Hongli Ye
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hongli Ye has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
- Wen-You Li
Nankai University
5 shared publications Xi-Wen He
State Key Laboratory of Medicinal Chemical Biology, Tianjin Key Laboratory of Biosensing and Molecular Recognition, Research Center for Analytical Sciences, College of Chemistry, Nankai University, Tianjin 300071, China
5 shared publicationsYu-Kui Zhang
State Key Laboratory of Medicinal Chemical Biology, Tianjin Key Laboratory of Biosensing and Molecular Recognition, Research Center for Analytical Sciences, College of Chemistry, Nankai University, Tianjin 300071, China; National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
5 shared publicationsLiangliang Tian
Fishery Products Quality Inspection and Test Centre (Shanghai), Ministry of Agriculture and Rural Affairs of China, East China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Shanghai, China
4 shared publications- Cui Zhang
Institute of New Catalytic Materials Science and MOE Key Laboratory of Advanced Energy Materials Chemistry, School of Materials Science and Engineering, National Institute of Advanced Materials, Nankai University, Tianjin 300350, China
3 shared publications Dongmei Huang
3 shared publications
Latest Publications
- Open Access
Dual-Mode Detection of Perfluorooctanoic Acid Using Up-Conversion Fluorescent Silicon Quantum Dots–Molecularly Imprinted Polymers and Smartphone Sensing
Perfluorooctanoic acid (PFOA) is a persistent and bioaccumulative hazardous pollutant, presenting substantial threats to the environment and human health. The dual-mode, portable, sensitive, low-background, and cost-effective detection methods for PFOA were developed by integrating up-conversion fluorescent silicon quantum dot–molecularly imprinted polymer (MIPs) with a smartphone-based sensing system. The interaction between PFOA and MIPs resulted in a fluorescence quenching with a range of 2–20 µmol/L and a limit of detection (LOD) of 37.5 nmol/L for the low-background up-conversion fluorescence detection of PFOA, whereas the portable smartphone sensing platform enabled the detection of PFOA with a linear range of 0–5 µmol/L and a LOD of 73.9 nmol/L. Furthermore, the established methods were successfully applied to the detection of PFOA in environmental waters and food samples. This study provides the dual-mode, portable, novel, practical and low-background approaches for the detection of PFOA in the environment and food products.
Open AccessDual-Mode Detection of Perfluorooctanoic Acid Using Up-Conversion Fluorescent Silicon Quantum Dots–Molecularly Imprinted Polymers and Smartphone Sensing
Perfluorooctanoic acid (PFOA) is a persistent and bioaccumulative hazardous pollutant, presenting substantial threats to the environment and human health. The dual-mode, portable, sensitive, low-background, and cost-effective detection methods for PFOA were developed by integrating up-conversion fluorescent silicon quantum dot–molecularly imprinted polymer (MIPs) with a smartphone-based sensing system. The interaction between PFOA and MIPs resulted in a fluorescence quenching with a range of 2–20 µmol/L and a limit of detection (LOD) of 37.5 nmol/L for the low-background up-conversion fluorescence detection of PFOA, whereas the portable smartphone sensing platform enabled the detection of PFOA with a linear range of 0–5 µmol/L and a LOD of 73.9 nmol/L. Furthermore, the established methods were successfully applied to the detection of PFOA in environmental waters and food samples. This study provides the dual-mode, portable, novel, practical and low-background approaches for the detection of PFOA in the environment and food products.
- 15 September 2024
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 325, 125135
A smartphone sensing fluorescent detection of mercury ion based on silicon quantum dots in environment water
- 15 September 2024
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 325, 125135
A smartphone sensing fluorescent detection of mercury ion based on silicon quantum dots in environment water
- Open Access
Fabrication of Carbon Nanotubes Derived from Waste Tire Pyrolytic Carbon and Their Application in the Dehydrogenation of Methylcyclohexane to Produce Hydrogen
The accumulation of waste tires has resulted in very urgent environmental problems. Pyrolysis has been regarded as a green eco-friendly technology to deal with waste tires, and it is vital to make use of the pyrolysis carbon. Herein, we propose a new way to utilize pyrolysis carbon, to prepare carbon nanotubes with the help of ferrocene. The optimal preparation processes were determined by optimizing the parameters including the solvent, temperature, time, etc. The results of scanning electron microscopy and transmission electron microscopy evidenced the successful formation of carbon nanotubes. Meanwhile, the Brunauer–Emmett–Teller (BET) method and N2-adsorption showed that the yielded carbon nanotubes featured a large surface area and abundant pore structure in comparison with the pyrolytic carbon. Finally, the as-prepared carbon nanotubes were applied as the supports for Pt-based catalysts for the dehydrogenation of methylcyclohexane to produce hydrogen. The results showed that the Pt/carbon-nanotubes catalyst exhibited the highest conversion of methylcyclohexane (28.6%), stability, and hydrogen evolution rate (336.9 mmol/gPt/min) compared to the resulting Pt/commercial-activated-carbon (13.6% and 160.2 mmol/gPt/min) and Pt/pyrolytic-carbon catalysts (0.19% and 2.23 mmol/gPt/min).
