Anoop S. Chandrashekar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anoop S. Chandrashekar has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
J. Ryan Martin
Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
7 shared publicationsGregory G. Polkowski
Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
5 shared publicationsLogan M. Locascio
Vanderbilt University School of Medicine, Nashville, Tennessee
4 shared publications- Chad M. Vezina
Department of Comparative Biosciences, University of Wisconsin-Madison, Madison, WI, USA
3 shared publications - Diya Binoy Joseph
Institute for Stem Cell Science and Regenerative Medicine (BRIC-inStem), GKVK-Post, Bellary Road, Bengaluru 560065, India
3 shared publications Emily R. Oleisky
Vanderbilt University School of Medicine, Nashville, Tennessee
3 shared publications
Latest Publications
- 1 July 2026
- Published by SAGE Publications in HIP International
Short-term survivorship of a novel acetabular component with a combination of non-locking and variable-angle locking screws in complex acetabular reconstruction
Background: Highly porous shells have been used with success to manage acetabular bone loss in complex (cTHA) and revision total hip arthroplasty (rTHA) for nearly 2 decades. Recently, a 3D-printed titanium shell with locking screw technology was developed. Our study sought to evaluate the survivorship of the novel variable-angle locking screw (VALS) acetabular component. Methods: This multicentre retrospective study analysed cTHA ( n = 61) and rTHA (n = 145) using the VALS component. 206 patients were included in the final analysis, with a mean age of 65.1 (range 15–95) years, mean BMI of 30.9 ± 7.3 kg/m 2 , and 60.2% women. Mean follow-up was 1.1 (range 0.1–5.1) years. The Kaplan-Meier analysis was utilised to assess implant survivorship and reoperation. Results: Of the 206 included cases, 20 were reoperations, 9 of which involved acetabular revision. The 1-year and 2-year acetabular component revision-free survivorship was 95 and 94%, and all-cause reoperation was 90 and 86%, respectively. Importantly, there were only 2 cases of aseptic acetabular loosening identified. Conclusions: The novel VALS component demonstrated encouraging early survivorship with a low incidence of complications when utilised in complex acetabular reconstruction. Further studies are warranted to assess long-term survivorship.
- 1 July 2026
- Published by SAGE Publications in HIP International
Short-term survivorship of a novel acetabular component with a combination of non-locking and variable-angle locking screws in complex acetabular reconstruction
Background: Highly porous shells have been used with success to manage acetabular bone loss in complex (cTHA) and revision total hip arthroplasty (rTHA) for nearly 2 decades. Recently, a 3D-printed titanium shell with locking screw technology was developed. Our study sought to evaluate the survivorship of the novel variable-angle locking screw (VALS) acetabular component. Methods: This multicentre retrospective study analysed cTHA ( n = 61) and rTHA (n = 145) using the VALS component. 206 patients were included in the final analysis, with a mean age of 65.1 (range 15–95) years, mean BMI of 30.9 ± 7.3 kg/m 2 , and 60.2% women. Mean follow-up was 1.1 (range 0.1–5.1) years. The Kaplan-Meier analysis was utilised to assess implant survivorship and reoperation. Results: Of the 206 included cases, 20 were reoperations, 9 of which involved acetabular revision. The 1-year and 2-year acetabular component revision-free survivorship was 95 and 94%, and all-cause reoperation was 90 and 86%, respectively. Importantly, there were only 2 cases of aseptic acetabular loosening identified. Conclusions: The novel VALS component demonstrated encouraging early survivorship with a low incidence of complications when utilised in complex acetabular reconstruction. Further studies are warranted to assess long-term survivorship.
