Daniel Oravec
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daniel Oravec has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Yener N. Yeni
Bone and Joint Center, Henry Ford Health, Detroit, USA
3 shared publications - Joshua Drost
Bone & Joint Center, Henry Ford Hospital Integrative Biosciences Center (iBio) , 6135 Woodward, Detroit, MI 48202
2 shared publications - Michael J. Flynn
Department of Radiology, Henry Ford Hospital, 2799 West Grand Blvd, Detroit, MI, 48202, USA
2 shared publications - Roger Zauel
Bone & Joint Center, Henry Ford Health, Detroit, MI, USA
2 shared publications - George Divine
Department of Public Health Sciences, Henry Ford Health, Detroit, MI
1 shared publication Razeen Zaman
Bone and Joint Center, Department of Orthopedic Surgery, Henry Ford Health, Detroit, MI, USA
1 shared publication
Latest Publications
- 22 February 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 183, 112596
Facet joint distance measurement using digital tomosynthesis while standing
- 22 February 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 183, 112596
Facet joint distance measurement using digital tomosynthesis while standing
- 5 December 2022
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 145 (4)
Stiffness and Strain Properties Derived From Digital Tomosynthesis-Based Digital Volume Correlation Predict Vertebral Strength Independently From Bone Mineral Density
Vertebral fractures are the most common osteoporotic fractures, but their prediction using standard bone mineral density (BMD) measurements from dual energy X-ray absorptiometry (DXA) is limited in accuracy. Stiffness, displacement, and strain distribution properties derived from digital tomosynthesis-based digital volume correlation (DTS-DVC) have been suggested as clinically measurable metrics of vertebral bone quality. However, the extent to which these properties correlate to vertebral strength is unknown. To establish this relationship, two independent experiments, one examining isolated T11 and the other examining L3 vertebrae within the L2–L4 segments from cadaveric donors were utilized. Following DXA and DTS imaging, the specimens were uniaxially compressed to fracture. BMD, bone mineral content (BMC), and bone area were recorded for the anteroposterior and lateromedial views from DXA, stiffness, endplate to endplate displacement and distribution statistics of intravertebral strains were calculated from DTS-DVC and vertebral strength was measured from mechanical tests. Regression models were used to examine the relationships of strength with the other variables. Correlations of BMD with vertebral strength varied between experimental groups (R2adj = 0.19–0.78). DTS-DVC derived properties contributed to vertebral strength independently from BMD measures (increasing R2adj to 0.64–0.95). DTS-DVC derived stiffness was the best single predictor (R2adj = 0.66, p < 0.0001) and added the most to BMD in models of vertebral strength for pooled T11 and L3 specimens (R2adj = 0.95, p < 0.0001). These findings provide biomechanical relevance to DTS-DVC calculated properties of vertebral bone and encourage further efforts in the development of the DTS-DVC approach as a clinical tool.
- 5 December 2022
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 145 (4)
Stiffness and Strain Properties Derived From Digital Tomosynthesis-Based Digital Volume Correlation Predict Vertebral Strength Independently From Bone Mineral Density
Vertebral fractures are the most common osteoporotic fractures, but their prediction using standard bone mineral density (BMD) measurements from dual energy X-ray absorptiometry (DXA) is limited in accuracy. Stiffness, displacement, and strain distribution properties derived from digital tomosynthesis-based digital volume correlation (DTS-DVC) have been suggested as clinically measurable metrics of vertebral bone quality. However, the extent to which these properties correlate to vertebral strength is unknown. To establish this relationship, two independent experiments, one examining isolated T11 and the other examining L3 vertebrae within the L2–L4 segments from cadaveric donors were utilized. Following DXA and DTS imaging, the specimens were uniaxially compressed to fracture. BMD, bone mineral content (BMC), and bone area were recorded for the anteroposterior and lateromedial views from DXA, stiffness, endplate to endplate displacement and distribution statistics of intravertebral strains were calculated from DTS-DVC and vertebral strength was measured from mechanical tests. Regression models were used to examine the relationships of strength with the other variables. Correlations of BMD with vertebral strength varied between experimental groups (R2adj = 0.19–0.78). DTS-DVC derived properties contributed to vertebral strength independently from BMD measures (increasing R2adj to 0.64–0.95). DTS-DVC derived stiffness was the best single predictor (R2adj = 0.66, p < 0.0001) and added the most to BMD in models of vertebral strength for pooled T11 and L3 specimens (R2adj = 0.95, p < 0.0001). These findings provide biomechanical relevance to DTS-DVC calculated properties of vertebral bone and encourage further efforts in the development of the DTS-DVC approach as a clinical tool.
