LBLuan Ferreira Bastos

Luan Ferreira Bastos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Luan Ferreira Bastos has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Forensic significance of dental cementum

    by Pedro Américo Felizardo dos Santos, Vanessa Moreira Andrade, Luan Ferreira Bastos, Luciana Pereira Da Silva, Ricardo Tadeu Lopes, Aline de Almeida Neves, Andreia Cristina Breda de Souza, Maria Augusta Visconti

    Aim: To determine new energy parameters in micro-CT to allow appropriate segmentation of dental cementum from the surrounding structures. Methods: For this pilot study, 11 single-rooted premolar teeth of young subjects aged 12 to 21 were selected. The teeth were scanned using high-energy microtomography (SkyScan 1173, Bruker) with varying acquisition energies (60, 70, and 80 kV). Each tooth was scanned three times. The images were reconstructed and analyzed by calculating the volume (mm³) of dental cementum in the cervical, middle, and apical root thirds among the different scanned stacks. The mean cementum volume in the root thirds was obtained, and correlated with the patient’s age, using Pearson’s correlation. Results: The mean age of the patients in the sample was 16,73 years. For the 60kV energy, the cementum volumes were 1.01 mm³, 1.00 mm³, and 0.58 mm³, for the cervical, middle, and apical thirds, respectively. For 70kV, it was 1.08 mm3, 1.20 mm3, and 0.71 mm3 for the respective thirds. And for 80kV, 0.55 mm3, 0.91 mm3, and 0.67 mm3 for the respective thirds. Conclusion: An acquisition energy of 70kV resulted in the best segmentation and reproducibility of the results. Micro-CT can be a useful tool to non-destructively evaluate the dental cementum.

  • The effect of root canal preparation tapers on planktonic bacteria and biofilm reduction in the apical third: A correlative microtomography and microbiological laboratory study

    by Fernanda Piffer Garcia Macedo, Adriana de Jesus Soares, Marília Fagury Videira Marceliano‐Alves, Elizabeth Martinez, Ricardo Lopes, Luan Ferreira Bastos, Wayne Martins Nascimento, Ana Grasiela Limoeiro, Marcos dos Frozoni

    Aim: To evaluate the influence of different preparation tapers on the reduction in planktonic bacteria and biofilms of Enterococcus faecalis and Candida albicans in the apical third (4 mm) of the mesial roots of mandibular molars, correlating decontamination with canal shape.Methodology: After microtomography analysis for morphological standardization of the canals, 48 mandibular molar roots, each containing two canals (96 canals), were contaminated with E. faecalis and C. albicans and divided into four groups (n = 11) for canal instrumentation using ProDesign Logic 2 files with different tapers G (.03): # 25.03; G (.04): # 25.04; G (.05): # 25.05; and G (.06): # 25.06 and irrigation with 2.5% sodium hypochlorite. Four roots were examined under a scanning electron microscope (SEM) to qualitatively assess biofilm formation. Eight roots were used as the negative control group (samples were not contaminated). Bacteriological samples were taken exclusively from the apical third of the roots before and after chemical–mechanical preparation and bacterial counts were determined (CFU/mL). The final micro‐CT scan was used to quantify the volume variation and unprepared canal area in the apical third. Statistical analysis was performed using the Kruskal–Wallis, Student–Newman–Keuls and Wilcoxon tests for analysis of microbiological data. anova and the Tukey or Games–Howell test were used for analysis of micro‐CT data and Spearman's test for correlations (α = 5%).Results: All groups showed a significant reduction in bacteria (p < .05), with no statistically significant difference between groups. There was no significant difference in per cent volume increase between groups. The unprepared area (Δ%) was affected by the file used (p = .026) and was significantly lower for G (.06) compared to G (.03). There was no statistically significant correlation among bacterial reduction, volume and unprepared area (p > .05).Conclusion: The different preparation tapers influenced root canal shaping in the apical third but did not improve decontamination in this region.


