Samir Flazi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Samir Flazi has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
A. Boudghene Stambouli
University of Sciences and Technology of Oran, USTO-MB Algeria
9 shared publicationsH. Hadi
University of Sciences and Technology of Orao, Mahamed Boudiaf, Algeria
6 shared publicationsH. Koinuma
Sahara Solar Breeder Foundation International
5 shared publicationsZ. Khiat
5 shared publicationsAmine Boudghene Stambouli
4 shared publicationsA. Ouis
High Voltage laboratory, Faculty of Electrical Engineering, University of Science and Technology of Oran, BP 1505 EL M'naouer Oran 31000, Algeria
3 shared publications
Latest Publications
- 1 November 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Pipeline Systems Engineering and Practice
- Vol. 13 (4) , 04022043
Novel Electrical Technique for Detecting Water Leaks in Buried Plastic Water Distribution Pipes
In old distribution networks, water leaks cause significant losses, which can reach 50%; therefore, locating and correcting these leaks is crucial and is an eco-friendly measure, especially in places with few water sources. In this paper, a novel electrical technique is proposed to locate leaks in underground pipelines made of electrical insulated materials. This technique is based on the difference in the electrical resistance between the water and the pipe environment. It locates leaks by specifying the location that gives the greatest current value or the smallest resistance value in a circuit between a fixed reference point on a water pipe and a moving point on the surface. When the moving point is above a water leak point, the electrical resistance is minimum, that is, the location that gives the minimum electrical resistance or the maximum current is above the water leak point. This technique is advantageous because it is easy to implement, requires simple equipment, and can be used to detect leaks, however small, instantly at the start of the leak. Simulation and experimental studies on the effect of several parameters affecting the precision of this technique were also performed. Voltage values of 10, 20, and 30 V at a frequency of 1,000 Hz, two PVC tubes with diameters of 4 and 6 cm, and earth resistivity values of 100, 250, and were used. The experiments showed that the higher the voltage, the better the accuracy, and the same goes for the pipe diameter. As for the soil resistivity, the middle values give the best precision. The experimental measurements and the simulation study, using COMSOL Multiphysics software, validated this technique.- 1 November 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Pipeline Systems Engineering and Practice
- Vol. 13 (4) , 04022043
Novel Electrical Technique for Detecting Water Leaks in Buried Plastic Water Distribution Pipes
In old distribution networks, water leaks cause significant losses, which can reach 50%; therefore, locating and correcting these leaks is crucial and is an eco-friendly measure, especially in places with few water sources. In this paper, a novel electrical technique is proposed to locate leaks in underground pipelines made of electrical insulated materials. This technique is based on the difference in the electrical resistance between the water and the pipe environment. It locates leaks by specifying the location that gives the greatest current value or the smallest resistance value in a circuit between a fixed reference point on a water pipe and a moving point on the surface. When the moving point is above a water leak point, the electrical resistance is minimum, that is, the location that gives the minimum electrical resistance or the maximum current is above the water leak point. This technique is advantageous because it is easy to implement, requires simple equipment, and can be used to detect leaks, however small, instantly at the start of the leak. Simulation and experimental studies on the effect of several parameters affecting the precision of this technique were also performed. Voltage values of 10, 20, and 30 V at a frequency of 1,000 Hz, two PVC tubes with diameters of 4 and 6 cm, and earth resistivity values of 100, 250, and were used. The experiments showed that the higher the voltage, the better the accuracy, and the same goes for the pipe diameter. As for the soil resistivity, the middle values give the best precision. The experimental measurements and the simulation study, using COMSOL Multiphysics software, validated this technique.- Open Access
- 1 June 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 12 (3) , 2214-2219
Electrical impedance’s effects of flying insects on selectivity of electrical insecticides
The history of controlling destructive insects in the twentieth century makes it clear that the difficulties we encounter today in dealing with these types of insects come from our almost total reliance on one single controlling method, namely the use of chemical insecticides. These toxic and suspected carcinogenic products pose a serious threat to agriculture and the environment. However, the possibility of directing researchers in developing a new way considered as more efficient, more selective and less toxic has proved to be possible. The principle of this approach is based on an attractive effect and an electric effect. Nevertheless, the development of a bio and selective electrical system requires taking into account certain parameters involved in the attraction of insects and electrical discharge such as the electrical impedance. The results showed that the threshold at which the insect is disturbed depends on its conductivity.
- 1 June 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 12 (3) , 2214-2219
Open AccessElectrical impedance’s effects of flying insects on selectivity of electrical insecticides
The history of controlling destructive insects in the twentieth century makes it clear that the difficulties we encounter today in dealing with these types of insects come from our almost total reliance on one single controlling method, namely the use of chemical insecticides. These toxic and suspected carcinogenic products pose a serious threat to agriculture and the environment. However, the possibility of directing researchers in developing a new way considered as more efficient, more selective and less toxic has proved to be possible. The principle of this approach is based on an attractive effect and an electric effect. Nevertheless, the development of a bio and selective electrical system requires taking into account certain parameters involved in the attraction of insects and electrical discharge such as the electrical impedance. The results showed that the threshold at which the insect is disturbed depends on its conductivity.
