Evangelos Pateras
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Evangelos Pateras has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
A. I. Kouroupaki
Biomedical Department, Course of Optics and Optometry, University of West Attica, Athens, Greece
2 shared publications- Aristeidis Chandrinos
Optics and Optometry Sector, Department of Biomedical Sciences, Faculty of Health Sciences, University of West Attica (UNIWA), Athens, Greece
2 shared publications C. W. Fowler
Ophthalmic and Physiological Optics Research Group. Vision Sciences Department, Aston University, Birmingham B4 7ET, UK
2 shared publicationsCh. Koufala
Biomedical Department, Course of Optics and Optometry, Greece
2 shared publicationsK. Karabatsas
Biomedical Department, Course of Optics and Optometry, University of West Attica, Athens, Greece
2 shared publicationsA. Nousi
Department of Biomedical Sciences, Course of Optics and Optometry, University of West Attica, Greece
1 shared publication
Latest Publications
- Open Access
- 1 August 2025
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 17, 255-268
Assessment of Visual Function Using Yellow-Tinted Filter in Patients with Pre-Perimetric and Early Open Angle Glaucoma
Purpose: This study aimed to assess the effect of an external yellow-tinted filter (KIROS 1– 400 lens) on visual function in patients with pre-perimetric glaucoma (PPG) and early primary open-angle glaucoma (POAG). The primary outcomes were contrast sensitivity (CS) and visual field (VF) indices assessed using standard automated perimetry (SAP). Methods: This comparative observational, within-subject study included 30 patients with PPG (30 eyes) and 50 with POAG (50 eyes) recruited from the Ophthalmology Department of the 401 General Military Hospital, Athens, between January and December 2022. CS was measured using the Pelli-Robson chart. VF indices, including mean deviation (MD), pattern standard deviation (PSD), visual field index (VFI), and Glaucoma Hemifield Test (GHT) classifications, were assessed with SAP with the 24– 2 SITA-standard strategy on the Humphrey Field Analyzer II 740. All testing was performed both with and without the yellow filter KIROS 1– 400 (Essilor International) in the same eyes. Results: The KIROS 1– 400 filter significantly enhanced CS in both PPG and POAG eyes, increasing the median logCS by 0.03. However, while statistically significant, this improvement may not be clinically meaningful. In contrast, no significant changes were observed in the VF indices (MD, PSD, and VFI) when the filter was applied. Analysis of GHT results revealed that the filter reduced borderline classifications and showed high precision (0.733) and recall (0.846) for “outside normal limits” classifications. However, the agreement between the filtered and unfiltered GHT results was fair. Conclusion: The KIROS 1– 400 filter significantly enhanced CS in patients with PPG and POAG without notable effects on the VF indices. However, caution is advised when interpreting GHT results obtained with yellow-tinted filters. Further studies are recommended to evaluate the filter’s long-term clinical benefits and its potential role in glaucoma management.
- 1 August 2025
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 17, 255-268
Open AccessAssessment of Visual Function Using Yellow-Tinted Filter in Patients with Pre-Perimetric and Early Open Angle Glaucoma
Purpose: This study aimed to assess the effect of an external yellow-tinted filter (KIROS 1– 400 lens) on visual function in patients with pre-perimetric glaucoma (PPG) and early primary open-angle glaucoma (POAG). The primary outcomes were contrast sensitivity (CS) and visual field (VF) indices assessed using standard automated perimetry (SAP). Methods: This comparative observational, within-subject study included 30 patients with PPG (30 eyes) and 50 with POAG (50 eyes) recruited from the Ophthalmology Department of the 401 General Military Hospital, Athens, between January and December 2022. CS was measured using the Pelli-Robson chart. VF indices, including mean deviation (MD), pattern standard deviation (PSD), visual field index (VFI), and Glaucoma Hemifield Test (GHT) classifications, were assessed with SAP with the 24– 2 SITA-standard strategy on the Humphrey Field Analyzer II 740. All testing was performed both with and without the yellow filter KIROS 1– 400 (Essilor International) in the same eyes. Results: The KIROS 1– 400 filter significantly enhanced CS in both PPG and POAG eyes, increasing the median logCS by 0.03. However, while statistically significant, this improvement may not be clinically meaningful. In contrast, no significant changes were observed in the VF indices (MD, PSD, and VFI) when the filter was applied. Analysis of GHT results revealed that the filter reduced borderline classifications and showed high precision (0.733) and recall (0.846) for “outside normal limits” classifications. However, the agreement between the filtered and unfiltered GHT results was fair. Conclusion: The KIROS 1– 400 filter significantly enhanced CS in patients with PPG and POAG without notable effects on the VF indices. However, caution is advised when interpreting GHT results obtained with yellow-tinted filters. Further studies are recommended to evaluate the filter’s long-term clinical benefits and its potential role in glaucoma management.