  • Intracanal removal and apical extrusion of filling material after retreatment using rotary or reciprocating instruments: A new approach using human cadavers

    by Thamyres M. Monteiro, Victor O. Cortes‐Cid, Marilia F. V. Marceliano‐Alves, Andrea F. Campello, Luan F. Bastos, Ricardo T. Lopes, José F. Siqueira, Flávio R. F. Alves

    Aim: This study compared intracanal removal of filling as well as the frequency and volume of extruded material after retreatment with either HyFlex or Reciproc instruments in mandibular teeth from cadavers.Methodology: The root canals of 14 pairs of contralateral single‐rooted teeth in mandibles of cadavers were instrumented with Reciproc R40 and filled using lateral compaction. The mandibles were scanned in a micro‐computed tomographic (micro‐CT) device before and after retreatment procedures. The contralateral teeth were assigned to two groups (n = 14) according to the retreatment protocol using either HyFlex or Reciproc instrument systems. In the HyFlex group, the HyFlex Remover instrument was worked 3 mm short of the working length (WL), followed by HyFlex CM 40.04 and 50.04 at the WL. In the Reciproc group, the R50 instrument was worked up at the coronal two thirds, followed by two more cycles until the WL was reached. Pre‐ and post‐operative micro‐CT images were analysed for extrusion and intracanal removal of filling material.Results: After retreatment, extrusion of filling material occurred in 11 (78%) and 14 (100%) teeth from HyFlex and Reciproc groups respectively (p > .05). A similar volume of extruded material was observed after retreatment with both systems (p > .05). A significant decrease in the intracanal filling volume was verified after retreatment with both tested systems (p < .05). However, residual filling material was found in all root canals, regardless of the system. The amount of filling material removed (HyFlex = 80.8%; Reciproc = 65.9%) and the operation time was similar between systems (p > .05).Conclusions: A high frequency of filling material extrusion was observed after retreatment with the two systems in a cadaver model, with no significant difference between them. Both protocols obtained similar efficacy in filling material removal procedures, although none completely cleaned the canals.


  • Open Access

    Shaping Ability of TRUShape and XP-endo Shaper in C-Shaped Canals Using 3D-Printed Replicas: A Micro-CT Study

    by Natália Pereira da Silva Falcão, Marilia Fagury Marceliano-Alves, Sandro Junio Oliveira Tavares, Pablo Amoroso-Silva, Aline de Almeida Neves, Luan Ferreira Bastos, Ricardo Tadeu Lopes, Wania Christina Figueiredo Dantas, Michelle Paiva Weydt Galhardi, Eduardo Fagury Videira Marceliano, et al.

    Objective This study compared the shaping ability of TRUShape and XP-endo Shaper systems on C-shaped root canals replicas using microcomputed tomography (micro-CT). Material and Methods Thirty three-dimensional replicas based on a mandibular second molar classified as C1 type I C-shaped canal were randomly divided into two groups (n = 15): TRUShape (G.TRU) and XP-endo Shaper (G.XP) and instrumented with each system according to the manufacturer's instructions. Changes in volume and surface and the unprepared area of the root canal were measured by scanning on micro-CT before and after instrumentation. Results The unprepared areas were 39% in the G.TRU and 43% in the G.XP group with no significant difference between them (p > 0.05), but both the tested systems left a high percentage of unprepared root canal walls of C-shaped root canals. Conclusion TRUShape and XP-endo Shaper showed a high rate of unprepared areas with similar results after C-shaped root canals replicas for root canal preparation.


