GDGeydison Gonzaga Demetino

Geydison Gonzaga Demetino

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Geydison Gonzaga Demetino has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Miniaturized Acoustic Sensing Platform for Spatial Mapping of Ultrasonic Fields in Small-Diameter Tube Bundles

    by Luiz Artur dos Santos da Silva, André Jackson Ramos Simões, Vitor Leão Filardi, Vitor Pinheiro Ferreira, Geydison Gonzaga Demetino, Luiz Carlos Simões Soares Júnior, Leandro Do Rozário Teixeira, Lucas Gomes Pereira, Leonardo Rafael Teixeira Cotrim Gomes, Germano Pinto Guedes, et al.

    Shell-and-tube heat exchangers often operate under harsh conditions that induce fouling, leading to loss of thermal efficiency, production downtime, and increased maintenance costs. Conventional cleaning procedures generally require scheduled or unscheduled shutdowns, with direct operational and financial impacts. In this context, ultrasonic cavitation has been investigated as a strategy for fouling prevention and equipment cleaning, with the potential to reduce cleaning downtime or support in-service mitigation strategies. This work presents the development of an acquisition platform based on a miniaturized, waterproof acoustic probe designed for operation inside 8 mm tubes under cavitating ultrasonic fields, with the goal of experimentally mapping the relative acoustic response amplitude and dominant frequency in U-tube heat exchangers. The system integrates a piezoelectric sensing element embedded in protective encapsulation, signal-conditioning electronics, and a high-sampling-rate acquisition module. Experiments were conducted in a reduced-scale exchanger comprising 90 access ports and measurement depths up to 775 mm, using 28 kHz ultrasonic transducers. The probe successfully captured both the spectral content and the spatial variation of the voltage-based acoustic response along the tube bundle, revealing position-dependent amplitude variations and dominant-frequency measurements concentrated around the imposed excitation frequency. The analysis supported the definition of a reduced set of representative sampling locations, decreasing acquisition time while preserving the main spatial trends relevant to the objectives of this study. The procedures established here provide an experimental basis for future studies on the application of ultrasound to fouling-mitigation strategies in industrial thermal systems.

  • Open Access

    High-Speed Microprocessor-Based Optical Instrumentation for the Detection and Analysis of Hydrodynamic Cavitation Downstream of an Additively Manufactured Nozzle

    by Luís Gustavo Macêdo West, André Jackson Ramos Simões, Leandro Do Rozário Teixeira, Lucas Ramalho Oliveira, Juliane Grasiela de Carvalho Gomes, Igor Silva Moreira dos Anjos, Antonio Samuel Bacelar de Freitas Devesa, Leonardo Rafael Teixeira Cotrim Gomes, Lucas Gomes Pereira, Iran Eduardo Lima Neto, et al.

    This study presents the development and validation of a high-speed optical data acquisition system for detecting and characterizing hydrodynamic cavitation downstream of a triangular nozzle. The system integrates a PIN photodiode, a transimpedance amplifier, and a high-sampling-rate microcontroller. Its performance was first evaluated using controlled sinusoidal signals, and statistical stability was assessed as a function of the number of acquired samples. Experiments were subsequently conducted in a converging–diverging conduit under biphasic flow conditions, where mean irradiance, standard deviation, and frequency spectra were analyzed downstream of the nozzle. The optical signal distributions revealed transitions in flow behavior associated with cavitation development, which were quantified through statistical metrics and spectral features. The Strouhal number was estimated from dominant frequencies extracted from the spectra, exhibiting a non-monotonic dependence on the Reynolds number, consistent with changes in flow structure and turbulence intensity. Spectral analysis further indicated frequency bands associated with energy transfer across turbulent scales and bubble dynamics. Overall, the results demonstrate that the proposed optical system constitutes a viable and non-intrusive methodology for detecting and characterizing cavitation intensity in a way that complements other optical and acoustic methods.


  • Open Access

    Experimental and Numerical Analysis of Nozzle-Induced Cavitating Jets: Optical Instrumentation, Pressure Fluctuations and Anisotropic Turbulence Modeling

    by Luís Gustavo Macêdo West, André Jackson Ramos Simões, Leandro Do Rozário Teixeira, Igor Silva Moreira dos Anjos, Antônio Samuel Bacelar de Freitas Devesa, Lucas Ramalho Oliveira, Juliane Grasiela de Carvalho Gomes, Leonardo Rafael Teixeira Cotrim Gomes, Lucas Gomes Pereira, Luiz Carlos Simões Soares Junior, et al.