- Open Access
- 25 August 2025
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 41 (4) , 1027-1035
Body Mass Index > 40 Is Not Correlated With Early Complications in Patients Undergoing Primary Total Joint Arthroplasty at an Ambulatory Surgical Center
- 25 August 2025
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 41 (4) , 1027-1035
Open AccessBody Mass Index > 40 Is Not Correlated With Early Complications in Patients Undergoing Primary Total Joint Arthroplasty at an Ambulatory Surgical Center
- Open Access
- 9 June 2025
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 41 (1) , 96-102
Development of a Machine Learning Model for Determining Alignment in Knees Following Total Knee Arthroplasty
- 9 June 2025
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 41 (1) , 96-102
Open AccessDevelopment of a Machine Learning Model for Determining Alignment in Knees Following Total Knee Arthroplasty
- Open Access
- 2 June 2025
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 40 (12) , 3303-3307
Expecting the Unexpected: Incidence and Management of Intraoperative Complications in Primary Total Joint Arthroplasty at Ambulatory Surgery Centers
- 2 June 2025
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 40 (12) , 3303-3307
Open AccessExpecting the Unexpected: Incidence and Management of Intraoperative Complications in Primary Total Joint Arthroplasty at Ambulatory Surgery Centers
- Open Access
- 19 May 2025
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 40 (11) , 2852-2858
Should We Expand Outpatient Total Joint Selection Criteria? Re-exploring Hard Stop Criteria
- 19 May 2025
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 40 (11) , 2852-2858
Open AccessShould We Expand Outpatient Total Joint Selection Criteria? Re-exploring Hard Stop Criteria
- Open Access
- 1 January 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (1) , e70220
Intraoperative robotic measurements of coronal alignment in total knee arthroplasty correlate with pre‐ and post‐operative long‐leg radiographs
Purpose: This study sought to validate intraoperative robotic measurements of femoral and tibial component coronal alignment in total knee arthroplasty (TKA) by comparing to pre‐ and post‐operative standing, double stance, long‐leg radiographs (LLR).Methods: This retrospective cohort study included 59 unique patients undergoing primary TKA at a single institution. Pre‐ and post‐operative femoral and tibial coronal alignment were measured on LLRs using a deep learning artificial intelligence model and compared to measurements obtained from the imageless robotic system to evaluate the robot's accuracy and reliability.Results: Robotic measurements were highly correlated with measurements from preoperative LLR (Pearson r2 = 0.68). There was no significant difference in preoperative constitutional alignment between the two methodologies (p = 0.28). Additionally, the intraoperative and post‐operative alignment of femoral and tibial implants were not significantly different (p = 0.12 and p = 0.95, respectively) and were strongly correlated (Pearson r2 = 0.5 and Pearson r2 = 0.6 respectively). The mean difference in femoral alignment was 0.43° and the mean difference in tibial alignment was 0.01°.Conclusions: The findings of this study suggest that there were no significant differences in the coronal alignment of TKA when assessed by a robotic system compared to LLR. This signifies the robotic system's high intraoperative accuracy and reliability in determining coronal alignment.Level of Evidence: Level III.
- 1 January 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (1) , e70220
Open AccessIntraoperative robotic measurements of coronal alignment in total knee arthroplasty correlate with pre‐ and post‐operative long‐leg radiographs
Purpose: This study sought to validate intraoperative robotic measurements of femoral and tibial component coronal alignment in total knee arthroplasty (TKA) by comparing to pre‐ and post‐operative standing, double stance, long‐leg radiographs (LLR).Methods: This retrospective cohort study included 59 unique patients undergoing primary TKA at a single institution. Pre‐ and post‐operative femoral and tibial coronal alignment were measured on LLRs using a deep learning artificial intelligence model and compared to measurements obtained from the imageless robotic system to evaluate the robot's accuracy and reliability.Results: Robotic measurements were highly correlated with measurements from preoperative LLR (Pearson r2 = 0.68). There was no significant difference in preoperative constitutional alignment between the two methodologies (p = 0.28). Additionally, the intraoperative and post‐operative alignment of femoral and tibial implants were not significantly different (p = 0.12 and p = 0.95, respectively) and were strongly correlated (Pearson r2 = 0.5 and Pearson r2 = 0.6 respectively). The mean difference in femoral alignment was 0.43° and the mean difference in tibial alignment was 0.01°.Conclusions: The findings of this study suggest that there were no significant differences in the coronal alignment of TKA when assessed by a robotic system compared to LLR. This signifies the robotic system's high intraoperative accuracy and reliability in determining coronal alignment.Level of Evidence: Level III.
