Lorenzo Appendini
Research Subjects
Lorenzo Appendini has a total of 142 co-authors. Here are the top co-authors by number of shared publications:
A Patessio
8 shared publicationsC F Donner
8 shared publicationsClaudio F. Donner
Mondomedico, Multidisciplinary and Outpatient Rehabilitation Clinic, Borgomanero, Novara, Italy; and
7 shared publications- Mauro Carone
Istituti Clinici Scientifici Maugeri IRCCS, Respiratory Rehabilitation of the Institute of Bari; Department of Medical and Surgical Science, University of Foggia
7 shared publications Andrea Rossi
6 shared publicationsS Zanaboni
6 shared publications
Latest Publications
- Open Access
- 24 October 2024
- Published by Taylor & Francis in Pulmonology
- Vol. 31 (1)
Performance of helmet CPAP using different configurations: Turbine-driven ventilators vs Venturi devices
Traditionally, Venturi-based flow generators have been preferred over mechanical ventilators to provide continuous positive airway pressure (CPAP) through the helmet (h-CPAP). Recently, modern turbine-driven ventilators (TDVs) showed to be safe and effective in delivering h-CPAP. We aimed to compare the pressure stability during h-CPAP delivered by Venturi devices and TDVs and assess the impact of High Efficiency Particulate Air (HEPA) filters on their performance. We performed a bench study using an artificial lung simulator set in a restrictive respiratory condition, simulating two different levels of patient effort (high and low) with and without the interposition of the HEPA filter. We calculated the average of minimal (Pmin), maximal (Pmax) and mean (Pmean) airway pressure and the time product measured on the airway pressure curve (PTPinsp). We defined the pressure swing (Pswing) as Pmax - Pmin and pressure drop (Pdrop) as End Expiratory Pressure - Pmin. Pswing across CPAP levels varied widely among all the tested devices. During "low effort", no difference in Pswing and Pdrop was found between Venturi devices and TDVs; during high effort, Pswing (p<0.001) and Pdrop (p<0.001) were significantly higher in TDVs compared to Venturi devices, but the PTPinsp was lower (1.50 SD 0.54 vs 1.67 SD 0.55, p<0.001). HEPA filter addition almost doubled Pswing and PTPinsp (p<0.001) but left unaltered the differences among Venturi and TDVs systems in favor of the latter (p<0.001). TDVs performed better than Venturi systems in delivering a stable positive pressure level during h-CPAP in a bench setting.
- 24 October 2024
- Published by Taylor & Francis in Pulmonology
- Vol. 31 (1)
Open AccessPerformance of helmet CPAP using different configurations: Turbine-driven ventilators vs Venturi devices
Traditionally, Venturi-based flow generators have been preferred over mechanical ventilators to provide continuous positive airway pressure (CPAP) through the helmet (h-CPAP). Recently, modern turbine-driven ventilators (TDVs) showed to be safe and effective in delivering h-CPAP. We aimed to compare the pressure stability during h-CPAP delivered by Venturi devices and TDVs and assess the impact of High Efficiency Particulate Air (HEPA) filters on their performance. We performed a bench study using an artificial lung simulator set in a restrictive respiratory condition, simulating two different levels of patient effort (high and low) with and without the interposition of the HEPA filter. We calculated the average of minimal (Pmin), maximal (Pmax) and mean (Pmean) airway pressure and the time product measured on the airway pressure curve (PTPinsp). We defined the pressure swing (Pswing) as Pmax - Pmin and pressure drop (Pdrop) as End Expiratory Pressure - Pmin. Pswing across CPAP levels varied widely among all the tested devices. During "low effort", no difference in Pswing and Pdrop was found between Venturi devices and TDVs; during high effort, Pswing (p<0.001) and Pdrop (p<0.001) were significantly higher in TDVs compared to Venturi devices, but the PTPinsp was lower (1.50 SD 0.54 vs 1.67 SD 0.55, p<0.001). HEPA filter addition almost doubled Pswing and PTPinsp (p<0.001) but left unaltered the differences among Venturi and TDVs systems in favor of the latter (p<0.001). TDVs performed better than Venturi systems in delivering a stable positive pressure level during h-CPAP in a bench setting.
