TKTatyana P. Koretskaya

Tatyana P. Koretskaya

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tatyana P. Koretskaya has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Vapor-Phase-Deposited Ag/Ir and Ag/Au Film Heterostructures for Implant Materials: Cytotoxic, Antibacterial and Histological Studies

    by David S. Sergeevichev, Svetlana I. Dorovskikh, Evgeniia S. Vikulova, Elena V. Chepeleva, Maria B. Vasiliyeva, Tatiana P. Koretskaya, Anastasiya D. Fedorenko, Dmitriy A. Nasimov, Tatiana Y. Guselnikova, Pavel S. Popovetsky, et al.

    Using gas-phase deposition (Physical Vapor Deposition (PVD) and Metal Organic Chemical Vapor Deposition (MOCVD)) methods, modern implant samples (Ti alloy and CFR-PEEK polymer, 30% carbon fiber) were functionalized with film heterostructures consisting of an iridium or gold sublayer, on the surface of which an antibacterial component (silver) was deposited: Ag/Ir(Au)/Ti(CFR-PEEK). The biocidal effect of the heterostructures was investigated, the effect of the surface relief of the carrier and the metal sublayer on antibacterial activity was established, and the dynamics of silver dissolution was evaluated. It has been shown that the activity of Ag/Ir heterostructures was due to high Ag+ release rates, which led to rapid (2–4 h) inhibition of P. aeruginosa growth. In the case of Ag/Au type heterostructures, the inhibition of the growth of P. aeruginosa and S. aureus occurred more slowly (from 6 h), and the antibacterial activity appeared to be due to the contribution of two agents (Ag+ and Au+ ions). It was found, according to the in vitro cytotoxicity study, that heterostructures did not exhibit toxic effects (cell viability > 95–98%). An in vivo biocompatibility assessment based on the results of a morphohistological study showed that after implantation for a period of 30 days, the samples were characterized by the presence of a thin fibrous capsule without volume thickening and signs of inflammation.


  • Open Access

    Application of Biocompatible Noble Metal Film Materials to Medical Implants: TiNi Surface Modification

    by Evgeniia S. Vikulova, Ksenya I. Karakovskaya, Ilya V. Korolkov, Tatyana P. Koretskaya, Elena V. Chepeleva, Nikolay B. Kuz’min, Anastasiya D. Fedorenko, Denis P. Pischur, Tatiana Ya. Guselnikova, Eugene A. Maksimovskii, et al.

    Recently, film materials based on the combination of noble metals have showed promising results for surface modification of medical implants, allowing both to improve biocompatibility and to acquire the increased antibacterial effect. An important challenge here is to combine the developed coating morphology, which is favorable for biological response, with a high protective function, which, on the contrary, requires a compact coating microstructure. In this work, we aimed to solve this problem with respect to the TiNi implant material. We have tested two types of compact thin sublayers: Iridium (Ir’), formed by metal-organic chemical vapor deposition (MOCVD), and gold (Au), formed by physical vapor deposition (PVD). Subsequently these sublayers were coated with a developed-columnar-iridium (Ir) by MOCVD. Features of the microstructure, chemical and phase composition of all these film materials were studied using powder X-ray diffraction (XRD), scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The changes in the characteristics of TiNi martensitic transformation due to MOCVD experiments were also studied by differential scanning calorimetry (DSC). The biocompatibility of Ir’/TiNi, Au/TiNi, Ir/Ir’/TiNi, Ir/Au/TiNi samples was assessed by cytoxicity testing (Man-1 cells) and measuring of nickel content in the biological extracts. The application of both sublayers effectively reduces the release of nickel, which was previously shown for Ir/TiNi samples. This prevents the toxic effect. Note that the Ir’ sublayer better protects against nickel release, while the Au sublayer promotes cell proliferation.


  • Open Access

    MOCVD of Noble Metal Film Materials for Medical Implants: Microstructure and Biocompatibility of Ir and Au/Ir Coatings on TiNi

    by Evgeniia S. Vikulova, Ksenya I. Karakovskaya, Tatyana P. Koretskaya, Ilya V. Korolkov, Elena V. Chepeleva, Igor P. Asanov, Alphiya R. Tsygankova, Eugene A. Maksimovskii, Ekaterina S. Marchenko, Yuriy A. Lantsukhay, et al.

    Noble metals such as Ir, Pt, Au are promising as coatings for metal medical implants to improve biocompatibility and corrosion resistance. Moreover, these coatings can be used as a basis for the further formation of bimetallic hetero-structures with enhanced antibacterial properties. In this work, we develop an approach to obtain such coatings by metal-organic chemical vapor deposition (MOCVD). We have been focused on the formation of Ir coating with developed morphology and subsequent discrete Au coating onto the titanium nickelide (TiNi) implant material. Iridium was deposited in an oxidizing atmosphere from the volatile precursor [Ir(cod)(acac)] (cod = cyclooctadiene-1,5, acac = acetylacetonate-anion). The effects of the deposition temperature (290–350 °C) and amount of introduced oxygen on the composition (Ir, Ir + IrO2) and microstructure of the samples were studied. Hetero-metallic Au/Ir coatings were obtained using [(CH3)2Au(thd)] precursor (thd = dpm = dipivaloylmethanate-anion) at a deposition temperature of 240 °C in the presence of oxygen. To assess the biocompatibility, the toxicity of Ir/TiNi, Au/Ir/TiNi, and uncoated TiNi in relation to human embryonic stem cell line Man-1 was examined after 1, 3, and 5 days of incubation. The results obtained were explained based on the coating microstructures.