Federico Karp
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Federico Karp has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Germán Abel Islan
Centro de Investigación y Desarrollo en Fermentaciones Industriales (CINDEFI), Departamento de Química, Facultad de Ciencias Exactas, Universidad Nacional de La Plata and CONICET, La Plata, Argentina
4 shared publications Julio A. Luna
Instituto de Desarrollo Tecnológico para la Industria Química (UNL-CONICET), Predio CCT CONICET Santa Fe, RN 168, Santa Fe 3000, Argentina
4 shared publications- Luciano N. Mengatto
Instituto de Desarrollo Tecnológico para la Industria Química, INTEC (Universidad Nacional del Litoral and CONICET), Santa Fe, Argentina
4 shared publications - Ludmila N. Turino
Instituto de Desarrollo Tecnológico para la Industria Química (UNL-CONICET), Predio CCT CONICET Santa Fe, RN 168, Santa Fe 3000, Argentina
4 shared publications Diana A. Estenoz
Instituto de Desarrollo Tecnológico para la Industria Química, INTEC (Universidad Nacional del Litoral and CONICET), Santa Fe (3000), Argentina
2 shared publications- Ignacio M. Helbling
INTEC (Universidad Nacional del Litoral - CONICET), 3450 Güemes, 3000, Santa Fe, Argentina.
2 shared publications
Latest Publications
- 26 September 2025
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 114 (12) , 104014
Progesterone-PLGA in situ formed implants: Structural parameters correlations with in vitro and in vivo mathematical models
- 26 September 2025
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 114 (12) , 104014
Progesterone-PLGA in situ formed implants: Structural parameters correlations with in vitro and in vivo mathematical models
- 30 October 2024
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 142 (5)
Dual drug delivery systems based on natural and synthetic polymer particles for isoniazid and rifampicin vehiculization
The purpose of this work is the design and characterization of novel systems based on micro and nanoparticles prepared from poly(lactic‐co‐glycolic) acid (PLGA), chitosan (CHT) and gelatin (GEL) for compartmentalization and dual release of rifampicin and isoniazid. The emulsion/evaporation method is employed for the preparation of PLGA based microparticles and nanoparticles. CHT and GEL are used for the preparation of microparticles by spray‐drying. Entrapment efficiencies are in the range of 35%–73% and 5%–29% for rifampicin and isoniazid in PLGA microparticles, respectively. For isoniazid GEL:CHT particles the entrapment efficiencies are within 82%–100%. Isoniazid shows a complete release at acid condition from GEL:CHT particles, while rifampicin release is maintained from GEL:CHT particles or displays an slightly increase from PLGA particles during buffer conditions. Antimycobacterial activity experiments show that the formulations present the ability to inhibit the bacterial growth in comparison with a control culture without treatment. Rifampicin PLGA and isoniazid GEL:CHT microparticles could be used for the preparation of a dual drug delivery system with each antibiotic in a single particulate compartment. GEL:CHT microparticles containing free isoniazid and rifampicin PLGA nanoparticles are a novel two compartment delivery system.
- 30 October 2024
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 142 (5)
Dual drug delivery systems based on natural and synthetic polymer particles for isoniazid and rifampicin vehiculization
The purpose of this work is the design and characterization of novel systems based on micro and nanoparticles prepared from poly(lactic‐co‐glycolic) acid (PLGA), chitosan (CHT) and gelatin (GEL) for compartmentalization and dual release of rifampicin and isoniazid. The emulsion/evaporation method is employed for the preparation of PLGA based microparticles and nanoparticles. CHT and GEL are used for the preparation of microparticles by spray‐drying. Entrapment efficiencies are in the range of 35%–73% and 5%–29% for rifampicin and isoniazid in PLGA microparticles, respectively. For isoniazid GEL:CHT particles the entrapment efficiencies are within 82%–100%. Isoniazid shows a complete release at acid condition from GEL:CHT particles, while rifampicin release is maintained from GEL:CHT particles or displays an slightly increase from PLGA particles during buffer conditions. Antimycobacterial activity experiments show that the formulations present the ability to inhibit the bacterial growth in comparison with a control culture without treatment. Rifampicin PLGA and isoniazid GEL:CHT microparticles could be used for the preparation of a dual drug delivery system with each antibiotic in a single particulate compartment. GEL:CHT microparticles containing free isoniazid and rifampicin PLGA nanoparticles are a novel two compartment delivery system.
