Viktor Reshetnik
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Viktor Reshetnik has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Victoriia Alekseeva
Kharkiv National Medical University, Kharkiv, Ukraine
3 shared publications Alina Nechyporenko
2 shared publications- Alina Nechyporenko
Technical University of Applied Sciences Wildau image/svg+xml
2 shared publications - Igor Grebennik
Kharkiv National University of Radio Electronics
2 shared publications - Marcus Frohme
Technical University of Applied Sciences Wildau image/svg+xml
2 shared publications Vitaliy Gargin
2 shared publications
Latest Publications
- Open Access
- 30 September 2026
- Published by State Scientific Research Institute of Armament and Military Equipment Testing and Certification in Випробування та сертифікація
- No. 3(13),p. 65-71
AN INFORMATION CRITERION-BASED OPTIMAL TARGET SEARCH METHOD FOR A MULTIFUNCTION PHASED RADAR ARRAY IN OPEN ARCHITECTURE AIR DEFENSE SYSTEMS
The article considers the problem of optimal control of the air target search mode of a multifunction radar with a phased array antenna in support of open-architecture air defense systems. The relevance of the study is determined by the need for the rational allocation of limited time and energy resources of the radar among surveillance directions under conditions of uncertainty in the air situation and the presence of competing functional modes. An approach to formalizing the space surveillance process is proposed by discretizing it in time and state, whereby the detection area is divided into cells, and the state of each cell is described by the probability of target presence. Within the proposed model, target motion is represented as a discrete dynamic process with a finite number of states, while transitions between cells and the appearance of new targets are taken into account through extrapolated probabilities. The observation process is considered in a probabilistic form, where the radar receives measurements whose probability density depends on whether a target is present or absent in the corresponding cell. The maximization of the mean Shannon information content in observations is used as the optimality criterion, which ensures consistency between the local radar performance indicator and the overall effectiveness of the air defense system. The main control parameters of the radar’s energy resources in the search mode are determined, including the duration of probing pulses and the number of integrated pulses, and constraints on their use are formulated. These constraints reflect the limited number of angular directions that can be served during one observation step and the total energy resource allocated to the surveillance cycle. To solve the optimal control problem, the discrete form of Pontryagin’s maximum principle is applied, which makes it possible to determine the sequence of cell surveillance in the detection area while taking into account the expected information gain. Since the resulting optimization problem nonlinear and high-dimensional, the computational procedure is based on a method of successive approximations with iterative refinement of the admissible control plan. An algorithm for the computational implementation of the method has been developed. It uses an iterative procedure for forming the control matrix and ensures the selection of a surveillance plan that maximizes the amount of information under given resource constraints. The algorithm provides a practical basis for calculating the optimal sequence of radar observations when only one cell or a limited number of cells can be inspected at each discrete time step. The proposed method can be used to improve the efficiency of searching for and detecting air targets, as well as to develop algorithms for adaptive resource allocation in modern multifunction radar systems. Further research may include simulation modelling of the proposed method in realistic air-target search scenarios and comparison with conventional cyclic surveillance strategies.
- 30 September 2026
- Published by State Scientific Research Institute of Armament and Military Equipment Testing and Certification in Випробування та сертифікація
- No. 3(13),p. 65-71
Open AccessAN INFORMATION CRITERION-BASED OPTIMAL TARGET SEARCH METHOD FOR A MULTIFUNCTION PHASED RADAR ARRAY IN OPEN ARCHITECTURE AIR DEFENSE SYSTEMS
The article considers the problem of optimal control of the air target search mode of a multifunction radar with a phased array antenna in support of open-architecture air defense systems. The relevance of the study is determined by the need for the rational allocation of limited time and energy resources of the radar among surveillance directions under conditions of uncertainty in the air situation and the presence of competing functional modes. An approach to formalizing the space surveillance process is proposed by discretizing it in time and state, whereby the detection area is divided into cells, and the state of each cell is described by the probability of target presence. Within the proposed model, target motion is represented as a discrete dynamic process with a finite number of states, while transitions between cells and the appearance of new targets are taken into account through extrapolated probabilities. The observation process is considered in a probabilistic form, where the radar receives measurements whose probability density depends on whether a target is present or absent in the corresponding cell. The maximization of the mean Shannon information content in observations is used as the optimality criterion, which ensures consistency between the local radar performance indicator and the overall effectiveness of the air defense system. The main control parameters of the radar’s energy resources in the search mode are determined, including the duration of probing pulses and the number of integrated pulses, and constraints on their use are formulated. These constraints reflect the limited number of angular directions that can be served during one observation step and the total energy resource allocated to the surveillance cycle. To solve the optimal control problem, the discrete form of Pontryagin’s maximum principle is applied, which makes it possible to determine the sequence of cell surveillance in the detection area while taking into account the expected information gain. Since the resulting optimization problem nonlinear and high-dimensional, the computational procedure is based on a method of successive approximations with iterative refinement of the admissible control plan. An algorithm for the computational implementation of the method has been developed. It uses an iterative procedure for forming the control matrix and ensures the selection of a surveillance plan that maximizes the amount of information under given resource constraints. The algorithm provides a practical basis for calculating the optimal sequence of radar observations when only one cell or a limited number of cells can be inspected at each discrete time step. The proposed method can be used to improve the efficiency of searching for and detecting air targets, as well as to develop algorithms for adaptive resource allocation in modern multifunction radar systems. Further research may include simulation modelling of the proposed method in realistic air-target search scenarios and comparison with conventional cyclic surveillance strategies.