- 7 March 2022
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (3) , 76-80
Novel Self-Evacuating Electrostatic Precipitator (SE-ESP)
W tym artykule przedstawiliśmy nowy prototyp elektrofiltru (ESP). Szczegółowo nakreślono tryb pracy i komponenty prototypu. Następnie z pierwotnie proponowanego modelu podstawowego powstały trzy wersje ESP. Modele te zostały przetestowane eksperymentalnie, a ich metoda postępowania została zweryfikowana za pomocą ustalonych symulacji opracowanych przy użyciu oprogramowania COMSOL Multiphysics Software. Ponadto porównano właściwości i skuteczność filtracji elektrostatycznej trzech modeli. (Nowatorski elektrofiltr samozasysający (SE-ESP)
- 7 March 2022
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (3) , 76-80
Novel Self-Evacuating Electrostatic Precipitator (SE-ESP)
W tym artykule przedstawiliśmy nowy prototyp elektrofiltru (ESP). Szczegółowo nakreślono tryb pracy i komponenty prototypu. Następnie z pierwotnie proponowanego modelu podstawowego powstały trzy wersje ESP. Modele te zostały przetestowane eksperymentalnie, a ich metoda postępowania została zweryfikowana za pomocą ustalonych symulacji opracowanych przy użyciu oprogramowania COMSOL Multiphysics Software. Ponadto porównano właściwości i skuteczność filtracji elektrostatycznej trzech modeli. (Nowatorski elektrofiltr samozasysający (SE-ESP)
- 13 June 2019
- Published by Periodica Polytechnica Budapest University of Technology and Economics in Periodica Polytechnica Electrical Engineering and Computer Science
- Vol. 63 (3) , 191-201
Accurate Estimation of Frequency-Dependent Losses in High Voltage Test Transformers for the Assessment of Electric Discharge Powers
The work presented in this paper is related to the project GEMUDE (Genérateur Multifonction de Décharge Electrique) which aims to design a universal high-voltage generator for electrical discharge studies. To design this variable high voltage source that operates in the frequency range of 0 to 1 kHz, the assessment of transformer losses represents a crucial phase during the design process. These losses in the coils and iron core of the transformer are closely related to the frequency and nature of the materials used. This paper presents a comparative study of transformer losses using analytical methods and experimental calorimetry measurements. Steinmetz empirical formula is used to estimate magnetic core losses whereas coil losses are evaluated by solving Maxwell equations. The main goal is to control these losses to limit the internal temperature rise in the transformer through the implementation of an efficient cooling solution. The results obtained by the analytical method were satisfactory which confirm the feasibility of measuring the power absorbed by the various electrical discharge devices upstream of the high-voltage transformer. This is because it turns out that the power of the generator in charge is the total power of the electric discharge and the transformer losses. This method, termed Power Disparity Method (PDM). In this paper, it is an easy and reliable way as compared with high voltage measurement methods.
- 13 June 2019
- Published by Periodica Polytechnica Budapest University of Technology and Economics in Periodica Polytechnica Electrical Engineering and Computer Science
- Vol. 63 (3) , 191-201
Accurate Estimation of Frequency-Dependent Losses in High Voltage Test Transformers for the Assessment of Electric Discharge Powers
The work presented in this paper is related to the project GEMUDE (Genérateur Multifonction de Décharge Electrique) which aims to design a universal high-voltage generator for electrical discharge studies. To design this variable high voltage source that operates in the frequency range of 0 to 1 kHz, the assessment of transformer losses represents a crucial phase during the design process. These losses in the coils and iron core of the transformer are closely related to the frequency and nature of the materials used. This paper presents a comparative study of transformer losses using analytical methods and experimental calorimetry measurements. Steinmetz empirical formula is used to estimate magnetic core losses whereas coil losses are evaluated by solving Maxwell equations. The main goal is to control these losses to limit the internal temperature rise in the transformer through the implementation of an efficient cooling solution. The results obtained by the analytical method were satisfactory which confirm the feasibility of measuring the power absorbed by the various electrical discharge devices upstream of the high-voltage transformer. This is because it turns out that the power of the generator in charge is the total power of the electric discharge and the transformer losses. This method, termed Power Disparity Method (PDM). In this paper, it is an easy and reliable way as compared with high voltage measurement methods.
- Open Access
- 1 June 2019
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 9 (3)
Parameters affecting the selectivity of an electrical insecticide
Using an electrical approach in the field of agriculture can be considered as one of the solutions in order to control harmful flying insects. This technique is based on the use of a bio and selective electrical insecticide whose principle consists in attracting insects by the light then get them electrocuted by an electrical discharge. Moreover, There are several parameters that affect the selectivity of electrical insecticide such as: the light, the most efficient, the inter electrode distance, where the insect is exterminated, and the electric current that passes through the insect’s body. In this paper, a simulation study was carried out concerning the distribution of the electric field between two electrodes in presence of particle conductor while focusing on the different body sizes. On the other hand, an experimental study was conducted on live locusts to determine the effect of electrical current on insect’s body taking into account the voltage and frequency. Finally, the results are discussed and analyzed in this paper.
