Huichao Chai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Huichao Chai has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Wenhui Wang
Tsinghua University
9 shared publications Yongxiang Feng
State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, China
4 shared publicationsFei Liang
State Key Laboratory of Precision Measurement Technology and Instrument Department of Precision Instrument Tsinghua University Beijing 100084 P. R. China
3 shared publicationsJunwen Zhu
State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, China
3 shared publications- Junwen Zhu
State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing 100084, P. R. China
3 shared publications - Liang Huang
Hefei University of Technology
3 shared publications
Latest Publications
- 3 October 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (43) , 8810-8817
DLD-based on-chip sample handling for label-free single-cell MS cytometry
Single-cell mass spectrometry (MS) plays a pivotal role in biochemical analysis. Its combination with microfluidics has given rise to label-free mass cytometry. Efficient on-chip handling of cell samples is crucial for successful MS cytometry but has been rare. Herein, we propose a passive means for cell sample handling (i.e., sorting and desalting) using deterministic lateral displacement (DLD), merely by designing hydrodynamic micro-structures. Specifically, two DLD arrays are configured in sequence to focus target cells by size, and then sort target cells and replace their solution with MS extraction solution. In the sample outlet, an electrospray ionization capillary is integrated with an on-chip liquid metal alloy electrode as the ionization source to allow consecutive MS cytometry analysis. With this handy setting, we can achieve sample-in-result-out, i.e., inject cell solution and collect MS data for target cells. As demonstration, the integrated microfluidic chip was used to handle and analyze three types of cells respectively, collecting satisfactory MS cytometry analysis data to discriminate cell types. We envision that the proposed method sets up a new paradigm in efficient sample handling for single-cell MS analysis, as either a stand-alone module or integrated part of on-chip MS cytometry.
- 3 October 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (43) , 8810-8817
DLD-based on-chip sample handling for label-free single-cell MS cytometry
Single-cell mass spectrometry (MS) plays a pivotal role in biochemical analysis. Its combination with microfluidics has given rise to label-free mass cytometry. Efficient on-chip handling of cell samples is crucial for successful MS cytometry but has been rare. Herein, we propose a passive means for cell sample handling (i.e., sorting and desalting) using deterministic lateral displacement (DLD), merely by designing hydrodynamic micro-structures. Specifically, two DLD arrays are configured in sequence to focus target cells by size, and then sort target cells and replace their solution with MS extraction solution. In the sample outlet, an electrospray ionization capillary is integrated with an on-chip liquid metal alloy electrode as the ionization source to allow consecutive MS cytometry analysis. With this handy setting, we can achieve sample-in-result-out, i.e., inject cell solution and collect MS data for target cells. As demonstration, the integrated microfluidic chip was used to handle and analyze three types of cells respectively, collecting satisfactory MS cytometry analysis data to discriminate cell types. We envision that the proposed method sets up a new paradigm in efficient sample handling for single-cell MS analysis, as either a stand-alone module or integrated part of on-chip MS cytometry.
- Top Cited PapersOpen Access
- 30 December 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-16
Neuromorphic-enabled video-activated cell sorting
Imaging flow cytometry allows image-activated cell sorting (IACS) with enhanced feature dimensions in cellular morphology, structure, and composition. However, existing IACS frameworks suffer from the challenges of 3D information loss and processing latency dilemma in real-time sorting operation. Herein, we establish a neuromorphic-enabled video-activated cell sorter (NEVACS) framework, designed to achieve high-dimensional spatiotemporal characterization content alongside high-throughput sorting of particles in wide field of view. NEVACS adopts event camera, CPU, spiking neural networks deployed on a neuromorphic chip, and achieves sorting throughput of 1000 cells/s with relatively economic hybrid hardware solution (~$10 K for control) and simple-to-make-and-use microfluidic infrastructures. Particularly, the application of NEVACS in classifying regular red blood cells and blood-disease-relevant spherocytes highlights the accuracy of using video over a single frame (i.e., average error of 0.99% vs 19.93%), indicating NEVACS’ potential in cell morphology screening and disease diagnosis.
