Shiyue Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shiyue Chen has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Jun Yao
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
6 shared publications - Jinxin Pei
State Key Laboratory of Power Transmission Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
5 shared publications Sen Huang
State Key Laboratory of Power Transmission Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
4 shared publications- Yuan Liu
State Key Laboratory of Power Transmission Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
4 shared publications Zhaoyang Chen
State Key Laboratory of Power Transmission Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
3 shared publications- Deiyin Zeng
State Key Laboratory of Power Transmission Equipment & System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, China
1 shared publication
Latest Publications
- 23 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 15 (1) , 381-397
Dual-Sequence Synchronization Stability Analysis and Control of Multi-Paralleled Wind Farms During Asymmetrical Grid Faults
The synchronization stability and instability risk assessment of multi-paralleled wind farms during asymmetrical grid faults have received little attention to date. In this article, a simplified equivalent model of multi-paralleled wind farms is established based on the symmetrical components method to deal with the problem of dual-sequence synchronization stability during asymmetrical grid faults. Based on the model, the effects of multiple coupling characteristics such as sequence coupling and mutual coupling of wind farms on the stability of dual-sequence synchronization are studied in detail. Then, an assessment method is proposed to evaluate the dual-sequence synchronization stability of multi-paralleled wind farms under various asymmetrical grid faults. This assessment method can judge whether there are positive-sequence (PS) and negative-sequence (NS) steady-state equilibrium points for each wind farm in the system, and identify the wind farms that are instability due to the lack of a PS/NS equilibrium point. In addition, a current control strategy is derived to maximize the stability margin of dual-sequence synchronization. This strategy can ensure that each wind farm in the system has equilibrium point. Finally, the correctness of the theoretical analysis and the effectiveness of the proposed method are verified by simulation.
- 23 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 15 (1) , 381-397
Dual-Sequence Synchronization Stability Analysis and Control of Multi-Paralleled Wind Farms During Asymmetrical Grid Faults
The synchronization stability and instability risk assessment of multi-paralleled wind farms during asymmetrical grid faults have received little attention to date. In this article, a simplified equivalent model of multi-paralleled wind farms is established based on the symmetrical components method to deal with the problem of dual-sequence synchronization stability during asymmetrical grid faults. Based on the model, the effects of multiple coupling characteristics such as sequence coupling and mutual coupling of wind farms on the stability of dual-sequence synchronization are studied in detail. Then, an assessment method is proposed to evaluate the dual-sequence synchronization stability of multi-paralleled wind farms under various asymmetrical grid faults. This assessment method can judge whether there are positive-sequence (PS) and negative-sequence (NS) steady-state equilibrium points for each wind farm in the system, and identify the wind farms that are instability due to the lack of a PS/NS equilibrium point. In addition, a current control strategy is derived to maximize the stability margin of dual-sequence synchronization. This strategy can ensure that each wind farm in the system has equilibrium point. Finally, the correctness of the theoretical analysis and the effectiveness of the proposed method are verified by simulation.
- 30 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (5) , 4957-4961
Transient Synchronization Stability Improvement Control Strategy for Grid-Connected VSC Under Symmetrical Grid Fault
Under grid fault, the grid-connected voltage source converters (VSCs) have the risk of transient synchronization instability during low voltage ride through. Based on the equivalent rotor swing equation of VSC, this letter proposes an improved transient synchronization stability control strategy, which improves the existence of equilibrium points and transient synchronization behaviors of the VSC system. Thus, the transient synchronization stability of grid-connected VSC can be significantly enhanced. The simulation and experimental results demonstrate the validity of the proposed strategy.
- 30 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (5) , 4957-4961
Transient Synchronization Stability Improvement Control Strategy for Grid-Connected VSC Under Symmetrical Grid Fault
Under grid fault, the grid-connected voltage source converters (VSCs) have the risk of transient synchronization instability during low voltage ride through. Based on the equivalent rotor swing equation of VSC, this letter proposes an improved transient synchronization stability control strategy, which improves the existence of equilibrium points and transient synchronization behaviors of the VSC system. Thus, the transient synchronization stability of grid-connected VSC can be significantly enhanced. The simulation and experimental results demonstrate the validity of the proposed strategy.