- 1 June 2019
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 9 (3)
Open AccessParameters affecting the selectivity of an electrical insecticide
Using an electrical approach in the field of agriculture can be considered as one of the solutions in order to control harmful flying insects. This technique is based on the use of a bio and selective electrical insecticide whose principle consists in attracting insects by the light then get them electrocuted by an electrical discharge. Moreover, There are several parameters that affect the selectivity of electrical insecticide such as: the light, the most efficient, the inter electrode distance, where the insect is exterminated, and the electric current that passes through the insect’s body. In this paper, a simulation study was carried out concerning the distribution of the electric field between two electrodes in presence of particle conductor while focusing on the different body sizes. On the other hand, an experimental study was conducted on live locusts to determine the effect of electrical current on insect’s body taking into account the voltage and frequency. Finally, the results are discussed and analyzed in this paper.
- 1 June 2019
- Published by Elsevier in Electric Power Systems Research
- Vol. 171, 15-25
A cost comparison of metallic and earth return path for HVDC transmission System case study: connection Algeria-Europe
- 1 June 2019
- Published by Elsevier in Electric Power Systems Research
- Vol. 171, 15-25
A cost comparison of metallic and earth return path for HVDC transmission System case study: connection Algeria-Europe
- 1 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Computing Coaxial Cable Capacitance through a DC and AC Power Supply
The aim of the present paper is to show the way of computing the Maxwell capacitance when applying a DC & AC voltage and comparing it with the analytic equation given in literature and show the advantages of this numerical method over analytical solution by changing the nature of the dielectric from air to PTFE. So, we will see the influence of the dielectric constant into calculating the capacitor and the impedance. In the case of applying an AC voltage, we vary the power supply frequency from 50 Hz to 1 kHz, 1 kHz - 1 MHz, 1 MHz - 5 MHz.
- 1 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Computing Coaxial Cable Capacitance through a DC and AC Power Supply
The aim of the present paper is to show the way of computing the Maxwell capacitance when applying a DC & AC voltage and comparing it with the analytic equation given in literature and show the advantages of this numerical method over analytical solution by changing the nature of the dielectric from air to PTFE. So, we will see the influence of the dielectric constant into calculating the capacitor and the impedance. In the case of applying an AC voltage, we vary the power supply frequency from 50 Hz to 1 kHz, 1 kHz - 1 MHz, 1 MHz - 5 MHz.
- 28 September 2018
- Published by Springer Nature
- p. 476-486
New Smart Power Management Hybrid System Photovoltaic-Fuel Cell
- 28 September 2018
- Published by Springer Nature
- p. 476-486
New Smart Power Management Hybrid System Photovoltaic-Fuel Cell
- 4 April 2018
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 57 (5)
Density evaluation of remotely-supplied hydrogen radicals produced via tungsten filament method for SiCl 4 reduction
Effect of the hydrogen radical on the reduction of a silicon tetrachloride (SiCl 4 ) source was studied. The hydrogen radicals were generated using a tungsten (W) filament in a generation chamber, and were remotely supplied to another reaction chamber. The density of the hydrogen radical was estimated from the optical transmittance of 600-nm-wavelength light through phosphate glass doped with tungsten oxide (WO 3 ). Lifetime of the hydrogen radical seemed sufficiently long, and its density as supplied to the reaction chamber was estimated to be on the order of 10 12 cm −3 . Signal intensity of the peak corresponding to SiCl 4 ( m / z = 170) detected by quadrupole-mass measurement was confirmed to decrease owing to the reaction with the remotely-supplied hydrogen radical. This indicates the possibility that chemically-stable SiCl 4 , as one of the by-products of the Siemens process, can be reduced to produce silicon.
- 4 April 2018
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 57 (5)
Density evaluation of remotely-supplied hydrogen radicals produced via tungsten filament method for SiCl 4 reduction
Effect of the hydrogen radical on the reduction of a silicon tetrachloride (SiCl 4 ) source was studied. The hydrogen radicals were generated using a tungsten (W) filament in a generation chamber, and were remotely supplied to another reaction chamber. The density of the hydrogen radical was estimated from the optical transmittance of 600-nm-wavelength light through phosphate glass doped with tungsten oxide (WO 3 ). Lifetime of the hydrogen radical seemed sufficiently long, and its density as supplied to the reaction chamber was estimated to be on the order of 10 12 cm −3 . Signal intensity of the peak corresponding to SiCl 4 ( m / z = 170) detected by quadrupole-mass measurement was confirmed to decrease owing to the reaction with the remotely-supplied hydrogen radical. This indicates the possibility that chemically-stable SiCl 4 , as one of the by-products of the Siemens process, can be reduced to produce silicon.
- 1 February 2018
- Published by Springer Nature
- p. 37-58
Desalination in Algeria: Current State and Recommendations for Future Projects
- 1 February 2018
- Published by Springer Nature
- p. 37-58
Desalination in Algeria: Current State and Recommendations for Future Projects