- 30 December 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-16
Top Cited PapersOpen AccessNeuromorphic-enabled video-activated cell sorting
Imaging flow cytometry allows image-activated cell sorting (IACS) with enhanced feature dimensions in cellular morphology, structure, and composition. However, existing IACS frameworks suffer from the challenges of 3D information loss and processing latency dilemma in real-time sorting operation. Herein, we establish a neuromorphic-enabled video-activated cell sorter (NEVACS) framework, designed to achieve high-dimensional spatiotemporal characterization content alongside high-throughput sorting of particles in wide field of view. NEVACS adopts event camera, CPU, spiking neural networks deployed on a neuromorphic chip, and achieves sorting throughput of 1000 cells/s with relatively economic hybrid hardware solution (~$10 K for control) and simple-to-make-and-use microfluidic infrastructures. Particularly, the application of NEVACS in classifying regular red blood cells and blood-disease-relevant spherocytes highlights the accuracy of using video over a single frame (i.e., average error of 0.99% vs 19.93%), indicating NEVACS’ potential in cell morphology screening and disease diagnosis.
- 12 December 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (3) , 308-318
Liquid metal electrodes enabled cascaded on-chip dielectrophoretic separation of large-size-range particles
We cascade accumulative dielectrophoretic deflection effects with passive flow fraction mechanisms for high-efficiency separation of a large range of particles, using alternative side-wall liquid metal electrode segments and bypass outlets.
- 12 December 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (3) , 308-318
Liquid metal electrodes enabled cascaded on-chip dielectrophoretic separation of large-size-range particles
We cascade accumulative dielectrophoretic deflection effects with passive flow fraction mechanisms for high-efficiency separation of a large range of particles, using alternative side-wall liquid metal electrode segments and bypass outlets.
- 28 January 2024
- Published by Wiley in Advanced Materials
- Vol. 36 (21) , e2310212
Capillarity Enabled Large‐Array Liquid Metal Electrodes for Compact and High‐Throughput Dielectrophoretic Microfluidics
Dielectrophoresis (DEP) particle separation has label‐free, well‐controllable, and low‐damage merits. Sidewall microelectrodes made of liquid metal alloy (LMA) inherits the additional advantage of thick electrodes to generate impactful DEP force. However, existing LMA electrode‐based devices lack the ability to integrate large‐array electrodes in a compact footprint, severely limiting flow rate and thus throughput. Herein, a facile and versatile method is proposed to integrate high‐density thick LMA electrodes in microfluidic devices, taking advantage of the passive control ability of capillary burst valves (CBVs). CBVs with carefully designed burst pressures are co‐designed in microfluidic channels, allowing self‐assembly of LMA electrode array through simple hand‐push injection. The arrayed electrode configuration brings the accumulative DEP deflection effect. Specifically, The fabricated 5000 pairs of sidewall electrodes in a compact chip are demonstrted to achieve ten times higher throughput in DEP deflection. The 5000‐electrode‐pair device is applied to successfully separate four mixed samples, including human peripheral blood mononuclear cells and A549 cells with the flow rate of 70 µL min−1. It is envisioned that this work can greatly facilitate LMA electrode array fabrication and offer a robust and versatile platform for DEP separation applications.
- 28 January 2024
- Published by Wiley in Advanced Materials
- Vol. 36 (21) , e2310212
Capillarity Enabled Large‐Array Liquid Metal Electrodes for Compact and High‐Throughput Dielectrophoretic Microfluidics
Dielectrophoresis (DEP) particle separation has label‐free, well‐controllable, and low‐damage merits. Sidewall microelectrodes made of liquid metal alloy (LMA) inherits the additional advantage of thick electrodes to generate impactful DEP force. However, existing LMA electrode‐based devices lack the ability to integrate large‐array electrodes in a compact footprint, severely limiting flow rate and thus throughput. Herein, a facile and versatile method is proposed to integrate high‐density thick LMA electrodes in microfluidic devices, taking advantage of the passive control ability of capillary burst valves (CBVs). CBVs with carefully designed burst pressures are co‐designed in microfluidic channels, allowing self‐assembly of LMA electrode array through simple hand‐push injection. The arrayed electrode configuration brings the accumulative DEP deflection effect. Specifically, The fabricated 5000 pairs of sidewall electrodes in a compact chip are demonstrted to achieve ten times higher throughput in DEP deflection. The 5000‐electrode‐pair device is applied to successfully separate four mixed samples, including human peripheral blood mononuclear cells and A549 cells with the flow rate of 70 µL min−1. It is envisioned that this work can greatly facilitate LMA electrode array fabrication and offer a robust and versatile platform for DEP separation applications.
