BDBruno Degand

Bruno Degand

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bruno Degand has a total of 89 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Impact of obesity on procedural safety and 1-year outcomes after pulsed-field ablation for atrial fibrillation

    by Grégoire Massoullié, Corentin Chaumont, Mikael Laredo, Bruno Pereira, Olivier Thomas, Philippe Maury, Pascal Defaye, Serge Boveda, Eloi Marijon, William Escande, et al.

    Aims: Obesity is associated with atrial fibrillation (AF), atrial remodelling, and cardiometabolic comorbidities. Whether baseline body mass index (BMI) influences procedural safety and effectiveness of pulsed-field ablation (PFA) remains uncertain. We evaluated the association of baseline BMI with procedural characteristics, periprocedural safety, and 1-year arrhythmia recurrence after first-time PFA for AF. Methods and results: FRANCE-PFA is a nationwide registry including consecutive patients undergoing first-time AF ablation with a pentaspline PFA catheter. Patients with available BMI were categorized as <25, 25 to <30, 30 to <35, or ≥35 kg/m2. Periprocedural complications and 1-year atrial arrhythmia recurrence were assessed across BMI categories. Among 5223 patients, BMI was available in 4573 (87.6%). Higher BMI was associated with greater cardiometabolic burden, more persistent AF, larger atria, and more extensive ablation strategies, including fewer pulmonary vein isolation-only procedures and more additional lesion sets (all P < 0.001). Periprocedural complications remained infrequent (1.0%), with no significant difference across BMI categories. At 1 year, recurrence was driven mainly by AF type rather than obesity. Within paroxysmal and non-paroxysmal AF, recurrence rates were comparable between patients with BMI < 35 and ≥35 kg/m2 (13.8% vs. 9.1% and 22.9% vs. 23.3%, respectively; log-rank P = 0.925). Severe obesity was not associated with recurrence after multivariable adjustment (HR, 0.86; 95% CI, 0.65–1.14; P = 0.299), with similar findings when BMI was analysed continuously. Conclusion: In this nationwide PFA cohort, higher BMI identified a more advanced AF phenotype and more extensive ablation strategies but was not independently associated with periprocedural complications or 1-year arrhythmia recurrence.

  • Open Access

    Impact and safety of remote monitoring of heart failure patients managed with the HeartLogic algorithm: the HeartLogic France Cohort Study

    by Rodrigue Garcia, Daniel Gras, Jacques Mansourati, Pascal Defaye, Arnaud Bisson, Serge Boveda, Lisa Durocher, Estelle Gandjbakhch, Matthieu Gras, Jean-Pierre Gueffet, et al.

    Aims: HeartLogic, an algorithm in implanted devices, predicts heart failure (HF) episodes via a remotely monitored index, aiding proactive congestion treatment to prevent acute decompensation. This study assessed the efficacy and safety of pre-emptive HF management using the HeartLogic index. Methods and results: The HeartLogic France Cohort Study is a prospective multicentre investigation involving 310 HF patients with implanted cardioverter defibrillators enrolled from 10 French centres. The HeartLogic™ index was monitored for 12 months, and when the index reached ≥16, patients were contacted to adjust HF treatment. The primary endpoint was unscheduled hospitalization for HF. An independent blinded committee adjudicated the events. A total of 309 patients (65 ± 10 years old; 83.5% male, left ventricular ejection fraction 31 ± 9%) were included in the analysis. Ischemic cardiomyopathy was present in 61.2% (n = 189) of the patients, and 52.8% (n = 163) had a cardiac resynchronization therapy device. During follow-up, 406 alerts occurred in 158 patients (1.33 alerts/patient-year), resulting in treatment modification in 39.6% of alerts. A total of 24 unplanned HF hospitalizations occurred in 19 (6.1%) patients. Sixteen (66.7%) of those hospitalizations were preceded by a HeartLogic alert, of which 14 (87.5%) triggered a drug modification before hospitalization. Eighteen deaths (5.8%) occurred, including 10 due to cardiovascular causes. An increase in creatinine ≥30% and symptomatic hypotension were reported in two patients. Hyperkalemia and hyponatremia were not observed. Conclusion: Pre-emptive HF management guided by the HeartLogic index was associated with low rates of unplanned hospitalizations and adverse events over a 12-month follow-up period. Study registration: ClinicalTrials.gov, ID: NCT04619888.

  • QRS-T angle: is it a specific parameter associated with sudden cardiac death in type 2 diabetes? Results from the SURDIAGENE and the Mini-Finland prospective cohorts

    by Rodrigue Garcia, Linda C. Schröder, Marine Tavernier, Elise Gand, Joe de Keizer, Arttu Holkeri, Antti Eranti, Nicolas Bidegain, Benjamin Alos, Juhani Junttila, et al.

