Zaenul Muhlisin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zaenul Muhlisin has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Asep Yoyo Wardaya
Department of Physics, Faculty of Science and Mathematics, Diponegoro University, Semarang, Indonesia
4 shared publications - Pandji Triadyaksa
Department of Physics, Faculty of Science and Mathematics, Diponegoro University, Semarang, Indonesia
4 shared publications - Susilo Hadi
Department of Physics, Faculty of Science and Mathematics, Diponegoro University, Semarang, Indonesia
4 shared publications - Jatmiko Endro Suseno
Diponegoro University
3 shared publications - Muhammad Nur
Department of Physics, Faculty of Science and Mathematics, Universitas Diponegoro, Tembalang, Semarang 50275, Indonesia
3 shared publications - Ali Khumaeni
Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Semarang, Indonesia
2 shared publications
Latest Publications
- Open Access
Advanced Oxidation Techniques and Hybrid Approaches for Microplastic Degradation: A Comprehensive Review
Microplastics (MPs) have emerged as persistent environmental pollutants with adverse effects on ecosystems and human health. Conventional removal methods, such as filtration and sedimentation, primarily rely on physical separation without addressing the degradation of MPs, leading to their accumulation and the risk of secondary pollution. This review explores the potential of advanced oxidation processes (AOPs), including photocatalysis, electrochemical oxidation, Fenton processes, sulfate radical-based oxidation, sonochemical treatment, ozonation, and plasma technologies, which generate reactive oxygen and nitrogen species capable of promoting polymer chain scission, microbial biodegradation, and the oxidative fragmentation and mineralization of MPs into non-toxic byproducts. Hybrid AOP systems combined with biological treatments or membrane-based filtration are also examined for their effectiveness in degrading MPs, as well as for scalability and the environmental impacts of their byproducts when integrated into existing wastewater treatment systems. The review further discusses challenges related to operational parameters, energy consumption, and the formation of secondary pollutants. By identifying current knowledge gaps and future research directions, this review provides insights into optimizing AOPs and integrations of AOPs with biological treatments or membrane-based processes for sustainable MP remediation and water treatment applications.
Open AccessAdvanced Oxidation Techniques and Hybrid Approaches for Microplastic Degradation: A Comprehensive Review
Microplastics (MPs) have emerged as persistent environmental pollutants with adverse effects on ecosystems and human health. Conventional removal methods, such as filtration and sedimentation, primarily rely on physical separation without addressing the degradation of MPs, leading to their accumulation and the risk of secondary pollution. This review explores the potential of advanced oxidation processes (AOPs), including photocatalysis, electrochemical oxidation, Fenton processes, sulfate radical-based oxidation, sonochemical treatment, ozonation, and plasma technologies, which generate reactive oxygen and nitrogen species capable of promoting polymer chain scission, microbial biodegradation, and the oxidative fragmentation and mineralization of MPs into non-toxic byproducts. Hybrid AOP systems combined with biological treatments or membrane-based filtration are also examined for their effectiveness in degrading MPs, as well as for scalability and the environmental impacts of their byproducts when integrated into existing wastewater treatment systems. The review further discusses challenges related to operational parameters, energy consumption, and the formation of secondary pollutants. By identifying current knowledge gaps and future research directions, this review provides insights into optimizing AOPs and integrations of AOPs with biological treatments or membrane-based processes for sustainable MP remediation and water treatment applications.
- 1 January 2026
- Published by Pleiades Publishing Ltd in Journal of Experimental and Theoretical Physics
- Vol. 142 (1) , 21-29
Effect of the Active Electrode Geometric Properties on Calculating the I–V Characteristics of the Corona Discharge
The motivation for this research is the need for practical and scalable current–voltage (I–V) characterization of plasma discharges in various plasma devices, such as electrostatic precipitators. Analytical calculations of DC corona discharge I–V characteristics using geometric properties are much simpler than physical calculation models. The novelty of this research is the use of a three-dimensional active electrode, with the space below the active electrode filled with air and a dielectric. The passive electrode is positioned horizontally at the lowest point of all electrode equipment systems. The use of geometric properties in plasma discharge is based on the massive plasma flow at the sharp bottom end of the active electrode, which is achieved by generating a sharpness factor of the form k, incorporated into the integration result of the modified capacitance calculation. Python graphical user interface (GUI) programming creates a simulation graph of the I‒V characteristics, with the k factor as the fitting parameter, and the standard deviation (SD) and t-test as the curve accuracy factors. There are three graphs for the hemispherical shell to plane (HS-P) configuration model and two graphs for the hemispherical bowl to plane (HSB-P) configuration model, with all graphs meeting a sufficient level of accuracy between the data points and the simulation curve (t-test value ≤ 0.05) with the best and worst curves being produced by the HS-P configuration model with a spherical shell radius of 0.04 m (SD = 0.8903) and 0.025 m (SD = 2.3399), respectively.
