Monika Figiela
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Monika Figiela has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Marcin Wysokowski
Institute of Chemical Technology and Engineering, Faculty of Chemical Technology, Poznan University of Technology, Poznań, Poland
2 shared publications Bing‐Jie Ni
Centre for Technology in Water and Wastewater (CTWW) School of Civil and Environmental Engineering University of Technology Sydney (UTS) Ultimo NSW, 2007 Australia
1 shared publicationDerek Hao
Centre for Technology in Water and Wastewater (CTWW) School of Civil and Environmental Engineering University of Technology Sydney (UTS) Ultimo NSW, 2007 Australia
1 shared publicationEwa Stanisz
Institute of Chemistry and Applied Electrochemistry Faculty of Chemical Technology Poznan University of Technology Berdychowo 4 PL-60965 Poznan Poland
1 shared publication- Izabela Stepniak
Institute of Chemistry, Poznań University of Technology, PL-60 965 Poznań, Poland
1 shared publication - Maciej Galinski
Institute of Chemistry and Electrochemistry, Faculty of Chemical Technology, Poznan University of Technology, Berdychowo 4, 60-965 Poznan, Poland
1 shared publication
Latest Publications
- 26 April 2022
- Published by Wiley in Electroanalysis
- Vol. 34 (11) , 1725-1734
Highly Sensitive, Fast Response and Selective Glucose Detection Based on CuO/Nitrogen‐doped Carbon Non‐enzymatic Sensor
This work presents development of an innovative CuO/nitrogen‐doped carbon composite (CuO−C) that may be effectively applied for the modification of a glassy carbon electrode (GCE) and creation of a non‐enzymatic sensor for glucose detection. The structure of the CuO−C nanostructured material was analyzed by scanning electron microscopy, Fourier transform infrared spectroscopy, X‐ray diffraction, and atomic absorption spectroscopy. The prepared electroactive material, based on CuO including carbon structures derived from chitosan, showed excellent performance in terms of electrocatalytic oxidation of glucose. Under optimal conditions, the modified electrode displays high sensitivity (1546 μA mM−1 cm−2), a low detection limit (1.95 μM) and short response time (4 s).
- 26 April 2022
- Published by Wiley in Electroanalysis
- Vol. 34 (11) , 1725-1734
Highly Sensitive, Fast Response and Selective Glucose Detection Based on CuO/Nitrogen‐doped Carbon Non‐enzymatic Sensor
This work presents development of an innovative CuO/nitrogen‐doped carbon composite (CuO−C) that may be effectively applied for the modification of a glassy carbon electrode (GCE) and creation of a non‐enzymatic sensor for glucose detection. The structure of the CuO−C nanostructured material was analyzed by scanning electron microscopy, Fourier transform infrared spectroscopy, X‐ray diffraction, and atomic absorption spectroscopy. The prepared electroactive material, based on CuO including carbon structures derived from chitosan, showed excellent performance in terms of electrocatalytic oxidation of glucose. Under optimal conditions, the modified electrode displays high sensitivity (1546 μA mM−1 cm−2), a low detection limit (1.95 μM) and short response time (4 s).
- 1 November 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 272, 296-307
Synthesis and characterization of novel copper oxide-chitosan nanocomposites for non-enzymatic glucose sensing
- 1 November 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 272, 296-307
Synthesis and characterization of novel copper oxide-chitosan nanocomposites for non-enzymatic glucose sensing