Taegyu Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Taegyu Kim has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Raymond M. Hozalski
Department of Civil, Environmental, and Geo-Engineering, University of Minnesota, 500 Pillsbury Dr. SE, Minneapolis, Minnesota 55455, United States
6 shared publications - Timothy M. LaPara
University of Minnesota 122, 500 Pillsbury Dr SE
6 shared publications - Charuka Saamantha Meegoda
Department of Building and Environmental Technology, Norwegian University of Life Sciences (NMBU), Drøbakveien 31, 1433 Ås, Norway
3 shared publications - Cynthia Hallé
Department of Civil and Environmental Engineering
3 shared publications - Michael B. Waak
Department of Civil and Environmental Engineering
3 shared publications Sebastian Behrens
Associate Professor, Dept. of Civil, Environmental, and Geo- Engineering & the Biotechnology Institute, Univ. of Minnesota Twin Cities, 500 Pillsbury Dr. S.E., Minneapolis, MN 55455
2 shared publications
Latest Publications
- Open Access
- 28 January 2026
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 60 (5) , 3935-3946
Flushing as a Control Measure for Legionella spp.: Impacts of Water Age, Chloramine Disinfection, and Elevated Temperature
Pilot-scale experiments were used to examine how hot-water temperature, chloramine disinfection, and pipe material (copper or PE-Xa) influence the effectiveness of two flow-based interventions─high-flow flushing vs showering─in controlling total bacteria, Legionella spp., and Vermamoeba vermiformis in premise plumbing. Flushing (ca. 16 L/min for 5 min) and showering (ca. 7 L/min for 8 min) both temporarily reduced bacterial concentrations by removing accumulated planktonic biomass. However, total bacteria rebounded within 1-4 days after a flush or shower, regardless of the presence of chloramines (1 mg/L Cl2). In the absence of chloramines, Legionella spp. ssrA gene concentrations increased over 3-10 days following flushing or showering, whereas chloramines suppressed Legionella spp. for >10 days despite completely decaying within hours of water use. Without chloramines, hot-water flushing at 49 or 60 °C provided little additional control of Legionella spp. as compared to cold-water flushing. V. vermiformis concentrations decreased temporarily following water use, independent of disinfectant or temperature. Flushing was more effective than showering at removing Legionella spp. from biofilms, while pipe material had limited influence in this pilot-scale system. Overall, the results demonstrate organism-specific recovery dynamics and highlight the role of chloramines in prolonging the suppression of Legionella in premise plumbing.
- 28 January 2026
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 60 (5) , 3935-3946
Open AccessFlushing as a Control Measure for Legionella spp.: Impacts of Water Age, Chloramine Disinfection, and Elevated Temperature
Pilot-scale experiments were used to examine how hot-water temperature, chloramine disinfection, and pipe material (copper or PE-Xa) influence the effectiveness of two flow-based interventions─high-flow flushing vs showering─in controlling total bacteria, Legionella spp., and Vermamoeba vermiformis in premise plumbing. Flushing (ca. 16 L/min for 5 min) and showering (ca. 7 L/min for 8 min) both temporarily reduced bacterial concentrations by removing accumulated planktonic biomass. However, total bacteria rebounded within 1-4 days after a flush or shower, regardless of the presence of chloramines (1 mg/L Cl2). In the absence of chloramines, Legionella spp. ssrA gene concentrations increased over 3-10 days following flushing or showering, whereas chloramines suppressed Legionella spp. for >10 days despite completely decaying within hours of water use. Without chloramines, hot-water flushing at 49 or 60 °C provided little additional control of Legionella spp. as compared to cold-water flushing. V. vermiformis concentrations decreased temporarily following water use, independent of disinfectant or temperature. Flushing was more effective than showering at removing Legionella spp. from biofilms, while pipe material had limited influence in this pilot-scale system. Overall, the results demonstrate organism-specific recovery dynamics and highlight the role of chloramines in prolonging the suppression of Legionella in premise plumbing.
