AIAndi Muhammad Ilyas

Andi Muhammad Ilyas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andi Muhammad Ilyas has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Hybrid DE–NSGA-II Framework for Stochastic Multi-Objective Optimal Power Flow Considering Wind Uncertainty: Pareto-Based Analysis on a Real Transmission System

    by Andi Muhammad Ilyas, Iswan, Agus Siswanto

    This paper proposes a stochastic multi-objective optimal power flow (MO-OPF) framework that incorporates wind power uncertainty using a scenario-based modeling approach. A hybrid Differential Evolution–Non-dominated Sorting Genetic Algorithm II (DE–NSGA-II) is introduced to enhance convergence speed and solution diversity compared to conventional NSGA-II. The proposed model simultaneously minimizes generation cost, transmission losses, and emission levels while satisfying system operational constraints. The methodology is validated on a real transmission network representing the Sulawesi power system. Simulation results show that the proposed approach achieves significant performance improvements, where generation cost is reduced from 10,101 to 3,740.7, transmission losses decrease from 62.955 to 24.65, and emission levels are lowered from 14,571 to 4,101.9 across the obtained Pareto solutions. These results demonstrate the capability of the model to effectively balance conflicting objectives under wind power uncertainty. Furthermore, the generated Pareto front exhibits a well-distributed and non-linear structure, indicating strong diversity and robustness of the hybrid DE–NSGA-II algorithm in exploring the solution space. The obtained solutions reveal clear trade-offs among economic, technical, and environmental objectives, providing flexibility for system operators in decision-making. These findings confirm that the proposed framework is effective and suitable for modern power system operation with high penetration of renewable energy sources.

  • Open Access

    Identification of critical buses in the Sulbagsel electrical system network integrated with wind power plants

    by Andi Muhammad Ilyas, Agus Siswanto, Muhammad Natsir Rahman

    The growing deployment of renewable energy has become increasingly important as conventional fossil-based generation faces sustainability and resource limitations. On Sulawesi Island, Indonesia, wind energy contributes to the regional grid through several wind power plants, whose fluctuating generation introduces operational concerns for system stability. This study investigates the stability performance of the Sulbagsel 78-bus network by pinpointing vulnerable buses and examining the effects of wind power variability. A hybrid stability index (HSI), which integrates multiple stability indicators, is applied to obtain a more robust assessment. The analysis shows that the entire system operates within a secure margin, with all index values remaining below the critical limit (<1). The most sensitive areas are located on the transmission paths connecting Bus 56 Sidera–Bus 57 Sidera 70 kV (0.02268), Bus 38 Bosowa–Bus 40 Pangkep (0.02220), and Bus 73 Powatu 150 kV–Bus 74 Powatu 70 kV (0.02187). In contrast, the Bus 24 Tanjung Bunga–Bus 25 Bontoala corridor demonstrates the strongest stability margin (0.00026). These results indicate that the variability of wind generation does not impose significant negative impacts on the overall stability of the Sulbagsel power system.

  • Daily Electricity Load Forecasting in Ternate City Using ELM

    by Andi Muhammad Ilyas, Muhammad Natsir Rahman, Aldi Aswat, Faris Syamsuddin, Suparman Suparman, Bayu Adrian Ashad, Agus Siswanto

    The continuously increasing growth of electricity demand necessitates accurate and systematic planning of electric power systems to ensure power flow quality and system reliability. Ternate City, as one of the major activity centers in North Maluku Province, has experienced a substantial rise in electricity consumption, thereby requiring an effective and reliable load forecasting approach. This study aims to predict the daily electricity load in Ternate City using the Extreme Learning Machine (ELM) method. The analysis is conducted using historical electricity load data, which are processed through data preprocessing stages, dataset partitioning into training and testing sets, and ELM-based modeling. The performance of the proposed model is evaluated using the Mean Absolute Percentage Error (MAPE). The results indicate that the MAPE values for the training dataset range from 5.84% to 13.63%, corresponding to very good to good performance categories. Meanwhile, the testing dataset yields MAPE values ranging from 13.45% to 33.09%, which fall within the good to sufficient performance categories. Furthermore, the prediction results are able to accurately capture daily electricity load fluctuation patterns from Monday to Sunday, including peak load periods. Based on these findings, the ELM method demonstrates strong potential as a reliable approach to support electric power system planning and to enhance the quality and reliability of electricity supply in Ternate City.