- 29 August 2023
- Published by Springer Nature
- p. 331-357
Noninvasive Mechanical Ventilation in COPD Exacerbations
- 29 August 2023
- Published by Springer Nature
- p. 331-357
Noninvasive Mechanical Ventilation in COPD Exacerbations
- 28 September 2019
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 54 (suppl 63) , PA5424
Electric impedance tomography discriminates asthmatics during methacholine challenge test
Background: Bronchial asthma is not always easily diagnosed in children because of poor compliance performing spirometric manoeuvres. Little is known about the distribution of pulmonary regional ventilation in these patients. Electric Impedance Tomography (EIT) is a technique where the electrical conductivity and impedance of ventilation is inferred from surface electrodes to form a tomographic image. Objectives: This study aims to determine the role of EIT to investigate the distribution of ventilation during methacholine challenge test (MCT) in order to discriminate healthy from asthmatic patients. Methods: Patients from 5 to 16 years old were enrolled. Positive MCT was defined as a reduction of FEV1 ≥20%. For each patient, spirometry and EIT were assessed at baseline (B), at PD20 (or Step 6 of the MCT) and 10 minutes after administration of the bronchodilator. Results: 36 positive and 7 negative patients were found. Positive group at PD20 showed a significant air trapping (550 ±180 ml, p<0.0001) and its subsequent reduction to baseline values after bronchodilation. Negative group did not show significant end-expiratory volume changes despite methacholine, indicating that air trapping is a specific feature of the asthmatic patients. Air trapping had a homogeneous distribution in the lungs and, according to its bigger amount and faster onset, it was possible to identify a subgroup of severe patients. Conclusions: EIT is a good tool to evaluate regional pulmonary ventilation without requiring collaboration. It could be useful to identify an early air trapping in patients with methacholine challenge test and, possibly, discriminate severe asthmatic in order to administer specific therapy.
- 28 September 2019
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 54 (suppl 63) , PA5424
Electric impedance tomography discriminates asthmatics during methacholine challenge test
Background: Bronchial asthma is not always easily diagnosed in children because of poor compliance performing spirometric manoeuvres. Little is known about the distribution of pulmonary regional ventilation in these patients. Electric Impedance Tomography (EIT) is a technique where the electrical conductivity and impedance of ventilation is inferred from surface electrodes to form a tomographic image. Objectives: This study aims to determine the role of EIT to investigate the distribution of ventilation during methacholine challenge test (MCT) in order to discriminate healthy from asthmatic patients. Methods: Patients from 5 to 16 years old were enrolled. Positive MCT was defined as a reduction of FEV1 ≥20%. For each patient, spirometry and EIT were assessed at baseline (B), at PD20 (or Step 6 of the MCT) and 10 minutes after administration of the bronchodilator. Results: 36 positive and 7 negative patients were found. Positive group at PD20 showed a significant air trapping (550 ±180 ml, p<0.0001) and its subsequent reduction to baseline values after bronchodilation. Negative group did not show significant end-expiratory volume changes despite methacholine, indicating that air trapping is a specific feature of the asthmatic patients. Air trapping had a homogeneous distribution in the lungs and, according to its bigger amount and faster onset, it was possible to identify a subgroup of severe patients. Conclusions: EIT is a good tool to evaluate regional pulmonary ventilation without requiring collaboration. It could be useful to identify an early air trapping in patients with methacholine challenge test and, possibly, discriminate severe asthmatic in order to administer specific therapy.