- 15 December 2022
- Published by Springer Nature in Iranian Polymer Journal
- Vol. 32 (3) , 299-312
Antibiotic delivery based on poly(lactic-co-glycolic) acid and natural polymers: a biocomposite strategy
- 15 December 2022
- Published by Springer Nature in Iranian Polymer Journal
- Vol. 32 (3) , 299-312
Antibiotic delivery based on poly(lactic-co-glycolic) acid and natural polymers: a biocomposite strategy
- 1 October 2020
- Published by Springer Nature in Drug Delivery and Translational Research
- Vol. 10 (5) , 1255-1266
Design and evaluation of a recyclable intravaginal device made of ethylene vinyl acetate copolymer for bovine estrus synchronization
In bovine estrus synchronization, intravaginal devices made of silicone are used to administer exogenous progesterone with the aim of maintain plasmatic levels above 2 ng ml(-1)during the treatment. After their use, devices must be discarded. There is an important concern on the environmental impact of the disposal of these used products due mainly to the non-degradability of the silicone and to the residual content of the hormone. Different alternatives are being studied, and the use of ecological materials appears as the more important. The objective of the present contribution was to design and evaluate a recyclable intravaginal prototype using ethylene vinyl acetate copolymer (EVA). Devices were fabricated by an injection-molding technique and characterized in terms of dimensions, loading efficiency, release rate, and wing tension. An analysis was first conducted to compare three different matrices and two supports. Secondly, the best candidate prototype was assayed in both beef and dairy cattle. Finally, used matrices were recycled measuring the progesterone content in the resulting devices and testing them in vitro. According to release tests, no differences were observed between the three matrices both in vitro and in vivo. On the contrary, a better performance was achieved when a support with a more flexible Y shape was used in comparison with a rigid T geometry. Successful results were observed in non-lactating cows, with plasma concentrations above the threshold value defined for the synchronization therapy. However, lower progesterone levels resulted when devices were tested in animals with large milk production. By last, recycled matrices presented a similar initial content and in vitro release rate than original matrices. These findings could open the possibility to use recyclable EVA devices as an alternative to the non-degradable silicone intravaginal inserts. Future research must be carried out to optimize the performance of the recycled matrices in dairy cattle. Modifications of the release surface and/or the initial loading can give a solution to the lower values observed in these animals. Graphical abstract
- 1 October 2020
- Published by Springer Nature in Drug Delivery and Translational Research
- Vol. 10 (5) , 1255-1266
Design and evaluation of a recyclable intravaginal device made of ethylene vinyl acetate copolymer for bovine estrus synchronization
In bovine estrus synchronization, intravaginal devices made of silicone are used to administer exogenous progesterone with the aim of maintain plasmatic levels above 2 ng ml(-1)during the treatment. After their use, devices must be discarded. There is an important concern on the environmental impact of the disposal of these used products due mainly to the non-degradability of the silicone and to the residual content of the hormone. Different alternatives are being studied, and the use of ecological materials appears as the more important. The objective of the present contribution was to design and evaluate a recyclable intravaginal prototype using ethylene vinyl acetate copolymer (EVA). Devices were fabricated by an injection-molding technique and characterized in terms of dimensions, loading efficiency, release rate, and wing tension. An analysis was first conducted to compare three different matrices and two supports. Secondly, the best candidate prototype was assayed in both beef and dairy cattle. Finally, used matrices were recycled measuring the progesterone content in the resulting devices and testing them in vitro. According to release tests, no differences were observed between the three matrices both in vitro and in vivo. On the contrary, a better performance was achieved when a support with a more flexible Y shape was used in comparison with a rigid T geometry. Successful results were observed in non-lactating cows, with plasma concentrations above the threshold value defined for the synchronization therapy. However, lower progesterone levels resulted when devices were tested in animals with large milk production. By last, recycled matrices presented a similar initial content and in vitro release rate than original matrices. These findings could open the possibility to use recyclable EVA devices as an alternative to the non-degradable silicone intravaginal inserts. Future research must be carried out to optimize the performance of the recycled matrices in dairy cattle. Modifications of the release surface and/or the initial loading can give a solution to the lower values observed in these animals. Graphical abstract
- 1 April 2020
- Published by Elsevier in Carbohydrate Polymers
- Vol. 234, 115922
An analysis of the microencapsulation of ceftiofur in chitosan particles using the spray drying technology
- 1 April 2020
- Published by Elsevier in Carbohydrate Polymers
- Vol. 234, 115922
An analysis of the microencapsulation of ceftiofur in chitosan particles using the spray drying technology
- 18 November 2018
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 136 (12)
PLGA nano‐ and microparticles for the controlled release of florfenicol: Experimental and theoretical study
In this study, PLGA particle systems were studied for the controlled release of florfenicol, a broad spectrum antibiotic used in veterinary treatments. The emulsion‐solvent evaporation technique was used for particle preparation. To evaluate the particle size, entrapment efficiency, and drug release behavior, factors such as solvent type, emulsification time and methods, and drug to polymer ratio were investigated. The results showed that the use of ethyl acetate and 2.5 min of ultrasonication or 30 min of homogenization can lead to sub‐micron and micron‐sized particles, respectively. Sizes between 200–300 nm and 2–3 μm were obtained for ultrasonication and homogenization procedures, respectively. Entrapment efficiencies were around 20% for all systems and release profiles were size dependent. In addition, a mathematical model was implemented to simulate the florfenicol transport. The model predicts the florfenicol release and takes into account the particle size, polymer molecular weight, and autocatalytic polymer degradation. Simulation results are in good agreement with experimental results. © 2018 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2019, 136, 47248.
