Wei Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Wei Li has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Aixian Liu
Neurological Rehabilitation Center, Beijing Rehabilitation Hospital Affiliated to Capital Medical University, Beijing, China
2 shared publications- Chong Li
School of Clinical Medicine (BTCH), Tsinghua Medicine, Tsinghua University, Beijing, China
2 shared publications Linhong Ji
Division of Intelligent and Biomechanical System, Department of Mechanical Engineering, Tsinghua University, Beijing, China
2 shared publicationsLinhong Mo
Neurological Rehabilitation Center, Beijing Rehabilitation Hospital Affiliated to Capital Medical University, Beijing, China
2 shared publicationsQuan Xu
Division of Intelligent and Biomechanical Systems, State Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Haidian, Beijing, China
2 shared publicationsChong Li
1 shared publication
Latest Publications
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 42 (15523098) , 302-321
Design, Modeling, and Application of Bioinspired High-Force-Output Soft Pneumatic Bending Actuator
Soft robotic devices, known for their high compliance, are increasingly being used in assistance and rehabilitation. However, the limited force output of soft actuators has hindered their broader adoption. In this study, a lobster-tail-inspired high-force-output soft pneumatic bending actuator (SPBA) is developed, featuring a soft deformable body and a rigid kirigami limiting shell. The SPBA, with a radius of 10 mm, can generate forces of approximately 22 N at an internal pressure of 0.1 MPa and 36.43 N at 0.16 MPa. An analytical model based on the Euler–Bernoulli beam theory, incorporating a hyperelastic material model, has been constructed to predict the deformation and force of the actuated SPBA. This model demonstrates good agreement with simulated and experimental results. For assistance, a soft robotic gripper with four SPBAs can lift a weight of 5.38 kg at 0.26 MPa. For rehabilitation, an SPBA-based hand exoskeleton has been developed, demonstrating significant effectiveness in mitigating hand spasticity following strokes. This study introduces a novel SPBA design with promising potential for future applications in grasping, assistance, and rehabilitation.
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 42 (15523098) , 302-321
Design, Modeling, and Application of Bioinspired High-Force-Output Soft Pneumatic Bending Actuator
Soft robotic devices, known for their high compliance, are increasingly being used in assistance and rehabilitation. However, the limited force output of soft actuators has hindered their broader adoption. In this study, a lobster-tail-inspired high-force-output soft pneumatic bending actuator (SPBA) is developed, featuring a soft deformable body and a rigid kirigami limiting shell. The SPBA, with a radius of 10 mm, can generate forces of approximately 22 N at an internal pressure of 0.1 MPa and 36.43 N at 0.16 MPa. An analytical model based on the Euler–Bernoulli beam theory, incorporating a hyperelastic material model, has been constructed to predict the deformation and force of the actuated SPBA. This model demonstrates good agreement with simulated and experimental results. For assistance, a soft robotic gripper with four SPBAs can lift a weight of 5.38 kg at 0.26 MPa. For rehabilitation, an SPBA-based hand exoskeleton has been developed, demonstrating significant effectiveness in mitigating hand spasticity following strokes. This study introduces a novel SPBA design with promising potential for future applications in grasping, assistance, and rehabilitation.
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-14
Nonconvex Sparse Regularization Method for Eyeblink Artifact Suppression From Single-Channel EEG Signals
Recent advancements in affordable single-channel Electroencephalography (EEG) devices have garnered considerable attention due to their ability to reduce hardware complexity. However, effectively suppressing eyeblink artifacts in single-channel EEG signals remains a substantial challenge for biomedical applications. This paper proposes a nonconvex sparse regularization methodology (NSRM), which explores the generalized minimax-concave penalty for eyeblink artifact suppression from single-channel EEG signals. The contaminated EEG signals can be initially modeled within the sparse representation framework as a combination of target and noise components. The proposed methodology preserves the convexity of sparsity-regularized least square objective function, allowing the global minimum to be reached through convex optimization. Specifically, a forward-backward splitting algorithm is developed to resolve the nonconvex sparse regularization problem of eyeblink artifact suppression. Additionally, we introduce an adaptive selection strategy for the regularization parameter. The advantage over conventional methods is that NSRM can better preserve useful information from EEG signals while suppressing eyeblink artifacts. To validate the efficacy of NSRM, a semi-simulated EEG dataset and two real experiment datasets have been analyzed. Results demonstrate that our NSRM methodology eliminates eyeblink artifacts effectively and accurately from single-channel EEG signals, outperforming the L1 norm-based sparse regularization method, as evidenced by quantitative metrics. Finally, comparison results with the advanced K-means singular value decomposition have also confirmed the superiority of our proposed NSRM for eyeblink artifact suppression in the context of sparse representation paradigm.