- 10 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 37 (2) , 880-891
Transient Stability Analysis and Improved Control Strategy for DC-Link Voltage of DFIG-Based WT During LVRT
In this paper, the transient stability for dc-link voltage of doubly-fed induction generator (DFIG)-based wind turbine (WT) is studied in detail during low voltage ride-through (LVRT). Firstly, referring to the rotor swing equation of synchronous generator (SG), the nonlinear large-signal model of dc-link voltage is established. In addition, the damping power, static slip power, and dynamic slip power are derived. Consequently, the transient performance of dc-link voltage under the different operation conditions of DFIG is revealed during LVRT. Furthermore, the instability form of dc-link voltage with the moving process of equivalent power angle is analyzed by the energy function of dc-link voltage. In addition, the impacts of dc voltage control loop's parameter, the active current of the stator, and the slip on the stabilization process of dc-link voltage are studied. Analysis result indicates that the insufficient damping and large unbalanced power would deteriorate the transient behavior and steady-state level of dc-link voltage. Therefore, an additional damping and slip power feedforward control strategy is proposed, which can make the transition process of dc-link voltage smoother and significantly improve the voltage steady-state level. Finally, simulation and experimental results validate the effectiveness of theoretical analysis.
- 10 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 37 (2) , 880-891
Transient Stability Analysis and Improved Control Strategy for DC-Link Voltage of DFIG-Based WT During LVRT
In this paper, the transient stability for dc-link voltage of doubly-fed induction generator (DFIG)-based wind turbine (WT) is studied in detail during low voltage ride-through (LVRT). Firstly, referring to the rotor swing equation of synchronous generator (SG), the nonlinear large-signal model of dc-link voltage is established. In addition, the damping power, static slip power, and dynamic slip power are derived. Consequently, the transient performance of dc-link voltage under the different operation conditions of DFIG is revealed during LVRT. Furthermore, the instability form of dc-link voltage with the moving process of equivalent power angle is analyzed by the energy function of dc-link voltage. In addition, the impacts of dc voltage control loop's parameter, the active current of the stator, and the slip on the stabilization process of dc-link voltage are studied. Analysis result indicates that the insufficient damping and large unbalanced power would deteriorate the transient behavior and steady-state level of dc-link voltage. Therefore, an additional damping and slip power feedforward control strategy is proposed, which can make the transition process of dc-link voltage smoother and significantly improve the voltage steady-state level. Finally, simulation and experimental results validate the effectiveness of theoretical analysis.
- 10 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (08858993) , 1
Modelling and Transient Synchronization Stability Analysis for PLL-Based Renewable Energy Generator Considering Sequential Switching Schemes
The synchronization characteristics of phase-locked loop (PLL) based renewable energy generators (REG) are considerably sensitive to the grid condition and the inner sequential switching actions of their control system, especially suffered from grid faults. In this article, the general output characteristics of REG systems are investigated considering the nonlinear behaviour of PLL. In addition, general sequential switching control schemes for the entire grid fault process are introduced. Then, to physically determine and theoretically analyze the transient synchronization stability of REG systems, the synchronization model of a REG system for different fault stages is built and presented in the form of rotor swing equations, which are similar to those of a synchronous generator (SG). The proposed model was able to deduce the characteristics of virtual torque, virtual inertia, and virtual damping coefficient of the REG system, and identify the coupling relationship between the angular frequency/magnitude states of the terminal voltage of the REG system during the synchronization process. Thus, the synchronization stability criteria were proposed based on those of the SG, in which the transient instability phenomenon and mechanism for different fault stages is physically explained by the deduced equal area criteria. Finally, the analysis was verified by simulations and experiments.
- 10 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (08858993) , 1
Modelling and Transient Synchronization Stability Analysis for PLL-Based Renewable Energy Generator Considering Sequential Switching Schemes
The synchronization characteristics of phase-locked loop (PLL) based renewable energy generators (REG) are considerably sensitive to the grid condition and the inner sequential switching actions of their control system, especially suffered from grid faults. In this article, the general output characteristics of REG systems are investigated considering the nonlinear behaviour of PLL. In addition, general sequential switching control schemes for the entire grid fault process are introduced. Then, to physically determine and theoretically analyze the transient synchronization stability of REG systems, the synchronization model of a REG system for different fault stages is built and presented in the form of rotor swing equations, which are similar to those of a synchronous generator (SG). The proposed model was able to deduce the characteristics of virtual torque, virtual inertia, and virtual damping coefficient of the REG system, and identify the coupling relationship between the angular frequency/magnitude states of the terminal voltage of the REG system during the synchronization process. Thus, the synchronization stability criteria were proposed based on those of the SG, in which the transient instability phenomenon and mechanism for different fault stages is physically explained by the deduced equal area criteria. Finally, the analysis was verified by simulations and experiments.
