Tomasz Smektała
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tomasz Smektała has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
Katarzyna Sporniak-Tutak
Department of Maxillofacial Surgery,Pomeranian Medical University,Szczecin
7 shared publications- Marcin Słojewski
Department of Urology and Urological Oncology, Pomeranian Medical University, Powstańców Wielkopolskich 72, 70-111 Szczecin, Poland
4 shared publications Marcin Tutak
Private Dental Practice
4 shared publicationsAdam Golab
Department and Clinic of Urology and Urological Oncology, Pomeranian Medical University , Szczecin, Poland
3 shared publications- Kazimierz Ciechanowski
Department of Nephrology, Transplantology and Internal Medicine, Pomeranian Medical University, Szczecin, Poland
3 shared publications Krzysztof Sindrewicz
Department of Maxillofacial Surgery, Pomeranian Medical University, Szczecin, Poland
3 shared publications
Latest Publications
- 23 March 2018
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 30 (4) , 287-298
Effects of different etching modes on the nanoleakage of universal adhesives: A systematic review and meta‐analysis
Purpose: The aim of this systematic review was to evaluate how etching modes affect the nanoleakage of universal adhesive from in vitro studies.Materials and methods: PubMed/MEDLINE, Web of Science, Scopus and Science Direct electronic databases were searched for in vitro studies that evaluated the nanoleakage of universal adhesives. A total of 511 (after duplicate removal) potentially relevant records were identified in the literature search. The titles and abstracts of the retrieved studies were screened by two independent researchers according to the main concept. Subsequently, the full text of potentially relevant studies was screened using the exclusion criteria. Thirteen studies were subjected to qualitative analysis, and 5 of them were selected for a detailed meta‐analysis.Results: Seven universal adhesives were evaluated in this review. The meta‐analysis demonstrated that the etch‐and‐rinse technique significantly reduced the nanoleakage of the Peak Universal and G‐Bond Plus adhesives, whereas the self‐etch mode reduced the nanoleakage of All‐Bond Universal. In comparison, the etching technique did not significantly alter the nanoleakage of either Prime&Bond Elect or Scotchbond Universal which was characterized by the smallest nanoleakage.Conclusions: Etching modes significantly, in various ways, influence the nanoleakage of universal adhesives.Clinical significance: Contrary to the drive to simplify bonding technologies, an appreciation of their adhesive components and how these perform according to bonding technique could yield a knowledge‐based practical approach that ultimately improves the longevity of direct composite restorations.
- 23 March 2018
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 30 (4) , 287-298
Effects of different etching modes on the nanoleakage of universal adhesives: A systematic review and meta‐analysis
Purpose: The aim of this systematic review was to evaluate how etching modes affect the nanoleakage of universal adhesive from in vitro studies.Materials and methods: PubMed/MEDLINE, Web of Science, Scopus and Science Direct electronic databases were searched for in vitro studies that evaluated the nanoleakage of universal adhesives. A total of 511 (after duplicate removal) potentially relevant records were identified in the literature search. The titles and abstracts of the retrieved studies were screened by two independent researchers according to the main concept. Subsequently, the full text of potentially relevant studies was screened using the exclusion criteria. Thirteen studies were subjected to qualitative analysis, and 5 of them were selected for a detailed meta‐analysis.Results: Seven universal adhesives were evaluated in this review. The meta‐analysis demonstrated that the etch‐and‐rinse technique significantly reduced the nanoleakage of the Peak Universal and G‐Bond Plus adhesives, whereas the self‐etch mode reduced the nanoleakage of All‐Bond Universal. In comparison, the etching technique did not significantly alter the nanoleakage of either Prime&Bond Elect or Scotchbond Universal which was characterized by the smallest nanoleakage.Conclusions: Etching modes significantly, in various ways, influence the nanoleakage of universal adhesives.Clinical significance: Contrary to the drive to simplify bonding technologies, an appreciation of their adhesive components and how these perform according to bonding technique could yield a knowledge‐based practical approach that ultimately improves the longevity of direct composite restorations.