- 5 October 2024
- Published by Academy of Cognitive and Natural Sciences
- p. 222-228
Uncertainty Estimation Method for Determining Bone Density in Patients with Infiltrating Intraductal Carcinoma Undergoing Anti-Cancer Therapy
Identification of a bone density is crucial in all branches of medicine. Assessing bone density is a labor- intensive process. Bone density is quite unstable and depends on many factors, both physiological (aging, hormonal balance) and pathological (medication use, various underlying conditions). The aim of our study is to determine bone density in patients with malignant breast tumors undergoing anti-cancer therapy. Material and Methods. The study included 50 women aged 60-70 years who were diagnosed with infiltrating intraductal carcinoma. According to established protocols, MSCT is recommended for this category of women at intervals of once every six months. The first MSCT scan was performed immediately after the diagnosis was made, before the start of treatment, and the second scan was conducted six months later. Results. The maximum radiological density was 75.8954±37.9477 Hu in the group of women who had been receiving treatment for six months, compared to 93.9388±46.9694 Hu in the group of patients who did not take the drug. Meanwhile, the minimum density showed a slight increase from 29.7295±14.8647 Hu to 38.6919±19.3460 Hu, which can be attributed to the compensatory mechanisms of the body. Conclusions. In the course of this study, bone density in patients with infiltrating intraductal carcinoma undergoing anti-cancer therapy was determined using uncertainty estimation. It was found that after six months, the first to respond to changes in density was the maximum bone density.
- 5 October 2024
- Published by Academy of Cognitive and Natural Sciences
- p. 222-228
Uncertainty Estimation Method for Determining Bone Density in Patients with Infiltrating Intraductal Carcinoma Undergoing Anti-Cancer Therapy
Identification of a bone density is crucial in all branches of medicine. Assessing bone density is a labor- intensive process. Bone density is quite unstable and depends on many factors, both physiological (aging, hormonal balance) and pathological (medication use, various underlying conditions). The aim of our study is to determine bone density in patients with malignant breast tumors undergoing anti-cancer therapy. Material and Methods. The study included 50 women aged 60-70 years who were diagnosed with infiltrating intraductal carcinoma. According to established protocols, MSCT is recommended for this category of women at intervals of once every six months. The first MSCT scan was performed immediately after the diagnosis was made, before the start of treatment, and the second scan was conducted six months later. Results. The maximum radiological density was 75.8954±37.9477 Hu in the group of women who had been receiving treatment for six months, compared to 93.9388±46.9694 Hu in the group of patients who did not take the drug. Meanwhile, the minimum density showed a slight increase from 29.7295±14.8647 Hu to 38.6919±19.3460 Hu, which can be attributed to the compensatory mechanisms of the body. Conclusions. In the course of this study, bone density in patients with infiltrating intraductal carcinoma undergoing anti-cancer therapy was determined using uncertainty estimation. It was found that after six months, the first to respond to changes in density was the maximum bone density.
- 5 October 2024
- Published by Academy of Cognitive and Natural Sciences
- p. 238-244
Evaluation of Bone Radiodensity in Smokers
One of the most prevalent harmful habits that affect people daily is smoking. The aim of our study was to investigate changes in the bone density of the human paranasal sinuses under the influence of smoking using uncertainty calculation. Material and Methods. The study involved 150 male and female individuals aged 20-40 years, which helps to exclude other factors that could influence the reduction in bone radiodensity (e.g., menopause in women, age-related changes, etc.). The participants were divided into three groups based on the duration of their smoking habits. Results. Smoking has almost no effect on the maximum bone density. All groups show nearly identical values. In the first group, consisting of individuals who smoked for up to 5 years, the maximum density is 75.22 ± 37.61 Hu. In the second group, those who smoked for up to 10 years have a density of 84.22 ± 42.11 Hu, while in the third control group, the density is 74.29 ± 37.15 Hu. On the other hand, smoking has a greater impact on the minimum radiological bone density of the upper wall of the maxillary sinus. The lowest values are found in the group of individuals who smoked for 10 or more years, with a minimum density of 23.86 ± 11.93 Hu. For those who smoked for up to 5 years, the radiological bone density was 52.65 ± 26.32 Hu. In the control group, the density values were slightly higher than those of individuals who smoked for up to 5 years, with the highest values being 58.12 ± 29.06 Hu. Conclusion. The study investigated changes in the bone density of the human paranasal sinuses under the influence of smoking, utilizing uncertainty calculation. It was found that the most sensitive indicator to nicotine exposure is the minimum radiological density, which can significantly increase the risk of developing complications. Specifically, the lowest radiological density was observed in the group of individuals who smoked for 10 years or more, with a value of 23.86 ± 11.93 Hu.
