Balaji Krishnan
Research Subjects
Balaji Krishnan has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Mahalakshmi Krishnakumaran
Department of Orthodontics, Tagore Dental College and Hospital, Rathinamangalam, Chennai, Tamil Nadu, India
3 shared publications - Annie Shirly Priyanka Gerald
Tagore Dental college and Hospital
1 shared publication - Aswini Soundharya Sekar
Tagore Dental College and Hospital, Clinic of Orthodontics, Chennai, India
1 shared publication - B. Srinivasan
Department of Orthodontics and Dentofacial Orthopedics, Meenakshi Ammal Dental College and Hospital, Alapakkam Main Road, Maduravoyal, Chennai, 600095 India
1 shared publication - C Nirupama
Department of Orthodontics and Dentofacial Orthopedics, Karpaga Vinayaga College of Dental Sciences, Kodambakkam, Chennai, Tamil Nadu, India
1 shared publication - Gowardhan Sivakumar
Postgraduate student, Department of Maxillofacial Prosthodontics, Ragas Dental College and Hospital, Chennai, Tamil Nadu, India
1 shared publication
Latest Publications
- 22 January 2026
- Published by Istanbul University in İstanbul Tıp Fakültesi Dergisi
- Vol. 60 (1) , 338-344
Dimensional accuracy of clear aligners fabricated using different LCD 3D printer resolutions: an in-vitro study
PurposeThe aim of this study is to compare trueness and precision of dental models from three LCD 3D printers with different horizontal resolutions (2K, 4K, 8K) and to evaluate their clinical suitability for orthodontic use.Materials and MethodsThirty models were printed using Creality Halot One (2K), Phrozen Mighty 4K, and Phrozen Mighty 8K printers, with ten models each using manufacturer-recommended resins. Master digital models from intraoral scans were compared to re-scanned printed models through surface superimposition using Geomagic Control X software. Trueness and precision were evaluated by point deviation and Root-Mean-Square (RMS) analysis, with differences assessed by one-way ANOVA (p = 0.05).ResultsMean RMS values for 2K, 4K, and 8K printers were 0.266 ± 0.015 mm, 0.223 ± 0.017 mm, and 0.121 ± 0.012 mm, respectively (p < 0.001). The 8K printer showed highest trueness and precision, with deviations mainly in occlusal and gingival regions. The 0.25 mm error limit was within acceptable range for 4K and 8K models, while 2K models exceeded this value (p < 0.05).ConclusionPrinter resolution significantly affects dimensional accuracy. The 8K LCD printer demonstrated superior accuracy and reproducibility, proving reliable for orthodontic models and clear aligners.
- 22 January 2026
- Published by Istanbul University in İstanbul Tıp Fakültesi Dergisi
- Vol. 60 (1) , 338-344
Dimensional accuracy of clear aligners fabricated using different LCD 3D printer resolutions: an in-vitro study
PurposeThe aim of this study is to compare trueness and precision of dental models from three LCD 3D printers with different horizontal resolutions (2K, 4K, 8K) and to evaluate their clinical suitability for orthodontic use.Materials and MethodsThirty models were printed using Creality Halot One (2K), Phrozen Mighty 4K, and Phrozen Mighty 8K printers, with ten models each using manufacturer-recommended resins. Master digital models from intraoral scans were compared to re-scanned printed models through surface superimposition using Geomagic Control X software. Trueness and precision were evaluated by point deviation and Root-Mean-Square (RMS) analysis, with differences assessed by one-way ANOVA (p = 0.05).ResultsMean RMS values for 2K, 4K, and 8K printers were 0.266 ± 0.015 mm, 0.223 ± 0.017 mm, and 0.121 ± 0.012 mm, respectively (p < 0.001). The 8K printer showed highest trueness and precision, with deviations mainly in occlusal and gingival regions. The 0.25 mm error limit was within acceptable range for 4K and 8K models, while 2K models exceeded this value (p < 0.05).ConclusionPrinter resolution significantly affects dimensional accuracy. The 8K LCD printer demonstrated superior accuracy and reproducibility, proving reliable for orthodontic models and clear aligners.
