Sergio Antonio Spinola Machado
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sergio Antonio Spinola Machado has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Ivana Cesarino
School of Agriculture, São Paulo State University (UNESP), Botucatu 18610-034, SP, Brazil
3 shared publications - Nathalia Oezau Gomes
São Carlos Institute of Chemistry, University of São Paulo, São Carlos 13566-590, Brazil
3 shared publications Osvaldo N. Oliveira
3 shared publications- Paulo Augusto Raymundo Pereira
São Carlos Institute of Physics, University of São Paulo, CEP, 13560-970 São Carlos, SP, Brazil
3 shared publications Andressa Galli
Universidade de São Paulo, São Carlos
2 shared publications- Cláudia F. B. Coutinho
IQSC-USP
2 shared publications
Latest Publications
- 15 January 2025
- Published by Springer Nature in Brazilian Journal of Microbiology
- Vol. 56 (1) , 275-284
Carbon-dot pequi-nut in the development of immunosensor to detect pathogenic bacteria
Carbon dots in biosensing have advanced significantly, adding improvements to different detection techniques. In this study, an amperometric immunosensor for Salmonella Thyphimurium was designed using antibodies labeled with carbon dots (Cdots) from pequi almond (Caryocar brasiliensis). Cdots were synthesized by pyrolysis and characterized by FTIR, UV/fluorescence, electrochemistry, zeta potential, and transmission electron microscopy (TEM). A particle size of 6.80 ± 2.13 nm was estimated, and the zeta potential was − 47.4 mV, indicating the preponderant presence of acidic groups, as confirmed by FTIR. The impedance evaluation of the response of biosensors assembled for live (Rct = 13.4 kΩ) and dead (Rct = 499.7 Ω) Salmonella showed a significant difference in their values, in agreement with chronoamperometric analyses, which had their current values drastically reduced from − 2.2 mA (live) to 0 mA (dead). An analytical curve for Salmonella was established with the limit of detection lower than 1 CFU/mL. This electrochemical biosensor using pequi carbon dots for antibody labeling showed promising results for detecting the pathogen. Thus, carbon dots can be used as substitutes for enzymes in labeling antibodies used in the design and production of sensors.
- 15 January 2025
- Published by Springer Nature in Brazilian Journal of Microbiology
- Vol. 56 (1) , 275-284
Carbon-dot pequi-nut in the development of immunosensor to detect pathogenic bacteria
Carbon dots in biosensing have advanced significantly, adding improvements to different detection techniques. In this study, an amperometric immunosensor for Salmonella Thyphimurium was designed using antibodies labeled with carbon dots (Cdots) from pequi almond (Caryocar brasiliensis). Cdots were synthesized by pyrolysis and characterized by FTIR, UV/fluorescence, electrochemistry, zeta potential, and transmission electron microscopy (TEM). A particle size of 6.80 ± 2.13 nm was estimated, and the zeta potential was − 47.4 mV, indicating the preponderant presence of acidic groups, as confirmed by FTIR. The impedance evaluation of the response of biosensors assembled for live (Rct = 13.4 kΩ) and dead (Rct = 499.7 Ω) Salmonella showed a significant difference in their values, in agreement with chronoamperometric analyses, which had their current values drastically reduced from − 2.2 mA (live) to 0 mA (dead). An analytical curve for Salmonella was established with the limit of detection lower than 1 CFU/mL. This electrochemical biosensor using pequi carbon dots for antibody labeling showed promising results for detecting the pathogen. Thus, carbon dots can be used as substitutes for enzymes in labeling antibodies used in the design and production of sensors.
- Open Access
- 8 May 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 35 (1) , 18
Biodegradable Mats for the Design of Bifunctional Biosensors for Glucose Detection in Urine
We introduce a bifunctional architecture to construct biosensors on solution-blow spinning fiber mats of polylactic acid (PLA) and polyethylene glycol (PEG). PLA/PEG mats acted as substrate for printing electrodes and as matrix to immobilize glucose oxidase (GOx). Prussian Blue nanoparticles (PB) decorated working electrodes to detect H2O2 from enzymatic catalysis at a low applied potential (0 V vs. Ag/AgCl) with detection limit of 0.197 mM. The inexpensive bifunctional device (<US $0.25 per unit) exhibited a rapid response, long lifetime, and performance similar to the standard method for glucose monitoring in human urine samples. The PLA/PEG mats are sustainable alternative for biosensing and wearable applications.