- 5 October 2024
- Published by Academy of Cognitive and Natural Sciences
- p. 238-244
Evaluation of Bone Radiodensity in Smokers
One of the most prevalent harmful habits that affect people daily is smoking. The aim of our study was to investigate changes in the bone density of the human paranasal sinuses under the influence of smoking using uncertainty calculation. Material and Methods. The study involved 150 male and female individuals aged 20-40 years, which helps to exclude other factors that could influence the reduction in bone radiodensity (e.g., menopause in women, age-related changes, etc.). The participants were divided into three groups based on the duration of their smoking habits. Results. Smoking has almost no effect on the maximum bone density. All groups show nearly identical values. In the first group, consisting of individuals who smoked for up to 5 years, the maximum density is 75.22 ± 37.61 Hu. In the second group, those who smoked for up to 10 years have a density of 84.22 ± 42.11 Hu, while in the third control group, the density is 74.29 ± 37.15 Hu. On the other hand, smoking has a greater impact on the minimum radiological bone density of the upper wall of the maxillary sinus. The lowest values are found in the group of individuals who smoked for 10 or more years, with a minimum density of 23.86 ± 11.93 Hu. For those who smoked for up to 5 years, the radiological bone density was 52.65 ± 26.32 Hu. In the control group, the density values were slightly higher than those of individuals who smoked for up to 5 years, with the highest values being 58.12 ± 29.06 Hu. Conclusion. The study investigated changes in the bone density of the human paranasal sinuses under the influence of smoking, utilizing uncertainty calculation. It was found that the most sensitive indicator to nicotine exposure is the minimum radiological density, which can significantly increase the risk of developing complications. Specifically, the lowest radiological density was observed in the group of individuals who smoked for 10 years or more, with a value of 23.86 ± 11.93 Hu.
- 15 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 53-56
Placement of Different Types Containers at Railway Container Terminal Using Double-Stack
There are various problems in optimizing container operations during container service at the rail container terminal. The problem of movement optimization for different types of containers at the railway container terminal with using double-stack loading is formulated. An approach to improve the efficiency of container handling operations at the railway terminal is proposed. According to the approach, the placement of containers on railway platforms and in the storage area at the railway terminal is optimized. The mathematical model in the form of a combinatorial optimization problem is constructed; a strategy for solving the problem is formulated. Examples of efficiency calculations of containers reloading operations by the proposed approach are resulted.
- 15 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 53-56
Placement of Different Types Containers at Railway Container Terminal Using Double-Stack
There are various problems in optimizing container operations during container service at the rail container terminal. The problem of movement optimization for different types of containers at the railway container terminal with using double-stack loading is formulated. An approach to improve the efficiency of container handling operations at the railway terminal is proposed. According to the approach, the placement of containers on railway platforms and in the storage area at the railway terminal is optimized. The mathematical model in the form of a combinatorial optimization problem is constructed; a strategy for solving the problem is formulated. Examples of efficiency calculations of containers reloading operations by the proposed approach are resulted.
- 6 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 407-411
Comparative Characteristics of the Anatomical Structures of the Ostiomeatal Complex Obtained by 3D Modeling
Today 3D modeling with AI involvement is a promising direction in all branches of science, in particular in medicine and especially in otolaryngology. The study involved 100 subjects without any abnormalities of the ENT organs. The main anatomical structures of the ostiomeatal complex, the sizes of which were determined, were the uncinated process, the middle nasal concha and the natural anastomosis between the nasal cavity and the anterior group of the paranasal sinuses. On the basis of the study, it can be assumed that the structure of the ostiomeatal complex components during 3D modeling is as close as possible when measured in vivo by means of endoscopic surgical treatment.
