Qi Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Qi Wang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Changyuan Yu
The Hong Kong Polytechnic University
3 shared publications - Min Xue
Nanjing University of Aeronautics and Astronautics
3 shared publications - Shilong Pan
Nanjing University of Aeronautics and Astronautics
3 shared publications - Beibei Zhu
Key Laboratory of Radar Imaging and Microwave Photonics, Ministry of Education, Nanjing University of Aeronautics and Astronautics, Nanjing, China
1 shared publication - Chengwu Yang
State Key Laboratory of Integrated Optoelectronics, Institute of semiconductors, Chinese Academy of Sciences, Beijing, China
1 shared publication Jian-Guo Liu
College of Materials Science and Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing 100049
1 shared publication
Latest Publications
- 17 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 40 (8) , 2435-2440
Large Dynamic and Precision Optical Vector Analysis Assisted by SBS Processing
An optical vector analyzer assisted by stimulated Brillouin scattering (SBS) processing is proposed and experimentally demonstrated. Benefitting from the selective amplification and attenuation achieved by the SBS processing, the proposed OVA has enhanced dynamic range and measurement accuracy. An electro-optic modulator produces an intensity-modulated optical double-sideband (ODSB) signal. During the SBS processing, the +1st-order sideband of the ODSB signal is amplified while the -1st-order sideband is attenuated. Thus, an optical single-sideband signal owning a large sideband suppression ratio is achieved, which is then served as the probe signal and passes through an optical device-under-test. Then, by square-law detection, a photocurrent carrying the frequency responses is generated. Receiving and detecting the photocurrent, the multi-dimensional frequency responses, including magnitude, delay, and phase responses, are obtained. In an experiment, 34.05 dB amplification and 22.85 dB attenuation are achieved by the SBS processing. A dynamic range enhancement of 14.01 dB is obtained by measuring an optical bandpass filter, which is well coincident with the theoretical result. The comparative optical transfer delay measurement of a high-precision variable optical delay line indicates accuracy improvement.
- 17 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 40 (8) , 2435-2440
Large Dynamic and Precision Optical Vector Analysis Assisted by SBS Processing
An optical vector analyzer assisted by stimulated Brillouin scattering (SBS) processing is proposed and experimentally demonstrated. Benefitting from the selective amplification and attenuation achieved by the SBS processing, the proposed OVA has enhanced dynamic range and measurement accuracy. An electro-optic modulator produces an intensity-modulated optical double-sideband (ODSB) signal. During the SBS processing, the +1st-order sideband of the ODSB signal is amplified while the -1st-order sideband is attenuated. Thus, an optical single-sideband signal owning a large sideband suppression ratio is achieved, which is then served as the probe signal and passes through an optical device-under-test. Then, by square-law detection, a photocurrent carrying the frequency responses is generated. Receiving and detecting the photocurrent, the multi-dimensional frequency responses, including magnitude, delay, and phase responses, are obtained. In an experiment, 34.05 dB amplification and 22.85 dB attenuation are achieved by the SBS processing. A dynamic range enhancement of 14.01 dB is obtained by measuring an optical bandpass filter, which is well coincident with the theoretical result. The comparative optical transfer delay measurement of a high-precision variable optical delay line indicates accuracy improvement.
- 19 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-5
Broadband Optoelectronic Frequency Response Measurement Utilizing Frequency Conversion
A broadband optoelectronic (O/E) frequency response measurement method utilizing photonics-based frequency conversion is proposed and experimentally demonstrated. It is characterized by a sub-kilohertz frequency resolution and a doubled measurement bandwidth compared with the RF frequency sweeping range and the working bandwidth. A carrier-frequency-shifted optical double-sideband (ODSB) signal is produced by employing a dual-drive Mach-Zehnder modulator (DD-MZM) and stimulated Brillouin scattering (SBS). Then, a photodetector (PD) under test receives and converts the optical signal into a photocurrent. By detecting the frequency up- and down-conversion components generated by the two first-order sidebands and the optical carrier, the O/E frequency responses in the low- and high-frequency regions are achieved. After stitching the two measured responses together, an O/E frequency response with a frequency range that is twice the bandwidth of the input microwave signal is obtained. In an experiment, the O/E frequency response of a commercial high-speed PD is precisely characterized with a frequency resolution up to 5.55 MHz. A frequency bandwidth of 66.8 GHz (0.1–66.9 GHz) is achieved by using a 25-GHz DD-MZM. The measured O/E frequency response is coincident with that measured by a commercial instrument.
- 19 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-5
Broadband Optoelectronic Frequency Response Measurement Utilizing Frequency Conversion
A broadband optoelectronic (O/E) frequency response measurement method utilizing photonics-based frequency conversion is proposed and experimentally demonstrated. It is characterized by a sub-kilohertz frequency resolution and a doubled measurement bandwidth compared with the RF frequency sweeping range and the working bandwidth. A carrier-frequency-shifted optical double-sideband (ODSB) signal is produced by employing a dual-drive Mach-Zehnder modulator (DD-MZM) and stimulated Brillouin scattering (SBS). Then, a photodetector (PD) under test receives and converts the optical signal into a photocurrent. By detecting the frequency up- and down-conversion components generated by the two first-order sidebands and the optical carrier, the O/E frequency responses in the low- and high-frequency regions are achieved. After stitching the two measured responses together, an O/E frequency response with a frequency range that is twice the bandwidth of the input microwave signal is obtained. In an experiment, the O/E frequency response of a commercial high-speed PD is precisely characterized with a frequency resolution up to 5.55 MHz. A frequency bandwidth of 66.8 GHz (0.1–66.9 GHz) is achieved by using a 25-GHz DD-MZM. The measured O/E frequency response is coincident with that measured by a commercial instrument.