- 8 May 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 35 (1) , 18
Open AccessBiodegradable Mats for the Design of Bifunctional Biosensors for Glucose Detection in Urine
We introduce a bifunctional architecture to construct biosensors on solution-blow spinning fiber mats of polylactic acid (PLA) and polyethylene glycol (PEG). PLA/PEG mats acted as substrate for printing electrodes and as matrix to immobilize glucose oxidase (GOx). Prussian Blue nanoparticles (PB) decorated working electrodes to detect H2O2 from enzymatic catalysis at a low applied potential (0 V vs. Ag/AgCl) with detection limit of 0.197 mM. The inexpensive bifunctional device (<US $0.25 per unit) exhibited a rapid response, long lifetime, and performance similar to the standard method for glucose monitoring in human urine samples. The PLA/PEG mats are sustainable alternative for biosensing and wearable applications.
- 19 March 2023
- Published by Elsevier in Electrochimica Acta
- Vol. 451, 142271
SARS-CoV-2 detection enabled by a portable and label-free photoelectrochemical genosensor using graphitic carbon nitride and gold nanoparticles
- 19 March 2023
- Published by Elsevier in Electrochimica Acta
- Vol. 451, 142271
SARS-CoV-2 detection enabled by a portable and label-free photoelectrochemical genosensor using graphitic carbon nitride and gold nanoparticles
- 14 December 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 223
Wearable potentiometric biosensor for analysis of urea in sweat
- 14 December 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 223
Wearable potentiometric biosensor for analysis of urea in sweat
- 1 March 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 199, 113875
Wearable sensors made with solution-blow spinning poly(lactic acid) for non-enzymatic pesticide detection in agriculture and food safety
- 1 March 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 199, 113875
Wearable sensors made with solution-blow spinning poly(lactic acid) for non-enzymatic pesticide detection in agriculture and food safety
- 4 February 2022
- Published by Elsevier in Chemical Engineering Journal
- Vol. 435
Wearable glove-embedded sensors for therapeutic drug monitoring in sweat for personalized medicine
- 4 February 2022
- Published by Elsevier in Chemical Engineering Journal
- Vol. 435
Wearable glove-embedded sensors for therapeutic drug monitoring in sweat for personalized medicine
- 26 November 2021
- Published by Springer Nature
- p. 273-282
Electrochemical Methods Applied for Bioanalysis: Differential Pulse Voltammetry and Square Wave Voltammetry
- 26 November 2021
- Published by Springer Nature
- p. 273-282
Electrochemical Methods Applied for Bioanalysis: Differential Pulse Voltammetry and Square Wave Voltammetry
- 1 January 2021
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
- Vol. 32 (10) , 1912-1917
Estimating the Electrochemically Active Area: Revisiting a Basic Concept in Electrochemistry
The well-known electrochemical probe Fe(CN)63-/Fe(CN)64- is widely used for estimating the electrochemically active area of electrodes modified with carbon nanotubes, conductive polymers, enzymes, etc. In this study, we used the platinum electrode, smooth or platinized with different roughness factors, to demonstrate that such a redox couple fails to respond to a surface roughness variation. We determined the roughness factors of the Pt surfaces by atomic force microscopy (AFM) images, which yielded values between 2.72 and 25.91. Almost the same values were found by using the charge of the hydrogen monolayer desorption obtained from steady-state cyclic voltammetry experiments performed in an acid medium. They were then compared with those provided by peak current in voltammetry or chronoamperometry with Fe(CN)6 3-/Fe(CN)64- which all yielded values nearly to one. Such comparison demonstrates that the electrochemical behavior of the redox probe is an outer sphere reaction with a quite small interaction with the electrode surface, thus not being suitable to be related with active areas.