- 1 August 2018
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 198 (3) , 392-396
A New Ultrasound Method for Estimating Dynamic Intrinsic Positive Airway Pressure: A Prospective Clinical Trial
- 1 August 2018
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 198 (3) , 392-396
A New Ultrasound Method for Estimating Dynamic Intrinsic Positive Airway Pressure: A Prospective Clinical Trial
- 1 June 2017
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 153 (6) , 1468-1475
Endothelin inhibitors lower pulmonary vascular resistance and improve functional capacity in patients with Fontan circulation
- 1 June 2017
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 153 (6) , 1468-1475
Endothelin inhibitors lower pulmonary vascular resistance and improve functional capacity in patients with Fontan circulation
- Open Access
- 1 January 2017
- Published by Elsevier in Brazilian Journal of Physical Therapy
- Vol. 21 (1) , 15-23
Comparing airways clearance techniques in chronic obstructive pulmonary disease and bronchiectasis: positive expiratory pressure or temporary positive expiratory pressure? A retrospective study
- 1 January 2017
- Published by Elsevier in Brazilian Journal of Physical Therapy
- Vol. 21 (1) , 15-23
Open AccessComparing airways clearance techniques in chronic obstructive pulmonary disease and bronchiectasis: positive expiratory pressure or temporary positive expiratory pressure? A retrospective study
- 1 May 2016
- Published by SAGE Publications in Respiratory Care
- Vol. 61 (5) , 720-721
PEEP and Mechanical Ventilation: We Are Warned, We Cannot Ignore
- 1 May 2016
- Published by SAGE Publications in Respiratory Care
- Vol. 61 (5) , 720-721
PEEP and Mechanical Ventilation: We Are Warned, We Cannot Ignore
- 1 November 2011
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 39 (11) , 2566-2568
Ventilator waveforms-based patient–ventilator asynchrony detection: Valuable tool or a pipe dream in the clinical setting?*
- 1 November 2011
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 39 (11) , 2566-2568
Ventilator waveforms-based patient–ventilator asynchrony detection: Valuable tool or a pipe dream in the clinical setting?*
- Open Access
- 11 August 2011
- Published by S. Karger AG in Respiration
- Vol. 83 (5) , 383-390
High-Resolution Computed Tomography Quantitation of Emphysema Is Correlated with Selected Lung Function Values in Stable COPD
Background: The literature shows conflicting results when high-resolution computed tomography (HRCT) scores of emphysema were correlated with different indices of airflow obstruction. Objectives: We correlated HRCT scores of emphysema with different indices of airflow obstruction. Methods: We performed HRCT of the chest in 59 patients, all smokers or ex-smokers, with stable chronic obstructive pulmonary disease of different severity [GOLD stages I–IV; mean age ± SD 67.8 ± 7.3 years; pack/years 51.0 ± 34.6; percent predicted forced expiratory volume in 1 s (FEV1% predicted) 52.3 ± 17.6; post-bronchodilator FEV1% predicted 56.5 ± 19.1; FEV1/forced vital capacity (FVC) ratio 50.8 ± 10.2; post-bronchodilator FEV1/FVC ratio 51.6 ± 11.0; percent diffusion lung capacity for carbon monoxide (DLCO%) 59.2 ± 21.1; DLCO/percent alveolar volume (VA%) 54.5 ± 18.2; percent residual volume 163.0 ± 35.6; percent total lung capacity (TLC%) 113.2 ± 15; residual volume/TLC 1.44 ± 0.2]. All patients were in stable phase. Results: The mean ± SD visual emphysema score in all patients was 25.6 ± 25.4%. There was a weak but significant correlation between the percentage of pulmonary emphysema and numbers of pack/years (R = +0.31, p = 0.024). The percentage of emphysema was inversely correlated with the FEV1/FVC ratio before and after bronchodilator use (R = –0.44, p = 0.002, and R = –0.39, p = 0.005), DLCO% (R = –0.64, p = 0.0003) and DLCO/VA% (R = –0.68, p < 0.0001). A weak positive correlation was also found with TLC% (R = +0.28, p = 0.048). When patients with documented emphysema were considered separately, the best significant correlation observed was between DLCO/VA% and HRCT scan score (p = 0.007). Conclusions: These data suggest that in patients with stable chronic obstructive pulmonary disease of varying severity, the presence of pulmonary emphysema is best represented by the impaired gas exchange capability of the respiratory system.