Open AccessFabrication of Carbon Nanotubes Derived from Waste Tire Pyrolytic Carbon and Their Application in the Dehydrogenation of Methylcyclohexane to Produce Hydrogen
The accumulation of waste tires has resulted in very urgent environmental problems. Pyrolysis has been regarded as a green eco-friendly technology to deal with waste tires, and it is vital to make use of the pyrolysis carbon. Herein, we propose a new way to utilize pyrolysis carbon, to prepare carbon nanotubes with the help of ferrocene. The optimal preparation processes were determined by optimizing the parameters including the solvent, temperature, time, etc. The results of scanning electron microscopy and transmission electron microscopy evidenced the successful formation of carbon nanotubes. Meanwhile, the Brunauer–Emmett–Teller (BET) method and N2-adsorption showed that the yielded carbon nanotubes featured a large surface area and abundant pore structure in comparison with the pyrolytic carbon. Finally, the as-prepared carbon nanotubes were applied as the supports for Pt-based catalysts for the dehydrogenation of methylcyclohexane to produce hydrogen. The results showed that the Pt/carbon-nanotubes catalyst exhibited the highest conversion of methylcyclohexane (28.6%), stability, and hydrogen evolution rate (336.9 mmol/gPt/min) compared to the resulting Pt/commercial-activated-carbon (13.6% and 160.2 mmol/gPt/min) and Pt/pyrolytic-carbon catalysts (0.19% and 2.23 mmol/gPt/min).
- Open Access
- 17 October 2022
- Published by MDPI AG in Antibiotics
- Vol. 11 (10) , 1427
Highly Sensitive Determination of Antibiotic Residues in Aquatic Products by High-Performance Liquid Chromatography–Tandem Mass Spectrometry
Antibiotic drug residues are crucial to ensure food safety and minimize risk to human health. Herein, a sensitive high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) method was developed and validated for the determination of antibiotic residues (mainly amphenicols) consisting of chloramphenicol (CAP), thiamphenicol (TAP), florfenicol (FF), and florfenicol amine (FFA) in aquatic products. Amphenicols were well separated on a Kinetex F5 (100 mm × 3.0 mm, 2.6 µm) chromatographic column with the mobile phases of 1 mM ammonium acetate aqueous solution and methanol solution and measured after positive and negative electrospray ionizations using four internal standards. To our knowledge, it was the first time to report the good performance of F5 column and four internal standards for the determination of amphenicols. The established method featured a good linear relationship between chromatographic peak area ratios and the concentrations of amphenicols (R2 > 0.992), a wide and low detection matrix-based range of 0.01–5 μg/L, a low detection limit of 0.01 μg/kg, etc. The spiked assays evidenced the accuracy and reliability of the developed method with the recoveries between 84.0 and 105%, the intraday relative standard deviations (RSDs) over the range of 0.769–13.7%, and the interday RSDs over the range of 0.582–13.3%. Finally, the proposed method was applied to investigate amphenicol residues in various aquatic products, including fish, shrimp, crab, shellfish, and other aquatic species.