- 31 August 2017
- Published by Cambridge University Press (CUP) in International Journal of Technology Assessment in Health Care
- Vol. 33 (4) , 487-493
OPEN-SOURCE SOFTWARE IN DENTISTRY: A SYSTEMATIC REVIEW
Objectives:Technological development and the need for electronic health records management resulted in the need for a computer with dedicated, commercial software in daily dental practice. The alternative for commercial software may be open-source solutions. Therefore, this study reviewed the current literature on the availability and use of open-source software (OSS) in dentistry.Methods:A comprehensive database search was performed on February 1, 2017. Only articles published in peer-reviewed journals with a focus on the use or description of OSS were retrieved. The level of evidence, according to Oxford EBM Centre Levels of Evidence Scale was classified for all studies. Experimental studies underwent additional quality reporting assessment.Results:The screening and evaluation process resulted in twenty-one studies from 1,940 articles found, with 10 of them being experimental studies. None of the articles provided level 1 evidence, and only one study was considered high quality following quality assessment.Twenty-six different OSS programs were described in the included studies of which ten were used for image visualization, five were used for healthcare records management, four were used for educations processes, one was used for remote consultation and simulation, and six were used for general purposes.Conclusions:Our analysis revealed that the dental literature on OSS consists of scarce, incomplete, and methodologically low quality information.
- 31 August 2017
- Published by Cambridge University Press (CUP) in International Journal of Technology Assessment in Health Care
- Vol. 33 (4) , 487-493
OPEN-SOURCE SOFTWARE IN DENTISTRY: A SYSTEMATIC REVIEW
Objectives:Technological development and the need for electronic health records management resulted in the need for a computer with dedicated, commercial software in daily dental practice. The alternative for commercial software may be open-source solutions. Therefore, this study reviewed the current literature on the availability and use of open-source software (OSS) in dentistry.Methods:A comprehensive database search was performed on February 1, 2017. Only articles published in peer-reviewed journals with a focus on the use or description of OSS were retrieved. The level of evidence, according to Oxford EBM Centre Levels of Evidence Scale was classified for all studies. Experimental studies underwent additional quality reporting assessment.Results:The screening and evaluation process resulted in twenty-one studies from 1,940 articles found, with 10 of them being experimental studies. None of the articles provided level 1 evidence, and only one study was considered high quality following quality assessment.Twenty-six different OSS programs were described in the included studies of which ten were used for image visualization, five were used for healthcare records management, four were used for educations processes, one was used for remote consultation and simulation, and six were used for general purposes.Conclusions:Our analysis revealed that the dental literature on OSS consists of scarce, incomplete, and methodologically low quality information.
- 1 April 2017
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 27 (4) , 420-422
Laparoscopic Partial Nephrectomy Supported by Training Involving Personalized Silicone Replica Poured in Three-Dimensional Printed Casting Mold
Most kidney neoplasms are found incidentally and qualify for nephron-sparing surgery. Laparoscopic approach is beneficial to these patients because of its minimally invasive approach. However, these operations are both difficult and require plenty of experience and extended training. Some stages of the operation are limited by permissible time of transient ischemia. We applied three-dimensional (3D) printing technology to create individual silicone models of kidney to be used for training in laparoscopic procedures before the actual surgeries. Three patients who qualified for laparoscopic partial nephrectomy were selected. Digital models of their kidneys with tumors were designed based on computed tomography scans, followed by creation of silicone models. These were cast into the forms printed in 3D. The proper surgery was preceded by an operation carried out in a silicone model of laparoscopic simulator in which the tumor was excised and lodged after tumorectomy was filled. Average time of the live kidney tumor operation was slightly shorter than that of the silicone model (16 versus 17 minutes). Relatively short period of ischemia did not exceed 9 minutes. One patient underwent surgery without closing the vascular pedicle. Experience gained during training with these silicone models improved the actual surgery and can reduce the need for/duration of intraoperative renal ischemia. We believe this training method can be successfully used in other procedures.