- 1 January 2026
- Published by Pleiades Publishing Ltd in Journal of Experimental and Theoretical Physics
- Vol. 142 (1) , 21-29
Effect of the Active Electrode Geometric Properties on Calculating the I–V Characteristics of the Corona Discharge
The motivation for this research is the need for practical and scalable current–voltage (I–V) characterization of plasma discharges in various plasma devices, such as electrostatic precipitators. Analytical calculations of DC corona discharge I–V characteristics using geometric properties are much simpler than physical calculation models. The novelty of this research is the use of a three-dimensional active electrode, with the space below the active electrode filled with air and a dielectric. The passive electrode is positioned horizontally at the lowest point of all electrode equipment systems. The use of geometric properties in plasma discharge is based on the massive plasma flow at the sharp bottom end of the active electrode, which is achieved by generating a sharpness factor of the form k, incorporated into the integration result of the modified capacitance calculation. Python graphical user interface (GUI) programming creates a simulation graph of the I‒V characteristics, with the k factor as the fitting parameter, and the standard deviation (SD) and t-test as the curve accuracy factors. There are three graphs for the hemispherical shell to plane (HS-P) configuration model and two graphs for the hemispherical bowl to plane (HSB-P) configuration model, with all graphs meeting a sufficient level of accuracy between the data points and the simulation curve (t-test value ≤ 0.05) with the best and worst curves being produced by the HS-P configuration model with a spherical shell radius of 0.04 m (SD = 0.8903) and 0.025 m (SD = 2.3399), respectively.
- Open Access
- 1 November 2023
- Published by Technoscience Academy in International Journal of Scientific Research in Science and Technology
- Vol. 10 (6) , 144-150
Photon Dose Distribution Analysis Using Three-Dimensional Conformal Radiation Therapy (3DCRT) And Intensity Modulated Radiotherapy (IMRT) Techniques in Cervical Cancer Cases Based on Histogram Volume Dose Curve (DVH)
Radiotherapy is one of the effective treatment methods for cervical cancer, although it is faced with great challenges in delivering an accurate dose of radiation. The purpose of this study was to compare the effectiveness of two cervical cancer treatment techniques, namely Three-Dimensional Conformal Radiation Therapy (3DCRT) and Intensity Modulated Radiotherapy (IMRT) in terms of conformity, homogeneity, and protection of Organs at Risk (OAR). The study used primary data from DVH 3DCRT and IMRT techniques collected from 15 cervical cancer patients. Conformity index (CI) and homogeneity (HI) were evaluated, and dose at OAR was assessed according to QUANTEC rules. The results showed the average CI value for the 3DCRT technique was (96,7 ± 1,5) x 10-2, while for IMRT it was (98,8 ± 0,8) x 10-2. In addition, the average HI score for the 3DCRT technique was (9,6 ± 1,5) x 10-2, and for IMRT it was (6,8 ± 1,9) x 10-2. In the 3DCRT technique, V50 for the rectum ranges from 0 – 57%, V65 for the bladder is 0%, and V50 for the left and right femoral heads ranges from 0 – 15.92% and 0 – 10.86%. While in the IMRT technique, V50 for the rectum ranges from 0 – 40,56%, V65 for bladder is 0%, and V50 for the left and right femoral heads ranges from 0 – 0,3% and 0 – 1,05%. The results of this study showed that the IMRT technique was better and more effective in treating cervical cancer than the 3DCRT technique. The IMRT technique has a higher CI value, indicating a better level of conformity, as well as a lower HI value, signifying a higher level of homogeneity. In addition, the IMRT technique is also able to provide better OAR protection.