- Open Access
- 30 December 2025
- Published by Galenos Yayinevi in Turkish Journal of Orthodontics
- Vol. 38 (4) , 216-223
Measurement of Aligner Thickness and Gap Width in Two Types of Clear Aligner Sheets Manufactured Using Two Different Thermoforming Machines - A Nano-CT Pilot Study
Measurement of Aligner Thickness and Gap Width in Two Types of Clear Aligner Sheets Manufactured Using Two Different Thermoforming Machines - A Nano-CT Pilot Study - Turkish Journal of Orthodontics
- 30 December 2025
- Published by Galenos Yayinevi in Turkish Journal of Orthodontics
- Vol. 38 (4) , 216-223
Open AccessMeasurement of Aligner Thickness and Gap Width in Two Types of Clear Aligner Sheets Manufactured Using Two Different Thermoforming Machines - A Nano-CT Pilot Study
Measurement of Aligner Thickness and Gap Width in Two Types of Clear Aligner Sheets Manufactured Using Two Different Thermoforming Machines - A Nano-CT Pilot Study - Turkish Journal of Orthodontics
- Open Access
- 25 March 2018
- Published by Oriental Scientific Publishing Company in Biomedical and Pharmacology Journal
- Vol. 11 (1) , 557-564
Orthodontist’s View on Cerebral Palsy
- 25 March 2018
- Published by Oriental Scientific Publishing Company in Biomedical and Pharmacology Journal
- Vol. 11 (1) , 557-564
Open AccessOrthodontist’s View on Cerebral Palsy
- 1 October 2014
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery, Medicine, and Pathology
- Vol. 26 (4) , 576-579
Double talon cusp associated with synodontia: Report of a rare case and review of the literature
- 1 October 2014
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery, Medicine, and Pathology
- Vol. 26 (4) , 576-579
Double talon cusp associated with synodontia: Report of a rare case and review of the literature
- 1 October 2012
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 13 (5) , 637-643
Comparison of Shear Bond Strength of Hydrophilic Bonding Materials: An in vitro Study
Aim: The aim of this study was to evaluate and compare the shear bond strength of hydrophilic materials like Transbond MIP with Assure-fluoride releasing light cure sealant paste system (Reliance orthodontic product), Enhance Lc-adhesion booster (Reliance Orthodontics) Prime and Bond NT–one step adhesive with nanotechnology (Dentsply Product India) with Transbond XT as the control group. Materials and methods: The study was conducted on 180 extracted human premolar teeth which were divided into five main groups. Each group contained 36 teeth, which were further subdivided into three subgroups containing 12 teeth. The teeth were bonded in three different surface environments namely dry, contaminated with artificial saliva and reprimed after contamination with artificial salvia. The brackets were bonded and cured. The shear bond strength was tested using Instron universal testing machine (4501). Results: The results were subjected to statistical analysis like 3 factorial ANOVA and compared to post-hoc using the Student Newman levels test. The residual resin on the tooth surface after debonding was evaluated with adhesive remnant index. Clinical significance: The results revealed that in situations in which moisture contamination is critical there is distinct advantage in using hydrophilic primers. How to cite this article: Nirupama C, Kavitha S, Jacob J, Balaji K, Srinivasan B, Murugesan R, Krishnaswamy NR. Comparison of Shear Bond Strength of Hydrophilic Bonding Materials: An in vitro Study. J Contemp Dent Pract 2012;13(5): 637-643.
- 1 October 2012
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 13 (5) , 637-643
Comparison of Shear Bond Strength of Hydrophilic Bonding Materials: An in vitro Study
Aim: The aim of this study was to evaluate and compare the shear bond strength of hydrophilic materials like Transbond MIP with Assure-fluoride releasing light cure sealant paste system (Reliance orthodontic product), Enhance Lc-adhesion booster (Reliance Orthodontics) Prime and Bond NT–one step adhesive with nanotechnology (Dentsply Product India) with Transbond XT as the control group. Materials and methods: The study was conducted on 180 extracted human premolar teeth which were divided into five main groups. Each group contained 36 teeth, which were further subdivided into three subgroups containing 12 teeth. The teeth were bonded in three different surface environments namely dry, contaminated with artificial saliva and reprimed after contamination with artificial salvia. The brackets were bonded and cured. The shear bond strength was tested using Instron universal testing machine (4501). Results: The results were subjected to statistical analysis like 3 factorial ANOVA and compared to post-hoc using the Student Newman levels test. The residual resin on the tooth surface after debonding was evaluated with adhesive remnant index. Clinical significance: The results revealed that in situations in which moisture contamination is critical there is distinct advantage in using hydrophilic primers. How to cite this article: Nirupama C, Kavitha S, Jacob J, Balaji K, Srinivasan B, Murugesan R, Krishnaswamy NR. Comparison of Shear Bond Strength of Hydrophilic Bonding Materials: An in vitro Study. J Contemp Dent Pract 2012;13(5): 637-643.