- 1 April 2017
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 27 (4) , 420-422
Laparoscopic Partial Nephrectomy Supported by Training Involving Personalized Silicone Replica Poured in Three-Dimensional Printed Casting Mold
Most kidney neoplasms are found incidentally and qualify for nephron-sparing surgery. Laparoscopic approach is beneficial to these patients because of its minimally invasive approach. However, these operations are both difficult and require plenty of experience and extended training. Some stages of the operation are limited by permissible time of transient ischemia. We applied three-dimensional (3D) printing technology to create individual silicone models of kidney to be used for training in laparoscopic procedures before the actual surgeries. Three patients who qualified for laparoscopic partial nephrectomy were selected. Digital models of their kidneys with tumors were designed based on computed tomography scans, followed by creation of silicone models. These were cast into the forms printed in 3D. The proper surgery was preceded by an operation carried out in a silicone model of laparoscopic simulator in which the tumor was excised and lodged after tumorectomy was filled. Average time of the live kidney tumor operation was slightly shorter than that of the silicone model (16 versus 17 minutes). Relatively short period of ischemia did not exceed 9 minutes. One patient underwent surgery without closing the vascular pedicle. Experience gained during training with these silicone models improved the actual surgery and can reduce the need for/duration of intraoperative renal ischemia. We believe this training method can be successfully used in other procedures.
- 1 September 2016
- Vol. 69 (7) , 434-6
Low cost silicone renal replicas for surgical training - technical note.
The aim of this brief report was to present and evaluate workflow of preparation of lowcost individual silicone replicas of kidneys for laparoscopic training and surgical simulation of difficult nephron sparing surgeries. The work flow consists of four steps: 1.Image segmentation; 2.Casting mould designing; 3.Manufacturing of casting mould; 4.Silicone replica casting. To evaluate the cost and time required to execute the presented method, authors prepared 5 silicone models for 5 consecutive patients undergoing laparoscopic kidney tumorectomy due to renal cell cancer. Average times of image segmentation, casting mould design, casting mould printing and pouring of silicon replicas were 94 min, 22 min, 14 h and 30 min, respectively. Average costs of casting mould printing and casting of silicon replica were 14.4$ and 7.4$ respectively. The presented technique is simple to perform and beyond basic 3D printer it does not require any other expensive equipment. The final silicone model reproduces shape and elasticity of the living organ and has similar mechanical strength. These properties of silicone replica in combination with the presented technique can be used to prepare other artificial organs, ready for a simulation of treatment.
- 1 September 2016
- Vol. 69 (7) , 434-6
Low cost silicone renal replicas for surgical training - technical note.
The aim of this brief report was to present and evaluate workflow of preparation of lowcost individual silicone replicas of kidneys for laparoscopic training and surgical simulation of difficult nephron sparing surgeries. The work flow consists of four steps: 1.Image segmentation; 2.Casting mould designing; 3.Manufacturing of casting mould; 4.Silicone replica casting. To evaluate the cost and time required to execute the presented method, authors prepared 5 silicone models for 5 consecutive patients undergoing laparoscopic kidney tumorectomy due to renal cell cancer. Average times of image segmentation, casting mould design, casting mould printing and pouring of silicon replicas were 94 min, 22 min, 14 h and 30 min, respectively. Average costs of casting mould printing and casting of silicon replica were 14.4$ and 7.4$ respectively. The presented technique is simple to perform and beyond basic 3D printer it does not require any other expensive equipment. The final silicone model reproduces shape and elasticity of the living organ and has similar mechanical strength. These properties of silicone replica in combination with the presented technique can be used to prepare other artificial organs, ready for a simulation of treatment.
- 19 August 2016
- Published by IMR Press in The Heart Surgery Forum
- Vol. 19 (4) , 185-186
Three-Dimensional Printing as an Interdisciplinary Communication Tool: Preparing for Removal of a Giant Renal Tumor and Atrium Neoplastic Mass
Three-dimensional (3D) printing involves preparing 3D objects from a digital model. These models can be used to plan and practice surgery. We used 3D printing to plan for a rare complicated surgery involving the removal of a renal tumor and neoplastic mass, which reached the heart atrium. A printed kidney model was an essential element of communication for physicians with different specializations.