  • X‐ray computed microtomography time‐dependent analysis of sandwich bread in different storage conditions

    by João Carlos R. de Lima, Olga M. O. de Araújo, Aline S. de Sá Silva, Luan F. Bastos, Alessandra S. Machado, Davi F. Oliveira, Ricardo T. Lopes

    Bread is one of the oldest foods of mankind, and among them, the sandwich bread is worldwide known and used. In this study we used the non‐destructive computed microtomography technique (microCT) to evaluate the behavior of bread structure over weeks after the production. In addition, the influence of the storage location of the sandwich bread, we performed a comparative analysis between storage at ambient temperature and refrigerated conditions. The analysis of the reconstructed images shows that the bread suffers loss of structure over the weeks. We also have found that keeping the bread refrigerated loses liquid, drying the bread, and thus increasing the loss of its structure. In addition, the porous structure of the bread was evaluated, and a complete characterization of the microstructural changes was performed over time.


  • Open Access

    Comparison Between Radiographs, White and Fluorescent Images in the Diagnosis and Treatment Decisions for Occlusal Caries: An Ex Vivo Study

    by Luciana Pereira da Silva, Luan Ferreira Bastos, Clara Silva Avellar Mascarenhas, Ricardo Tadeu Lopes, Michelle Mikhael Ammari, Luciana Pomarico, Ivete Pomarico Ribeiro de Souza, Maria Augusta Visconti, Aline de Almeida Neves

  • Open Access

    Evaluation of mass attenuation coefficient of concrete sample for different traits

    by Luan Ferreira Bastos, Tâmara Teixeira, Hamilton Gama Filho, Sebastião Calixto, Marcelo Gonçalves, Marcelino Dos Anjos, Ricardo Tadeu Lopes, Davi Ferreira de Oliveira

    Concrete is widely used in the world and is the main material for civil construction. Due to its properties, it has different uses such as structural, filling and shielding. The aim of this work is to compare experimental and theoretical mass attenuation coefficient for concrete with different traits and determine the one with the best performance. For this, density, X-ray diffraction, mass attenuation coefficient (experimental with a Cs137 source, simulated by MCNP and theoretical determined with XCOM platform) and compressive strength were determined for three different traits of cement mortar (standardized sand, conventional sand and artificial sand). The X-ray diffraction showed more compounds for artificial sand’s samples. Density showed no significant variation. The samples showed a good agreement for experimental, simulated and theoretical mass attenuation coefficient. Standardized sand’s samples had the best performance for mechanical test, with a compressive strength 47.4% higher than artificial sand’s samples and 38.2% higher than conventional sand’s samples. It is possible to conclude that, since mass attenuation coefficient showed no significant difference, standardized sand’s samples is more indicated to be used for shielding than the others.

  • Open Access

    Appreciation of influence of acquisition parameters in analysis of root canal using microCT system

    by Luan Ferreira Bastos, Olga Maria Oliveira De Araújo, Caio Márcio Sorrentino de Freitas Farias Dos Santos, Tâmara Porfíro Teixeira, Renata Périssé Nobili Funcke, João Carlos Rocha De Lima, Alessandra Silveira Machado, Davi Ferreira Oliveira, Ricardo Tadeu Lopes

    Microtomography is successfully used in the odontological evaluation and treatments, as it´s capable to analyze the bone tissue and any possible damage in its root canal caused by a surgical intervention. In this study, the microCT was used to analyze the images by using different parameters in the acquisition process, as two matrix sizes: 1120x1120 pixels and 2240x2240 pixels. After the reconstruction, the volume of the root canal was analyzed, as well as the quantification of a remaining tooth closure material. The results showed that the detector array 1120X1120 was able to capture values close to those of the 2240x2240 matrix for the volume of root canal and for the residual material after treatment. Remaining tooth closure material correspond an average of 0.95 mm³ for 1120x1120 pixels, while the corresponding volume for 2240x2240 pixels was 0.90 mm³. Results for root canal volume average was 10.32 mm³ for 1120x1120 pixels, while for 2240x2240 pixels was 10.22 mm³. In this way, the difference of the detected volume between the two matrices is of 5.47% for the residual material and 0.93% for root canal volume. In a qualitative analyze, the 2240x2240 matrix allows the identification of a greater amount of details. However, it was possible to verify that depending on the application and the region of interest studied the smaller matrix can offer reliable results and a shorter processing time.