    Cavitation has been widely explored to enhance physical and chemical processes across various applications. This study aimed to model the key characteristics of a cavitation jet, induced by a triangular-orifice nozzle, using both experimental and numerical methods. Optical instrumentation, a pressure transducer and the Reynolds-Averaged Navier–Stokes (RANS) equations were employed. Optical instrumentation and high-speed photography detected the two-phase flow generated by water vaporization, revealing a mean decay pattern. Irradiance fluctuations and photographic evidence provided results about the light transmission dynamics through cavitating jets. Pressure fluctuations exhibited similar growth and decay, supporting optical instrumentation as a viable method for assessing cavitation intensity. Experimental data showed a strong relationship between irradiance and flow rate (R2 = 0.998). This enabled the correlation of the standard deviation of instantaneous pressure measurements and normalized flow rate (R2 = 0.977). Furthermore, vapor volume fraction and normalized flow rate reached a correlation coefficient of 0.999. On the simulation side, the SSG-RSM turbulence mode showed better agreement with experimental data, with relative deviations ranging from 2.1% to 6.6%. The numerical results suggest that vapor jet length is related to vapor fraction through a power law, enabling the development of new equations. These results demonstrated that anisotropic turbulence modeling is essential to reproduce experimental observations compared to mean flow properties. Based on the agreement between the numerical model and the experimental data for mean flow quantities, a formulation is proposed to estimate the jet length originating from the nozzle, offering a predictive approach for cavitating jet behavior.


  • Calcium carbonate scaling control on heat plate exchange surfaces using ultrasound

    by Lucas Ramalho Oliveira, Lucas Gomes Pereira, Leandro Do Rozário Teixeira, Marcus Vinícius Santos da Silva, Iuri Muniz Pepe, Vítor Pinheiro Ferreira, Luiz Carlos Simões Soares Junior, Geydison Gonzaga Demetino, Fabio Oliveira de Mattos, Andre Luiz Rufino Cordeiro, et al.


  • Large-Scale Pipe Flow Experiments for the Evaluation of Nonchemical Solutions for Calcium Carbonate Scaling Inhibition and Control

    by J. B. R. Loureiro, A. L. Martins, A. S. Gonçalves, B. G. B. Souza, H. E. P. Schluter, H. F. L. Santos, B. B. Castro, I. M. Pepe, L. C. S. Soares Junior, G. G. Demetino, et al.

    Summary: Inorganic scaling is a phenomenon of common occurrence both in nature and in industrial operations. In general, its effects can be highly detrimental for the oil industry, as fouling can take place in different stages of the production, from the wellbore and downhole production control valves to upstream primary oil processing and separation equipment. The deposition of precipitated crystals on pipe walls and valves can result in severe production decline. Despite the high costs involved in the design and operation of separate lines for additive injection, chemical inhibition is typically the solution adopted by the oil companies to mitigate scaling. The purpose of the present work is to show the results of large-scale laboratory pipe flow experiments to evaluate the performance of nonchemical solutions to mitigate and control calcium carbonate scaling. Magnetic, electromagnetic, and ultrasound devices have been tested in a setup that simulates the mixing of two incompatible brine solutions that cause precipitation and deposition of calcium carbonate for a high Reynolds number pipe flow. The performance of the devices is evaluated from pressure drop measurements along the pipe, carbonate deposited mass on the pipe wall, and pipe diameter reduction. Additional results include evaluation of particle-size distribution of precipitated crystals, scanning electron microscopy, X-ray diffraction analysis for identification of the crystalline structure, and pH and conductivity. Results show that the magnetic field furnishes a beneficial effect, as it delays the time observed for the onset of flow restriction in both pipe and valve. The use of a magnetic field slows down scaling, thus delaying the increase in pressure drop. The time scale associated with this delay is of two to four times the required time in tests carried out without a magnetic field. Ultrasound devices are also shown to provide a beneficial impact on the delay of the appearance of scaling effects. An ultrasound field influences the precipitation phenomena, inducing particle sizes to be kept at very small values, an effect that prevents crystal deposition. The main contribution of the present work is to provide an evaluation method of antiscaling devices based on large-scale experiments that are representative of real field applications.


  • Estimating the estate of charge of lead-acid batteries.

    by G.G. Demetino, I. M. Pepe, V. L. Filardi, L. C. S. Soares Júnior, C. E. T. Silva, G. P. Guedes, J. G. Lima Brasílio, D. Rey Rey, A. L. Aguera., J. C. Anjos

    A new system approach for battery discharge to estimate the state of charge of lead-acid batteries has been developed and tested. This new system is based on an industrial network that runs the Modbus Protocol with RTU format. Each unit includes an ID for communication in this network, its own power supply, a stable current supply for battery discharge and its own calibration curve for each channel at the analogical-digital converter. All parameters can be configured by the software supervisor. This system is able to discharge up to 16 batteries simultaneously and save voltage and current values for each unit. All information can be saved into a file that can be read simultaneously to the data acquisition. Thus, it is easier to have it integrated to a database and distributed on to a computing network system. This system will bring more information to the battery ageing estimator, based on the observed voltage distributions over one month. The Pierre Auger Observatory works with different set-ups for the 1600 PV-stand-alone systems. Therefore, a larger scale system capacity to test each battery unit a time has become necessary.

  • Batteries comparison for an optimal accumulation performance on PV isolated systems

    by A.DAniel Rey Rey, A. López Aguera, I.ROdriguez Cabo, E. Vieites Montes, G.G. Demetino, I. Pepe

    The Pierre Auger Project is a macro-grid of 1600 PV identical systems installed on Argentina. Each of this PV is fully monitored. All the data are sent to a central building and recorded for data analysis. In this paper performance of batteries from different manufacturers is studied and compared, trying to find the optimal solution for this experiment, taking in account climate and operation conditions.