- Open Access
- 8 July 2024
- Published by Sciencedomain International in Ophthalmology Research: An International Journal
- Vol. 19 (4) , 22-31
Amplitude of Accommodation in Young Caucasian Adults in Greece
Objective: This study aims to determine the prevalence of accommodation insufficiency among young Caucasian adults in Greece. Methods: Accommodation amplitude was assessed using the minus to blur method (PRA). Results were compared against Donder's and Hofstetter's values. Participants were categorized into "normal," "borderline," and "insufficient" based on deviations from expected values. Results: Over 50% of participants exhibited accommodation insufficiency. Men had significantly lower rates of normal accommodation amplitude compared to women. Further research is required to explore the impact of refractive errors on accommodation issues. Conclusions: Accommodation insufficiency is a significant issue among young adults, necessitating further studies and the establishment of standardized measurement methods. Investigating the role of the ciliary muscle in accommodation is also recommended.
- 8 July 2024
- Published by Sciencedomain International in Ophthalmology Research: An International Journal
- Vol. 19 (4) , 22-31
Open AccessAmplitude of Accommodation in Young Caucasian Adults in Greece
Objective: This study aims to determine the prevalence of accommodation insufficiency among young Caucasian adults in Greece. Methods: Accommodation amplitude was assessed using the minus to blur method (PRA). Results were compared against Donder's and Hofstetter's values. Participants were categorized into "normal," "borderline," and "insufficient" based on deviations from expected values. Results: Over 50% of participants exhibited accommodation insufficiency. Men had significantly lower rates of normal accommodation amplitude compared to women. Further research is required to explore the impact of refractive errors on accommodation issues. Conclusions: Accommodation insufficiency is a significant issue among young adults, necessitating further studies and the establishment of standardized measurement methods. Investigating the role of the ciliary muscle in accommodation is also recommended.
- Open Access
- 22 March 2024
- Published by MDPI AG in Preprints.org
Amplitude of Accommodation in young Greek adults, 18 - 28 years old
Introduction: Accommodation is the ability of the eye to change its refractive power (by altering the curvature of the crystalline lens) with the aim of focusing on different distances. In modern times, close working distances require good accommodation to ensure quality work without vision problems. However, dysfunction in accommodation is not uncommon. Specifically, accommodation insufficiency is the most common dysfunction associated with accommodation that can be observed at any age. Accommodation insufficiency is characterized by the eye's inability to reach its maximum potential for accommodation (amplitude of accommodation) based on age, with many individuals experiencing deviations equal to or greater than 2 diopters (2D) from the theoretically normal range. Finally, measuring the amplitude of accommodation and near vision tests should be established in routine eye examinations, as life now involves a variety of different distances. Objective: To record the rates of accommodative insufficiency in young Caucasian adults. Methods: The method used was minus to blur, and the comparison charts were based on Donder's and Hofstetter's values. Depending on the result, they were categorized as "normal," which refers to deviations from zero to 1 diopter (1D) (due to the fact that minus lenses underestimate or are quite strict regarding the range of accommodation compared to other methods in free space (e.g., push-up); "borderline," which refers to deviations from 1.25D to 1.75D or 2D with at least one eye deviating by less than 1.75D; and "accommodation insufficiency," which refers to deviations greater than 2D from the expected values, as proposed in other studies. Results: The results show a significant percentage of accommodation insufficiency in these age groups, with the percentage exceeding 50%. Additionally, men had significantly lower rates of normal accommodation amplitude compared to women. Further research is needed to study the role of refractive errors in accommodation problems. Conclusions: In a broader context, accommodation insufficiency appears to be a significant issue in young age groups, and additional studies should be conducted to analyze the problem in depth and determine its prevalence. Furthermore, a universal system for measuring the range of accommodation should be established to obtain safer results. Additionally, it would be interesting to observe the role and contribution of the ciliary muscle in the accommodation process in young adults, as theoretically, the crystalline lens is almost transparent, the issue with adaptation primarily concerns the majority's inability of the ciliary muscle to function effectively.
- 22 March 2024
- Published by MDPI AG in Preprints.org
Open AccessAmplitude of Accommodation in young Greek adults, 18 - 28 years old
Introduction: Accommodation is the ability of the eye to change its refractive power (by altering the curvature of the crystalline lens) with the aim of focusing on different distances. In modern times, close working distances require good accommodation to ensure quality work without vision problems. However, dysfunction in accommodation is not uncommon. Specifically, accommodation insufficiency is the most common dysfunction associated with accommodation that can be observed at any age. Accommodation insufficiency is characterized by the eye's inability to reach its maximum potential for accommodation (amplitude of accommodation) based on age, with many individuals experiencing deviations equal to or greater than 2 diopters (2D) from the theoretically normal range. Finally, measuring the amplitude of accommodation and near vision tests should be established in routine eye examinations, as life now involves a variety of different distances. Objective: To record the rates of accommodative insufficiency in young Caucasian adults. Methods: The method used was minus to blur, and the comparison charts were based on Donder's and Hofstetter's values. Depending on the result, they were categorized as "normal," which refers to deviations from zero to 1 diopter (1D) (due to the fact that minus lenses underestimate or are quite strict regarding the range of accommodation compared to other methods in free space (e.g., push-up); "borderline," which refers to deviations from 1.25D to 1.75D or 2D with at least one eye deviating by less than 1.75D; and "accommodation insufficiency," which refers to deviations greater than 2D from the expected values, as proposed in other studies. Results: The results show a significant percentage of accommodation insufficiency in these age groups, with the percentage exceeding 50%. Additionally, men had significantly lower rates of normal accommodation amplitude compared to women. Further research is needed to study the role of refractive errors in accommodation problems. Conclusions: In a broader context, accommodation insufficiency appears to be a significant issue in young age groups, and additional studies should be conducted to analyze the problem in depth and determine its prevalence. Furthermore, a universal system for measuring the range of accommodation should be established to obtain safer results. Additionally, it would be interesting to observe the role and contribution of the ciliary muscle in the accommodation process in young adults, as theoretically, the crystalline lens is almost transparent, the issue with adaptation primarily concerns the majority's inability of the ciliary muscle to function effectively.
