FMFaycal Mounaim

Faycal Mounaim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Faycal Mounaim has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Toward an Energy-Efficient High-Voltage Compliant Visual Intracortical Multichannel Stimulator

    by Hasanuzzaman, Bahareh G. Motlagh, Faycal Mounaim, Ahmad Hassan, Rabin Raut, Mohamad Sawan

    We present, in this paper, a new multichip system aimed toward building an implantable visual intracortical stimulation device. The objective is to deliver energy-optimum pulse patterns to neural sites with needed compliance voltage across high electrode-tissue interface impedance of implantable microelectrodes. The first chip is an energy-efficient stimuli generator (SG), and the second one is a high-impedance microelectrode array driver (MED) output stage. The four-channel SG produces rectangular, half-sine, plateau-sine, and other types of current pulse with stimulation current ranging from 2.32 to 220 μA per channel. The microelectrode array driver is able to deliver 20 V per anodic or cathodic phase across the microelectrode-tissue interface for ±13 V power supplies. The MED supplies different current levels with the maximum value of 400 μA per input and 100 μA per output channel simultaneously to 8-16 stimulation sites through microelectrodes, connected either in bipolar or monopolar configuration. Both chips receive power via inductive link and data through capacitive coupling. The SG and MED chips have been fabricated in 0.13-μm CMOS and 0.8-μm 5-/20-V CMOS/double-diffused metal-oxide-semiconductor technologies. The measured dc power budgets consumed by low- and mid-voltage chips are 2.56 and 2.1 mW consecutively. The system, modular in architecture, is interfaced with a newly developed platinum-coated pyramidal microelectrode array. In vitro test results with 0.9% phosphate buffer saline show the microelectrode impedance of 70 kΩ at 1 kHz.


  • Analysis, Modeling, and Mitigation of Parasitic Resonances in Integrated Metallic Seal Rings

    by M. Jacques, S. Bouvier, D. Denis, D. Patel, A. Samani, M. G. Saber, F. Mounaim, J. Gauthier, D. V. Plant

    The cause of a measured -1.4-dB dip at 80 GHz in a silicon capacitor was investigated and determined to be the primary resonance of the integrated metal seal ring (SR) enclosing the component. Specifically, the proximity of a capacitor electrode to the SR was found to activate two parasitic, parallel, and opencircuited coplanar strip transmission lines (TLs), each having their λ/2 resonance at this frequency. This model was confirmed with 3-D finite-element method electromagnetic simulations and measurements of modified SRs. Building on the proposed TL interpretation of the problem, an ultra-broadband equivalent circuit model was developed for such capacitors, successfully replicating the measured SR resonance. Then, the fundamental resonance frequency and related quality factor of various-sized integrated metal SRs were accurately predicted. Finally, potential solutions to damp or cancel such parasitic resonances were investigated. Although cutting the SR at selected locations to disable the parasitic lines was experimentally proven to be successful, damping the parasitic signal with highly doped silicon is found to be the best option in terms of effectiveness and practical implementation. Novel solutions, analogous to the use of radio frequency terminations, were also tested. This paper, to the best of our knowledge, is the first extensive characterization of parasitic resonance afflicting electronics enclosed by an integrated metal SR. The analysis, equivalent circuit model, and solutions reported here can be directly applied to arrays of components or circuits, and are scalable to any device size and operating frequency.


  • Toward A Fully Integrated Neurostimulator With Inductive Power Recovery Front-End

    by Fayçal Mounaim, Mohamad Sawan

    In order to investigate new neurostimulation strategies for micturition recovery in spinal cord injured patients, custom implantable stimulators are required to carry-on chronic animal experiments. However, higher integration of the neurostimulator becomes increasingly necessary for miniaturization purposes, power consumption reduction, and for increasing the number of stimulation channels. As a first step towards total integration, we present in this paper the design of a highly-integrated neurostimulator that can be assembled on a 21-mm diameter printed circuit board. The prototype is based on three custom integrated circuits fabricated in High-Voltage (HV) CMOS technology, and a low-power small-scale commercially available FPGA. Using a step-down approach where the inductive voltage is left free up to 20 V, the inductive power and data recovery front-end is fully integrated. In particular, the front-end includes a bridge rectifier, a 20-V voltage limiter, an adjustable series regulator (5 to 12 V), a switched-capacitor step-down DC/DC converter (1:3, 1:2, or 2:3 ratio), as well as data recovery. Measurements show that the DC/DC converter achieves more than 86% power efficiency while providing around 3.9-V from a 12-V input at 1-mA load, 1:3 conversion ratio, and 50-kHz switching frequency. With such efficiency, the proposed step-down inductive power recovery topology is more advantageous than its conventional step-up counterpart. Experimental results confirm good overall functionality of the system.


  • Long-term monitoring of electrochemical parameters from stimulated neural tissues

    by Faycal Mounaim, Guillaume Lesbros, Mohamad Sawan

    The electrode-tissues interface (ETI) is one of the key issues for the safety, reliability and efficiency of implantable devices such as stimulators and sensors. The aim of this paper is to report an implantable telemetry device, based on a full custom integrated circuit (IC) to monitor the ETI. The proposed system performs various types of measurements, such as impedance spectroscopy, cyclic voltammetry, and galvanostatic double pulse method. Hence, the evolution of various electrochemical parameters of the ETI such as complex impedance, faradic resistance, double layer capacity, rheobase current, and chronaxy time, could be monitored long time after implantation. The full custom IC has been designed and fabricated with the CMOS 0.18μm technology. The circuit occupies a silicon area of 2mm 2 , and consumes less than 3mW. Characterisation and in-vitro experimental results validate the full functionalities of the implantable monitoring system including the custom IC.


  • Implantable Electronic Device Dedicated to Neural Stimulation and Sensing

    by F. Mounaim, M. Sawan

    This paper presents the design and implementation of a new implantable electronic device dedicated for neural stimulation and monitoring. In addition to neuro-stimulation, this device includes impedance telemetry capabilities. The architecture of the proposed device is presented with a focus on its impedance measurement and telemetry. Assuming an equivalent parallel RC network for the electrodes-tissues contact impedance, resistance and capacitance can be measured with less than 5% and 15% errors respectively. Data is sent wirelessly to an external controller at 1 kbps data transmission rate.

  • Bidirectional high data rate transmission interface for inductively powered devices

    by J.F. Gervais, J. Coulombe, F. Mounaim, M. Sawan

    High data transfer rates in the order of 1 Mbit/s are now in demand for some inductively powered devices, but communication needs to be made without compromising power transfer and its efficiency. This paper compares different modulation schemes and proposes an interface to satisfy demanding bidirectional transmission needs. New demodulation approaches are used for phase and amplitude modulation and an adapted configurable protocol is presented. A complete integrated system is under design with a submicron technology. A transfer rate of 1.13 Mbit/s has been obtained with a discrete component prototype for amplitude demodulation.