO remains higher, reaching 90 F·g − 1 compared to 62 F·g − 1 for CGW‐AC. A capacitance retention of 87% for CGW‐AC/NiO after 6000 cycles suggests that the NiO present in the carbon structures are active sites that facilitates pesudocapacitance as also demonstrated by CV results. These results highlight the potential of coffee‐waste‐derived AC/NiO for hybrid electrodes in neutral aqueous supercapacitors.
- 26 October 2026
- Published by Wiley in ChemistrySelect
- Vol. 11 (40) , e74958
Open AccessUpcycling Coffee Waste Into AC/NiO Electrodes for Supercapacitors
The conversion of spent coffee grounds into electrochemically active materials offers a route to integrate biomass waste valorization with aqueous energy storage. In this study, activated carbon derived from coffee‐ground waste (CGW‐AC) was prepared by KOH activation and subsequently combined with nickel oxide (NiO) through hydrothermal deposition to produce a CGW‐AC/NiO hybrid electrode. FTIR, Raman, XRD, SEM–EDS, and N 2 adsorption–desorption analyses confirmed the incorporation of crystalline NiO while preserving the hierarchical porous carbon framework. NiO incorporation reduced the BET surface area from 1189.24 to 552.77 m 2 ·g − 1 , indicating partial pore occupation, but substantially increased charge‐storage capability through the additional Faradaic contribution of NiO. In three‐electrode configuration under 1 M Na 2 SO 4 , CGW‐AC/NiO achieved a specific capacitance of 399 F·g − 1 , while CGW‐AC obtained a specific capacitance of 133 F·g − 1 at 1 A·g − 1 . Under two‐electrode configuration, the specific capacitance for CGW‐AC/NiO remains higher, reaching 90 F·g − 1 compared to 62 F·g − 1 for CGW‐AC. A capacitance retention of 87% for CGW‐AC/NiO after 6000 cycles suggests that the NiO present in the carbon structures are active sites that facilitates pesudocapacitance as also demonstrated by CV results. These results highlight the potential of coffee‐waste‐derived AC/NiO for hybrid electrodes in neutral aqueous supercapacitors.
- Open Access
- 27 July 2023
- Published by Elsevier in Electrochimica Acta
- Vol. 467
Comparative study of electroreduction of iron oxide using acidic and alkaline electrolytes for sustainable iron production
- 27 July 2023
- Published by Elsevier in Electrochimica Acta
- Vol. 467
Open AccessComparative study of electroreduction of iron oxide using acidic and alkaline electrolytes for sustainable iron production
- 17 July 2020
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2248 (1) , 070003
Experimental study of the effects of input voltage on the transient temperature behaviors of thermoelectric mini-cold storage
The use of commonly used vapor compression cycle cold storage in fishing vessel is facing limitations to be widely applied in Indonesian fishermen since it consumes more energy and requires large space. Thermoelectric refrigerator is believed to be a promising option due to its simple design and low energy requirement. However, the Coefficient of Performance (CoP) of the system in current development is relatively low. Although many researches have been conducted to increase the CoP of the system But there is still lack of studies focused on effects of the important variables to cold storage performance. The present study aimed to investigate the effect of input voltage on thermoelectric cold storage chamber temperature in the form of transient behaviors. As a result, it was found that the increase of input voltage significantly affected the cooling performance, although in 6 V input voltage, the result is only a bit lower than 12 V with much lower energy use. In addition, the time needed to get steady state in 12 V was the fastest compared to the other input voltages. Those results can be used as design consideration of a portable thermoelectric cold storage.