- 11 March 2023
- Published by Sciencedomain International in Ophthalmology Research: An International Journal
- Vol. 18 (2) , 30-37
Quantitative Measurements of Macular and Optic Nerve Head Blood Flow Parameters Following Cataract Surgery in Eye Department, Red Cross Tertiary General Hospital, Athens, Greece
Objective: To evaluate the effect of uncomplicated cataract surgery on macular and optic nerve head blood flow with Optical Coherence Tomography Angiography (OCT-A). Retinal vascular changes and macular vessel remodeling following cataract surgery is an area of interest, as the effect, cause and duration of such changes remain debatable. Setting: Eye Department, Red Cross Tertiary General Hospital, Athens, Greece. Methods: In this study, we recruited cataract surgery candidates who had regular post operative visits and underwent longitudinal OCT-A examinations before and after surgery. Results: Macular vessel density increased in the post operative visits both in the superficial (SCP) and deep capillary network (DCP) (PConclusions: OCT-A enables a quantitative analysis of blood flow by regular patient monitoring. In this study, we found that after cataract surgery, macular blood flow increased significantly. The reason for this could be attributed to post operative inflammatory process or vascular remodeling due to change in retinal metabolic demands.
- 11 March 2023
- Published by Sciencedomain International in Ophthalmology Research: An International Journal
- Vol. 18 (2) , 30-37
Quantitative Measurements of Macular and Optic Nerve Head Blood Flow Parameters Following Cataract Surgery in Eye Department, Red Cross Tertiary General Hospital, Athens, Greece
Objective: To evaluate the effect of uncomplicated cataract surgery on macular and optic nerve head blood flow with Optical Coherence Tomography Angiography (OCT-A). Retinal vascular changes and macular vessel remodeling following cataract surgery is an area of interest, as the effect, cause and duration of such changes remain debatable. Setting: Eye Department, Red Cross Tertiary General Hospital, Athens, Greece. Methods: In this study, we recruited cataract surgery candidates who had regular post operative visits and underwent longitudinal OCT-A examinations before and after surgery. Results: Macular vessel density increased in the post operative visits both in the superficial (SCP) and deep capillary network (DCP) (PConclusions: OCT-A enables a quantitative analysis of blood flow by regular patient monitoring. In this study, we found that after cataract surgery, macular blood flow increased significantly. The reason for this could be attributed to post operative inflammatory process or vascular remodeling due to change in retinal metabolic demands.
- 4 May 2022
- Published by Sciencedomain International in Ophthalmology Research: An International Journal
- p. 26-35
The Effect of Monochromatic Aberrations of the Cornea on Contrast Sensitivity under Photopic and Mesopic Conditions
Purpose: Vision is one of the most important senses. The first stage of vision is the creation of the observed object’s image on the retina. The quality of the retinal image is affected by several factors, such as diffraction, sampling on the retina, chromatic aberration, scattering and higher order aberrations. The measurement of the quality is achieved both with subjective (visual acuity, contrast sensitivity) and objective methods (PSF, MTF, Strehl ratio, RMS). The purpose of this project is the measurement of higher order aberrations of the anterior corneal surface (with a Placido corneal topographer) and of the contrast sensitivity (with a Pelli Robson optotype). Then, we will try to find if there is a correlation between them. Methods and Materials: 20 persons participated in this survey, divided in two groups of 10 persons each. The first group (group 1) included subjects up to 39 years old and the second group (group 2) from 40 years and up. The participants didn’t have any pathological problems, except lower order refractive errors. Both eyes of each individual were included in the procedure. First, the higher order aberrations of the anterior corneal surface were measured, with the implementation of a Placido corneal topographer. This was followed by a measurement of the contrast sensitivity. The whole procedure took place under two lighting conditions, both photopic and mesopic. The examination presentation of the higher order aberrations is performed with the use of Zernike polynomials. Results: The results of the measuring procedure showed that for the first group, under photopic conditions (luminance 32.70 cd/m2) the mean value (± standard deviation) for the higher order aberrations RMS and decimal logarithm contrast sensitivity was 0.073 ± 0.018μm and 1.54 ± 0,16 (contrast 2.88 ± 1.24%) respectively. For the second group the corresponding values were 0.080 ± 0.036μm and 1.59 ± 0.16 (contrast 2.57 ± 1.24%). Accordingly, under mesopic conditions (luminance 1.14 cd/m2) the values for the first group were 0.252 ± 0.064 μm and 1.27 ± 0.15 (contrast 5.37 ± 2.06%), while for the second were 0.253 ± 0.069μm and 1.32 ± 0.12 (contrast 4.79 ± 1.35%). Spherical aberration and coma (horizontal and vertical) were also measured for both groups under photopic and mesopic conditions. The results showed that for the first group, under photopic conditions, RMS for coma and spherical aberration is 0.033 ± 0.014 μm and 0.022 ± 0.011 μm respectively, while for the second group 0.041 ± 0.027 μm and 0.024 ± 0.008 μm. Under mesopic conditions, the relevant results are 0.139 ± 0.065 