Walter Zhongzhong Tang

Walter Zhongzhong Tang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Walter Zhongzhong Tang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:

  • Jinze Li

    Department of Civil and Environmental Engineering, Florida International University, Miami, FL 33174, USA

    5 shared publications
  • Mika Sillanpää

    Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi’an University of Architecture and Technology

    3 shared publications
  • Alam Gustavo Trovó

    Institute of Chemistry, Federal University of Uberlândia, Uberlândia 38400-902, Minas Gerais, Brazil

    2 shared publications
  • Ahmed Dashtey

    Department of Civil and Environmental Engineering Faculty Publications College of Engineering and Computing Department of Civil and Environmental Engineering College of Engineering and Computing Florida International University Florida International University FIU Digital Florida International University Florida International University Florida International University Florida International University Florida International University Florida International University 33199 Miami FL

    1 shared publication
  • Ahmed Khudhair Hassan

    Department of Chemistry, College of Science, Baghdad University, Baghdad, Iraq

    1 shared publication
  • Andrea Troller Pinto

    UFRGS

    1 shared publication

Latest Publications

  • Open Access

    Prediction of PFOA and PFOS Toxicity through Log P and Number of Carbon with CompTox and Machine Learning Tools

    by Ahmed Dashtey, Patrick Mormile, Sandra Pedre, Stephany Valdaliso, Walter Tang

    Perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS) are two major groups of PFAS will be subjected to the Maximal Contamination Concentration (MCL) of 4 ng/l in drinking water to be implemented by the U.S. EPA by 2025. How to accurately predict toxicity of PFAS with varied carbon chain length is important for treatment and sequential removal from drinking water. This study presents Quantitative Structure and Activity Relationship (QSAR) models developed through both linear regression and two order regression. Log P is compiled from reference and carbon content is counted as the molecule represented. Bioconcentration potential is predicted from CompTox.The results suggest that as log P and carbon content increase, the bioconcentration potential of PFCAs also increases. In other words, larger PFCA molecules tend to be easier to bioaccumulate in living organisms. This finding is crucial because bioconcentration refers to the accumulation of substances from water directly into living organisms through the process of passive diffusion across cell membranes. On the other hand, 96-hour fathead minnow LC50 has an inverse relationship, with higher LC50 values associated with lower log P and fewer carbons. The varying R-squared values across methods indicate differing degrees of correlation, underscoring the impact of compound structure on aquatic toxicity. Similarly, for oral rat LD50 and 48-hour D. magna LC50, the R-squared values reflect moderate to strong correlations with log P and the number of carbons. As the log P and carbon content decrease,the toxicity expressed in LC50 or LD50 increases. This relationship underscores the role of chemical properties in influencing the toxicity of PFCAs across different organisms and exposure routes. For instance, the negative correlation between log P and aquatic toxicity (96-hour fathead minnow LC50 and 48-hour D. magna LC50) suggests that compounds with higher hydrophobicity (higher log P) and more carbons may exhibit lower acute toxicity to aquatic organisms.

  • Open Access

    UV Disinfection sensitivity index of spores or protozoa: A model to predict the required fluence of spores or protozoa

    by Zhao Wang, Walter Z. Tang, Mika Sillanpää, Jinze Li

    During UV disinfection, the required UV dose in terms of fluence depends upon the species of bacteria spore and protozoa. To rank their UV disinfection sensitivity, spore sensitivity index (SPSI) and protozoan sensitivity index (PSI) are defined. For spores, shoulder effect exists, therefore, SPSI is defined as the ratio between the ki of any spores for the linear portion of the dose response curve to the kir of Bacillus subtilis as the reference spore. After statistical analysis, the fluence of any spore can be predicted by SPSI through equation, H = (0.8358 ± 0.126)*LogI*SPSI + H0. PSI is defined as the ratio between the inactivation rate constants of a protozoa in reference to that of Cryptosporidium parvum. The equation predicting the fluence of any protozoa in reference to Cryptosporidium parvum is: H = 107.45*(3.86 ± 2.68)*LogI/PSI. Two regression equations suggest that protozoa require significantly higher UV dose than bacteria spores.