- 11 August 2011
- Published by S. Karger AG in Respiration
- Vol. 83 (5) , 383-390
Open AccessHigh-Resolution Computed Tomography Quantitation of Emphysema Is Correlated with Selected Lung Function Values in Stable COPD
Background: The literature shows conflicting results when high-resolution computed tomography (HRCT) scores of emphysema were correlated with different indices of airflow obstruction. Objectives: We correlated HRCT scores of emphysema with different indices of airflow obstruction. Methods: We performed HRCT of the chest in 59 patients, all smokers or ex-smokers, with stable chronic obstructive pulmonary disease of different severity [GOLD stages I–IV; mean age ± SD 67.8 ± 7.3 years; pack/years 51.0 ± 34.6; percent predicted forced expiratory volume in 1 s (FEV1% predicted) 52.3 ± 17.6; post-bronchodilator FEV1% predicted 56.5 ± 19.1; FEV1/forced vital capacity (FVC) ratio 50.8 ± 10.2; post-bronchodilator FEV1/FVC ratio 51.6 ± 11.0; percent diffusion lung capacity for carbon monoxide (DLCO%) 59.2 ± 21.1; DLCO/percent alveolar volume (VA%) 54.5 ± 18.2; percent residual volume 163.0 ± 35.6; percent total lung capacity (TLC%) 113.2 ± 15; residual volume/TLC 1.44 ± 0.2]. All patients were in stable phase. Results: The mean ± SD visual emphysema score in all patients was 25.6 ± 25.4%. There was a weak but significant correlation between the percentage of pulmonary emphysema and numbers of pack/years (R = +0.31, p = 0.024). The percentage of emphysema was inversely correlated with the FEV1/FVC ratio before and after bronchodilator use (R = –0.44, p = 0.002, and R = –0.39, p = 0.005), DLCO% (R = –0.64, p = 0.0003) and DLCO/VA% (R = –0.68, p < 0.0001). A weak positive correlation was also found with TLC% (R = +0.28, p = 0.048). When patients with documented emphysema were considered separately, the best significant correlation observed was between DLCO/VA% and HRCT scan score (p = 0.007). Conclusions: These data suggest that in patients with stable chronic obstructive pulmonary disease of varying severity, the presence of pulmonary emphysema is best represented by the impaired gas exchange capability of the respiratory system.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2011 (1094687X) , 3808-3811
Noninvasive method for measuring respiratory system compliance during pressure support ventilation
Purpose: To date, few methods have been accepted for assessing the respiratory system compliance (C rs ) in patients under assisted ventilation at the bedside. The aim of this study was to evaluate our adaptive time slice method (ATSM) to continuously calculate the C rs . Methods: One breath is divided into several time periods (slices). For each slice, a compliance value C i is calculated. The slice width is adapted according to the confidence interval of C i . After all C i values are obtained and the outliers are eliminated, the C rs of this breath is calculated as the mean value of the remainder of C i 's. Seven patients with Chronic Obstructive Pulmonary Disease were evaluated during pressure support ventilation. The results are compared with the values calculated with the transdiaphragmatic pressure (P di ). Results: 95±4% of the recorded data could be analyzed with ATSM. In 6 patients out of 7, the results delivered with ATSM and with P di had similar variation (standard deviation) and accuracy (difference<;20%). They were strongly correlated (weighted correlation coefficient = 0.86, p<;10 -5 ) with a mean difference of 3.22 ml/mbar. Conclusions: The ATSM is a robust method and able to provide accurate C rs in spontaneously breathing patients during pressure support ventilation noninvasively without extra instrumentation or complicated maneuvers.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2011 (1094687X) , 3808-3811
Noninvasive method for measuring respiratory system compliance during pressure support ventilation
Purpose: To date, few methods have been accepted for assessing the respiratory system compliance (C rs ) in patients under assisted ventilation at the bedside. The aim of this study was to evaluate our adaptive time slice method (ATSM) to continuously calculate the C rs . Methods: One breath is divided into several time periods (slices). For each slice, a compliance value C i is calculated. The slice width is adapted according to the confidence interval of C i . After all C i values are obtained and the outliers are eliminated, the C rs of this breath is calculated as the mean value of the remainder of C i 's. Seven patients with Chronic Obstructive Pulmonary Disease were evaluated during pressure support ventilation. The results are compared with the values calculated with the transdiaphragmatic pressure (P di ). Results: 95±4% of the recorded data could be analyzed with ATSM. In 6 patients out of 7, the results delivered with ATSM and with P di had similar variation (standard deviation) and accuracy (difference<;20%). They were strongly correlated (weighted correlation coefficient = 0.86, p<;10 -5 ) with a mean difference of 3.22 ml/mbar. Conclusions: The ATSM is a robust method and able to provide accurate C rs in spontaneously breathing patients during pressure support ventilation noninvasively without extra instrumentation or complicated maneuvers.