- 26 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 12 (4) , 2132-2145
Coupling Mechanism Analysis and Transient Stability Assessment for Multiparalleled Wind Farms During LVRT
In this paper, the coupling mechanism of phase-locked loop (PLL)-synchronized multiparalleled wind farms under grid faults is analyzed in detail. First, the coupling effects of the currents and the equivalent power angles (EPAs) among wind farms are identified by analyzing the voltage characteristics during low voltage ride-through (LVRT). Subsequently, a transient stability assessment method is proposed for multiparalleled wind farms to evaluate the effect of output currents of multiple wind farms on the EPA distribution characteristics. This method can be applied to evaluate whether each wind farm in the system has equilibrium points as well as evaluate the transient instability risk of the system during LVRT. In addition, the dominant wind farms for the system transient instability can be identified. Due to the coupling effects, any inappropriate current in the wind farm may deteriorate the EPA distribution characteristics and even cause loss of synchronism. Consequently, the current distribution method to minimize transient instability risk can ensure that each wind farm in the system has equilibrium points and effectively improve the multiparalleled wind farms stability during LVRT. Finally, the simulations results validate the effectiveness of the theoretical analysis and proposed method.
- 26 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 12 (4) , 2132-2145
Coupling Mechanism Analysis and Transient Stability Assessment for Multiparalleled Wind Farms During LVRT
In this paper, the coupling mechanism of phase-locked loop (PLL)-synchronized multiparalleled wind farms under grid faults is analyzed in detail. First, the coupling effects of the currents and the equivalent power angles (EPAs) among wind farms are identified by analyzing the voltage characteristics during low voltage ride-through (LVRT). Subsequently, a transient stability assessment method is proposed for multiparalleled wind farms to evaluate the effect of output currents of multiple wind farms on the EPA distribution characteristics. This method can be applied to evaluate whether each wind farm in the system has equilibrium points as well as evaluate the transient instability risk of the system during LVRT. In addition, the dominant wind farms for the system transient instability can be identified. Due to the coupling effects, any inappropriate current in the wind farm may deteriorate the EPA distribution characteristics and even cause loss of synchronism. Consequently, the current distribution method to minimize transient instability risk can ensure that each wind farm in the system has equilibrium points and effectively improve the multiparalleled wind farms stability during LVRT. Finally, the simulations results validate the effectiveness of the theoretical analysis and proposed method.
- 22 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (1) , 218-229
Transient Stability Enhancement Control Strategy Based on Improved PLL for Grid Connected VSC during Severe Grid Fault
In this paper, the transient synchronization process of the grid-connected voltage source converters (VSC) is studied detailly. Firstly, the phase-locked loop (PLL)-synchronized VSC is modeled according to the rotor motion equation of synchronous generator (SG). Furthermore, the VSC's damping ratio is derived, and the effects of the VSC's control parameters and the operation status on the equivalent power angle (EPA) is investigated. Moreover, the influence of the PLL's parameters and the voltage dips degree on the VSC's transient frequency behavior are analyzed. Analysis result reveals that the VSC's damping ratio decreases once the grid voltage drops, so that the EPA and frequency of the VSC may appear large overshoot and oscillation, which may trigger the frequency protection and deteriorate the VSC's transient stability. In order to ensure that the VSC can smoothly operate to new equilibrium points, an improved PLL is proposed, which can adaptively adjust the VSC's damping ratio for different voltage sags. The proposed method can not only reduce the overshoot of the EPA but also restrain the VSC's frequency dips degree. Finally, the simulations and experimental tests validate the effectiveness of the theoretical analysis.
- 22 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (1) , 218-229
Transient Stability Enhancement Control Strategy Based on Improved PLL for Grid Connected VSC during Severe Grid Fault
In this paper, the transient synchronization process of the grid-connected voltage source converters (VSC) is studied detailly. Firstly, the phase-locked loop (PLL)-synchronized VSC is modeled according to the rotor motion equation of synchronous generator (SG). Furthermore, the VSC's damping ratio is derived, and the effects of the VSC's control parameters and the operation status on the equivalent power angle (EPA) is investigated. Moreover, the influence of the PLL's parameters and the voltage dips degree on the VSC's transient frequency behavior are analyzed. Analysis result reveals that the VSC's damping ratio decreases once the grid voltage drops, so that the EPA and frequency of the VSC may appear large overshoot and oscillation, which may trigger the frequency protection and deteriorate the VSC's transient stability. In order to ensure that the VSC can smoothly operate to new equilibrium points, an improved PLL is proposed, which can adaptively adjust the VSC's damping ratio for different voltage sags. The proposed method can not only reduce the overshoot of the EPA but also restrain the VSC's frequency dips degree. Finally, the simulations and experimental tests validate the effectiveness of the theoretical analysis.