  • Improving CH 4 /O 2 energy ratio of meat processing wastewater treatment systems through micro-sieving

    by Jinze Li, Walter Z. Tang

    Micro-sieving is an effective way to prevent organic pollutants enter the main biological process and reduce aeration intensity and sludge production. However, few researchers quantify the effect of the micro-sieving on meat processing wastewater treatment. The current study developed Excel-based models to compare energy consumption and production of historical, conventional, and innovative systems. Historical and conventional systems employ activated sludge (AS), nitrification and denitrification as the biological process. The innovative system was designed by using up-flow anaerobic sludge blanket (UASB) and partial nitrification/Anammox (PN/A). Results shows that the CH4/O2 energy ratios of innovative treatment system are as high as ten times of historical and conventional systems. As a result, innovative system can achieve electrical self-sufficiency. Micro-sieving could save 5% of oxygen demand and increase 1% of CH4/O2 energy ratio in innovative system. Furthermore, the impact of micro-sieving on the innovative treatment train is assessed by cost benefit analysis. System with micro-sieving has the shortest payback time of 2.1 years and reduce cost of the innovative treatment train. The excel-based model quantified the impact of micro-sieving on energy and cost of innovative treatment train, thereby providing a valuable reference for future sustainable wastewater treatment design. GRAPHICAL ABSTRACT

  • Energy efficiency assessment of China wastewater treatment plants by unit energy consumption per kg COD removed

    by Jinze Li, Walter Z. Tang, Li Gu

    Unit energy consumption per kg pollutant removed (kWh/kgCODremoved) is used for the first time in assessing and ranking the sustainability of main treatment technologies of 1215 wastewater treatment plants (WWTPs) in China. The metric better measures the sustainability of main treatment technologies in WWTPs than unit energy consumption per cubic meter treated (kWh/m3). The energy consumption data of these WWTPs were selected from the database of 1399 WWTPs to evaluate the energy efficiency of different treatment technologies. 80.3% of the WWTPs applied anaerobic-oxic plus anaerobic–anoxic–oxic, oxidation ditch, and sequencing batch reactor as main technologies. Statistical analysis shows that the unit energy consumption of WWTPs decreases with increasing design flow rate, operation loading rate, and influent COD concentration. For example, the average unit energy consumption of SBR decreases from 2.76 kWh/kgCODremoved to 0.83 kWh/kgCODremoved when the design flow rate increases from less than 10,000 m3/d to 100,000–200,000 m3/d. The mean unit energy consumption of SBR decreases from 1.71 kWh/kgCODremoved to 1.32 kWh/ kgCODremoved and 2.85 kWh/ kgCODremoved to 0.63 kWh/kgCODremoved as the operation loading rate and COD removal increase from 40% to 100% and from less than 150 mg/L to over 450 mg/L, respectively. SBR has the lowest unit energy consumption among all the technologies. Therefore, SBR might be the most appropriate technology in small and medium-scale WWTPs in China. Regression equations were developed to predict the unit energy consumption for sustainable design treatment trains by input variables such as design flow rate, operation loading rate, and influent COD concentration. GRAPHICAL ABSTRACT


  • Open Access

    Assessment of Energy-Positive Wastewater Treatment System Design of Different Industrial Wastewater Streams

    by Jinze Li, Walter Z. Tang

    Activated sludge (AS) process has been used as the conventional industrial wastewater treatment process in the past decades. However, intensive aeration requirements made it impossible for WWTPs to be energy positive. In addition, there are few cases of research assessing the efficiency and economic feasibility of innovative technologies in treating industrial wastewater to achieve energy positive. This study tries to assess the effect of different kinds of industrial wastewater on treatment efficiency, unit energy, environmental sustainability, and unit cost of treatment systems using innovative technologies such as micro sieving, UASB, and PN/A. Our Excel model showed that micro-sieving could remove 32.50-39.72% of COD from industrial wastewater. UASB reactor could removes 15.8%-53.5%, 14.0%-49.0% and 22.9%-51.0% of COD from three different wastewater streams. Mean unit energy production by the innovative system could reach 1.80, 1.77, and 1.73 kWh/kg BODremoved, respectively. The average unit cost of three kinds of wastewater is 0.54, 0.57, and 1.12 $/kg CODremoved, respectively. Treating meat processing wastewater with innovative technologies is the economical treatment method. However, this method could not be considered as the sustainable design due to the high effluent COD concentration. The economic advantages and limitations of innovative technologies in treating industrial wastewater have been quantified by energy, cost and environmental indicators. These metrics provide valuable references for future sustainable design of industrial wastewater treatment systems.

  • Life cycle cost analysis of dairy production systems in Southern Brazil

    by Clandio Favarini Ruviaro, Cristiane Maria de Leis, Thiago José Florindo, Giovanna Isabelle Bom de Medeiros Florindo, Jaqueline Severino da Costa, Walter Zhongzhong Tang, Andrea Troller Pinto, Sebastião Roberto Soares