- 19 August 2016
- Published by IMR Press in The Heart Surgery Forum
- Vol. 19 (4) , 185-186
Three-Dimensional Printing as an Interdisciplinary Communication Tool: Preparing for Removal of a Giant Renal Tumor and Atrium Neoplastic Mass
Three-dimensional (3D) printing involves preparing 3D objects from a digital model. These models can be used to plan and practice surgery. We used 3D printing to plan for a rare complicated surgery involving the removal of a renal tumor and neoplastic mass, which reached the heart atrium. A printed kidney model was an essential element of communication for physicians with different specializations.
- 13 May 2016
- Published by S. Karger AG in Urologia Internationalis
- Vol. 100 (4) , 485-487
Percutaneous Nephrolithotomy Using an Individual 3-Dimensionally Printed Surgical Guide
Percutaneous nephrolithotomy (PNL) is an endoscopic technique used for treating large stones, multiple stones, and staghorn calculi. Although minimally invasive, complication rate of PNL reaches 25%, and it is partially associated with needle puncture during nephrostomy tract preparation. Continuous improvement of armamentarium and imaging methods and the introduction of three-dimensional (3D) visualizations optimize the procedure; however, the rapid and precise establishment of the nephrostomy tract is still difficult. In the present short communication, we present the PNL procedure assisted by a personalized 3D-printed surgical guide (SG) to ensure fast and precise needle access to the renal collecting system. We also describe the workflow for SG preparation, which consists of CT image acquisition and data segmentation, planning a safe needle insertion path, SG designing, and guide manufacturing. With the growing market of low-cost 3D printers, the presented technique can shorten the PNL procedure time and decrease the complication rate associated with needle puncture in a cost-efficient manner.
- 13 May 2016
- Published by S. Karger AG in Urologia Internationalis
- Vol. 100 (4) , 485-487
Percutaneous Nephrolithotomy Using an Individual 3-Dimensionally Printed Surgical Guide
Percutaneous nephrolithotomy (PNL) is an endoscopic technique used for treating large stones, multiple stones, and staghorn calculi. Although minimally invasive, complication rate of PNL reaches 25%, and it is partially associated with needle puncture during nephrostomy tract preparation. Continuous improvement of armamentarium and imaging methods and the introduction of three-dimensional (3D) visualizations optimize the procedure; however, the rapid and precise establishment of the nephrostomy tract is still difficult. In the present short communication, we present the PNL procedure assisted by a personalized 3D-printed surgical guide (SG) to ensure fast and precise needle access to the renal collecting system. We also describe the workflow for SG preparation, which consists of CT image acquisition and data segmentation, planning a safe needle insertion path, SG designing, and guide manufacturing. With the growing market of low-cost 3D printers, the presented technique can shorten the PNL procedure time and decrease the complication rate associated with needle puncture in a cost-efficient manner.
- Open Access
- 16 March 2016
- Published by Walter de Gruyter GmbH in Postępy Higieny I Medycyny Doświadczalnej
- Vol. 70, 210-218
Wegener’s granulomatosis and pyoderma gangrenosum – rare causes of facial ulcerations
Pyoderma gangrenosum (PG) is caused by immune system dysfunction, and particularly improper functioning of neutrophils. At least half of all PG patients also suffer from autoimmunological diseases, one of which is Wegener granulomatosis (WG). The purpose of this article was to compare cases of patients with WG and PG in terms of their clinical course, histopathology, and applied treatment. In both, histopathological features are not fully distinct. Data from microbiological and immunological evaluation and clinical presentation are required to establish the diagnosis. We also present the case of a patient with WG and deep facial skin lesions not responding to standard treatment. Systematic review of the literature in PubMed using the search terms "Wegener granulomatosis AND Pyoderma gangrenosum" and case report. The finding of 22 reports in the literature (PubMed) suggests that it is a rare phenomenon. This study revealed a similar rate of comorbidity of WG and PG in both genders and an increased incidence of both diseases after the age of 50. Among skin lesions there was a dominance of ulceration, most often deep and painful, covering a large area with the presence of advanced necrosis and destruction of the surrounding tissue. The most common location proved to be the cervical-cephalic area. The most popular treatment included steroids with cyclophosphamide. The rarity of the coexistence of these two diseases results in a lack of effective therapy. In such cases sulfone derivatives are still effective and provide an alternative to standard immunosuppression methods. Hyperbaric therapy and plasmapheresis can also play an important complementary role.
