Pierre Le Cann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Pierre Le Cann has a total of 170 co-authors. Here are the top co-authors by number of shared publications:
- Estelle Baurès
EHESP School of Public Health, Inserm, Irset (Institut de Recherche en Santé, Environnement et Travail)—UMR_S 1085, Université de Rennes, F-35000 Rennes, France
5 shared publications - Arnaud Florentin
Department of Hygiene, Environmental Risks and Healthcare Associated Risks, University of Lorraine, Vandoeuvre-lès-Nancy, Nancy, France; Université de Lorraine, APEMAC, F-54000, Nancy, France
4 shared publications Jean-Pierre Gangneux
Centre Hospitalier Régional Universitaire de Rennes, 2 Rue Henri le Guilloux, 35000 Rennes, France; Univ Rennes, Irset (Institut de recherche en santé, environnement et travail) - UMR_S 1085, Avenue du professeur Léon Bernard, F 35000 Rennes, France
4 shared publications- Jean-Pierre Gangneux
Centre National de Référence des Mycoses et Antifongiques LA-AspC Aspergilloses Chroniques, ECMM Excellence Center for Medical Mycology, Centre Hospitalier Universitaire de Rennes , Rennes
4 shared publications P. Coursaget
Institute of Virology, School of Pharmacy, Tours, France, and Liver Center, Huntington Memorial Hospital, Pasadena, California, and Abbott Laboratories, Abbott ParkIllinois, USA
4 shared publications- Alexandre Baudet
Université de Lorraine, faculté d'odontologie Vandœuvre‐lès‐Nancy France
3 shared publications
Latest Publications
- 20 January 2026
- Published by Elsevier in Science of The Total Environment
- Vol. 1015, 181408
SVOCs, VOCs and microbiological contamination in sports facilities, what are people exposed to?
- 20 January 2026
- Published by Elsevier in Science of The Total Environment
- Vol. 1015, 181408
SVOCs, VOCs and microbiological contamination in sports facilities, what are people exposed to?
- Open Access
Analysis of Particulate and Microbiological Filtration Performance of Air Handling Unit Filters in a Low-Energy Office Building over 12 Months
Indoor air quality is an important consideration for the health and well-being of building occupants, and the SARS CoV-2 pandemic highlighted the importance of maintaining proper ventilation in buildings. Air handling units (AHUs) are used to provide fresh air and maintain occupant comfort. The objective of this work was to study the evolution of filtration efficiency in an AHU fitted with bag filters, installed to treat office air in a low-energy building, over a 12-month period. The particulate filtration efficiency (PFE) and the microbial filtration efficiency (MFE) were quantified by measuring particle size distribution and bacterial and fungal concentration in the air circulating in the AHU. The resulting microbial concentration measurements in the fresh air (between 10²–103 CFU/m3 for fungi and around 103 CFU/m3 for bacteria) were higher than those in the extracted air from the offices (between 101 and 102 CFU/m3 for fungi and around 102 CFU/m3 for bacteria). The PFE and MFE measured were almost constant throughout the 12 months, with an increase of the filter pressure drop from 70 to 90 Pa. The PFE and MFE were quite comparable for a particle diameter. Therefore, the measurement of PFE is a reliable indicator of the MFE.
Open AccessAnalysis of Particulate and Microbiological Filtration Performance of Air Handling Unit Filters in a Low-Energy Office Building over 12 Months
Indoor air quality is an important consideration for the health and well-being of building occupants, and the SARS CoV-2 pandemic highlighted the importance of maintaining proper ventilation in buildings. Air handling units (AHUs) are used to provide fresh air and maintain occupant comfort. The objective of this work was to study the evolution of filtration efficiency in an AHU fitted with bag filters, installed to treat office air in a low-energy building, over a 12-month period. The particulate filtration efficiency (PFE) and the microbial filtration efficiency (MFE) were quantified by measuring particle size distribution and bacterial and fungal concentration in the air circulating in the AHU. The resulting microbial concentration measurements in the fresh air (between 10²–103 CFU/m3 for fungi and around 103 CFU/m3 for bacteria) were higher than those in the extracted air from the offices (between 101 and 102 CFU/m3 for fungi and around 102 CFU/m3 for bacteria). The PFE and MFE measured were almost constant throughout the 12 months, with an increase of the filter pressure drop from 70 to 90 Pa. The PFE and MFE were quite comparable for a particle diameter. Therefore, the measurement of PFE is a reliable indicator of the MFE.
