Hussein Ibrahim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hussein Ibrahim has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Alastair Keith Denniston
College of Medicine and Health, University of Birmingham, Birmingham, UK
2 shared publications C. M. Way
Academic Unit of Ophthalmology, Institute of Inflammation and Ageing, University of Birmingham, Birmingham, United Kingdom
1 shared publication- David P. Crabb
City St George's, University of London, Optometry and Visual Sciences, London, United Kingdom
1 shared publication - Giovanni Montesano
NIHR Biomedical Research Centre, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, United Kingdom; City St George's, University of London, Optometry and Visual Sciences, London, United Kingdom
1 shared publication - Giovanni Ometto
Institute of Ophthalmology, UCL, London, UK
1 shared publication - Pearse Andrew Keane
Institute of Ophthalmology, University College London, London, UK
1 shared publication
Latest Publications
- Open Access
- 6 May 2021
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 49 (5) , 470-476
Reporting guidelines for artificial intelligence in healthcare research
Reporting guidelines are structured tools developed using explicit methodology that specify the minimum information required by researchers when reporting a study. The use of artificial intelligence (AI) reporting guidelines that address potential sources of bias specific to studies involving AI interventions has the potential to improve the quality of AI studies, through improvements in their design and delivery, and the completeness and transparency of their reporting. With a number of guidance documents relating to AI studies emerging from different specialist societies, this Review article provides researchers with some key principles for selecting the most appropriate reporting guidelines for a study involving an AI intervention. As the main determinants of a high‐quality study are contained within the methodology of the study design rather than the intervention, researchers are recommended to use reporting guidelines that are specific to the study design, and then supplement them with AI‐specific guidance contained within available AI reporting guidelines.
- 6 May 2021
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 49 (5) , 470-476
Open AccessReporting guidelines for artificial intelligence in healthcare research
Reporting guidelines are structured tools developed using explicit methodology that specify the minimum information required by researchers when reporting a study. The use of artificial intelligence (AI) reporting guidelines that address potential sources of bias specific to studies involving AI interventions has the potential to improve the quality of AI studies, through improvements in their design and delivery, and the completeness and transparency of their reporting. With a number of guidance documents relating to AI studies emerging from different specialist societies, this Review article provides researchers with some key principles for selecting the most appropriate reporting guidelines for a study involving an AI intervention. As the main determinants of a high‐quality study are contained within the methodology of the study design rather than the intervention, researchers are recommended to use reporting guidelines that are specific to the study design, and then supplement them with AI‐specific guidance contained within available AI reporting guidelines.
- Open Access
- 26 January 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1648
Optimizing OCT acquisition parameters for assessments of vitreous haze for application in uveitis
Detection and evaluation of inflammatory activity in uveitis is essential to the management of the condition, and yet continues to be largely dependent on subjective clinical measures. Optical coherence tomography (OCT) measurement of vitreous activity is an alternative to clinical vitreous haze scoring and has passed a number of early validation studies. In this study we aimed to evaluate the impact of ‘operator factors’ on the variability of the technique as part of the validation process, and to help evaluate its suitability for ‘real world’ use. Vitreous haze index was calculated as a ratio between the reflectivity of the vitreous and of the outer retina in each scan. Different scanning conditions were tested and their effect on the measurement is reported. Our results show that the ‘quantitative imaging’ technique of OCT-measured vitreous activity had good reliability in normal subjects under a range of ‘real world’ conditions, such as when the operator changes the averaging value. The technique was however vulnerable to highly inaccurate focussing or abnormal downward displacement of the image. OCT-based quantification of vitreous activity is a promising alternative to current subjective clinical estimates, with sufficient ‘tolerance’ to be used in routine clinical practice as well as clinical trials.
- 26 January 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1648
Open AccessOptimizing OCT acquisition parameters for assessments of vitreous haze for application in uveitis
Detection and evaluation of inflammatory activity in uveitis is essential to the management of the condition, and yet continues to be largely dependent on subjective clinical measures. Optical coherence tomography (OCT) measurement of vitreous activity is an alternative to clinical vitreous haze scoring and has passed a number of early validation studies. In this study we aimed to evaluate the impact of ‘operator factors’ on the variability of the technique as part of the validation process, and to help evaluate its suitability for ‘real world’ use. Vitreous haze index was calculated as a ratio between the reflectivity of the vitreous and of the outer retina in each scan. Different scanning conditions were tested and their effect on the measurement is reported. Our results show that the ‘quantitative imaging’ technique of OCT-measured vitreous activity had good reliability in normal subjects under a range of ‘real world’ conditions, such as when the operator changes the averaging value. The technique was however vulnerable to highly inaccurate focussing or abnormal downward displacement of the image. OCT-based quantification of vitreous activity is a promising alternative to current subjective clinical estimates, with sufficient ‘tolerance’ to be used in routine clinical practice as well as clinical trials.