- 1 November 2023
- Published by Technoscience Academy in International Journal of Scientific Research in Science and Technology
- Vol. 10 (6) , 144-150
Open AccessPhoton Dose Distribution Analysis Using Three-Dimensional Conformal Radiation Therapy (3DCRT) And Intensity Modulated Radiotherapy (IMRT) Techniques in Cervical Cancer Cases Based on Histogram Volume Dose Curve (DVH)
Radiotherapy is one of the effective treatment methods for cervical cancer, although it is faced with great challenges in delivering an accurate dose of radiation. The purpose of this study was to compare the effectiveness of two cervical cancer treatment techniques, namely Three-Dimensional Conformal Radiation Therapy (3DCRT) and Intensity Modulated Radiotherapy (IMRT) in terms of conformity, homogeneity, and protection of Organs at Risk (OAR). The study used primary data from DVH 3DCRT and IMRT techniques collected from 15 cervical cancer patients. Conformity index (CI) and homogeneity (HI) were evaluated, and dose at OAR was assessed according to QUANTEC rules. The results showed the average CI value for the 3DCRT technique was (96,7 ± 1,5) x 10-2, while for IMRT it was (98,8 ± 0,8) x 10-2. In addition, the average HI score for the 3DCRT technique was (9,6 ± 1,5) x 10-2, and for IMRT it was (6,8 ± 1,9) x 10-2. In the 3DCRT technique, V50 for the rectum ranges from 0 – 57%, V65 for the bladder is 0%, and V50 for the left and right femoral heads ranges from 0 – 15.92% and 0 – 10.86%. While in the IMRT technique, V50 for the rectum ranges from 0 – 40,56%, V65 for bladder is 0%, and V50 for the left and right femoral heads ranges from 0 – 0,3% and 0 – 1,05%. The results of this study showed that the IMRT technique was better and more effective in treating cervical cancer than the 3DCRT technique. The IMRT technique has a higher CI value, indicating a better level of conformity, as well as a lower HI value, signifying a higher level of homogeneity. In addition, the IMRT technique is also able to provide better OAR protection.
- Open Access
- 1 July 2023
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 31 (1) , 189-196
An improvement of the computational effective diameter measurement in thoracic computed tomography examinations
A method to calculate a corrected effective diameter (DMIL) to more accurately estimate the dose received by a patient in chest computed tomography (CT) examination had been previously proposed. However, the discrepancy between DMIL and water-equivalent diameter (Dw) is still relatively high (i.e. about 6%). Furthermore, the method is still performed manually, so it is laborious and time-consuming. This study aims to improve the corrected effective diameter with bone correction (Deffcorr) and to automatically calculate it. The automated Deffcorr was calculated as the square root of the product of these corrected AP and LAT diameters. The approach was implemented on 30 patients who had undergone chest CT examination with the standard protocol. The results show that the correlation between the Deffcorr and Dw is R2=0.93 with no statistical difference (p>0.05). The automated Deffcorr is 3.1% lower than Dw. While the DMIL is 10.5% higher than Dw and both are statistically different (p<0.05). In conclusion, the new Deffcorr was introduced and the result obtained was closer to Dw than DMIL. This method is simple enough to be used as an alternative method to accurately estimate Dw for radiation dose estimation in clinical chest CT scanning.
- 1 July 2023
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 31 (1) , 189-196
Open AccessAn improvement of the computational effective diameter measurement in thoracic computed tomography examinations
A method to calculate a corrected effective diameter (DMIL) to more accurately estimate the dose received by a patient in chest computed tomography (CT) examination had been previously proposed. However, the discrepancy between DMIL and water-equivalent diameter (Dw) is still relatively high (i.e. about 6%). Furthermore, the method is still performed manually, so it is laborious and time-consuming. This study aims to improve the corrected effective diameter with bone correction (Deffcorr) and to automatically calculate it. The automated Deffcorr was calculated as the square root of the product of these corrected AP and LAT diameters. The approach was implemented on 30 patients who had undergone chest CT examination with the standard protocol. The results show that the correlation between the Deffcorr and Dw is R2=0.93 with no statistical difference (p>0.05). The automated Deffcorr is 3.1% lower than Dw. While the DMIL is 10.5% higher than Dw and both are statistically different (p<0.05). In conclusion, the new Deffcorr was introduced and the result obtained was closer to Dw than DMIL. This method is simple enough to be used as an alternative method to accurately estimate Dw for radiation dose estimation in clinical chest CT scanning.