- Open Access
Quantitative Health Risk Assessment of the Chronic Inhalation of Chemical Compounds in Healthcare and Elderly Care Facilities
Previous studies have described the chemical pollution in indoor air of healthcare and care facilities. From these studies, the main objective of this work was to conduct a quantitative health risk assessment of the chronic inhalation of chemical compounds by workers in healthcare and elderly care facilities (hospitals, dental and general practitioner offices, pharmacies and nursing homes). The molecules of interest were 36 volatile and 13 semi-volatile organic compounds. Several professional exposure scenarios were developed in these facilities. The likelihood and severity of side effects that could occur were assessed by calculating the hazard quotient for deterministic effects, and the excess lifetime cancer risk for stochastic effects. No hazard quotient was greater than 1. Three compounds had a hazard quotient above 0.1: 2-ethyl-1-hexanol in dental and general practitioner offices, ethylbenzene and acetone in dental offices. Only formaldehyde presented an excess lifetime cancer risk greater than 1 × 10−5 in dental and general practitioner offices (maximum value of 3.8 × 10−5 for general practitioners). The health risk for chronic inhalation of most compounds investigated did not appear to be of concern. Some values tend to approach the acceptability thresholds justifying a reflection on the implementation of corrective actions such as the installation of ventilation systems.
Open AccessQuantitative Health Risk Assessment of the Chronic Inhalation of Chemical Compounds in Healthcare and Elderly Care Facilities
Previous studies have described the chemical pollution in indoor air of healthcare and care facilities. From these studies, the main objective of this work was to conduct a quantitative health risk assessment of the chronic inhalation of chemical compounds by workers in healthcare and elderly care facilities (hospitals, dental and general practitioner offices, pharmacies and nursing homes). The molecules of interest were 36 volatile and 13 semi-volatile organic compounds. Several professional exposure scenarios were developed in these facilities. The likelihood and severity of side effects that could occur were assessed by calculating the hazard quotient for deterministic effects, and the excess lifetime cancer risk for stochastic effects. No hazard quotient was greater than 1. Three compounds had a hazard quotient above 0.1: 2-ethyl-1-hexanol in dental and general practitioner offices, ethylbenzene and acetone in dental offices. Only formaldehyde presented an excess lifetime cancer risk greater than 1 × 10−5 in dental and general practitioner offices (maximum value of 3.8 × 10−5 for general practitioners). The health risk for chronic inhalation of most compounds investigated did not appear to be of concern. Some values tend to approach the acceptability thresholds justifying a reflection on the implementation of corrective actions such as the installation of ventilation systems.
- Open Access
Indoor Carbon Dioxide, Fine Particulate Matter and Total Volatile Organic Compounds in Private Healthcare and Elderly Care Facilities
Poor indoor air quality can have adverse effects on human health, especially in susceptible populations. The aim of this study was to measure the concentrations of dioxide carbon (CO2), fine particulate matter (PM2.5) and total volatile organic compounds (TVOCs) in situ in private healthcare and elderly care facilities. These pollutants were continuously measured in two rooms of six private healthcare facilities (general practitioner’s offices, dental offices and pharmacies) and four elderly care facilities (nursing homes) in two French urban areas during two seasons: summer and winter. The mean CO2 concentrations ranged from 764 ± 443 ppm in dental offices to 624 ± 198 ppm in elderly care facilities. The mean PM2.5 concentrations ranged from 13.4 ± 14.4 µg/m3 in dental offices to 5.7 ± 4.8 µg/m3 in general practitioner offices. The mean TVOC concentrations ranged from 700 ± 641 ppb in dental offices to 143 ± 239 ppb in general practitioner offices. Dental offices presented higher levels of indoor air pollutants, associated with the dental activities. Increasing the ventilation of these facilities by opening a window is probably an appropriate method for reducing pollutant concentrations and maintaining good indoor air quality.
Open AccessIndoor Carbon Dioxide, Fine Particulate Matter and Total Volatile Organic Compounds in Private Healthcare and Elderly Care Facilities
Poor indoor air quality can have adverse effects on human health, especially in susceptible populations. The aim of this study was to measure the concentrations of dioxide carbon (CO2), fine particulate matter (PM2.5) and total volatile organic compounds (TVOCs) in situ in private healthcare and elderly care facilities. These pollutants were continuously measured in two rooms of six private healthcare facilities (general practitioner’s offices, dental offices and pharmacies) and four elderly care facilities (nursing homes) in two French urban areas during two seasons: summer and winter. The mean CO2 concentrations ranged from 764 ± 443 ppm in dental offices to 624 ± 198 ppm in elderly care facilities. The mean PM2.5 concentrations ranged from 13.4 ± 14.4 µg/m3 in dental offices to 5.7 ± 4.8 µg/m3 in general practitioner offices. The mean TVOC concentrations ranged from 700 ± 641 ppb in dental offices to 143 ± 239 ppb in general practitioner offices. Dental offices presented higher levels of indoor air pollutants, associated with the dental activities. Increasing the ventilation of these facilities by opening a window is probably an appropriate method for reducing pollutant concentrations and maintaining good indoor air quality.