- Open Access
- 1 November 2025
- Published by Taylor & Francis in Journal of Inflammation Research
- Vol. ume 18, 16009-16022
Association Between Maternal IBD-Related Antibodies and Early Life Gut Inflammatory Status and Microbiota Composition: Insights from Cord Blood
Purpose: Antibodies in peripheral blood are used to aid in the diagnosis of inflammatory bowel disease (IBD), but their presence in neonatal cord blood and potential effects on early life development remain unknown. Methods: We measured anti-CBir1, ANCA, anti-OmpC, ASCA IgA, and ASCA IgG levels in the cord blood of babies born to 78 mothers with or without IBD. Their association with fecal calprotectin (FC), and microbiota composition, characterized by 16S rRNA sequencing, was assessed throughout pregnancy and during the first three and five years of life, respectively, using linear mixed-effects models. Results: Antibodies were detected in cord blood, with significantly higher levels of anti-CBir1 and ASCA IgG in babies born to mothers with Crohn’s disease (p = 0.002) and higher abundance of ANCA and anti-OmpC in babies of mothers with ulcerative colitis (p = 0.002), compared to controls. ASCA IgG levels positively correlated with babies’ FC (p = 0.006). Both ANCA and anti-OmpC were positively correlated with the abundance of Romboutsia spp. Clostridia, and Pseudomonas spp. while Blautia spp. Citrobacter spp. Clostridiaceae, and Varibaculum spp. were positively correlated with either ANCA or anti-OmpC levels. Higher abundance of Lactobacillus spp. was associated with higher ASCA IgG and anti-CBir1 levels (all multiple testing-adjusted q< 0.1). Conclusion: Our findings suggest that maternal IBD-associated antibodies cross the placenta barrier and may be associated with intestinal inflammation and imbalanced microbiota colonization. Whether these serological profiles negatively influence the priming of the baby’s immune system or IBD risk later in life remains to be determined.
- 1 November 2025
- Published by Taylor & Francis in Journal of Inflammation Research
- Vol. ume 18, 16009-16022
Open AccessAssociation Between Maternal IBD-Related Antibodies and Early Life Gut Inflammatory Status and Microbiota Composition: Insights from Cord Blood
Purpose: Antibodies in peripheral blood are used to aid in the diagnosis of inflammatory bowel disease (IBD), but their presence in neonatal cord blood and potential effects on early life development remain unknown. Methods: We measured anti-CBir1, ANCA, anti-OmpC, ASCA IgA, and ASCA IgG levels in the cord blood of babies born to 78 mothers with or without IBD. Their association with fecal calprotectin (FC), and microbiota composition, characterized by 16S rRNA sequencing, was assessed throughout pregnancy and during the first three and five years of life, respectively, using linear mixed-effects models. Results: Antibodies were detected in cord blood, with significantly higher levels of anti-CBir1 and ASCA IgG in babies born to mothers with Crohn’s disease (p = 0.002) and higher abundance of ANCA and anti-OmpC in babies of mothers with ulcerative colitis (p = 0.002), compared to controls. ASCA IgG levels positively correlated with babies’ FC (p = 0.006). Both ANCA and anti-OmpC were positively correlated with the abundance of Romboutsia spp. Clostridia, and Pseudomonas spp. while Blautia spp. Citrobacter spp. Clostridiaceae, and Varibaculum spp. were positively correlated with either ANCA or anti-OmpC levels. Higher abundance of Lactobacillus spp. was associated with higher ASCA IgG and anti-CBir1 levels (all multiple testing-adjusted q< 0.1). Conclusion: Our findings suggest that maternal IBD-associated antibodies cross the placenta barrier and may be associated with intestinal inflammation and imbalanced microbiota colonization. Whether these serological profiles negatively influence the priming of the baby’s immune system or IBD risk later in life remains to be determined.