μm and 0.124 ± 0.035μm for the first group and 0.149 ± 0.066 μm and 0.107 ± 0.038 μm for the second group. Finally, we should mention here that the equivalent defocus error corresponding to the higher order aberration RMS was estimated. The results for all the participants (without age separation), are 0.23 ± 0.09D (photopic conditions) and 0.28 ± 0.07D (mesopic conditions). Conclusions: From the statistical analysis of the results we conclude that there exists a symmetry between left and right eyes regarding higher order aberrations. Furthermore, it seems that age is not a significant factor for differences on the magnitude of higher order aberrations both under photopic and mesopic conditions as well. Similar conclusions are also reached for the contrast sensitivity measurements. In addition, we have observed that a correlation exists between the higher order aberrations of the anterior corneal surface and the contrast sensitivity, for both photopic and mesopic conditions. Correlation also exists between coma and contrast only under photopic conditions. But there is no significant correlation between spherical aberration and contrast. The age difference of these two groups has not an effect on the results. Finally, the equivalent defocus is too small, both for photopic and mesopic conditions and between each other, in order to be clinically significant.
- 4 May 2022
- Published by Sciencedomain International in Ophthalmology Research: An International Journal
- p. 26-35
The Effect of Monochromatic Aberrations of the Cornea on Contrast Sensitivity under Photopic and Mesopic Conditions
Purpose: Vision is one of the most important senses. The first stage of vision is the creation of the observed object’s image on the retina. The quality of the retinal image is affected by several factors, such as diffraction, sampling on the retina, chromatic aberration, scattering and higher order aberrations. The measurement of the quality is achieved both with subjective (visual acuity, contrast sensitivity) and objective methods (PSF, MTF, Strehl ratio, RMS). The purpose of this project is the measurement of higher order aberrations of the anterior corneal surface (with a Placido corneal topographer) and of the contrast sensitivity (with a Pelli Robson optotype). Then, we will try to find if there is a correlation between them. Methods and Materials: 20 persons participated in this survey, divided in two groups of 10 persons each. The first group (group 1) included subjects up to 39 years old and the second group (group 2) from 40 years and up. The participants didn’t have any pathological problems, except lower order refractive errors. Both eyes of each individual were included in the procedure. First, the higher order aberrations of the anterior corneal surface were measured, with the implementation of a Placido corneal topographer. This was followed by a measurement of the contrast sensitivity. The whole procedure took place under two lighting conditions, both photopic and mesopic. The examination presentation of the higher order aberrations is performed with the use of Zernike polynomials. Results: The results of the measuring procedure showed that for the first group, under photopic conditions (luminance 32.70 cd/m2) the mean value (± standard deviation) for the higher order aberrations RMS and decimal logarithm contrast sensitivity was 0.073 ± 0.018μm and 1.54 ± 0,16 (contrast 2.88 ± 1.24%) respectively. For the second group the corresponding values were 0.080 ± 0.036μm and 1.59 ± 0.16 (contrast 2.57 ± 1.24%). Accordingly, under mesopic conditions (luminance 1.14 cd/m2) the values for the first group were 0.252 ± 0.064 μm and 1.27 ± 0.15 (contrast 5.37 ± 2.06%), while for the second were 0.253 ± 0.069μm and 1.32 ± 0.12 (contrast 4.79 ± 1.35%). Spherical aberration and coma (horizontal and vertical) were also measured for both groups under photopic and mesopic conditions. The results showed that for the first group, under photopic conditions, RMS for coma and spherical aberration is 0.033 ± 0.014 μm and 0.022 ± 0.011 μm respectively, while for the second group 0.041 ± 0.027 μm and 0.024 ± 0.008 μm. Under mesopic conditions, the relevant results are 0.139 ± 0.065 μm and 0.124 ± 0.035μm for the first group and 0.149 ± 0.066 μm and 0.107 ± 0.038 μm for the second group. Finally, we should mention here that the equivalent defocus error corresponding to the higher order aberration RMS was estimated. The results for all the participants (without age separation), are 0.23 ± 0.09D (photopic conditions) and 0.28 ± 0.07D (mesopic conditions). Conclusions: From the statistical analysis of the results we conclude that there exists a symmetry between left and right eyes regarding higher order aberrations. Furthermore, it seems that age is not a significant factor for differences on the magnitude of higher order aberrations both under photopic and mesopic conditions as well. Similar conclusions are also reached for the contrast sensitivity measurements. In addition, we have observed that a correlation exists between the higher order aberrations of the anterior corneal surface and the contrast sensitivity, for both photopic and mesopic conditions. Correlation also exists between coma and contrast only under photopic conditions. But there is no significant correlation between spherical aberration and contrast. The age difference of these two groups has not an effect on the results. Finally, the equivalent defocus is too small, both for photopic and mesopic conditions and between each other, in order to be clinically significant.