- 16 March 2016
- Published by Walter de Gruyter GmbH in Postępy Higieny I Medycyny Doświadczalnej
- Vol. 70, 210-218
Open AccessWegener’s granulomatosis and pyoderma gangrenosum – rare causes of facial ulcerations
Pyoderma gangrenosum (PG) is caused by immune system dysfunction, and particularly improper functioning of neutrophils. At least half of all PG patients also suffer from autoimmunological diseases, one of which is Wegener granulomatosis (WG). The purpose of this article was to compare cases of patients with WG and PG in terms of their clinical course, histopathology, and applied treatment. In both, histopathological features are not fully distinct. Data from microbiological and immunological evaluation and clinical presentation are required to establish the diagnosis. We also present the case of a patient with WG and deep facial skin lesions not responding to standard treatment. Systematic review of the literature in PubMed using the search terms "Wegener granulomatosis AND Pyoderma gangrenosum" and case report. The finding of 22 reports in the literature (PubMed) suggests that it is a rare phenomenon. This study revealed a similar rate of comorbidity of WG and PG in both genders and an increased incidence of both diseases after the age of 50. Among skin lesions there was a dominance of ulceration, most often deep and painful, covering a large area with the presence of advanced necrosis and destruction of the surrounding tissue. The most common location proved to be the cervical-cephalic area. The most popular treatment included steroids with cyclophosphamide. The rarity of the coexistence of these two diseases results in a lack of effective therapy. In such cases sulfone derivatives are still effective and provide an alternative to standard immunosuppression methods. Hyperbaric therapy and plasmapheresis can also play an important complementary role.
- Open Access
- 11 February 2016
- Published by Walter de Gruyter GmbH in Postępy Higieny I Medycyny Doświadczalnej
- Vol. 70, 74-79
Effect of methylprednisolone, hyaluronic acid and pioglitazone on histological remodeling of temporomandibular joint cartilage in rabbits affected by drug-induced osteoarthritis
The aims of this study were to assess the anti-degenerative effects of pioglitazone and to compare these effects with those of methylprednisolone and hyaluronic acid on drug-induced osteoarthritis in rabbits' temporomandibular joint cartilage. The experiment was conducted on 40 Californian white rabbits. Degenerative changes were induced by intra-articular injections of papain. Subsequently, all of the animals were randomly assigned to one of four groups: 1) a control group that received no medications; 2) a group treated with 4 intra-articular injections of 2 mg (0.2 ml) of hyaluronic acid at weekly intervals; 3) a group treated with 4 intra-articular injections of 2 mg (0.1 ml) of methylprednisolone at weekly intervals; 4) a group administered pioglitazone orally in daily doses of 2 mg/kg of body weight. Four weeks after the beginning of drug administration, the rabbits were sacrificed. Sagittal sections of the intra-articular cartilage (discs) and mandibular condyles were stained with hematoxylin and eosin by the PAS technique and with van Gieson's solution. Histologic examinations, as well as cartilage thickness and number of cell layers measurements, were performed. Histologic assessment in cases of arthritis-associated pathologies revealed that changes occurred most frequently in the control group and least frequently in the pioglitazone group. There were no differences in the histological structures of the intra-articular discs. Cartilage thickness measurements demonstrated the thinnest cartilage in group 2 and the thickest in group 3. Analysis of cell layer numbers showed the most numerous layers in the pioglitazone group and the least in the control group. Pioglitazone and hyaluronic acid showed anti-degenerative properties compared to methylprednisolone in an animal model.