- 6 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 407-411
Comparative Characteristics of the Anatomical Structures of the Ostiomeatal Complex Obtained by 3D Modeling
Today 3D modeling with AI involvement is a promising direction in all branches of science, in particular in medicine and especially in otolaryngology. The study involved 100 subjects without any abnormalities of the ENT organs. The main anatomical structures of the ostiomeatal complex, the sizes of which were determined, were the uncinated process, the middle nasal concha and the natural anastomosis between the nasal cavity and the anterior group of the paranasal sinuses. On the basis of the study, it can be assumed that the structure of the ostiomeatal complex components during 3D modeling is as close as possible when measured in vivo by means of endoscopic surgical treatment.
- 1 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 460-463
Implementation and analysis of uncertainty of measurement results for lower walls of maxillary and frontal sinuses
Uncertainty of Measurement is a parameter associated with the result of the study, characterizing the entire range of values that could reasonably be attributed to this indicator. It helps to unify the process of processing medical data, analyze this data, and obtain new important information based on the findings. The anatomical structure of the paranasal sinuses was studied using spiral computed tomography. Today, computed tomography is the “gold standard” for diagnosing rhinosinusitis. The purpose of our study was the Analysis of Uncertainty of Measurement Results for Anatomical Images obtained in the SCT study of PNSs in physiological conditions and in varying degrees of severity of pathological processes. The study comprises the assessment of Spiral computed tomograms (coronary sections). To measure uncertainty, the maximum and minimum value of each indicator was calculated. Thus, in order to optimize the study of the anatomy of the paranasal sinuses according to the spiral computed tomography findings, it is reasonable to apply the method of calculating uncertainty.
- 1 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 460-463
Implementation and analysis of uncertainty of measurement results for lower walls of maxillary and frontal sinuses
Uncertainty of Measurement is a parameter associated with the result of the study, characterizing the entire range of values that could reasonably be attributed to this indicator. It helps to unify the process of processing medical data, analyze this data, and obtain new important information based on the findings. The anatomical structure of the paranasal sinuses was studied using spiral computed tomography. Today, computed tomography is the “gold standard” for diagnosing rhinosinusitis. The purpose of our study was the Analysis of Uncertainty of Measurement Results for Anatomical Images obtained in the SCT study of PNSs in physiological conditions and in varying degrees of severity of pathological processes. The study comprises the assessment of Spiral computed tomograms (coronary sections). To measure uncertainty, the maximum and minimum value of each indicator was calculated. Thus, in order to optimize the study of the anatomy of the paranasal sinuses according to the spiral computed tomography findings, it is reasonable to apply the method of calculating uncertainty.
- 2 October 2019
- Published by Springer Nature
- p. 66-75
Strategy of Effective Decision-Making in Planning and Elimination of Consequences of Emergency Situations
- 2 October 2019
- Published by Springer Nature
- p. 66-75
Strategy of Effective Decision-Making in Planning and Elimination of Consequences of Emergency Situations
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 585-588
Assessment of Measurement Uncertainty of the Uncinated Process and Middle Nasal Concha in Spiral Computed Tomography Data
Ostiomeatal complex is a key anatomical zone that provides physiological functioning of the paranasal sinuses. It is here that such important functions as drainage and ventilation of paranasal sinuses occur. Consequently, the narrowing of this area leads to significant changes in paranasal sinuses with the development of acute and chronic rhinosinusitis. Today, computed tomography is the "gold standard" for diagnosing rhinosinusitis. The purpose of our research was to optimize the study of tomographic images of the anatomical components of the ostiomeatal complex (uncinate process, nasal concha) according to computed tomography analysis. The study comprises the assessment of Spiral computed tomograms (coronary sections). To measure uncertainty, the maximum and minimum value of each indicator was calculated. Thus, in order to optimize the study of the anatomy of the ostiomeatal complex components according to the spiral computed tomography findings, it is reasonable to apply the method of calculating uncertainty.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 585-588
Assessment of Measurement Uncertainty of the Uncinated Process and Middle Nasal Concha in Spiral Computed Tomography Data
Ostiomeatal complex is a key anatomical zone that provides physiological functioning of the paranasal sinuses. It is here that such important functions as drainage and ventilation of paranasal sinuses occur. Consequently, the narrowing of this area leads to significant changes in paranasal sinuses with the development of acute and chronic rhinosinusitis. Today, computed tomography is the "gold standard" for diagnosing rhinosinusitis. The purpose of our research was to optimize the study of tomographic images of the anatomical components of the ostiomeatal complex (uncinate process, nasal concha) according to computed tomography analysis. The study comprises the assessment of Spiral computed tomograms (coronary sections). To measure uncertainty, the maximum and minimum value of each indicator was calculated. Thus, in order to optimize the study of the anatomy of the ostiomeatal complex components according to the spiral computed tomography findings, it is reasonable to apply the method of calculating uncertainty.