- 19 December 2020
- Published by Sciencedomain International in Ophthalmology Research: An International Journal
- p. 33-40
Comparison of Axial Length Measurements with the Use of Optical Biometry (IOL Master 700) and Ultrasound Biometry (A‐scan 550 Sonomed)
Purpose: To compare measurements of axial length obtained with A-scan and IOL Master. The study was design to collect the axial length values resulting from the application of both methods on the same eye (R.E.) and then to compare them. Methodology Place and Duration of Study: 50 healthy patients selected randomly after visiting the clinic for daily routine examination. at the general hospital of Athens “Korgialenio – Benakio” were invited to participate in the study. The study took place in collaboration of University of West Attica Dept Biomedical Science Course Optics & Optometry with the general hospital of Athens “Korgialenio – Benakio”. Axial length measurements were obtained both by contact ultrasound (A‐scan 550 Sonomed, Lake Success, NY, USA) and by non‐contact laser interferometry (IOL Master 700 SWEPT Source Biometry). Two sets of measurements were repeated by a single examiner for each method. Results: A total of 50 eyes in 50 patients were evaluated. All participants volunteer to participate in this study. Estimates of axial length obtained with the two techniques were highly correlated. Axial lengths obtained with the contact method (mean 24.23mm, SD 1.64mm) were lower than those obtained with the non‐contact method (mean 23.29mm, SD 1.59mm) and the difference was not statistically significant (p = 0.150). The coefficient of variation was lower with non‐contact laser interferometry (6.58%) than with the ultrasound technique (6.76%). Conclusion: Similar estimates of axial length are obtained using contact and non‐contact techniques, with the latter producing higher measurements results than the former. The A-scan and the non‐contact laser interferometry device (IOL Master 700) provide both reproducible results with similar the accuracy of measurements of axial length in the clinical setting.
- 19 December 2020
- Published by Sciencedomain International in Ophthalmology Research: An International Journal
- p. 33-40
Comparison of Axial Length Measurements with the Use of Optical Biometry (IOL Master 700) and Ultrasound Biometry (A‐scan 550 Sonomed)
Purpose: To compare measurements of axial length obtained with A-scan and IOL Master. The study was design to collect the axial length values resulting from the application of both methods on the same eye (R.E.) and then to compare them. Methodology Place and Duration of Study: 50 healthy patients selected randomly after visiting the clinic for daily routine examination. at the general hospital of Athens “Korgialenio – Benakio” were invited to participate in the study. The study took place in collaboration of University of West Attica Dept Biomedical Science Course Optics & Optometry with the general hospital of Athens “Korgialenio – Benakio”. Axial length measurements were obtained both by contact ultrasound (A‐scan 550 Sonomed, Lake Success, NY, USA) and by non‐contact laser interferometry (IOL Master 700 SWEPT Source Biometry). Two sets of measurements were repeated by a single examiner for each method. Results: A total of 50 eyes in 50 patients were evaluated. All participants volunteer to participate in this study. Estimates of axial length obtained with the two techniques were highly correlated. Axial lengths obtained with the contact method (mean 24.23mm, SD 1.64mm) were lower than those obtained with the non‐contact method (mean 23.29mm, SD 1.59mm) and the difference was not statistically significant (p = 0.150). The coefficient of variation was lower with non‐contact laser interferometry (6.58%) than with the ultrasound technique (6.76%). Conclusion: Similar estimates of axial length are obtained using contact and non‐contact techniques, with the latter producing higher measurements results than the former. The A-scan and the non‐contact laser interferometry device (IOL Master 700) provide both reproducible results with similar the accuracy of measurements of axial length in the clinical setting.
