K. P. Swaroop
K. P. Swaroop has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Durga Prasad Garapati
Shri Vishnu Engineering College for Women, India
2 shared publications - Praveen Kumar Nalli
Department of Artificial Intelligence, Shri Vishnu Engineering College for Women, India
2 shared publications - Ramu Bhukya
Department of EEE, Shri Vishnu Engineering College for Women (Autonomous) Bhimavaram, Bhimavaram, India
2 shared publications - Sssr Sarathbabu Duvvuri
Department of EEE, Shri Vishnu Engineering College for Women (Autonomous) Bhimavaram, Bhimavaram, India
2 shared publications V. Jegathesan
Department of EEE, Karunya Institute of Technology and Sciences, Coimbatore, India
2 shared publicationsA. Sireesha
1 shared publication
Latest Publications
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Newfangled Multilevel Inverter fed V/f Controlled Induction Motor Drive with Multicarrier PWM Strategy
In the modern industrial drive system, power electronic converters are employed not only to control the electromechanical energy conversion process, but also facilitate energy efficiency and continued automation. In the drive system, induction motor (IM) is a preferred energy conversion device because of its inherent features. Nowadays, power converters using MLI's playing vital role in the energy conversion process also multilevel configuration allow raising the power-handling capability of the system. Thus, in this paper fifteen level cascaded MLI fed closed loop V/f controlled IM drive is developed and its performance indicators have been analyzed for multicarrier carrier PWM strategy executed using MATLAB/Simulink.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Newfangled Multilevel Inverter fed V/f Controlled Induction Motor Drive with Multicarrier PWM Strategy
In the modern industrial drive system, power electronic converters are employed not only to control the electromechanical energy conversion process, but also facilitate energy efficiency and continued automation. In the drive system, induction motor (IM) is a preferred energy conversion device because of its inherent features. Nowadays, power converters using MLI's playing vital role in the energy conversion process also multilevel configuration allow raising the power-handling capability of the system. Thus, in this paper fifteen level cascaded MLI fed closed loop V/f controlled IM drive is developed and its performance indicators have been analyzed for multicarrier carrier PWM strategy executed using MATLAB/Simulink.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Fault Diagnosis of the Newfangled Cascaded H-Bridge Multilevel Inverter
In recent years multilevel inverters have been extensively worn in high voltage and high power applications for their unique performance. Reliability of the power electronic equipment is very essential to make sure that inverter operation should be stable and it is most important to detect and locate the faults as speedily as possible. This paper deals with open switch-fault finding method in a multilevel inverter using wavelet transformation tool. A fault diagnosis procedure is proposed and executed using MATLAB.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Fault Diagnosis of the Newfangled Cascaded H-Bridge Multilevel Inverter
In recent years multilevel inverters have been extensively worn in high voltage and high power applications for their unique performance. Reliability of the power electronic equipment is very essential to make sure that inverter operation should be stable and it is most important to detect and locate the faults as speedily as possible. This paper deals with open switch-fault finding method in a multilevel inverter using wavelet transformation tool. A fault diagnosis procedure is proposed and executed using MATLAB.
- 1 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 1-7
Generalized cascaded Multi Level Inverter using reduced number of components with PV systems
A Multi Level Inverter (MLI) has numerous industrial applications over a conventional two-level inverter due to its attractive features like it produces staircase output waveform with very lower distortion, it has less dv/dt stresses on switches, it operates effectively in both symmetric and asymmetric states, it performs at lower switching frequency and hence lower switching loss, etc. But, unfortunately, it needs greater number of power semiconductor switches and associated gate drive circuits. So, it may cause the overall system to be more complex and expensive. This paper presents a new topology of MLI with reduced number of semi conductor switches typically called as generalized cascaded MLI (with constant DC voltage sources). It can be analysed in both symmetric and asymmetric states by considering different criteria for optimal structures such as minimum number of DC sources, gate driver circuits, power electronic switches, minimum standing voltage on switches etc. In this work, DC source is realized using Photo Voltaic (PV) systems. The most well-known Perturb and Observe (P&O) algorithm is used for PV systems to achieve Maximum Power Point (MPP). The efficacy of aforementioned method is verified through Total Harmonic Distortion by taking R and RL loads. The simulation has been accomplished in MATLAB.