- Open Access
- 23 November 2024
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 40 (6) , 1465-1470
Outpatient Total Joint Arthroplasty at an Ambulatory Surgical Center: An Analysis of Failure to Launch
- 23 November 2024
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 40 (6) , 1465-1470
Open AccessOutpatient Total Joint Arthroplasty at an Ambulatory Surgical Center: An Analysis of Failure to Launch
- Open Access
Standardizing Phenotypic Algorithms for the Classification of Degenerative Rotator Cuff Tear from Electronic Health Record Systems
Background: Degenerative rotator cuff tears (DCTs) are the leading cause of shoulder pain, affecting 30% to 50% of individuals over 50. Current phenotyping strategies for DCT rely on heterogeneous combinations of procedural and diagnostic codes, leading to concerns about misclassification. We aimed to create universal phenotypic algorithms to classify DCT status across EHR systems. Methods: Using Vanderbilt University Medical Center’s de-identified EHR system, we developed and validated two sets of algorithms—one requiring imaging verification and one without imaging verification—to identify DCT cases and controls. The algorithms used combinations of ICD and CPT codes, as well as natural language processing (NLP), to increase diagnostic certainty. Manual chart reviews by trained personnel blinded to case-control determinations were conducted to compute positive (PPV) and negative predictive values (NPV). Results: The algorithm development process resulted in five phenotypes with an overall predictive value of 94.5%. By approach: 1) code only cases that required imaging confirmation (PPV = 89%), 2) code only cases that did not require imaging verification (PPV = 92%), 3) NLP-based cases that did not require imaging verification (PPV = 89%), 4) code-based controls that were confirmed by imaging (NPV = 90%), and 5) code and NLP-based controls that did not require imaging verification (NPV = 100%). External validation demonstrated 94% sensitivity and 75% specificity for the code-only algorithms. The addition of NLP increased the number of identified cases without compromising predictive values. Conclusions: These algorithms represent an improvement over current phenotyping strategies and allows for EHR studies of unprecedented size
Open AccessStandardizing Phenotypic Algorithms for the Classification of Degenerative Rotator Cuff Tear from Electronic Health Record Systems
Background: Degenerative rotator cuff tears (DCTs) are the leading cause of shoulder pain, affecting 30% to 50% of individuals over 50. Current phenotyping strategies for DCT rely on heterogeneous combinations of procedural and diagnostic codes, leading to concerns about misclassification. We aimed to create universal phenotypic algorithms to classify DCT status across EHR systems. Methods: Using Vanderbilt University Medical Center’s de-identified EHR system, we developed and validated two sets of algorithms—one requiring imaging verification and one without imaging verification—to identify DCT cases and controls. The algorithms used combinations of ICD and CPT codes, as well as natural language processing (NLP), to increase diagnostic certainty. Manual chart reviews by trained personnel blinded to case-control determinations were conducted to compute positive (PPV) and negative predictive values (NPV). Results: The algorithm development process resulted in five phenotypes with an overall predictive value of 94.5%. By approach: 1) code only cases that required imaging confirmation (PPV = 89%), 2) code only cases that did not require imaging verification (PPV = 92%), 3) NLP-based cases that did not require imaging verification (PPV = 89%), 4) code-based controls that were confirmed by imaging (NPV = 90%), and 5) code and NLP-based controls that did not require imaging verification (NPV = 100%). External validation demonstrated 94% sensitivity and 75% specificity for the code-only algorithms. The addition of NLP increased the number of identified cases without compromising predictive values. Conclusions: These algorithms represent an improvement over current phenotyping strategies and allows for EHR studies of unprecedented size
- Open Access
- 2 September 2024
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 40 (2) , 294-300.e1
Socioeconomic Indices Are Associated With Increased Resource Utilizations, but Not 90-Day Complications Following Total Hip and Knee Arthroplasty
- 2 September 2024
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 40 (2) , 294-300.e1
Open AccessSocioeconomic Indices Are Associated With Increased Resource Utilizations, but Not 90-Day Complications Following Total Hip and Knee Arthroplasty
- Open Access
- 29 May 2024
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 39 (11) , 2669-2674.e1
Is a Failed Spinal Attempt Associated With a Worse Clinical Course Following Primary Total Hip and Knee Arthroplasty?
- 29 May 2024
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 39 (11) , 2669-2674.e1
Open AccessIs a Failed Spinal Attempt Associated With a Worse Clinical Course Following Primary Total Hip and Knee Arthroplasty?