- Open Access
- 2 October 2020
- Published by Sciencedomain International in Ophthalmology Research: An International Journal
- p. 1-9
Comparison of Central Corneal Thickness Measurements between Angiovue Optical Coherence Tomography, Ultrasound Pachymetry and Ocular Biometry
Purpose: To compare central corneal thickness (CCT) measurements and their reproducibility when taken by Ultrasound Pachymetry, Ocular Biometry and Angiovue Optical Coherence Tomography (OCT). Methods: Twenty-five healthy volunteers were recruited creating a sample size of 50 eyes. All subjects had pachymetric measurements by Ultrasound pachymetry (PachPen Handheld Pachymeter, Keeler Instruments Inc), Ocular biometry (IOL Master 700 Swept Source Biometry, Zeiss) and Angiovue Optical Coherence Tomography (Optovue Avanti RTVue XR Angiovue). The measurements of central corneal thickness for the three devices were taken by the same examiner twice for more accuracy. Results: The average measurements of central corneal thickness by Ultrasound pachymetry (PachPen Handheld Pachymeter, Keeler Instruments Inc), Ocular biometry (IOL Master 700 Swept Source Biometry, Zeiss) and Angiovue Optical Coherence Tomography (Optovue Avanti RTVue XR Angiovue) were 547.26 μm, 551.36 μm, and 536.42 μm, respectively. The mean standard deviation (SD) of repeated measurements by Ocular biometry was 48.87 μm, which was greater than the mean SD of 44.24 μm and 40.35 μm (P < 0.001) by ultrasound pachymetry and Angiovue optical coherence tomography, respectively. There were statistically significant differences in the measurement results among the 3 methods (Ultrasound pachymetry vs. Ocular biometry P = 0.019; Ultrasound pachymetry vs. Angiovue Optical Coherence Tomography; P < 0.001; Ocular biometry vs. Angiovue Optical Coherence Tomography P < 0.001). There was a significant linear correlation between the Ultrasound pachymetry and Ocular biometry (r = 0.945, PConclusion: Central corneal thickness readings were comparable between PachPen Handheld Pachymeter, IOL Master 700 Biometry and Angiovue Optical Coherence Tomography; Angiovue optical coherence tomography gave significantly smaller values. The measurements of the 3 methods showed significant linear correlations with one another. All methods provided acceptable repeatability of measurements.
- 2 October 2020
- Published by Sciencedomain International in Ophthalmology Research: An International Journal
- p. 1-9
Open AccessComparison of Central Corneal Thickness Measurements between Angiovue Optical Coherence Tomography, Ultrasound Pachymetry and Ocular Biometry
Purpose: To compare central corneal thickness (CCT) measurements and their reproducibility when taken by Ultrasound Pachymetry, Ocular Biometry and Angiovue Optical Coherence Tomography (OCT). Methods: Twenty-five healthy volunteers were recruited creating a sample size of 50 eyes. All subjects had pachymetric measurements by Ultrasound pachymetry (PachPen Handheld Pachymeter, Keeler Instruments Inc), Ocular biometry (IOL Master 700 Swept Source Biometry, Zeiss) and Angiovue Optical Coherence Tomography (Optovue Avanti RTVue XR Angiovue). The measurements of central corneal thickness for the three devices were taken by the same examiner twice for more accuracy. Results: The average measurements of central corneal thickness by Ultrasound pachymetry (PachPen Handheld Pachymeter, Keeler Instruments Inc), Ocular biometry (IOL Master 700 Swept Source Biometry, Zeiss) and Angiovue Optical Coherence Tomography (Optovue Avanti RTVue XR Angiovue) were 547.26 μm, 551.36 μm, and 536.42 μm, respectively. The mean standard deviation (SD) of repeated measurements by Ocular biometry was 48.87 μm, which was greater than the mean SD of 44.24 μm and 40.35 μm (P < 0.001) by ultrasound pachymetry and Angiovue optical coherence tomography, respectively. There were statistically significant differences in the measurement results among the 3 methods (Ultrasound pachymetry vs. Ocular biometry P = 0.019; Ultrasound pachymetry vs. Angiovue Optical Coherence Tomography; P < 0.001; Ocular biometry vs. Angiovue Optical Coherence Tomography P < 0.001). There was a significant linear correlation between the Ultrasound pachymetry and Ocular biometry (r = 0.945, PConclusion: Central corneal thickness readings were comparable between PachPen Handheld Pachymeter, IOL Master 700 Biometry and Angiovue Optical Coherence Tomography; Angiovue optical coherence tomography gave significantly smaller values. The measurements of the 3 methods showed significant linear correlations with one another. All methods provided acceptable repeatability of measurements.