- 17 October 2022
- Published by MDPI AG in Antibiotics
- Vol. 11 (10) , 1427
Open AccessHighly Sensitive Determination of Antibiotic Residues in Aquatic Products by High-Performance Liquid Chromatography–Tandem Mass Spectrometry
Antibiotic drug residues are crucial to ensure food safety and minimize risk to human health. Herein, a sensitive high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) method was developed and validated for the determination of antibiotic residues (mainly amphenicols) consisting of chloramphenicol (CAP), thiamphenicol (TAP), florfenicol (FF), and florfenicol amine (FFA) in aquatic products. Amphenicols were well separated on a Kinetex F5 (100 mm × 3.0 mm, 2.6 µm) chromatographic column with the mobile phases of 1 mM ammonium acetate aqueous solution and methanol solution and measured after positive and negative electrospray ionizations using four internal standards. To our knowledge, it was the first time to report the good performance of F5 column and four internal standards for the determination of amphenicols. The established method featured a good linear relationship between chromatographic peak area ratios and the concentrations of amphenicols (R2 > 0.992), a wide and low detection matrix-based range of 0.01–5 μg/L, a low detection limit of 0.01 μg/kg, etc. The spiked assays evidenced the accuracy and reliability of the developed method with the recoveries between 84.0 and 105%, the intraday relative standard deviations (RSDs) over the range of 0.769–13.7%, and the interday RSDs over the range of 0.582–13.3%. Finally, the proposed method was applied to investigate amphenicol residues in various aquatic products, including fish, shrimp, crab, shellfish, and other aquatic species.
- Open Access
Simultaneous Determination of Tetrodotoxin in the Fresh and Heat-Processed Aquatic Products by High-Performance Liquid Chromatography–Tandem Mass Spectrometry
Tetrodotoxin (TTX) was simultaneously detected in the fresh and heat-processed aquatic products by high-performance liquid chromatography–tandem mass spectrometry method. The detection conditions were investigated, including the chromatography column and mobile phase. Based on the optimized parameters, a sensitive determination method of TTX was established. The proposed method featured the merits of a good linear relationship between signal and TTX concentration (R2 = 0.9998), a wide detection matrix-based range of 0.2–100 ng/g, and a low detection limit of 0.2 ng/g, etc. The spiked assays evidenced its accuracy and reliability with recoveries of 90.5–107.2%. Finally, the developed method was simultaneously successfully applied in the determination of TTX in various fresh and heat-processed aquatic products.
Open AccessSimultaneous Determination of Tetrodotoxin in the Fresh and Heat-Processed Aquatic Products by High-Performance Liquid Chromatography–Tandem Mass Spectrometry
Tetrodotoxin (TTX) was simultaneously detected in the fresh and heat-processed aquatic products by high-performance liquid chromatography–tandem mass spectrometry method. The detection conditions were investigated, including the chromatography column and mobile phase. Based on the optimized parameters, a sensitive determination method of TTX was established. The proposed method featured the merits of a good linear relationship between signal and TTX concentration (R2 = 0.9998), a wide detection matrix-based range of 0.2–100 ng/g, and a low detection limit of 0.2 ng/g, etc. The spiked assays evidenced its accuracy and reliability with recoveries of 90.5–107.2%. Finally, the developed method was simultaneously successfully applied in the determination of TTX in various fresh and heat-processed aquatic products.
- Open Access
Fabrication of Pt-Loaded Catalysts Supported on the Functionalized Pyrolytic Activated Carbon Derived from Waste Tires for the High Performance Dehydrogenation of Methylcyclohexane and Hydrogen Production
The pyrolytic activated carbon derived from waste tires (PTC) was functionalized to fabricate the high performance of Pt-based catalysts in the dehydrogenation of methylcyclohexane and hydrogen production. Structural characterizations evidenced that the modification partially influenced the surface area, the pore structure, and the oxygen-containing functional groups of the supports. The techniques of CO pulse, transmission electron microscopy, and hydrogen temperature-programmed reduction were utilized to investigate the dispersion degrees and particle sizes of the active component Pt, and its interaction with the various functionalized supports, respectively. The results manifested that Pt particles loaded on the functionalized PTC-S had the largest dispersion degree and the smallest size among those loaded on PTC and other functionalized PTC (i.e., PTC-K and PTC-NH). Finally, the Pt-based catalysts were successfully applied in the dehydrogenation reaction of methylcyclohexane to yield hydrogen. The results revealed that the Pt catalyst over the functional PTC-S support exhibited a more excellent conversion of methylcyclohexane (84.3%) and a higher hydrogen evolution rate (991.5 mmol/gPt/min) than the other resulting Pt-based catalysts.