- 21 February 2024
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 90 (2) , e0165823
On-site filtration of large sample volumes improves the detection of opportunistic pathogens in drinking water distribution systems
In this study, we compared conventional vacuum filtration of small volumes through disc membranes (effective sample volumes for potable water: 0.3–1.0 L) with filtration of high volumes using ultrafiltration (UF) modules (effective sample volumes for potable water: 10.6–84.5 L) for collecting bacterial biomass from raw, finished, and tap water at seven drinking water systems. Total bacteria, Legionella spp., Legionella pneumophila , Mycobacterium spp., and Mycobacterium avium complex in these samples were enumerated using both conventional quantitative PCR (qPCR) and viability qPCR (using propidium monoazide). In addition, PCR-amplified gene fragments were sequenced for microbial community analysis. The frequency of detection (FOD) of Legionella spp. in finished and tap water samples was much greater using UF modules (83% and 77%, respectively) than disc filters (24% and 33%, respectively). The FODs for Mycobacterium spp. in raw, finished, and tap water samples were also consistently greater using UF modules than disc filters. Furthermore, the number of observed operational taxonomic units and diversity index values for finished and tap water samples were often substantially greater when using UF modules as compared to disc filters. Conventional and viability qPCR yielded similar results, suggesting that membrane-compromised cells represented a minor fraction of total bacterial biomass. In conclusion, our research demonstrates that large-volume filtration using UF modules improved the detection of opportunistic pathogens at the low concentrations typically found in public drinking water systems and that the majority of bacteria in these systems appear to be viable in spite of disinfection with free chlorine and/or chloramine. IMPORTANCE: Opportunistic pathogens, such as Legionella pneumophila , are a growing public health concern. In this study, we compared sample collection and enumeration methods on raw, finished, and tap water at seven water systems throughout the State of Minnesota, USA. The results showed that on-site filtration of large water volumes (i.e., 500–1,000 L) using ultrafiltration membrane modules improved the frequency of detection of relatively rare organisms, including opportunistic pathogens, compared to the common approach of filtering about 1 L using disc membranes. Furthermore, results from viability quantitative PCR (qPCR) with propidium monoazide were similar to conventional qPCR, suggesting that membrane-compromised cells represent an insignificant fraction of microorganisms. Results from these ultrafiltration membrane modules should lead to a better understanding of the microbial ecology of drinking water distribution systems and their potential to inoculate premise plumbing systems with opportunistic pathogens where conditions are more favorable for their growth.
- 21 February 2024
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 90 (2) , e0165823
On-site filtration of large sample volumes improves the detection of opportunistic pathogens in drinking water distribution systems
In this study, we compared conventional vacuum filtration of small volumes through disc membranes (effective sample volumes for potable water: 0.3–1.0 L) with filtration of high volumes using ultrafiltration (UF) modules (effective sample volumes for potable water: 10.6–84.5 L) for collecting bacterial biomass from raw, finished, and tap water at seven drinking water systems. Total bacteria, Legionella spp., Legionella pneumophila , Mycobacterium spp., and Mycobacterium avium complex in these samples were enumerated using both conventional quantitative PCR (qPCR) and viability qPCR (using propidium monoazide). In addition, PCR-amplified gene fragments were sequenced for microbial community analysis. The frequency of detection (FOD) of Legionella spp. in finished and tap water samples was much greater using UF modules (83% and 77%, respectively) than disc filters (24% and 33%, respectively). The FODs for Mycobacterium spp. in raw, finished, and tap water samples were also consistently greater using UF modules than disc filters. Furthermore, the number of observed operational taxonomic units and diversity index values for finished and tap water samples were often substantially greater when using UF modules as compared to disc filters. Conventional and viability qPCR yielded similar results, suggesting that membrane-compromised cells represented a minor fraction of total bacterial biomass. In conclusion, our research demonstrates that large-volume filtration using UF modules improved the detection of opportunistic pathogens at the low concentrations typically found in public drinking water systems and that the majority of bacteria in these systems appear to be viable in spite of disinfection with free chlorine and/or chloramine. IMPORTANCE: Opportunistic pathogens, such as Legionella pneumophila , are a growing public health concern. In this study, we compared sample collection and enumeration methods on raw, finished, and tap water at seven water systems throughout the State of Minnesota, USA. The results showed that on-site filtration of large water volumes (i.e., 500–1,000 L) using ultrafiltration membrane modules improved the frequency of detection of relatively rare organisms, including opportunistic pathogens, compared to the common approach of filtering about 1 L using disc membranes. Furthermore, results from viability quantitative PCR (qPCR) with propidium monoazide were similar to conventional qPCR, suggesting that membrane-compromised cells represent an insignificant fraction of microorganisms. Results from these ultrafiltration membrane modules should lead to a better understanding of the microbial ecology of drinking water distribution systems and their potential to inoculate premise plumbing systems with opportunistic pathogens where conditions are more favorable for their growth.