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-14
Nonconvex Sparse Regularization Method for Eyeblink Artifact Suppression From Single-Channel EEG Signals
Recent advancements in affordable single-channel Electroencephalography (EEG) devices have garnered considerable attention due to their ability to reduce hardware complexity. However, effectively suppressing eyeblink artifacts in single-channel EEG signals remains a substantial challenge for biomedical applications. This paper proposes a nonconvex sparse regularization methodology (NSRM), which explores the generalized minimax-concave penalty for eyeblink artifact suppression from single-channel EEG signals. The contaminated EEG signals can be initially modeled within the sparse representation framework as a combination of target and noise components. The proposed methodology preserves the convexity of sparsity-regularized least square objective function, allowing the global minimum to be reached through convex optimization. Specifically, a forward-backward splitting algorithm is developed to resolve the nonconvex sparse regularization problem of eyeblink artifact suppression. Additionally, we introduce an adaptive selection strategy for the regularization parameter. The advantage over conventional methods is that NSRM can better preserve useful information from EEG signals while suppressing eyeblink artifacts. To validate the efficacy of NSRM, a semi-simulated EEG dataset and two real experiment datasets have been analyzed. Results demonstrate that our NSRM methodology eliminates eyeblink artifacts effectively and accurately from single-channel EEG signals, outperforming the L1 norm-based sparse regularization method, as evidenced by quantitative metrics. Finally, comparison results with the advanced K-means singular value decomposition have also confirmed the superiority of our proposed NSRM for eyeblink artifact suppression in the context of sparse representation paradigm.
- Open Access
- 13 November 2023
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 20 (1) , 1-15
Lesion-specific cortical activation following sensory stimulation in patients with subacute stroke
Background: Sensory stimulation can play a fundamental role in the activation of the primary sensorimotor cortex (S1-M1), which can promote motor learning and M1 plasticity in stroke patients. However, studies have focused mainly on investigating the influence of brain lesion profiles on the activation patterns of S1-M1 during motor tasks instead of sensory tasks. Therefore, the objective of this study is to explore the lesion-specific activation patterns due to different brain lesion profiles and types during focal vibration (FV). Methods: In total 52 subacute stroke patients were recruited in this clinical experiment, including patients with basal ganglia hemorrhage/ischemia, brainstem ischemia, other subcortical ischemia, cortical ischemia, and mixed cortical–subcortical ischemia. Electroencephalograms (EEG) were recorded following a resting state lasting for 4 min and three sessions of FV. FV was applied over the muscle belly of the affected limb’s biceps for 3 min each session. Beta motor-related EEG power desynchronization overlying S1-M1 was used to indicate the activation of S1-M1, while the laterality coefficient (LC) of the activation of S1-M1 was used to assess the interhemispheric asymmetry of brain activation. Results: (1) Regarding brain lesion profiles, FV could lead to the significant activation of bilateral S1-M1 in patients with basal ganglia ischemia and other subcortical ischemia. The activation of ipsilesional S1-M1 in patients with brainstem ischemia was higher than that in patients with cortical ischemia. No activation of S1-M1 was observed in patients with lesions involving cortical regions. (2) Regarding brain lesion types, FV could induce the activation of bilateral S1-M1 in patients with basal ganglia hemorrhage, which was significantly higher than that in patients with basal ganglia ischemia. Additionally, LC showed no significant correlation with the modified Barthel index (MBI) in all patients, but a positive correlation with MBI in patients with basal ganglia lesions. Conclusions: These results reveal that sensory stimulation can induce lesion-specific activation patterns of S1-M1. This indicates FV could be applied in a personalized manner based on the lesion-specific activation of S1-M1 in stroke patients with different lesion profiles and types. Our study may contribute to a better understanding of the underlying mechanisms of cortical reorganization.
- 13 November 2023
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 20 (1) , 1-15
Open AccessLesion-specific cortical activation following sensory stimulation in patients with subacute stroke
Background: Sensory stimulation can play a fundamental role in the activation of the primary sensorimotor cortex (S1-M1), which can promote motor learning and M1 plasticity in stroke patients. However, studies have focused mainly on investigating the influence of brain lesion profiles on the activation patterns of S1-M1 during motor tasks instead of sensory tasks. Therefore, the objective of this study is to explore the lesion-specific activation patterns due to different brain lesion profiles and types during focal vibration (FV). Methods: In total 52 subacute stroke patients were recruited in this clinical experiment, including patients with basal ganglia hemorrhage/ischemia, brainstem ischemia, other subcortical ischemia, cortical ischemia, and mixed cortical–subcortical ischemia. Electroencephalograms (EEG) were recorded following a resting state lasting for 4 min and three sessions of FV. FV was applied over the muscle belly of the affected limb’s biceps for 3 min each session. Beta motor-related EEG power desynchronization overlying S1-M1 was used to indicate the activation of S1-M1, while the laterality coefficient (LC) of the activation of S1-M1 was used to assess the interhemispheric asymmetry of brain activation. Results: (1) Regarding brain lesion profiles, FV could lead to the significant activation of bilateral S1-M1 in patients with basal ganglia ischemia and other subcortical ischemia. The activation of ipsilesional S1-M1 in patients with brainstem ischemia was higher than that in patients with cortical ischemia. No activation of S1-M1 was observed in patients with lesions involving cortical regions. (2) Regarding brain lesion types, FV could induce the activation of bilateral S1-M1 in patients with basal ganglia hemorrhage, which was significantly higher than that in patients with basal ganglia ischemia. Additionally, LC showed no significant correlation with the modified Barthel index (MBI) in all patients, but a positive correlation with MBI in patients with basal ganglia lesions. Conclusions: These results reveal that sensory stimulation can induce lesion-specific activation patterns of S1-M1. This indicates FV could be applied in a personalized manner based on the lesion-specific activation of S1-M1 in stroke patients with different lesion profiles and types. Our study may contribute to a better understanding of the underlying mechanisms of cortical reorganization.