- 1 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 1-7
Generalized cascaded Multi Level Inverter using reduced number of components with PV systems
A Multi Level Inverter (MLI) has numerous industrial applications over a conventional two-level inverter due to its attractive features like it produces staircase output waveform with very lower distortion, it has less dv/dt stresses on switches, it operates effectively in both symmetric and asymmetric states, it performs at lower switching frequency and hence lower switching loss, etc. But, unfortunately, it needs greater number of power semiconductor switches and associated gate drive circuits. So, it may cause the overall system to be more complex and expensive. This paper presents a new topology of MLI with reduced number of semi conductor switches typically called as generalized cascaded MLI (with constant DC voltage sources). It can be analysed in both symmetric and asymmetric states by considering different criteria for optimal structures such as minimum number of DC sources, gate driver circuits, power electronic switches, minimum standing voltage on switches etc. In this work, DC source is realized using Photo Voltaic (PV) systems. The most well-known Perturb and Observe (P&O) algorithm is used for PV systems to achieve Maximum Power Point (MPP). The efficacy of aforementioned method is verified through Total Harmonic Distortion by taking R and RL loads. The simulation has been accomplished in MATLAB.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 761-765
Performance evaluation of 50KWp rooftop solar PV plant
Performance evaluation is most important aspect to asses the real time behavior of grid-connected solar PV systems. This paper attempts to evaluate the performance of 50KWp Grid-tied Solar PV system located at Shri Vishnu Educational Society, Bhimavaram, India. Performance parameters based on IEC standard-61724 which includes Final Yield (YF), Reference Yield (YR), Performance Ratio (PR) and Capacity Factors (CF) are evaluated on hourly, daily and monthly bases. Actual energy output to the Point of Common Coupling (PCC) is calculated based on system analysis. Additionally the performance evaluation gives a insight on identifying real time operational issues and allows comparison between different existing plants located at various geographically locations. Results substantially validates the actual performance of the solar PV system in real time conditions.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 761-765
Performance evaluation of 50KWp rooftop solar PV plant
Performance evaluation is most important aspect to asses the real time behavior of grid-connected solar PV systems. This paper attempts to evaluate the performance of 50KWp Grid-tied Solar PV system located at Shri Vishnu Educational Society, Bhimavaram, India. Performance parameters based on IEC standard-61724 which includes Final Yield (YF), Reference Yield (YR), Performance Ratio (PR) and Capacity Factors (CF) are evaluated on hourly, daily and monthly bases. Actual energy output to the Point of Common Coupling (PCC) is calculated based on system analysis. Additionally the performance evaluation gives a insight on identifying real time operational issues and allows comparison between different existing plants located at various geographically locations. Results substantially validates the actual performance of the solar PV system in real time conditions.
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Loop slope adjustment methods for the control of Automatic Voltage Regulator
This paper explores well known PID tuning algorithms based on loop slope adjustment and its application to the control of Automatic Voltage Regulator for both set point tracking and disturbance rejections. Four different PID tuning algorithm viz. Zeigler Nichols Method, Modified Ziegler-Nichols, Bode's Integral based method and Flat phase method were considered. Each of these methods gives a new approach to relate Ti and Td apart from achieving desired specifications. Performance comparison was carried out considering some well known performance criteria.
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Loop slope adjustment methods for the control of Automatic Voltage Regulator
This paper explores well known PID tuning algorithms based on loop slope adjustment and its application to the control of Automatic Voltage Regulator for both set point tracking and disturbance rejections. Four different PID tuning algorithm viz. Zeigler Nichols Method, Modified Ziegler-Nichols, Bode's Integral based method and Flat phase method were considered. Each of these methods gives a new approach to relate Ti and Td apart from achieving desired specifications. Performance comparison was carried out considering some well known performance criteria.