- 1 January 2021
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
- Vol. 32 (10) , 1912-1917
Estimating the Electrochemically Active Area: Revisiting a Basic Concept in Electrochemistry
The well-known electrochemical probe Fe(CN)63-/Fe(CN)64- is widely used for estimating the electrochemically active area of electrodes modified with carbon nanotubes, conductive polymers, enzymes, etc. In this study, we used the platinum electrode, smooth or platinized with different roughness factors, to demonstrate that such a redox couple fails to respond to a surface roughness variation. We determined the roughness factors of the Pt surfaces by atomic force microscopy (AFM) images, which yielded values between 2.72 and 25.91. Almost the same values were found by using the charge of the hydrogen monolayer desorption obtained from steady-state cyclic voltammetry experiments performed in an acid medium. They were then compared with those provided by peak current in voltammetry or chronoamperometry with Fe(CN)6 3-/Fe(CN)64- which all yielded values nearly to one. Such comparison demonstrates that the electrochemical behavior of the redox probe is an outer sphere reaction with a quite small interaction with the electrode surface, thus not being suitable to be related with active areas.
- 1 July 2018
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 820, 89-96
A photoelectrochemical methodology to obtain nanorods of crystalline hexagonal trigonal selenium
- 1 July 2018
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 820, 89-96
A photoelectrochemical methodology to obtain nanorods of crystalline hexagonal trigonal selenium
- Open Access
Electrochemical Determination of Norepinephrine by Means of Modified Glassy Carbon Electrodes with Carbon Nanotubes and Magnetic Nanoparticles of Cobalt Ferrite
This study describes the electrochemical preparation of the electrocatalytic oxidation/reduction of noradrenaline in modified glassy carbon of cobalt ferrite nanoparticles and carbon nanotubes (GC/MWCNT/FCo98). The cobalt ferrite powder was characterized by X-ray diffraction (XRD) and transmission electron microscopy (TEM). The optimum conditions found in an electrode composition were 4 μL of cobalt ferrite and 10 μL of carbon nanotubes in 0.1 mol L−1 PBS at pH 7.0. The electrode displays electrochemical behavior in a wide potential range (−0.4 to 1.0 V vs. Ag/AgCl), high conductivity, and electrode stability/durability in 0.1 mol L−1 PBS. Catalytic oxidation of noradrenaline was performed at the unmodified GC electrode at +0.60 V vs. Ag/AgCl and current of 0.17 μA and modified GC with cobalt ferrite nanoparticles and carbon nanotubes at +0.54 V vs. Ag/AgCl and current of 0.23 mA. With regard to the anodic peak current (Ipa) versus noradrenaline concentration by means of the amperometric method at the modified electrode, (which is linear in the 0.16 and 1.91 mmol L−1 concentration range), the concentration limit was 0.76 μmol L−1. In this way, the modified electrode GC/MWCNT/FCo98 was found to be a promising application for the determination of this neurotransmitter in the area of neuroscience.
Open AccessElectrochemical Determination of Norepinephrine by Means of Modified Glassy Carbon Electrodes with Carbon Nanotubes and Magnetic Nanoparticles of Cobalt Ferrite
This study describes the electrochemical preparation of the electrocatalytic oxidation/reduction of noradrenaline in modified glassy carbon of cobalt ferrite nanoparticles and carbon nanotubes (GC/MWCNT/FCo98). The cobalt ferrite powder was characterized by X-ray diffraction (XRD) and transmission electron microscopy (TEM). The optimum conditions found in an electrode composition were 4 μL of cobalt ferrite and 10 μL of carbon nanotubes in 0.1 mol L−1 PBS at pH 7.0. The electrode displays electrochemical behavior in a wide potential range (−0.4 to 1.0 V vs. Ag/AgCl), high conductivity, and electrode stability/durability in 0.1 mol L−1 PBS. Catalytic oxidation of noradrenaline was performed at the unmodified GC electrode at +0.60 V vs. Ag/AgCl and current of 0.17 μA and modified GC with cobalt ferrite nanoparticles and carbon nanotubes at +0.54 V vs. Ag/AgCl and current of 0.23 mA. With regard to the anodic peak current (Ipa) versus noradrenaline concentration by means of the amperometric method at the modified electrode, (which is linear in the 0.16 and 1.91 mmol L−1 concentration range), the concentration limit was 0.76 μmol L−1. In this way, the modified electrode GC/MWCNT/FCo98 was found to be a promising application for the determination of this neurotransmitter in the area of neuroscience.