- 20 April 2022
- Published by EDP Sciences in The European Physical Journal Applied Physics
- Vol. 97, 22
The electrode model of corona plasma discharge theory for current–voltage characteristics case in air
The calculation of the electrode model in the corona plasma discharge case has been carried out using the semi-ellipse line to plane (S-ELTP) configuration model in the air. The final focus of this research is to calculate the (I–V) current–voltage characteristics of the plasmas discharge. Part of the work in the (I–V) characteristics includes computational calculations and carrying out experimental activities. Experimental data include current vs voltage variations that occur at the time of plasma discharge. All the discharge processes are generated by a positive DC voltage source. The arrangement of the geometric configuration of the electrodes consists of two plates in the form of a half ellipse (active electrode) and a rectangular plate (passive electrode) in a mutually perpendicular position. The size variation of the active electrode includes variations of the small and large size plates with each plate having two variations in the distance between the two electrodes. The calculation concept of the electrode model is to insert the certain shape sharpness factor of k in the numerical calculation in the sharp electrode capacitance part. The k factor value is obtained by calculating the fitting between numerical simulation and research data. The research results prove that there is a fairly high level of conformity between numerical simulation and the research data. Simulation calculation for the (I–V) characteristic curve and its level of accuracy used Python GUI Programming.
- 20 April 2022
- Published by EDP Sciences in The European Physical Journal Applied Physics
- Vol. 97, 22
The electrode model of corona plasma discharge theory for current–voltage characteristics case in air
The calculation of the electrode model in the corona plasma discharge case has been carried out using the semi-ellipse line to plane (S-ELTP) configuration model in the air. The final focus of this research is to calculate the (I–V) current–voltage characteristics of the plasmas discharge. Part of the work in the (I–V) characteristics includes computational calculations and carrying out experimental activities. Experimental data include current vs voltage variations that occur at the time of plasma discharge. All the discharge processes are generated by a positive DC voltage source. The arrangement of the geometric configuration of the electrodes consists of two plates in the form of a half ellipse (active electrode) and a rectangular plate (passive electrode) in a mutually perpendicular position. The size variation of the active electrode includes variations of the small and large size plates with each plate having two variations in the distance between the two electrodes. The calculation concept of the electrode model is to insert the certain shape sharpness factor of k in the numerical calculation in the sharp electrode capacitance part. The k factor value is obtained by calculating the fitting between numerical simulation and research data. The research results prove that there is a fairly high level of conformity between numerical simulation and the research data. Simulation calculation for the (I–V) characteristic curve and its level of accuracy used Python GUI Programming.
- 1 January 2022
- Published by Gazi University Journal of Science in Gazi University Journal of Science
- Vol. 35 (3) , 1140-1150
The Current-Voltage Characteristics for Electrode Geometry Model of Positive DC Corona Discharge in Air
Research on corona plasma discharges from plasma reactors has been carried out using the Point and Semicircular-Plane (PSC-P) electrode configuration in the air. The purpose of this study is to compare the suitability level of the current-voltage (I-V) characteristics curve from the results of experimental data and numerical simulation calculations of the electrode geometry function based on the variation of three electrode configuration sizes (small plate, medium plate, and large plate) and two variations of the distance between the two electrodes in each electrode configuration size. The results of the study prove that there is a high degree of conformity between numerical calculations with experimental data through calculations from the Python GUI Programming by taking a fitting value from the certain k-shape sharpness factor. The calculation location of the kshape sharpness factor lies on the electrode tip sharp surface which will produce the largest plasma flow in the plasma reactor equipment.
- 1 January 2022
- Published by Gazi University Journal of Science in Gazi University Journal of Science
- Vol. 35 (3) , 1140-1150
The Current-Voltage Characteristics for Electrode Geometry Model of Positive DC Corona Discharge in Air
Research on corona plasma discharges from plasma reactors has been carried out using the Point and Semicircular-Plane (PSC-P) electrode configuration in the air. The purpose of this study is to compare the suitability level of the current-voltage (I-V) characteristics curve from the results of experimental data and numerical simulation calculations of the electrode geometry function based on the variation of three electrode configuration sizes (small plate, medium plate, and large plate) and two variations of the distance between the two electrodes in each electrode configuration size. The results of the study prove that there is a high degree of conformity between numerical calculations with experimental data through calculations from the Python GUI Programming by taking a fitting value from the certain k-shape sharpness factor. The calculation location of the kshape sharpness factor lies on the electrode tip sharp surface which will produce the largest plasma flow in the plasma reactor equipment.