- 17 July 2020
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2248 (1) , 070003
Experimental study of the effects of input voltage on the transient temperature behaviors of thermoelectric mini-cold storage
The use of commonly used vapor compression cycle cold storage in fishing vessel is facing limitations to be widely applied in Indonesian fishermen since it consumes more energy and requires large space. Thermoelectric refrigerator is believed to be a promising option due to its simple design and low energy requirement. However, the Coefficient of Performance (CoP) of the system in current development is relatively low. Although many researches have been conducted to increase the CoP of the system But there is still lack of studies focused on effects of the important variables to cold storage performance. The present study aimed to investigate the effect of input voltage on thermoelectric cold storage chamber temperature in the form of transient behaviors. As a result, it was found that the increase of input voltage significantly affected the cooling performance, although in 6 V input voltage, the result is only a bit lower than 12 V with much lower energy use. In addition, the time needed to get steady state in 12 V was the fastest compared to the other input voltages. Those results can be used as design consideration of a portable thermoelectric cold storage.
- 10 December 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2187 (1) , 020048
Design evaluation and thermal calculations of the developed automotive radiators for student formula SAE vehicle “Bimasakti”
Bimasakti is a single-seater formula vehicle manufactured by UGM students which compete annually in the Japan Student Formula SAE Competition. To prevent the engine overheating, a proper design of the radiator should be considered. The developed radiator is expected to control heat dissipated produced by the engine and maintain the optimal engine temperature. In this study, the technical evaluations towards 2 radiator designs (namely as BM-R1 and BM-R2) were conducted in the viewpoint of thermal calculations. Here, water was used as a coolant liquid inside the radiator. The vehicle used a KTM 450 SX-F engine (450 cc) as the prime mover with maximum power of 44 kW. As the design requirements, we assumed that: 7.33 kW of heat (from the engine) should be exchanged by the radiator, the coolant temperature from the engine was assumed to be 95°C, and the effectiveness is 0.25. As a result, the BM-R2 with the total heat transfer area of 2.86 m2 could dissipate the heat of 9.16 kW which was better than BM-R1. Furthermore, result of this analytical study is expected to be an engineering input towards the simulation study of the radiator performance.
- 10 December 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2187 (1) , 020048
Design evaluation and thermal calculations of the developed automotive radiators for student formula SAE vehicle “Bimasakti”
Bimasakti is a single-seater formula vehicle manufactured by UGM students which compete annually in the Japan Student Formula SAE Competition. To prevent the engine overheating, a proper design of the radiator should be considered. The developed radiator is expected to control heat dissipated produced by the engine and maintain the optimal engine temperature. In this study, the technical evaluations towards 2 radiator designs (namely as BM-R1 and BM-R2) were conducted in the viewpoint of thermal calculations. Here, water was used as a coolant liquid inside the radiator. The vehicle used a KTM 450 SX-F engine (450 cc) as the prime mover with maximum power of 44 kW. As the design requirements, we assumed that: 7.33 kW of heat (from the engine) should be exchanged by the radiator, the coolant temperature from the engine was assumed to be 95°C, and the effectiveness is 0.25. As a result, the BM-R2 with the total heat transfer area of 2.86 m2 could dissipate the heat of 9.16 kW which was better than BM-R1. Furthermore, result of this analytical study is expected to be an engineering input towards the simulation study of the radiator performance.
- 10 December 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2187 (1) , 050030
Plug and play manhole kit holder for storage tank: A comprehensive design analysis
A novel design of a manhole kit holder, namely “Plakhor” was developed by TBBM Boyolali of PT Pertamina (Persero). The device has an advantage of a plug and play system which has an important feature to assist the cleaning of storage tank confined space. The present report addressed the design considerations, mechanical test results, and stress analysis of the developed device. The design was developed by considering engineering standards of API 650 while the stress analysis was conducted using finite element analysis (FEA). Meanwhile, a series of mechanical tests such as tensile strength, bending, press, and torsion were also conducted to determine the mechanical strength of the material used in this design. The stress analysis results indicated that the design construction was safe enough to hold the manhole weight and in an excellent agreement to that of the physical test result.