- 23 March 2023
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 57 (13) , 5453-5463
Flushing Temporarily Improves Microbiological Water Quality for Buildings Supplied with Chloraminated Surface Water but Has Little Effect for Groundwater Supplies
Microbial communities in premise plumbing systems were investigated after more than 2 months of long-term stagnation, during a subsequent flushing event, and during post-flush stagnation. Water samples were collected from showers in buildings supplied with chlorinated groundwater, untreated groundwater, and chloraminated surface water. The building supplied with chlorinated groundwater generally had the lowest bacterial concentrations across all sites (ranging from below quantification limit to 5.2 log copies/L). For buildings supplied with untreated groundwater, bacterial concentrations (5.0 to 7.6 log copies/L) and microbial community diversity index (ACE) values were consistent throughout sampling. Nontuberculous mycobacteria (NTM) and Legionella pneumophila were not detected in any groundwater-supplied buildings. Total bacteria, Legionella spp., and NTM were abundant in the surface water-supplied buildings following long-term stagnation (up to 7.6, 6.2, and 7.6 log copies/L, respectively). Flushing decreased these concentrations by ∼1 to >4 log units and reduced microbial community diversity, but the communities largely recovered within a week of post-flush stagnation. The results suggest that buildings supplied with disinfected surface water are more likely than buildings supplied with treated or untreated groundwater to experience deleterious changes in microbiological water quality during stagnation and that the water quality improvements from flushing with chloraminated water, while substantial, are short-lived.
- 23 March 2023
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 57 (13) , 5453-5463
Flushing Temporarily Improves Microbiological Water Quality for Buildings Supplied with Chloraminated Surface Water but Has Little Effect for Groundwater Supplies
Microbial communities in premise plumbing systems were investigated after more than 2 months of long-term stagnation, during a subsequent flushing event, and during post-flush stagnation. Water samples were collected from showers in buildings supplied with chlorinated groundwater, untreated groundwater, and chloraminated surface water. The building supplied with chlorinated groundwater generally had the lowest bacterial concentrations across all sites (ranging from below quantification limit to 5.2 log copies/L). For buildings supplied with untreated groundwater, bacterial concentrations (5.0 to 7.6 log copies/L) and microbial community diversity index (ACE) values were consistent throughout sampling. Nontuberculous mycobacteria (NTM) and Legionella pneumophila were not detected in any groundwater-supplied buildings. Total bacteria, Legionella spp., and NTM were abundant in the surface water-supplied buildings following long-term stagnation (up to 7.6, 6.2, and 7.6 log copies/L, respectively). Flushing decreased these concentrations by ∼1 to >4 log units and reduced microbial community diversity, but the communities largely recovered within a week of post-flush stagnation. The results suggest that buildings supplied with disinfected surface water are more likely than buildings supplied with treated or untreated groundwater to experience deleterious changes in microbiological water quality during stagnation and that the water quality improvements from flushing with chloraminated water, while substantial, are short-lived.