- Open Access
- 13 October 2021
- Published by MDPI AG in Atmosphere
- Vol. 12 (10) , 1337
Indoor Air Quality in Healthcare and Care Facilities: Chemical Pollutants and Microbiological Contaminants
The indoor air quality of healthcare and care facilities is poorly studied. The aim of this study was to qualitatively and quantitatively describe the chemical pollution and the microbiological contaminations of the indoor environment of these facilities. Methods: A wide range of chemical compounds (39 volatile and 13 semi-volatile organic compounds, carbon dioxide, fine particulate matter) and microorganisms (fungi and bacteria) were studied. Sampling campaigns were conducted in two French cities in summer 2018 and winter 2019 in six private healthcare facilities (general practitioner’s offices, dental offices, pharmacies) and four care facilities (nursing homes). Results: The highest median concentrations of chemical compounds (μg/m3) were measured for alcohols (ethanol: 378.9 and isopropanol: 23.6), ketones (acetone: 18.8), aldehydes (formaldehyde: 11.4 and acetaldehyde: 6.5) and terpenes (limonene: 4.3). The median concentration of PM2.5 was 9.0 µg/m3. The main bacteria of these indoor environments were Staphylococcus, Micrococcus and Bacillus genera, with median bacterial concentrations in the indoor air of 14 cfu/m3. The two major fungal genera were Cladosporium and Penicillium, with median fungal concentrations of 7 cfu/m3. Conclusions: Indoor air in healthcare and care facilities contains a complex mixture of many pollutants found in higher concentrations compared to the indoor air in French hospitals in a previous study.
- 13 October 2021
- Published by MDPI AG in Atmosphere
- Vol. 12 (10) , 1337
Open AccessIndoor Air Quality in Healthcare and Care Facilities: Chemical Pollutants and Microbiological Contaminants
The indoor air quality of healthcare and care facilities is poorly studied. The aim of this study was to qualitatively and quantitatively describe the chemical pollution and the microbiological contaminations of the indoor environment of these facilities. Methods: A wide range of chemical compounds (39 volatile and 13 semi-volatile organic compounds, carbon dioxide, fine particulate matter) and microorganisms (fungi and bacteria) were studied. Sampling campaigns were conducted in two French cities in summer 2018 and winter 2019 in six private healthcare facilities (general practitioner’s offices, dental offices, pharmacies) and four care facilities (nursing homes). Results: The highest median concentrations of chemical compounds (μg/m3) were measured for alcohols (ethanol: 378.9 and isopropanol: 23.6), ketones (acetone: 18.8), aldehydes (formaldehyde: 11.4 and acetaldehyde: 6.5) and terpenes (limonene: 4.3). The median concentration of PM2.5 was 9.0 µg/m3. The main bacteria of these indoor environments were Staphylococcus, Micrococcus and Bacillus genera, with median bacterial concentrations in the indoor air of 14 cfu/m3. The two major fungal genera were Cladosporium and Penicillium, with median fungal concentrations of 7 cfu/m3. Conclusions: Indoor air in healthcare and care facilities contains a complex mixture of many pollutants found in higher concentrations compared to the indoor air in French hospitals in a previous study.
- 4 February 2019
- Published by Springer Nature in Aerobiologia
- Vol. 35 (2) , 357-366
Adenovirus behavior in air handling unit fiberglass filters
Viral aerosols can lead to respiratory viral infections with high infectivity. About 90% of people’s time is spent in closed environments. A few studies have pointed out that the ventilation systems in air handling units (AHUs) that treat and transmit a new synthetic clean and conditioned environment can also spread and transport viral particles in buildings. The aim of this work is to study the characterization of adenovirus, a DNA non-enveloped respiratory virus, on the F7 fiberglass filter used in AHUs. In this study, an experimental setup simulating an AHU was used. The SYBR® QPCR, Electrical Low-Pressure Impactor (ELPI™) and Scanning Mobility Particle Sizer (SMPS™) were used to detect, measure and characterize the aerosolized adenovirus solution. The characterization results showed that the nebulized adenovirus could be aerosolized in different forms associated or not with cell debris and proteins. The quantification and level of infectivity of adenovirus demonstrated that viruses passed through filters and remained infectious up- and downstream of the system during the 25 min of aerosolization. This study showed that AHUs should be considered an indoor source of viral contamination.