- Top Cited PapersOpen Access
- 5 January 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (1) , eadl0501
Single-shot deterministic complex amplitude imaging with a single-layer metalens
Conventional imaging systems can only capture light intensity. Meanwhile, the lost phase information may be critical for a variety of applications such as label-free microscopy and optical metrology. Existing phase retrieval techniques typically require a bulky setup, multiframe measurements, or prior information of the target scene. Here, we proposed an extremely compact system for complex amplitude imaging, leveraging the extreme versatility of a single-layer metalens to generate spatially multiplexed and polarization phase–shifted point spread functions. Combining the metalens with a polarization camera, the system can simultaneously record four polarization shearing interference patterns along both in-plane directions, thus allowing the deterministic reconstruction of the complex amplitude light field in a single shot. Using an incoherent light-emitting diode as the illumination, we experimentally demonstrated speckle-noise–free complex amplitude imaging for both static and moving objects with tailored magnification ratio and field of view. The miniaturized and robust system may open the door for complex amplitude imaging in portable devices for point-of-care applications.
- 5 January 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (1) , eadl0501
Top Cited PapersOpen AccessSingle-shot deterministic complex amplitude imaging with a single-layer metalens
Conventional imaging systems can only capture light intensity. Meanwhile, the lost phase information may be critical for a variety of applications such as label-free microscopy and optical metrology. Existing phase retrieval techniques typically require a bulky setup, multiframe measurements, or prior information of the target scene. Here, we proposed an extremely compact system for complex amplitude imaging, leveraging the extreme versatility of a single-layer metalens to generate spatially multiplexed and polarization phase–shifted point spread functions. Combining the metalens with a polarization camera, the system can simultaneously record four polarization shearing interference patterns along both in-plane directions, thus allowing the deterministic reconstruction of the complex amplitude light field in a single shot. Using an incoherent light-emitting diode as the illumination, we experimentally demonstrated speckle-noise–free complex amplitude imaging for both static and moving objects with tailored magnification ratio and field of view. The miniaturized and robust system may open the door for complex amplitude imaging in portable devices for point-of-care applications.
- 22 June 2023
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 8 (7) , 2681-2690
Evaluating the Accuracy of Impedance Flow Cytometry with Cell-Sized Liposomes
Electrical properties of single cells are important label-free biomarkers of disease and immunity. At present, impedance flow cytometry (IFC) provides important means for high throughput characterization of single-cell electrical properties. However, the accuracy of the spherical single-shell electrical model widely used in IFC has not been well evaluated due to the lack of reliable and reproducible single-shell model particles with true-value electrical parameters as benchmarks. Herein, a method is proposed to evaluate the accuracy of the single-cell electrical model with cell-sized unilamellar liposomes synthesized through double emulsion droplet microfluidics. The influence of three key dimension parameters (i.e., the measurement channel width w, height h, and electrode gap g) in the single-cell electrical model were evaluated through experiment. It was found that the relative error of the electrical intrinsic parameters measured by IFC is less than 10% when the size of the sensing zone is close to the measured particles. It further reveals that h has the greatest influence on the measurement accuracy, and the maximum relative error can reach ∼30%. Error caused by g is slightly larger than w. This provides a solid guideline for the design of IFC measurement system. It is envisioned that this method can advance further improvement of IFC and accurate electrical characterization of single cells.