  • Open Access

    PREDIKSI KUALITAS AIR DANAU LAGUNA DI TERNATE MENGGUNAKAN ARTIFICIAL NEURAL NETWORK

    by Muhammad Ilyas

    Prediksi kualitas air Danau Laguna di Kota Ternate sangat penting untuk mendukung pengelolaan ekosistem dan kebutuhan masyarakat sekitar. Penelitian ini bertujuan memprediksi parameter pH, suhu, nitrat, dan fosfat pada tahun 2026 menggunakan empat metode: Multiple Linear Regression (MLR), Random Forest Regression (RF), Support Vector Regression (SVR), dan Artificial Neural Network (ANN). Data yang digunakan merupakan pengukuran tahun 2017, 2023, dan 2024. Hasil prediksi menunjukkan perbedaan performa antarmetode. Untuk pH, prediksi 2026 berkisar antara 6.54–8.15, dengan RF memberikan nilai tertinggi dan ANN nilai terendah. Prediksi suhu berada di kisaran 31.03–31.86 °C, sedangkan nitrat diperkirakan 0.0888–0.114 mg/L, dan fosfat 0.0433–0.0752 mg/L. ANN menunjukkan akurasi terbaik untuk pH, sedangkan RF cenderung lebih baik pada suhu. Perbedaan hasil prediksi ini menegaskan adanya hubungan non-linear antarparameter kualitas air yang lebih kompleks daripada model linear sederhana. Prediksi kualitas air tahun 2026 memberikan gambaran awal kondisi Danau Laguna yang dapat digunakan sebagai dasar perencanaan pengelolaan, konservasi, dan pengambilan keputusan terkait kualitas air. Hasil ini juga menekankan efektivitas penggunaan metode kecerdasan buatan, khususnya ANN, dalam memodelkan dan memprediksi kondisi kualitas air di ekosistem perairan tropis.

  • Open Access

    Sea Water Distillation Design Using Renewable Energy for Drinking Water

    by Andi Muhammad Ilyas, Yuliana Yuliana, Muhammad Natsir Rahman, Mochammad Apriyadi Hadi Sirad, Fahrizal Djohar, Hasanuzzaman, Zulaeha Mabud

    The increase in drinking water needs in Ternate City is ttriggered by very rapid population growth. Population growth has resulted in the conversion of forests into housing which has resulted in reduced water catchment areas. In the end, several locations experienced a decline in water quality from fresh to brackish. To overcome the decline in the volume and quality of clean water, a plan is being made to distill sea water into fresh water. The method used in this research is the experimental method. Solar desalination is a process where solar energy is utilized to putify the fresh water from saline/brackish water for drinking purposes, in charging of the batteries, research laboratories. Experimental results with a distillation flow area of 325 cm with an average volume of 43.7 ml. Tests with a distillation drain area of 650 cm produced 76.0 ml of fresh water. Experiments with a distillation flow area of 975 cm produced an average of 106.3 ml of fresh water. The effectiveness of distillation occurs at the widest drainage. The price of fresh water per milliliter is IDR 1.41 cheaper than bottled water, namely IDR. 6.66 per milliliter. The results of research on the salinity of salt water to fresh water show that the salinity of salt water is 35 ppt, while the salinity of distilled water is 0, this shows that the result of distillation is fresh water that can be consumed.

  • Forecasting South Sulawesi Electrical Energy Consumption Using Artificial Neural Network

    by Sri Mawar Said, Andi Muhammad Ilyas

    Electrical Energy must be provided in an amount according to needs. Energy that exceeds consumption needs causes power loss. On the other hand, when electricity is scarce, it causes blackouts. To produce electrical energy that meets these needs, there must be a plan for the provision of electrical energy which is carried out by forecasting electricity consumption. Therefore, forecasting electricity consumption is very important to ensure electricity efficiency. This research was conducted in the province of South Sulawesi, Indonesia. The research method used is the Artificial Neural Network (ANN) method. The results of forecasting energy consumption show that the Artificial Neural Network method, Network Type back-propagation, and the TRAINGDX training function of 1480.133602 MW are closest to the target value of 1480.167515 MW or a difference of 0.033913 MW, Mean Square Error (MSE) value is 0.000002131. TRAINCGB is 1480.115899 MW or a difference of 0.051616 MW, the Mean Square Error (MSE) value is 0.000003226. This forecast shows that the results are accurate.