- 18 November 2018
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 136 (12)
PLGA nano‐ and microparticles for the controlled release of florfenicol: Experimental and theoretical study
In this study, PLGA particle systems were studied for the controlled release of florfenicol, a broad spectrum antibiotic used in veterinary treatments. The emulsion‐solvent evaporation technique was used for particle preparation. To evaluate the particle size, entrapment efficiency, and drug release behavior, factors such as solvent type, emulsification time and methods, and drug to polymer ratio were investigated. The results showed that the use of ethyl acetate and 2.5 min of ultrasonication or 30 min of homogenization can lead to sub‐micron and micron‐sized particles, respectively. Sizes between 200–300 nm and 2–3 μm were obtained for ultrasonication and homogenization procedures, respectively. Entrapment efficiencies were around 20% for all systems and release profiles were size dependent. In addition, a mathematical model was implemented to simulate the florfenicol transport. The model predicts the florfenicol release and takes into account the particle size, polymer molecular weight, and autocatalytic polymer degradation. Simulation results are in good agreement with experimental results. © 2018 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2019, 136, 47248.
- 15 September 2017
- Published by SAGE Publications in Journal of Elastomers & Plastics
- Vol. 50 (5) , 391-402
Recyclable amitraz-ethylene vinyl acetate strips used for beehives treatment against Varroa destructor
In this work, a new recyclable ethylene-vinyl acetate (EVA)-based strip impregnated with amitraz (AMZ) was prepared, characterized, and evaluated for the treatment of Apis mellifera against Varroa destructor. Bees are important for natural pollination, honey, and related goods production. Varroa destructor is currently considered one of the major pests and important efforts around the world are focused on methods for varroasis treatment. The procedure of strips preparation presented in this work consisted of two steps: impregnation and molding of impregnated pellets. Differential scanning calorimetry and gas chromatography–mass spectrometry analyses confirmed that AMZ molecule resisted the impregnation and molding conditions. The strips were sufficiently strong to resist destruction by the bees. The final infestation was lower in the hives treated with AMZ/EVA strips than in those treated with commercial strips. In order to check the possibility of recycling, strips were cut into little pieces and were subjected to total AMZ extraction. Finally, the fragments were exposed to re-impregnation and molding. The strips prepared after the recycling process presented the same shape and AMZ load than fresh strips.
- 15 September 2017
- Published by SAGE Publications in Journal of Elastomers & Plastics
- Vol. 50 (5) , 391-402
Recyclable amitraz-ethylene vinyl acetate strips used for beehives treatment against Varroa destructor
In this work, a new recyclable ethylene-vinyl acetate (EVA)-based strip impregnated with amitraz (AMZ) was prepared, characterized, and evaluated for the treatment of Apis mellifera against Varroa destructor. Bees are important for natural pollination, honey, and related goods production. Varroa destructor is currently considered one of the major pests and important efforts around the world are focused on methods for varroasis treatment. The procedure of strips preparation presented in this work consisted of two steps: impregnation and molding of impregnated pellets. Differential scanning calorimetry and gas chromatography–mass spectrometry analyses confirmed that AMZ molecule resisted the impregnation and molding conditions. The strips were sufficiently strong to resist destruction by the bees. The final infestation was lower in the hives treated with AMZ/EVA strips than in those treated with commercial strips. In order to check the possibility of recycling, strips were cut into little pieces and were subjected to total AMZ extraction. Finally, the fragments were exposed to re-impregnation and molding. The strips prepared after the recycling process presented the same shape and AMZ load than fresh strips.
- 1 July 2017
- Published by Elsevier in Microchemical Journal
- Vol. 133, 182-187
A novel fast quality control strategy for monitoring spoilage on mayonnaise based on modeling second-order front-face fluorescence spectroscopy data
- 1 July 2017
- Published by Elsevier in Microchemical Journal
- Vol. 133, 182-187
A novel fast quality control strategy for monitoring spoilage on mayonnaise based on modeling second-order front-face fluorescence spectroscopy data