- 11 February 2016
- Published by Walter de Gruyter GmbH in Postępy Higieny I Medycyny Doświadczalnej
- Vol. 70, 74-79
Open AccessEffect of methylprednisolone, hyaluronic acid and pioglitazone on histological remodeling of temporomandibular joint cartilage in rabbits affected by drug-induced osteoarthritis
The aims of this study were to assess the anti-degenerative effects of pioglitazone and to compare these effects with those of methylprednisolone and hyaluronic acid on drug-induced osteoarthritis in rabbits' temporomandibular joint cartilage. The experiment was conducted on 40 Californian white rabbits. Degenerative changes were induced by intra-articular injections of papain. Subsequently, all of the animals were randomly assigned to one of four groups: 1) a control group that received no medications; 2) a group treated with 4 intra-articular injections of 2 mg (0.2 ml) of hyaluronic acid at weekly intervals; 3) a group treated with 4 intra-articular injections of 2 mg (0.1 ml) of methylprednisolone at weekly intervals; 4) a group administered pioglitazone orally in daily doses of 2 mg/kg of body weight. Four weeks after the beginning of drug administration, the rabbits were sacrificed. Sagittal sections of the intra-articular cartilage (discs) and mandibular condyles were stained with hematoxylin and eosin by the PAS technique and with van Gieson's solution. Histologic examinations, as well as cartilage thickness and number of cell layers measurements, were performed. Histologic assessment in cases of arthritis-associated pathologies revealed that changes occurred most frequently in the control group and least frequently in the pioglitazone group. There were no differences in the histological structures of the intra-articular discs. Cartilage thickness measurements demonstrated the thinnest cartilage in group 2 and the thickest in group 3. Analysis of cell layer numbers showed the most numerous layers in the pioglitazone group and the least in the control group. Pioglitazone and hyaluronic acid showed anti-degenerative properties compared to methylprednisolone in an animal model.
- 21 August 2015
- Published by Springer Nature in Journal of Maxillofacial and Oral Surgery
- Vol. 15 (3) , 285-292
Three-Dimensional Cephalometric Analysis of Orbital Morphology Modification for Midface Correction Surgery
The aim of this study was to create an evidence-based three-dimensional cephalometric analysis of orbits in order to perform time-efficient measurements of postoperative orbital morphology changes. The authors used 23 (11 bilateral and 1 unilateral) anatomical landmarks. Based on these, 6 planes, 12 angular and 16 linear measurements were determined. A three dimensional analysis was performed twice by two observers on pre and post-operative computed tomography scans of six patients who had undergone midface advancement. The mean, minimal and maximal difference, as well as standard deviation (SD) and intraclass correlation coefficient (ICC) for the inter- and intra-observer landmark selection reliability were calculated. Additionally, the mean, minimal, maximal difference and standard deviation between pre- and post-operative angular and linear measurements were calculated to examine a connection between the established measurements and any morphological change. The inter and intra-examiner accuracy of all landmarks for three axes was >0.9 ICC. Despite excellent inter and intra-examiner agreement (<2.49 mm ± 2.05 mm SD) for the landmark selection, linear and angular measurements showed a mismatch, the mean SD for angular measurements was found to be 8.2° and the linear 3.04 mm. The possible causes of linear and angular measurement discrepancies are discussed and the future direction for the development of three-dimensional cephalometric analysis of orbits proposed.
- 21 August 2015
- Published by Springer Nature in Journal of Maxillofacial and Oral Surgery
- Vol. 15 (3) , 285-292
Three-Dimensional Cephalometric Analysis of Orbital Morphology Modification for Midface Correction Surgery
The aim of this study was to create an evidence-based three-dimensional cephalometric analysis of orbits in order to perform time-efficient measurements of postoperative orbital morphology changes. The authors used 23 (11 bilateral and 1 unilateral) anatomical landmarks. Based on these, 6 planes, 12 angular and 16 linear measurements were determined. A three dimensional analysis was performed twice by two observers on pre and post-operative computed tomography scans of six patients who had undergone midface advancement. The mean, minimal and maximal difference, as well as standard deviation (SD) and intraclass correlation coefficient (ICC) for the inter- and intra-observer landmark selection reliability were calculated. Additionally, the mean, minimal, maximal difference and standard deviation between pre- and post-operative angular and linear measurements were calculated to examine a connection between the established measurements and any morphological change. The inter and intra-examiner accuracy of all landmarks for three axes was >0.9 ICC. Despite excellent inter and intra-examiner agreement (<2.49 mm ± 2.05 mm SD) for the landmark selection, linear and angular measurements showed a mismatch, the mean SD for angular measurements was found to be 8.2° and the linear 3.04 mm. The possible causes of linear and angular measurement discrepancies are discussed and the future direction for the development of three-dimensional cephalometric analysis of orbits proposed.