- 4 February 2019
- Published by Springer Nature in Aerobiologia
- Vol. 35 (2) , 357-366
Adenovirus behavior in air handling unit fiberglass filters
Viral aerosols can lead to respiratory viral infections with high infectivity. About 90% of people’s time is spent in closed environments. A few studies have pointed out that the ventilation systems in air handling units (AHUs) that treat and transmit a new synthetic clean and conditioned environment can also spread and transport viral particles in buildings. The aim of this work is to study the characterization of adenovirus, a DNA non-enveloped respiratory virus, on the F7 fiberglass filter used in AHUs. In this study, an experimental setup simulating an AHU was used. The SYBR® QPCR, Electrical Low-Pressure Impactor (ELPI™) and Scanning Mobility Particle Sizer (SMPS™) were used to detect, measure and characterize the aerosolized adenovirus solution. The characterization results showed that the nebulized adenovirus could be aerosolized in different forms associated or not with cell debris and proteins. The quantification and level of infectivity of adenovirus demonstrated that viruses passed through filters and remained infectious up- and downstream of the system during the 25 min of aerosolization. This study showed that AHUs should be considered an indoor source of viral contamination.
- 1 November 2018
- Published by Elsevier in Science of The Total Environment
- Vol. 642, 168-179
Indoor air quality in two French hospitals: Measurement of chemical and microbiological contaminants
- 1 November 2018
- Published by Elsevier in Science of The Total Environment
- Vol. 642, 168-179
Indoor air quality in two French hospitals: Measurement of chemical and microbiological contaminants
- 1 October 2017
- Published by Elsevier in Environmental Research
- Vol. 158, 691-702
Granulometry, microbial composition and biological activity of dusts collected in French dairy farms
- 1 October 2017
- Published by Elsevier in Environmental Research
- Vol. 158, 691-702
Granulometry, microbial composition and biological activity of dusts collected in French dairy farms
- 28 June 2017
- Published by Springer Nature in Food and Environmental Virology
- Vol. 9 (4) , 464-472
The Fate of Mengovirus on Fiberglass Filter of Air Handling Units
One of the most important topics that occupy public health problems is the air quality. That is the reason why mechanical ventilation and air handling units (AHU) were imposed by the different governments in the collective or individual buildings. Many buildings create an artificial climate using heating, ventilation, and air-conditioning systems. Among the existing aerosols in the indoor air, we can distinguish the bioaerosol with biological nature such as bacteria, viruses, and fungi. Respiratory viral infections are a major public health issue because they are usually highly infective. We spend about 90% of our time in closed environments such as homes, workplaces, or transport. Some studies have shown that AHU contribute to the spread and transport of viral particles within buildings. The aim of this work is to study the characterization of viral bioaerosols in indoor environments and to understand the fate of mengovirus eukaryote RNA virus on glass fiber filter F7 used in AHU. In this study, a set-up close to reality of AHU system was used. The mengovirus aerosolized was characterized and measured with the electrical low pressure impact and the scanner mobility particle size and detected with RT-qPCR. The results about quantification and the level of infectivity of mengovirus on the filter and in the biosampler showed that mengovirus can pass through the filter and remain infectious upstream and downstream the system. Regarding the virus infectivity on the filter under a constant air flow, mengovirus was remained infectious during 10 h after aerosolization.
- 28 June 2017
- Published by Springer Nature in Food and Environmental Virology
- Vol. 9 (4) , 464-472
The Fate of Mengovirus on Fiberglass Filter of Air Handling Units
One of the most important topics that occupy public health problems is the air quality. That is the reason why mechanical ventilation and air handling units (AHU) were imposed by the different governments in the collective or individual buildings. Many buildings create an artificial climate using heating, ventilation, and air-conditioning systems. Among the existing aerosols in the indoor air, we can distinguish the bioaerosol with biological nature such as bacteria, viruses, and fungi. Respiratory viral infections are a major public health issue because they are usually highly infective. We spend about 90% of our time in closed environments such as homes, workplaces, or transport. Some studies have shown that AHU contribute to the spread and transport of viral particles within buildings. The aim of this work is to study the characterization of viral bioaerosols in indoor environments and to understand the fate of mengovirus eukaryote RNA virus on glass fiber filter F7 used in AHU. In this study, a set-up close to reality of AHU system was used. The mengovirus aerosolized was characterized and measured with the electrical low pressure impact and the scanner mobility particle size and detected with RT-qPCR. The results about quantification and the level of infectivity of mengovirus on the filter and in the biosampler showed that mengovirus can pass through the filter and remain infectious upstream and downstream the system. Regarding the virus infectivity on the filter under a constant air flow, mengovirus was remained infectious during 10 h after aerosolization.