- 10 December 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2187 (1) , 050030
Plug and play manhole kit holder for storage tank: A comprehensive design analysis
A novel design of a manhole kit holder, namely “Plakhor” was developed by TBBM Boyolali of PT Pertamina (Persero). The device has an advantage of a plug and play system which has an important feature to assist the cleaning of storage tank confined space. The present report addressed the design considerations, mechanical test results, and stress analysis of the developed device. The design was developed by considering engineering standards of API 650 while the stress analysis was conducted using finite element analysis (FEA). Meanwhile, a series of mechanical tests such as tensile strength, bending, press, and torsion were also conducted to determine the mechanical strength of the material used in this design. The stress analysis results indicated that the design construction was safe enough to hold the manhole weight and in an excellent agreement to that of the physical test result.
- Open Access
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1273 (1) , 012074
Effects of Fuel Injection Pressure to Fuel Consumption and Exhaust Gas Emissions of SI Engine
The present study investigated the effects of fuel injection pressure to fuel consumption and exhaust gas emissions for the Spark Ignition (SI) engine. A series of experiments were carried out in 4-cylinders gasoline engine with capacity of 1500 cc. The default fuel injection pressure was 2.8 kg/cm2. In this study, the fuel injection pressures were varied from 1.4 to 4.2 kg/cm2. The engine speeds were retained on 800, 2000, and 3000 rpm. Fuel consumption was evaluated by using a burette under static condition and a gas analyser was used to measure exhaust gas emission. As a result, fuel injection pressure affects significantly to the fuel consumption and exhaust gas emission. The lowest fuel consumption and gas (CO and HC) emissions were reached when the injection pressure was 2 kg/cm2 for all engine speeds. When the injection pressure indicated above and below the default engine specification, a higher fuel consumption and gas emission occurred. Therefore, a better control of the fuel injection system needs to be considered during the engine operation to reduce fuel consumption and exhaust gas emission.
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1273 (1) , 012074
Open AccessEffects of Fuel Injection Pressure to Fuel Consumption and Exhaust Gas Emissions of SI Engine
The present study investigated the effects of fuel injection pressure to fuel consumption and exhaust gas emissions for the Spark Ignition (SI) engine. A series of experiments were carried out in 4-cylinders gasoline engine with capacity of 1500 cc. The default fuel injection pressure was 2.8 kg/cm2. In this study, the fuel injection pressures were varied from 1.4 to 4.2 kg/cm2. The engine speeds were retained on 800, 2000, and 3000 rpm. Fuel consumption was evaluated by using a burette under static condition and a gas analyser was used to measure exhaust gas emission. As a result, fuel injection pressure affects significantly to the fuel consumption and exhaust gas emission. The lowest fuel consumption and gas (CO and HC) emissions were reached when the injection pressure was 2 kg/cm2 for all engine speeds. When the injection pressure indicated above and below the default engine specification, a higher fuel consumption and gas emission occurred. Therefore, a better control of the fuel injection system needs to be considered during the engine operation to reduce fuel consumption and exhaust gas emission.
- Open Access
- 29 October 2019
- Published by Universitas Negeri Yogyakarta in Jurnal Penelitian Saintek
- Vol. 24 (2) , 129-142
EXPERIMENTAL STUDY ON THE PHENOMENA ON THE SUCCESSIVE DROPLETS IMPACTING HOT COPPER SURFAC
- 29 October 2019
- Published by Universitas Negeri Yogyakarta in Jurnal Penelitian Saintek
- Vol. 24 (2) , 129-142
Open AccessEXPERIMENTAL STUDY ON THE PHENOMENA ON THE SUCCESSIVE DROPLETS IMPACTING HOT COPPER SURFAC
- Open Access
- 1 March 2019
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 13
Experimental investigation on the flow behavior during the solid particles lifting in a micro-bubble generator type airlift pump system
- 1 March 2019
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 13
Open AccessExperimental investigation on the flow behavior during the solid particles lifting in a micro-bubble generator type airlift pump system
- 1 November 2018
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 126, 39-51
The interfacial dynamics of the micrometric droplet diameters during the impacting onto inclined hot surfaces
- 1 November 2018
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 126, 39-51
The interfacial dynamics of the micrometric droplet diameters during the impacting onto inclined hot surfaces