- 1 July 2015
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 26 (5) , 1652-1655
Three-Dimensional Eyeball and Orbit Volume Modification After LeFort III Midface Distraction
The aim of our study was to evaluate orbital volume modification with LeFort III midface distraction in patients with craniosynostosis and its influence on eyeball volume and axial diameter modification. Orbital volume was assessed by the semiautomatic segmentation method based on deformable surface models and on 3-dimensional (3D) interaction with haptics. The eyeball volumes and diameters were automatically calculated after manual segmentation of computed tomographic scans with 3D slicer software. The mean, minimal, and maximal differences as well as the standard deviation and intraclass correlation coefficient (ICC) for intraobserver and interobserver measurements reliability were calculated. The Wilcoxon signed rank test was used to compare measured values before and after surgery. P < 0.05 was considered statistically significant. Intraobserver and interobserver ICC for haptic-aided semiautomatic orbital volume measurements were 0.98 and 0.99, respectively. The intraobserver and interobserver ICC values for manual segmentation of the eyeball volume were 0.87 and 0.86, respectively. The orbital volume increased significantly after surgery: 30.32% (mean, 5.96 mL) for the left orbit and 31.04% (mean, 6.31 mL) for the right orbit. The mean increase in eyeball volume was 12.3%. The mean increases in the eyeball axial dimensions were 7.3%, 9.3%, and 4.4% for the X-, Y-, and Z-axes, respectively. The Wilcoxon signed rank test showed that preoperative and postoperative eyeball volumes, as well as the diameters along the X- and Y-axes, were statistically significant. Midface distraction in patients with syndromic craniostenosis results in a significant increase (P < 0.05) in the orbit and eyeball volumes. The 2 methods (haptic-aided semiautomatic segmentation and manual 3D slicer segmentation) are reproducible techniques for orbit and eyeball volume measurements.
- 1 July 2015
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 26 (5) , 1652-1655
Three-Dimensional Eyeball and Orbit Volume Modification After LeFort III Midface Distraction
The aim of our study was to evaluate orbital volume modification with LeFort III midface distraction in patients with craniosynostosis and its influence on eyeball volume and axial diameter modification. Orbital volume was assessed by the semiautomatic segmentation method based on deformable surface models and on 3-dimensional (3D) interaction with haptics. The eyeball volumes and diameters were automatically calculated after manual segmentation of computed tomographic scans with 3D slicer software. The mean, minimal, and maximal differences as well as the standard deviation and intraclass correlation coefficient (ICC) for intraobserver and interobserver measurements reliability were calculated. The Wilcoxon signed rank test was used to compare measured values before and after surgery. P < 0.05 was considered statistically significant. Intraobserver and interobserver ICC for haptic-aided semiautomatic orbital volume measurements were 0.98 and 0.99, respectively. The intraobserver and interobserver ICC values for manual segmentation of the eyeball volume were 0.87 and 0.86, respectively. The orbital volume increased significantly after surgery: 30.32% (mean, 5.96 mL) for the left orbit and 31.04% (mean, 6.31 mL) for the right orbit. The mean increase in eyeball volume was 12.3%. The mean increases in the eyeball axial dimensions were 7.3%, 9.3%, and 4.4% for the X-, Y-, and Z-axes, respectively. The Wilcoxon signed rank test showed that preoperative and postoperative eyeball volumes, as well as the diameters along the X- and Y-axes, were statistically significant. Midface distraction in patients with syndromic craniostenosis results in a significant increase (P < 0.05) in the orbit and eyeball volumes. The 2 methods (haptic-aided semiautomatic segmentation and manual 3D slicer segmentation) are reproducible techniques for orbit and eyeball volume measurements.