- Open Access
- 21 March 2023
- Published by Frontiers Media SA in Frontiers in Water
- Vol. 5
The benefits of flushing for mitigating Legionella spp. in non-chlorinated building plumbing systems
Flushing is a common corrective action recommended by Legionella management guidelines to remove stagnant water and replenish disinfectant. Due to water age and different local regulations, buildings may receive water with low or no residual disinfectant. In such situations, the evidence for flushing efficacy is often anecdotal, and the benefits are poorly quantified. Using a pilot-scale premise plumbing system, flushed shower outlets were evaluated against non-flushed outlets during simulated periods of both active and low water demand. Water and biofilm concentrations of total bacteria, Legionella spp., and Vermamoeba vermiformis were quantified using real-time quantitative PCR. Even after all outlets returned to active water demand, flushed shower outlets continued to have lower quantities of Legionella compared to non-flushed outlets for several days, but the decrease was of little practical benefit (10[copies/L]). During prolonged periods of low water demand, however, there was no apparent benefit to flushing. Total bacteria grew to stationary phase within 3 ± 1 days, while Legionella spp. took 12 ± 6 days, regardless of whether the pipes had recently been flushed or not. Flushing with hot or cold water had little to no effect on the concentrations of total bacteria and Legionella in pipe wall biofilms. Flushing with cold water (9.6 and 13.2°C) decreased total bacteria concentrations in the water by 0.96 and 1.00 log10[copies/L], respectively and by 1.27 and 1.74 log10[copies/L] with hot water (49 and 60°C, respectively) but the difference in Legionella spp. concentrations between flushing with cold (1.55 log10[copies/L] for both) and hot water (1.32 to 1.88 log10[copies/L], respectively) was negligible. This suggests that hot water flushing, even at 60°C, provides little or no added benefit for managing Legionella in non-chlorinated building plumbing systems versus cold water flushing. Finally, the immediate benefits of flushing in terms of reductions in total bacteria and Legionella in the water were comparable as well as the rates at which those populations recovered during post-flush or post-shower stagnation.
- 21 March 2023
- Published by Frontiers Media SA in Frontiers in Water
- Vol. 5
Open AccessThe benefits of flushing for mitigating Legionella spp. in non-chlorinated building plumbing systems
Flushing is a common corrective action recommended by Legionella management guidelines to remove stagnant water and replenish disinfectant. Due to water age and different local regulations, buildings may receive water with low or no residual disinfectant. In such situations, the evidence for flushing efficacy is often anecdotal, and the benefits are poorly quantified. Using a pilot-scale premise plumbing system, flushed shower outlets were evaluated against non-flushed outlets during simulated periods of both active and low water demand. Water and biofilm concentrations of total bacteria, Legionella spp., and Vermamoeba vermiformis were quantified using real-time quantitative PCR. Even after all outlets returned to active water demand, flushed shower outlets continued to have lower quantities of Legionella compared to non-flushed outlets for several days, but the decrease was of little practical benefit (10[copies/L]). During prolonged periods of low water demand, however, there was no apparent benefit to flushing. Total bacteria grew to stationary phase within 3 ± 1 days, while Legionella spp. took 12 ± 6 days, regardless of whether the pipes had recently been flushed or not. Flushing with hot or cold water had little to no effect on the concentrations of total bacteria and Legionella in pipe wall biofilms. Flushing with cold water (9.6 and 13.2°C) decreased total bacteria concentrations in the water by 0.96 and 1.00 log10[copies/L], respectively and by 1.27 and 1.74 log10[copies/L] with hot water (49 and 60°C, respectively) but the difference in Legionella spp. concentrations between flushing with cold (1.55 log10[copies/L] for both) and hot water (1.32 to 1.88 log10[copies/L], respectively) was negligible. This suggests that hot water flushing, even at 60°C, provides little or no added benefit for managing Legionella in non-chlorinated building plumbing systems versus cold water flushing. Finally, the immediate benefits of flushing in terms of reductions in total bacteria and Legionella in the water were comparable as well as the rates at which those populations recovered during post-flush or post-shower stagnation.