- Open Access
- 11 June 2021
- Published by Universitas Multimedia Nusantara in Ultima Computing : Jurnal Sistem Komputer
- Vol. 13 (1) , 22-29
Perancangan Alat Karakterisasi Dioda dengan ESP32 dan Rangkaian Op-Amp LM358 Berbasis Android
Pada penelitian ini telah berhasil membuat sebuah alat uji karakterisasi bias maju dioda menggunakan ADC dan DAC internal mikrokontroler ESP32. Tegangan keluaran DAC ditambahkan dengan rangkaian penguat op-amp tak membalik LM358 sebesar 2 kali. Sehingga hasil pengujian tegangan keluaran DAC dapat mencapai nilai maksimum 6,3 volt sebagai sumber catu daya DC variabel rangkaian uji karakteristik bias maju dioda. Pengujian karakterisasi bias maju dioda dilakukan melalui antarmuka perangkat smartphone android dengan jaringan WiFi dan diperoleh kurva grafik karakterisasi bias maju yang memiliki nilai dan bentuk hampir sama dengan pengujian secara manual. Pengujian karakterisasi bias maju dioda menggunakan aplikasi ini lebih cepat daripada menggunakan pengukuran secara manual dengan alat ukur multimeter. Berdasarkan pengujian yang dilakukan menggunakan aplikasi smartphone android sebanyak 3 kali diperoleh rata-rata waktu sebesar 30 detik, sedangkan secara manual menggunakan alat ukur diperoleh rata-rata waktu sebesar 657,7 detik.
- 11 June 2021
- Published by Universitas Multimedia Nusantara in Ultima Computing : Jurnal Sistem Komputer
- Vol. 13 (1) , 22-29
Open AccessPerancangan Alat Karakterisasi Dioda dengan ESP32 dan Rangkaian Op-Amp LM358 Berbasis Android
Pada penelitian ini telah berhasil membuat sebuah alat uji karakterisasi bias maju dioda menggunakan ADC dan DAC internal mikrokontroler ESP32. Tegangan keluaran DAC ditambahkan dengan rangkaian penguat op-amp tak membalik LM358 sebesar 2 kali. Sehingga hasil pengujian tegangan keluaran DAC dapat mencapai nilai maksimum 6,3 volt sebagai sumber catu daya DC variabel rangkaian uji karakteristik bias maju dioda. Pengujian karakterisasi bias maju dioda dilakukan melalui antarmuka perangkat smartphone android dengan jaringan WiFi dan diperoleh kurva grafik karakterisasi bias maju yang memiliki nilai dan bentuk hampir sama dengan pengujian secara manual. Pengujian karakterisasi bias maju dioda menggunakan aplikasi ini lebih cepat daripada menggunakan pengukuran secara manual dengan alat ukur multimeter. Berdasarkan pengujian yang dilakukan menggunakan aplikasi smartphone android sebanyak 3 kali diperoleh rata-rata waktu sebesar 30 detik, sedangkan secara manual menggunakan alat ukur diperoleh rata-rata waktu sebesar 657,7 detik.
- Open Access
- 24 May 2021
- Published by Institute of Research and Community Services Diponegoro University (LPPM UNDIP) in Journal of Physics and Its Applications
- Vol. 3 (2) , 165-169
Improving water absorption time and the natural silk strength (Bombyx Mori) using atmospheric dielectric barrier discharge plasma
This researchaimed to obtain Dielectric Barrier Discharge plasma discharge characteristics with and without the placement of natural silkBombyx Mori on one of the electrodes. Furthermore, the strength and the water absorption time of the irradiated silk samples will be analyzed. Plasma discharge is generated by connecting electrodes of point-to-plane configuration with a sheet of glass inserted on the plane electrode at atmospheric conditions. The characterization of plasma discharge, either with or without the natural silk samples' placement on the plane electrode, was performed by increasing A.C.'s high voltage power source to reach arch discharge. Theelectrode spacing varied from 0.7 cm to 2.5 cm with a 0.3 cm increment. Sample irradiation was performed using cold plasma for 5, 15, and 30 minutes respectively. Placing or not placing the natural silk samples on the plane electrode will increase the plasma's discharge current and increase the high voltage. Moreover, increasing the distance between the electrodes and placing the sample on the plane electrode decreases the discharge current. Using Scanning Electron Microscopy, it was found that increasing plasma irradiation time on samples decreases the silk thread'sdiameterand shortening its water absorption time. The strength of irradiated fabric was reduceduntil 15 minutes of irradiation. However, at 30 minutes of irradiation, there was an increase in sample thickness compared to control samples.