- 21 August 2020
- Published by Sciencedomain International in Ophthalmology Research: An International Journal
- p. 1-12
Comparative Study of Anterior Chamber Angle and Depth Recorded with Pentacam and AS-OCT SD “Spectralis”
Aims: To compare the anterior chamber angle values recorded by Pentacam and AS-OCT SD “Spectralis” (Heidelberg Engineering) and present the correlation between the two devices. Sample and Study Design: A total of 50 patients were examined at the Private Ophthalmology Clinic O.M.M.A. Ophthalmological Institute. All participants volunteer to participate in this study where the data was kept anonymous. Patients aged 18-45 years without a pathological history were selected. All of them were emmetropes or with ametropia ranged ±0.75 D. There was no separation between hyperopic, myopic or emmetropic patients. Place and Duration of Study: University of West Attica Dept Biomedical Science Course Optics & Optometry in collaboration with Private Ophthalmology Clinic O.M.M.A. during the period between January 2019 to October 2019. Methodology: In this study, two basic structures of the eye are measured with the help of two devices of different principle of operation. Specifically, the study of the angle of the anterior chamber (ACA) as well as the depth of the chamber (ACD). The two devises are compared. Results: The ACA for both devices had mean difference of -2,004° for the R.E. while the mean difference for L.E. was 1,986°. Pentacam arithmetic mean ACA (R.E.) was 37,638 ± 2,98° and AS-OCT “Spectralis” 35,766 ± 2,90° with Correlation coefficient 0,7063 (P
- 21 August 2020
- Published by Sciencedomain International in Ophthalmology Research: An International Journal
- p. 1-12
Comparative Study of Anterior Chamber Angle and Depth Recorded with Pentacam and AS-OCT SD “Spectralis”
Aims: To compare the anterior chamber angle values recorded by Pentacam and AS-OCT SD “Spectralis” (Heidelberg Engineering) and present the correlation between the two devices. Sample and Study Design: A total of 50 patients were examined at the Private Ophthalmology Clinic O.M.M.A. Ophthalmological Institute. All participants volunteer to participate in this study where the data was kept anonymous. Patients aged 18-45 years without a pathological history were selected. All of them were emmetropes or with ametropia ranged ±0.75 D. There was no separation between hyperopic, myopic or emmetropic patients. Place and Duration of Study: University of West Attica Dept Biomedical Science Course Optics & Optometry in collaboration with Private Ophthalmology Clinic O.M.M.A. during the period between January 2019 to October 2019. Methodology: In this study, two basic structures of the eye are measured with the help of two devices of different principle of operation. Specifically, the study of the angle of the anterior chamber (ACA) as well as the depth of the chamber (ACD). The two devises are compared. Results: The ACA for both devices had mean difference of -2,004° for the R.E. while the mean difference for L.E. was 1,986°. Pentacam arithmetic mean ACA (R.E.) was 37,638 ± 2,98° and AS-OCT “Spectralis” 35,766 ± 2,90° with Correlation coefficient 0,7063 (P
- 16 July 2020
- Published by Sciencedomain International in Ophthalmology Research: An International Journal
- p. 7-33
Comparison between OrbscanIIz, Pentacam, Ultrasound Pachymetry (Tomey SP-100) at Different Stages of Keratoconus
Aims: To compare results of OrbscanIIz and Pentacam and Ultrasound pachymetry at different stages of keratoconus on corneal thickness. Sample and Study Design: 94 keratoconic patients participated in the study, of which 52 were men and 42 women. Keratoconus patients were measured with OrbscanIIz, Pentacam and Ultrasound pachymetry in pre-operation examinations for corneal collagen cross-linking. The patients belong to different keratoconus stages. Place and Duration of Study: University of West Attica Dept Biomedical Sciensce Course Optics & Optometry in collaboration with Athens “Ophthalmologico” Clinic during the period between October 2017 to January 2019. Methodology: Corneal Pachymetry maps correlation of three types of corneal pachymeters OrbscanIIz, Pentacam and Ultrasound pachymetry (Tomey SP-100 Pachymeter). The measurements of the thinnest point of the cornea from each patient were collected at different stages of keratoconus and compared. Results: A sample of 188 eyes were measured at different stages of keratoconus and compared for the thinnest corneal thickness with three different measurement systems, OrbscanIIz ,Pentacam and Ultrasound pachymetry. At sublinical stage Orbscan-Pentacam had Correlation coefficient r=0,7971, Orbscan-Ultrasound r=0,7483 and Pentacam-Ultrasound r=0,9442. At 1st stage Orbscan-Pentacam had Correlation coefficient r=0,8913, Orbscan-Ultrasound r=0,8151 and Pentacam-Ultrasound r=0,8151. At 2nd stage Orbscan-Pentacam had Correlation coefficient r=0,9339, Orbscan-Ultrasound r=0,8819 and Pentacam-Ultrasound r=0,9633. For 3rd stage Orbscan-Pentacam had Correlation coefficient r=0,8317, Orbscan-Ultrasound r=0,8457 and Pentacam-Ultrasound r=0,9633. For 4th stage Orbscan-Pentacam had Correlation coefficient r=-0,4655, Orbscan-Ultrasound r=0,3089 and Pentacam-Ultrasound r=0,9633. In Iatrogenic keratoectasiaafter refractive surgery Orbscan-Pentacam had Correlation coefficient r=0,9327, Orbscan-Ultrasound r=0,3089 and Pentacam-Ultrasound r=0,9859. Conclusion: Statistical differences between OrbscanIIz, Pentacam and Ultrasound pachymetry were found for corneal thickness in all stages of keratoconus for the thinnest point measured. Orbscan-Pentacam have statistical significant differences but weak to moderate correlation. Orbscan-Ultasound have also statistical significant differences their correlation is very weak, while Pentacam-Ultrasound have statistical significant differences smaller as the previous but their correlation is very strong at all stages of keratoconus.