Open AccessFabrication of Pt-Loaded Catalysts Supported on the Functionalized Pyrolytic Activated Carbon Derived from Waste Tires for the High Performance Dehydrogenation of Methylcyclohexane and Hydrogen Production
The pyrolytic activated carbon derived from waste tires (PTC) was functionalized to fabricate the high performance of Pt-based catalysts in the dehydrogenation of methylcyclohexane and hydrogen production. Structural characterizations evidenced that the modification partially influenced the surface area, the pore structure, and the oxygen-containing functional groups of the supports. The techniques of CO pulse, transmission electron microscopy, and hydrogen temperature-programmed reduction were utilized to investigate the dispersion degrees and particle sizes of the active component Pt, and its interaction with the various functionalized supports, respectively. The results manifested that Pt particles loaded on the functionalized PTC-S had the largest dispersion degree and the smallest size among those loaded on PTC and other functionalized PTC (i.e., PTC-K and PTC-NH). Finally, the Pt-based catalysts were successfully applied in the dehydrogenation reaction of methylcyclohexane to yield hydrogen. The results revealed that the Pt catalyst over the functional PTC-S support exhibited a more excellent conversion of methylcyclohexane (84.3%) and a higher hydrogen evolution rate (991.5 mmol/gPt/min) than the other resulting Pt-based catalysts.
- 1 February 2022
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 267 (Pt 1) , 120450
Two-photon-excited tumor cell fluorescence targeted imaging based on transferrin-functionalized silicon nanoparticles
- 1 February 2022
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 267 (Pt 1) , 120450
Two-photon-excited tumor cell fluorescence targeted imaging based on transferrin-functionalized silicon nanoparticles
- 29 January 2022
- Published by Springer Nature in Journal of Materials Science
- Vol. 57 (7) , 4738-4753
Fabrication of the water-soluble functionalized silicon nanoparticles for biomedical applications
- 29 January 2022
- Published by Springer Nature in Journal of Materials Science
- Vol. 57 (7) , 4738-4753
Fabrication of the water-soluble functionalized silicon nanoparticles for biomedical applications
- Open Access
- 10 January 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (2) , 213
“Switch-Off-On” Detection of Fe3+ and F− Ions Based on Fluorescence Silicon Nanoparticles and Their Application to Food Samples
An approach to the detection of F− ions in food samples was developed based on a “switch-off-on” fluorescence probe of silicon nanoparticles (SiNPs). The fluorescence of the synthetic SiNPs was gradually quenched in the presence of Fe3+ ion and slightly recovered with the addition of F− ion owing to the formation of a stable and colorless ferric fluoride. The fluorescence recovery exhibited a good linear relationship (R2 = 0.9992) as the concentration of F− ion increased from 0 to 100 μmol·L−1. The detection limit of the established method of F− ion was 0.05 μmol·L−1. The recovery experiments confirmed the accuracy and reliability of the proposed method. The ultraviolet–visible spectra, fluorescence decays, and zeta potentials evidenced the fluorescence quenching mechanism involving the electron transfer between the SiNPs and Fe3+ ion, while the fluorescence recovery resulted from the formation of ferric fluoride. Finally, SiNPs were successfully applied to detect F− ions in tap water, Antarctic krill, and Antarctic krill powder.
- 10 January 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (2) , 213
Open Access“Switch-Off-On” Detection of Fe3+ and F− Ions Based on Fluorescence Silicon Nanoparticles and Their Application to Food Samples
An approach to the detection of F− ions in food samples was developed based on a “switch-off-on” fluorescence probe of silicon nanoparticles (SiNPs). The fluorescence of the synthetic SiNPs was gradually quenched in the presence of Fe3+ ion and slightly recovered with the addition of F− ion owing to the formation of a stable and colorless ferric fluoride. The fluorescence recovery exhibited a good linear relationship (R2 = 0.9992) as the concentration of F− ion increased from 0 to 100 μmol·L−1. The detection limit of the established method of F− ion was 0.05 μmol·L−1. The recovery experiments confirmed the accuracy and reliability of the proposed method. The ultraviolet–visible spectra, fluorescence decays, and zeta potentials evidenced the fluorescence quenching mechanism involving the electron transfer between the SiNPs and Fe3+ ion, while the fluorescence recovery resulted from the formation of ferric fluoride. Finally, SiNPs were successfully applied to detect F− ions in tap water, Antarctic krill, and Antarctic krill powder.