- 22 February 2023
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 57 (9) , 3833-3842
Multi-scale Investigation of Ammonia-Oxidizing Microorganisms in Biofilters Used for Drinking Water Treatment
Ammonia-oxidizing microorganisms (AOMs) include ammonia-oxidizing bacteria (AOB), archaea (AOA), and Nitrospira spp. sublineage II capable of complete ammonia oxidation (comammox). These organisms can affect water quality not only by oxidizing ammonia to nitrite (or nitrate) but also by cometabolically degrading trace organic contaminants. In this study, the abundance and composition of AOM communities were investigated in full-scale biofilters at 14 facilities across North America and in pilot-scale biofilters operated for 18 months at a full-scale water treatment plant. In general, the relative abundance of AOM in most full-scale biofilters and in the pilot-scale biofilters was as follows: AOB > comammox Nitrospira > AOA. The abundance of AOB in the pilot-scale biofilters increased with increasing influent ammonia concentration and decreasing temperature, whereas AOA and comammox Nitrospira exhibited no correlations with these parameters. The biofilters affected AOM abundance in the water passing through the filters via collecting and shedding but exhibited a minor influence on the composition of AOB and Nitrospira sublineage II communities in the filtrate. Overall, this study highlights the relative importance of AOB and comammox Nitrospira compared to AOA in biofilters and the influence of filter influent water quality on AOM in biofilters and their release into the filtrate.
- 22 February 2023
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 57 (9) , 3833-3842
Multi-scale Investigation of Ammonia-Oxidizing Microorganisms in Biofilters Used for Drinking Water Treatment
Ammonia-oxidizing microorganisms (AOMs) include ammonia-oxidizing bacteria (AOB), archaea (AOA), and Nitrospira spp. sublineage II capable of complete ammonia oxidation (comammox). These organisms can affect water quality not only by oxidizing ammonia to nitrite (or nitrate) but also by cometabolically degrading trace organic contaminants. In this study, the abundance and composition of AOM communities were investigated in full-scale biofilters at 14 facilities across North America and in pilot-scale biofilters operated for 18 months at a full-scale water treatment plant. In general, the relative abundance of AOM in most full-scale biofilters and in the pilot-scale biofilters was as follows: AOB > comammox Nitrospira > AOA. The abundance of AOB in the pilot-scale biofilters increased with increasing influent ammonia concentration and decreasing temperature, whereas AOA and comammox Nitrospira exhibited no correlations with these parameters. The biofilters affected AOM abundance in the water passing through the filters via collecting and shedding but exhibited a minor influence on the composition of AOB and Nitrospira sublineage II communities in the filtrate. Overall, this study highlights the relative importance of AOB and comammox Nitrospira compared to AOA in biofilters and the influence of filter influent water quality on AOM in biofilters and their release into the filtrate.
- Open Access
- 17 January 2023
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 3 (2) , 387-399
Determination of the Antibiotic and Antibiotic Resistance Footprint in Surface Water Environments of a Metropolitan Area: Effects of Anthropogenic Activities
- 17 January 2023
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 3 (2) , 387-399
Open AccessDetermination of the Antibiotic and Antibiotic Resistance Footprint in Surface Water Environments of a Metropolitan Area: Effects of Anthropogenic Activities
- Open Access
- 14 April 2022
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 2 (5) , 759-768
Variation of Legionella spp. with Lake Depth and Season in Two Norwegian Drinking Water Sources
- 14 April 2022
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 2 (5) , 759-768
Open AccessVariation of Legionella spp. with Lake Depth and Season in Two Norwegian Drinking Water Sources
- 1 October 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 147 (10) , 04021035
Evaluating Different Quantitative PCR Assays to Enumerate Specific Microbial Populations in Anaerobic Digesters Treating Municipal Wastewater Solids