    Aims/hypothesis Type 2 diabetes is associated with a high risk of sudden cardiac death (SCD), but the risk of dying from another cause (non-SCD) is proportionally even higher. The aim of the study was to identify easily available ECG-derived features associated with SCD, while considering the competing risk of dying from non-SCD causes. Methods In the SURDIAGENE (Survie, Diabete de type 2 et Genetique) French prospective cohort of individuals with type 2 diabetes, 15 baseline ECG parameters were interpreted among 1362 participants (mean age 65 years; HbA1c 62±17 mmol/mol [7.8±1.5%]; 58% male). Competing risk models assessed the prognostic value of clinical and ECG parameters for SCD after adjusting for age, sex, history of myocardial infarction, N-terminal pro b-type natriuretic peptide (NT-proBNP), HbA1c and eGFR. The prospective Mini-Finland cohort study was used to externally validate our findings. Results During median follow-up of 7.4 years, 494 deaths occurred including 94 SCDs. After adjustment, frontal QRS-T angle ≥90° (sub-distribution HR [sHR] 1.68 [95% CI 1.04, 2.69], p=0.032) and NT-proBNP level (sHR 1.26 [95% CI 1.06, 1.50] per 1 log, p=0.009) were significantly associated with a higher risk of SCD. Nevertheless, frontal QRS-T angle was the only marker not to be associated with causes of death other than SCD (sHR 1.08 [95% CI 0.84, 1.39], p=0.553 ). These findings were replicated in the Mini-Finland study subset of participants with diabetes (sHR 2.22 [95% CI 1.05, 4.71], p=0.04 for SCD and no association for other causes of death). Conclusions/interpretation QRS-T angle was specifically associated with SCD risk and not with other causes of death, opening an avenue for refining SCD risk stratification in individuals with type 2 diabetes. Graphical Abstract


  • Open Access

    Virtual Reality for Sedation During Atrial Fibrillation Ablation in Clinical Practice: Observational Study

    by Thomas Roxburgh, Anthony Li, Charles Guenancia, Patrice Pernollet, Claire Bouleti, Benjamin Alos, Matthieu Gras, Thomas Kerforne, Denis Frasca, François Le Gal, et al.

    Background: Connected devices are dramatically changing many aspects in health care. One such device, the virtual reality (VR) headset, has recently been shown to improve analgesia in a small sample of patients undergoing transcatheter aortic valve implantation. Objective: We aimed to investigate the feasibility and effectiveness of VR in patients undergoing atrial fibrillation (AF) ablation under conscious sedation. Methods: All patients who underwent an AF ablation with VR from March to May 2020 were included. Patients were compared to a consecutive cohort of patients who underwent AF ablation in the 3 months prior to the study. Primary efficacy was assessed by using a visual analog scale, summarizing the overall pain experienced during the ablation. Results: The AF cryoablation procedure with VR was performed for 48 patients (mean age 63.0, SD 10.9 years; n=16, 33.3% females). No patient refused to use the device, although 14.6% (n=7) terminated the VR session prematurely. Preparation of the VR headset took on average 78 (SD 13) seconds. Compared to the control group, the mean perceived pain, assessed with the visual analog scale, was lower in the VR group (3.5 [SD 1.5] vs 4.3 [SD 1.6]; P=.004), and comfort was higher in the VR group (7.5 [SD 1.6] vs 6.8 [SD 1.7]; P=.03). On the other hand, morphine consumption was not different between the groups. Lastly, complications, as well as procedure and fluoroscopy duration, were not different between the two groups. Conclusions: We found that VR was associated with a reduction in the perception of pain in patients undergoing AF ablation under conscious sedation. Our findings demonstrate that VR can be easily incorporated into the standard ablation workflow.


  • Open Access

    Virtual Reality for Sedation During Atrial Fibrillation Ablation in Clinical Practice: Observational Study (Preprint)

    by Thomas Roxburgh, Anthony Li, Charles Guenancia, Patrice Pernollet, Claire Bouleti, Benjamin Alos, Matthieu Gras, Thomas Kerforne, Denis Frasca, François Le Gal, et al.

    BACKGROUND Connected devices are dramatically changing many aspects in health care. One such device, the virtual reality (VR) headset, has recently been shown to improve analgesia in a small sample of patients undergoing transcatheter aortic valve implantation. OBJECTIVE We aimed to investigate the feasibility and effectiveness of VR in patients undergoing atrial fibrillation (AF) ablation under conscious sedation. METHODS All patients who underwent an AF ablation with VR from March to May 2020 were included. Patients were compared to a consecutive cohort of patients who underwent AF ablation in the 3 months prior to the study. Primary efficacy was assessed by using a visual analog scale, summarizing the overall pain experienced during the ablation. RESULTS The AF cryoablation procedure with VR was performed for 48 patients (mean age 63.0, SD 10.9 years; n=16, 33.3% females). No patient refused to use the device, although 14.6% (n=7) terminated the VR session prematurely. Preparation of the VR headset took on average 78 (SD 13) seconds. Compared to the control group, the mean perceived pain, assessed with the visual analog scale, was lower in the VR group (3.5 [SD 1.5] vs 4.3 [SD 1.6]; P=.004), and comfort was higher in the VR group (7.5 [SD 1.6] vs 6.8 [SD 1.7]; P=.03). On the other hand, morphine consumption was not different between the groups. Lastly, complications, as well as procedure and fluoroscopy duration, were not different between the two groups. CONCLUSIONS We found that VR was associated with a reduction in the perception of pain in patients undergoing AF ablation under conscious sedation. Our findings demonstrate that VR can be easily incorporated into the standard ablation workflow.