- 8 July 2021
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 143 (10)
Assessment of Intravertebral Mechanical Strains and Cancellous Bone Texture Under Load Using a Clinically Available Digital Tomosynthesis Modality
Vertebral fractures are the most common osteoporotic fractures, but clinical means for assessment of vertebral bone integrity are limited in accuracy, as they typically use surrogate measures that are indirectly related to mechanics. The objective of this study was to examine the extent to which intravertebral strain distributions and changes in cancellous bone texture generated by a load of physiological magnitude can be characterized using a clinically available imaging modality. We hypothesized that digital tomosynthesis-based digital volume correlation (DTS-DVC) and image texture-based metrics of cancellous bone microstructure can detect development of mechanical strains under load. Isolated cadaveric T11 vertebrae and L2–L4 vertebral segments were DTS imaged in a nonloaded state and under physiological load levels. Axial strain, maximum principal strain, maximum compressive and tensile principal strains, and von Mises equivalent strain were calculated using the DVC technique. The change in textural parameters (line fraction deviation, anisotropy, and fractal parameters) under load was calculated within the cancellous centrum. The effect of load on measured strains and texture variables was tested using mixed model analysis of variance, and relationships of strain and texture variables with donor age, bone density parameters, and bone size were examined using regression models. Magnitudes and heterogeneity of intravertebral strain measures correlated with applied loading and were significantly different from background noise. Image texture parameters were found to change with applied loading, but these changes were not observed in the second experiment testing L2–L4 segments. DTS-DVC-derived strains correlated with age more strongly than did bone mineral density (BMD) for T11.
- 8 July 2021
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 143 (10)
Assessment of Intravertebral Mechanical Strains and Cancellous Bone Texture Under Load Using a Clinically Available Digital Tomosynthesis Modality
Vertebral fractures are the most common osteoporotic fractures, but clinical means for assessment of vertebral bone integrity are limited in accuracy, as they typically use surrogate measures that are indirectly related to mechanics. The objective of this study was to examine the extent to which intravertebral strain distributions and changes in cancellous bone texture generated by a load of physiological magnitude can be characterized using a clinically available imaging modality. We hypothesized that digital tomosynthesis-based digital volume correlation (DTS-DVC) and image texture-based metrics of cancellous bone microstructure can detect development of mechanical strains under load. Isolated cadaveric T11 vertebrae and L2–L4 vertebral segments were DTS imaged in a nonloaded state and under physiological load levels. Axial strain, maximum principal strain, maximum compressive and tensile principal strains, and von Mises equivalent strain were calculated using the DVC technique. The change in textural parameters (line fraction deviation, anisotropy, and fractal parameters) under load was calculated within the cancellous centrum. The effect of load on measured strains and texture variables was tested using mixed model analysis of variance, and relationships of strain and texture variables with donor age, bone density parameters, and bone size were examined using regression models. Magnitudes and heterogeneity of intravertebral strain measures correlated with applied loading and were significantly different from background noise. Image texture parameters were found to change with applied loading, but these changes were not observed in the second experiment testing L2–L4 segments. DTS-DVC-derived strains correlated with age more strongly than did bone mineral density (BMD) for T11.