The goal of this research was to use and to validate different quantitative polymerase chain reaction (qPCR) assays to quantify the pertinent microbial populations in full-scale anaerobic digesters at municipal wastewater treatment facilities. Methanomicrobiales ( of Archaea) and Methanosarcinales ( of Archaea) were the most dominant methanogenic orders in the mesophilic anaerobic digesters, whereas the Methanobacteriales ( of Archaea) were the most common in the thermophilic anaerobic digester. qPCR results were validated via comparisons with profiles of microbial community composition obtained by PCR-amplified 16S rRNA gene sequences. Exceptionally strong linear correlations ( ) were observed when comparing the microbiome profile with the qPCR results for Archaea, Methanomicrobiales, Methanosarcinales, Methanobacteriales, and Methanosarcinacea. In addition, core communities of both Bacteria and Archaea were observed in the mesophilic anaerobic digesters. This research demonstrates that monitoring microbial groups in full-scale anaerobic digesters is feasible via qPCR, providing the prerequisite tools needed to track and to understand microbial population dynamics in anaerobic digesters.- 1 October 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 147 (10) , 04021035
Evaluating Different Quantitative PCR Assays to Enumerate Specific Microbial Populations in Anaerobic Digesters Treating Municipal Wastewater Solids
The goal of this research was to use and to validate different quantitative polymerase chain reaction (qPCR) assays to quantify the pertinent microbial populations in full-scale anaerobic digesters at municipal wastewater treatment facilities. Methanomicrobiales ( of Archaea) and Methanosarcinales ( of Archaea) were the most dominant methanogenic orders in the mesophilic anaerobic digesters, whereas the Methanobacteriales ( of Archaea) were the most common in the thermophilic anaerobic digester. qPCR results were validated via comparisons with profiles of microbial community composition obtained by PCR-amplified 16S rRNA gene sequences. Exceptionally strong linear correlations ( ) were observed when comparing the microbiome profile with the qPCR results for Archaea, Methanomicrobiales, Methanosarcinales, Methanobacteriales, and Methanosarcinacea. In addition, core communities of both Bacteria and Archaea were observed in the mesophilic anaerobic digesters. This research demonstrates that monitoring microbial groups in full-scale anaerobic digesters is feasible via qPCR, providing the prerequisite tools needed to track and to understand microbial population dynamics in anaerobic digesters.- 1 October 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 147 (10) , 04021044
Evaluating Quantitative PCR Assays to Enumerate Several Bacterial Populations of Importance in Different Municipal Wastewater Treatment Designs
This study evaluated the efficacy of quantitative polymerase chain reaction (qPCR) to monitor several pertinent bacterial populations in 25 different full-scale wastewater treatment bioreactors across 9 different system designs. All the bioreactors contained a substantial quantity of total bacterial biomass and denitrifying bacteria, independent of system design. In contrast, the quantities of ammonia oxidizing bacteria (AOB) and phosphate accumulating organisms (PAOs) measured by qPCR targeting the amoA gene and the 16S rRNA genes, respectively, from the Candidatus Accumulibacter lineage significantly correlated with system design. Bioreactors with short mean cell residence time ( ) had significantly lower AOB abundance than most of the other bioreactors (all pairwise comparisons , except for a membrane-coupled bioreactor). Similarly, bioreactors designed for enhanced biological phosphorus removal had significantly higher relative quantities of PAOs than did conventional systems ( ). In conclusion, these qPCR assays should be practically useful for monitoring full-scale wastewater treatment bioreactors, thereby helping to improve process performance.- 1 October 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 147 (10) , 04021044
Evaluating Quantitative PCR Assays to Enumerate Several Bacterial Populations of Importance in Different Municipal Wastewater Treatment Designs
This study evaluated the efficacy of quantitative polymerase chain reaction (qPCR) to monitor several pertinent bacterial populations in 25 different full-scale wastewater treatment bioreactors across 9 different system designs. All the bioreactors contained a substantial quantity of total bacterial biomass and denitrifying bacteria, independent of system design. In contrast, the quantities of ammonia oxidizing bacteria (AOB) and phosphate accumulating organisms (PAOs) measured by qPCR targeting the amoA gene and the 16S rRNA genes, respectively, from the Candidatus Accumulibacter lineage significantly correlated with system design. Bioreactors with short mean cell residence time ( ) had significantly lower AOB abundance than most of the other bioreactors (all pairwise comparisons , except for a membrane-coupled bioreactor). Similarly, bioreactors designed for enhanced biological phosphorus removal had significantly higher relative quantities of PAOs than did conventional systems ( ). In conclusion, these qPCR assays should be practically useful for monitoring full-scale wastewater treatment bioreactors, thereby helping to improve process performance.