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 38 (15) , 3859-3865
Ultrahigh-Resolution Optoelectronic Vector Analysis Utilizing Photonics-Based Frequency Up- and Down-Conversions
An ultrahigh-resolution optoelectronic vector analyzer (OEVA) to characterize optoelectronic (O/E) frequency responses of photodetectors is proposed and experimentally demonstrated, which is characterized by potential sub-Hz frequency resolution, doubled frequency range and large dynamic range. A carrier-suppressed optical double-sideband (ODSB) signal generated by modulating two frequency-swept RF signals with a fixed frequency spacing is used as a probe signal, which is then converted into a photocurrent by the photodetector (PD) under test. Comparing the frequency up- and down-conversion components in the generated photocurrent, the O/E frequency responses can be achieved with no need to know the response of the electro-optic modulator and the modulation indices. As the desired components achieved by frequency up- and down-conversion are frequency distinguished from the two RF signals, the proposed OEVA is immune to electromagnetic interference during on-chip measurement. In the experiment, the O/E frequency responses of two high-speed PDs are characterized from 0.1 to 67 GHz using a 25-GHz Mach-Zehnder modulator (MZM). The frequency resolution is up to 200 kHz. Additionally, the measurement error analysis is analyzed, and the noise performance and the dynamic range are experimentally investigated and discussed.
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 38 (15) , 3859-3865
Ultrahigh-Resolution Optoelectronic Vector Analysis Utilizing Photonics-Based Frequency Up- and Down-Conversions
An ultrahigh-resolution optoelectronic vector analyzer (OEVA) to characterize optoelectronic (O/E) frequency responses of photodetectors is proposed and experimentally demonstrated, which is characterized by potential sub-Hz frequency resolution, doubled frequency range and large dynamic range. A carrier-suppressed optical double-sideband (ODSB) signal generated by modulating two frequency-swept RF signals with a fixed frequency spacing is used as a probe signal, which is then converted into a photocurrent by the photodetector (PD) under test. Comparing the frequency up- and down-conversion components in the generated photocurrent, the O/E frequency responses can be achieved with no need to know the response of the electro-optic modulator and the modulation indices. As the desired components achieved by frequency up- and down-conversion are frequency distinguished from the two RF signals, the proposed OEVA is immune to electromagnetic interference during on-chip measurement. In the experiment, the O/E frequency responses of two high-speed PDs are characterized from 0.1 to 67 GHz using a 25-GHz Mach-Zehnder modulator (MZM). The frequency resolution is up to 200 kHz. Additionally, the measurement error analysis is analyzed, and the noise performance and the dynamic range are experimentally investigated and discussed.
- 1 July 2017
- Published by IOP Publishing in Chinese Physics Letters
- Vol. 34 (8) , 084204
Wideband Tunable Frequency-Doubling Optoelectronic Oscillator Using a Polarization Modulator and an Optical Bandpass Filter
A wideband tunable frequency-doubling optoelectronic oscillator (FD-OEO) is proposed and experimentally demonstrated based on a polarization modulator and an optical bandpass filter (OBPF). The central frequency of the correspondingly fundamental OEO could be adjusted by tuning the bandwidth and central frequency of the OBPF, which could also be regarded as a photonic-assisted tunable microwave filter. The frequency tuning range of the FD-OEO covers from 9.5 to 32.8 GHz, and the single sideband phase noise of the fundamental signal is lower than −100 dBc/Hz at an offset of 10 kHz. Moreover, the frequency stability of the generated signal is investigated by measuring its Allan deviation. The Allan deviation of the generated fundamental signal at 10 GHz is 2.39×10−9.
- 1 July 2017
- Published by IOP Publishing in Chinese Physics Letters
- Vol. 34 (8) , 084204
Wideband Tunable Frequency-Doubling Optoelectronic Oscillator Using a Polarization Modulator and an Optical Bandpass Filter
A wideband tunable frequency-doubling optoelectronic oscillator (FD-OEO) is proposed and experimentally demonstrated based on a polarization modulator and an optical bandpass filter (OBPF). The central frequency of the correspondingly fundamental OEO could be adjusted by tuning the bandwidth and central frequency of the OBPF, which could also be regarded as a photonic-assisted tunable microwave filter. The frequency tuning range of the FD-OEO covers from 9.5 to 32.8 GHz, and the single sideband phase noise of the fundamental signal is lower than −100 dBc/Hz at an offset of 10 kHz. Moreover, the frequency stability of the generated signal is investigated by measuring its Allan deviation. The Allan deviation of the generated fundamental signal at 10 GHz is 2.39×10−9.