- 22 June 2023
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 8 (7) , 2681-2690
Evaluating the Accuracy of Impedance Flow Cytometry with Cell-Sized Liposomes
Electrical properties of single cells are important label-free biomarkers of disease and immunity. At present, impedance flow cytometry (IFC) provides important means for high throughput characterization of single-cell electrical properties. However, the accuracy of the spherical single-shell electrical model widely used in IFC has not been well evaluated due to the lack of reliable and reproducible single-shell model particles with true-value electrical parameters as benchmarks. Herein, a method is proposed to evaluate the accuracy of the single-cell electrical model with cell-sized unilamellar liposomes synthesized through double emulsion droplet microfluidics. The influence of three key dimension parameters (i.e., the measurement channel width w, height h, and electrode gap g) in the single-cell electrical model were evaluated through experiment. It was found that the relative error of the electrical intrinsic parameters measured by IFC is less than 10% when the size of the sensing zone is close to the measured particles. It further reveals that h has the greatest influence on the measurement accuracy, and the maximum relative error can reach ∼30%. Error caused by g is slightly larger than w. This provides a solid guideline for the design of IFC measurement system. It is envisioned that this method can advance further improvement of IFC and accurate electrical characterization of single cells.
- 15 April 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (11) , 2531-2539
Performance-enhanced clogging-free viscous sheath constriction impedance flow cytometry
Viscous SC IFC with clogging-free, accurate, and sensitive performance.
- 15 April 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (11) , 2531-2539
Performance-enhanced clogging-free viscous sheath constriction impedance flow cytometry
Viscous SC IFC with clogging-free, accurate, and sensitive performance.
- 22 November 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (2) , 240-249
Neural network-enhanced real-time impedance flow cytometry for single-cell intrinsic characterization
Single-cell impedance flow cytometry (IFC) is emerging as a label-free and non-invasive method for characterizing the electrical properties and revealing sample heterogeneity. At present, most IFC studies utilize phenomenological parameters (e.g., impedance amplitude, phase and opacity) to characterize single cells instead of intrinsic biophysical metrics (e.g., radius r, cytoplasm conductivity σi and specific membrane capacitance Csm). Intrinsic parameters are normally calculated off-line by time-consuming model-fitting methods. Here, we propose to employ neural network (NN)-enhanced IFC to achieve both real-time single-cell intrinsic characterization and intrinsic parameter-based cell classification at high throughput. Three intrinsic parameters (r, σi and Csm) can be obtained online and in real-time via a trained NN at 0.3 ms per single-cell event, achieving significant improvement in calculation speed. Experiments involving four cancer cells and one lymphocyte cell demonstrated 91.5% classification accuracy in the cell type for a test group of 9751 cell samples. By performing a viability assay, we provide evidence that the IFC test per se would not substantially affect the cell property. We envision that the NN-enhanced real-time IFC will provide a new platform for high-throughput, real-time and online cell intrinsic electrical characterization.
- 22 November 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (2) , 240-249
Neural network-enhanced real-time impedance flow cytometry for single-cell intrinsic characterization
Single-cell impedance flow cytometry (IFC) is emerging as a label-free and non-invasive method for characterizing the electrical properties and revealing sample heterogeneity. At present, most IFC studies utilize phenomenological parameters (e.g., impedance amplitude, phase and opacity) to characterize single cells instead of intrinsic biophysical metrics (e.g., radius r, cytoplasm conductivity σi and specific membrane capacitance Csm). Intrinsic parameters are normally calculated off-line by time-consuming model-fitting methods. Here, we propose to employ neural network (NN)-enhanced IFC to achieve both real-time single-cell intrinsic characterization and intrinsic parameter-based cell classification at high throughput. Three intrinsic parameters (r, σi and Csm) can be obtained online and in real-time via a trained NN at 0.3 ms per single-cell event, achieving significant improvement in calculation speed. Experiments involving four cancer cells and one lymphocyte cell demonstrated 91.5% classification accuracy in the cell type for a test group of 9751 cell samples. By performing a viability assay, we provide evidence that the IFC test per se would not substantially affect the cell property. We envision that the NN-enhanced real-time IFC will provide a new platform for high-throughput, real-time and online cell intrinsic electrical characterization.
- 21 May 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (13) , 2486-2494
A microfluidic device enabling deterministic single cell trapping and release
A passive strategy for deterministic single-cell trapping and release.
- 21 May 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (13) , 2486-2494
A microfluidic device enabling deterministic single cell trapping and release
A passive strategy for deterministic single-cell trapping and release.