- 24 May 2021
- Published by Institute of Research and Community Services Diponegoro University (LPPM UNDIP) in Journal of Physics and Its Applications
- Vol. 3 (2) , 165-169
Open AccessImproving water absorption time and the natural silk strength (Bombyx Mori) using atmospheric dielectric barrier discharge plasma
This researchaimed to obtain Dielectric Barrier Discharge plasma discharge characteristics with and without the placement of natural silkBombyx Mori on one of the electrodes. Furthermore, the strength and the water absorption time of the irradiated silk samples will be analyzed. Plasma discharge is generated by connecting electrodes of point-to-plane configuration with a sheet of glass inserted on the plane electrode at atmospheric conditions. The characterization of plasma discharge, either with or without the natural silk samples' placement on the plane electrode, was performed by increasing A.C.'s high voltage power source to reach arch discharge. Theelectrode spacing varied from 0.7 cm to 2.5 cm with a 0.3 cm increment. Sample irradiation was performed using cold plasma for 5, 15, and 30 minutes respectively. Placing or not placing the natural silk samples on the plane electrode will increase the plasma's discharge current and increase the high voltage. Moreover, increasing the distance between the electrodes and placing the sample on the plane electrode decreases the discharge current. Using Scanning Electron Microscopy, it was found that increasing plasma irradiation time on samples decreases the silk thread'sdiameterand shortening its water absorption time. The strength of irradiated fabric was reduceduntil 15 minutes of irradiation. However, at 30 minutes of irradiation, there was an increase in sample thickness compared to control samples.
- Open Access
- 3 May 2021
- Published by Institute of Research and Community Services Diponegoro University (LPPM UNDIP) in Journal of Physics and Its Applications
- Vol. 3 (2) , 155-164
Comparison of I-V Curves Between the Experiment of Corona Discharge on Gradient Line-To-Plane (GL-P) Configuration and The Mathematical Approach
Research has been conducted on the comparison of the I-V characteristic curve between mathematical study and experiment of the generation of negative DC corona discharge in the Gradient Line-to-Plane (GL-P) electrode configuration. The reason for this research is to calculate the suitability of the corona discharge electrical current between the mathematical and experimental study. The active electrode used has length 2 cm and height 4 cm. This research is conducted with variations in the sharpness angle of the active electrode (θ) 300, 450, and 600 and variations in the distance between the electrodes () 2 cm, 3 cm, and 4 cm. The mathematical formulation of the value of the corona discharge electrical current in the configuration of the GL-P electrode is obtained by using the geometric concept approach, which is the formulation of the capacitance value of the ordinary electrical circuit, with the addition of the multiplication factor value k in the sharp area of the active electrode, because in that area the greatest plasma flow distance is obtained. The value of the multiplication factor is obtained by fitting the curve between mathematical study and experiments. The I-V curve between the mathematical study and the corona discharge generation experiment has a high degree of similarity with the smallest percentage contacting point of 37.50%.The value of the multiplication factor is influenced by the sharpness angle of the active electrode shape and the distance between the electrodes.
- 3 May 2021
- Published by Institute of Research and Community Services Diponegoro University (LPPM UNDIP) in Journal of Physics and Its Applications
- Vol. 3 (2) , 155-164
Open AccessComparison of I-V Curves Between the Experiment of Corona Discharge on Gradient Line-To-Plane (GL-P) Configuration and The Mathematical Approach
Research has been conducted on the comparison of the I-V characteristic curve between mathematical study and experiment of the generation of negative DC corona discharge in the Gradient Line-to-Plane (GL-P) electrode configuration. The reason for this research is to calculate the suitability of the corona discharge electrical current between the mathematical and experimental study. The active electrode used has length 2 cm and height 4 cm. This research is conducted with variations in the sharpness angle of the active electrode (θ) 300, 450, and 600 and variations in the distance between the electrodes () 2 cm, 3 cm, and 4 cm. The mathematical formulation of the value of the corona discharge electrical current in the configuration of the GL-P electrode is obtained by using the geometric concept approach, which is the formulation of the capacitance value of the ordinary electrical circuit, with the addition of the multiplication factor value k in the sharp area of the active electrode, because in that area the greatest plasma flow distance is obtained. The value of the multiplication factor is obtained by fitting the curve between mathematical study and experiments. The I-V curve between the mathematical study and the corona discharge generation experiment has a high degree of similarity with the smallest percentage contacting point of 37.50%.The value of the multiplication factor is influenced by the sharpness angle of the active electrode shape and the distance between the electrodes.