  • Real-Time Optimal Power Flow of South Sulawesi Network System That Integrated Wind Power Plant Based on Artificial Intelligence

    by Andi Muhammad Ilyas, Ansar Suyuti, Indar Chaerah Gunadin, Sri Mawar Said

    Rozwój i wykorzystanie technologii są zawsze wprost proporcjonalne do zapotrzebowania na energię elektryczną. Badania przepływu mocy w czasie rzeczywistym służą do oceny wpływu wahań generacji wiatrowej na istniejące systemy konwencjonalne. Badania przeprowadzono na systemie sieci elektroenergetycznej Południowego Sulawesi przy użyciu metody Modified Improved Particle Swarm Optimization (MIPSO). Wyniki w czasie rzeczywistym pokazują, że strata mocy w systemie konwencjonalnym, który jest połączony z elektrowniami wiatrowymi, wynosi 63.9208 WM, czyli mniej niż strata mocy w systemie konwencjonalnym, która wynosi 85,9440 WM. Podobnie, koszt systemu wytwórczego podłączonego do elektrowni wiatrowej wynosi 233686622 USD/godz., czyli jest niższy niż konwencjonalna moc systemu wynosząca 23503,444 USD/godz., co zmniejsza koszty lub wydajność o 0,5735%/godz. Analiza w czasie rzeczywistym optymalnego przepływu mocy za pomocą MIPSO może być wykorzystana do określenia wpływu zmian mocy generowanej przez elektrownie wiatrowe na konwencjonalny system sieci energetycznej południowo-zachodniego Sulawesi.. (Optymalny przepływ mocy w czasie rzeczywistym w systemie sieci South Sulawesi, który zintegrował elektrownię wiatrową w oparciu o sztuczną inteligencję)

  • Open Access

    Real-time voltage stability monitoring model of wind power plant penetration in electrical power system networks

    by A M Ilyas, A Suyuti, I C Gunadin, S M Said

    The intermittent output power of wind power plants can affect the stability of the power grid, so a real-time monitoring model is needed. This study uses data from the southern Sulawesi network which is interconnected with wind power plants in real-time, and the IEEE 30 bus data is used as method validation. The method used is the New Voltage Stability Index (NVSI) based on Matlab. The results of the stability index on the IEEE 30 bus data are < 1 or are at the standard of stable criteria, namely 0.95 p.u. The result of the stability index of the South Sulawesi network is line number 49 from Latuppa to Poso has the highest value of 0.0473, the second is line number 18 from Bosowa to Tello is 0.0390, and the third is line number 24 from Tello 30kV to Barawaja is 0.0221, the other bus voltages have lower values. So it can be concluded that the network of South Sulawesi is stable, and intermittent wind power has no effect on voltage stability.


  • Open Access

    Analysis of Transmission Line Stability for Sulselbar Interconnection System with the Penetration of Renewable Energy to Prevent Voltage Collapse

    by I C Gunadin, A Suyuti, A M Ilyas, A Siswanto

    There are three main requirements to meet the criteria both in the electric power system, namely reliability, quality, and stability. Stability is the ability of the system to return to work normally after experiencing interference. System stability analysis is a guide for operators to detect or prevent voltage drops and power outages. This research discusses the stability of the 150 KV electrical system in South Sulawesi before and after interconnection with the Sidrap and Jeneponto Wind Power Plant. The method used is the Line Stability Index (Lmn Index) to view the voltage profile. Index Lmn coding is run and simulated using Matlab. Validation is done by IEEE 14 bus simulation data, and comparing the results of the analysis before and after penetration with PLTB. The study was conducted on the Sulselbar 150 KV system before penetration with PLTB, namely 44 buses, 14 generators, and 52 lines / networks. The highest Lmn index result is the network from bus 38 to bus 39 that is equal to 0.0292. Second is bus 15 to bus 16 which is 0.0291, and third is bus 40 to 42 that is 0.0273. After penetration with PLTB Sidrap and Jeneponto, the number of generators will be 16 generators. The highest Lmn index results are from bus 38 to 39 that is 0.0292, then bus 15 to bus 16 that is 0.0290 ranks second, and bus 40 to 42 equals 0.0272 or keeps the third order. After the sidrap load bus is converted to a bus generator, the Lmn index before in reactive power supplied to the load by a generator is a certain thing, this condition must be maintained so that the plant continues to work in stable conditions.


  • Open Access

    Optimal Power Flow the Sulselrabar 150 KV system before and after the penetration of wind power plants considering power loss and generation costs

    by A M Ilyas, A Suyuti, I C Gunadin, A Siswanto

    Optimal Power Flow (OPF) is to optimize power flow in interconnection systems to decrease production costs and increase system reliability, quality, and stability. This research was conducted on power generation 150 KV systems in South Sulawesi, Southeast Sulawesi, and West Sulawesi, abbreviated as Sulselrabar. The number of buses is 44, 15 generator buses before penetration with the Sidrap Wind Power Plant (PLTB), and 16 bus generators after penetration with PLTB. The method used in this study is Improved Particle Swarm Optimization (IPSO) and Lagrange. The results showed that IPSO showed better results compared to Lagrange and the results of existing systems.