- 16 July 2020
- Published by Sciencedomain International in Ophthalmology Research: An International Journal
- p. 7-33
Comparison between OrbscanIIz, Pentacam, Ultrasound Pachymetry (Tomey SP-100) at Different Stages of Keratoconus
Aims: To compare results of OrbscanIIz and Pentacam and Ultrasound pachymetry at different stages of keratoconus on corneal thickness. Sample and Study Design: 94 keratoconic patients participated in the study, of which 52 were men and 42 women. Keratoconus patients were measured with OrbscanIIz, Pentacam and Ultrasound pachymetry in pre-operation examinations for corneal collagen cross-linking. The patients belong to different keratoconus stages. Place and Duration of Study: University of West Attica Dept Biomedical Sciensce Course Optics & Optometry in collaboration with Athens “Ophthalmologico” Clinic during the period between October 2017 to January 2019. Methodology: Corneal Pachymetry maps correlation of three types of corneal pachymeters OrbscanIIz, Pentacam and Ultrasound pachymetry (Tomey SP-100 Pachymeter). The measurements of the thinnest point of the cornea from each patient were collected at different stages of keratoconus and compared. Results: A sample of 188 eyes were measured at different stages of keratoconus and compared for the thinnest corneal thickness with three different measurement systems, OrbscanIIz ,Pentacam and Ultrasound pachymetry. At sublinical stage Orbscan-Pentacam had Correlation coefficient r=0,7971, Orbscan-Ultrasound r=0,7483 and Pentacam-Ultrasound r=0,9442. At 1st stage Orbscan-Pentacam had Correlation coefficient r=0,8913, Orbscan-Ultrasound r=0,8151 and Pentacam-Ultrasound r=0,8151. At 2nd stage Orbscan-Pentacam had Correlation coefficient r=0,9339, Orbscan-Ultrasound r=0,8819 and Pentacam-Ultrasound r=0,9633. For 3rd stage Orbscan-Pentacam had Correlation coefficient r=0,8317, Orbscan-Ultrasound r=0,8457 and Pentacam-Ultrasound r=0,9633. For 4th stage Orbscan-Pentacam had Correlation coefficient r=-0,4655, Orbscan-Ultrasound r=0,3089 and Pentacam-Ultrasound r=0,9633. In Iatrogenic keratoectasiaafter refractive surgery Orbscan-Pentacam had Correlation coefficient r=0,9327, Orbscan-Ultrasound r=0,3089 and Pentacam-Ultrasound r=0,9859. Conclusion: Statistical differences between OrbscanIIz, Pentacam and Ultrasound pachymetry were found for corneal thickness in all stages of keratoconus for the thinnest point measured. Orbscan-Pentacam have statistical significant differences but weak to moderate correlation. Orbscan-Ultasound have also statistical significant differences their correlation is very weak, while Pentacam-Ultrasound have statistical significant differences smaller as the previous but their correlation is very strong at all stages of keratoconus.
- 11 July 2020
- Published by Sciencedomain International in Ophthalmology Research: An International Journal
- p. 30-40
Comparison for Kmean and Astigmatism for Orbscan IIz and Pentacam at Different Stages of Keratoconus - A Clinical Study
Aims: To compare results of Orbscan IIz and Pentacam at different stages of keratoconus on Kmean and Astigmatism. Sample and Study Design: 94 keratoconus patients were included in the study, of which 52 were men and 42 women. Keratoconus patients were screened with Orbscan IIz and Pentacam before undergoing corneal collagen cross-linking. The patients were distributed according to different keratoconus stages. Place and Duration of Study: University of West Attica Dept Biomedical Sciensce Course Optics & Optometry in collaboration with Athens “Ophthalmiatrio” Clinic during the period between October 2017 to January 2019. Methodology: Topographic maps correlation of two types of corneal topographers Orbscan IIz and Pentacam. The Kmean values and the Astigmatism presented at different stages of keratoconus were compared. Results: A Sample of 188 eyes were measured having, 20 eyes (10.6%) with subclinical keratoconus, the correlation coefficient r for Kmean values between Orbscan IIz and Pentacam was 0.9758 (P
- 11 July 2020
- Published by Sciencedomain International in Ophthalmology Research: An International Journal
- p. 30-40
Comparison for Kmean and Astigmatism for Orbscan IIz and Pentacam at Different Stages of Keratoconus - A Clinical Study
Aims: To compare results of Orbscan IIz and Pentacam at different stages of keratoconus on Kmean and Astigmatism. Sample and Study Design: 94 keratoconus patients were included in the study, of which 52 were men and 42 women. Keratoconus patients were screened with Orbscan IIz and Pentacam before undergoing corneal collagen cross-linking. The patients were distributed according to different keratoconus stages. Place and Duration of Study: University of West Attica Dept Biomedical Sciensce Course Optics & Optometry in collaboration with Athens “Ophthalmiatrio” Clinic during the period between October 2017 to January 2019. Methodology: Topographic maps correlation of two types of corneal topographers Orbscan IIz and Pentacam. The Kmean values and the Astigmatism presented at different stages of keratoconus were compared. Results: A Sample of 188 eyes were measured having, 20 eyes (10.6%) with subclinical keratoconus, the correlation coefficient r for Kmean values between Orbscan IIz and Pentacam was 0.9758 (P