Heine Nygard Riise
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Heine Nygard Riise has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Magnus Moe Nygård
Institute for Energy Technology, Kjeller, Norway
5 shared publications Erik Stensrud Marstein
3 shared publications- Erling Ween Eriksen
Institute for Energy Technology, Kjeller, Norway
3 shared publications - Mari B. Ogaard
Department of Solar Power Systems, Institute for Energy Technology
3 shared publications B. G. Svensson
Department of Physics/Center for Materials Science and Nanotechnology, University of Oslo , P.O. Box 1048, Blindern, N-0316 Oslo, Norway
2 shared publicationsMarie Syre Wiig
2 shared publications
Latest Publications
- Open Access
- 10 March 2026
- Published by Elsevier in Solar Energy
- Vol. 310
Nowcasting based on spatio-temporal string-level power measurements in utility-scale photovoltaic power plants
- 10 March 2026
- Published by Elsevier in Solar Energy
- Vol. 310
Open AccessNowcasting based on spatio-temporal string-level power measurements in utility-scale photovoltaic power plants
- Open Access
- 16 February 2026
- Published by EDP Sciences in EPJ Photovoltaics
- Vol. 17, 9
Analyzing and modeling snow loss and snow loss accumulation in ground-mounted photovoltaic systems
Snow can cause significant energy loss in photovoltaic systems, making it essential to account for in performance modeling for all snow-prone regions. Previous snow loss research has been conducted primarily for roof mounted systems, and there is a lack of reported snow losses and validation of snow loss models for ground mounted systems. The aim of this work is to quantify snow loss and validate the Marion snow loss model for ground mounted PV systems using data from two scientific test sites in Norway. The quantification of snow losses indicates that ground mounted systems have lower snow losses compared to what have previously been documented for roof mounted systems in Norway and similar climates. Additionally, monofacial and bifacial arrays experienced similar losses. At the same test site, the bifacial array’s monthly losses were, on average, 0.2 percentage points higher than those of the monofacial array. In the snow loss model validation, the impact of snow data quality was evaluated. The global weather snow data sources assessed (ERA5-Land and ERA5 global) had a large share of snowfall events not giving snow accumulation. These events were linked to both small snowfalls and higher temperatures. The default pvlib implementation of the Marion model typically underestimates losses, but the error in relative yearly losses is less than 0.5 percentage points. The error in the modeling is mainly related to periods where the temperature is close to zero, when both the snow input data and the prediction of snow shedding are more uncertain. Ground interference due to large snow depths also leads to slower shedding and underestimation of losses in the model.
- 16 February 2026
- Published by EDP Sciences in EPJ Photovoltaics
- Vol. 17, 9
Open AccessAnalyzing and modeling snow loss and snow loss accumulation in ground-mounted photovoltaic systems
Snow can cause significant energy loss in photovoltaic systems, making it essential to account for in performance modeling for all snow-prone regions. Previous snow loss research has been conducted primarily for roof mounted systems, and there is a lack of reported snow losses and validation of snow loss models for ground mounted systems. The aim of this work is to quantify snow loss and validate the Marion snow loss model for ground mounted PV systems using data from two scientific test sites in Norway. The quantification of snow losses indicates that ground mounted systems have lower snow losses compared to what have previously been documented for roof mounted systems in Norway and similar climates. Additionally, monofacial and bifacial arrays experienced similar losses. At the same test site, the bifacial array’s monthly losses were, on average, 0.2 percentage points higher than those of the monofacial array. In the snow loss model validation, the impact of snow data quality was evaluated. The global weather snow data sources assessed (ERA5-Land and ERA5 global) had a large share of snowfall events not giving snow accumulation. These events were linked to both small snowfalls and higher temperatures. The default pvlib implementation of the Marion model typically underestimates losses, but the error in relative yearly losses is less than 0.5 percentage points. The error in the modeling is mainly related to periods where the temperature is close to zero, when both the snow input data and the prediction of snow shedding are more uncertain. Ground interference due to large snow depths also leads to slower shedding and underestimation of losses in the model.
- Open Access
- 6 May 2025
- Published by Elsevier in Solar Energy
- Vol. 296
Benchmarking irradiation models for photovoltaic applications: A comparative analysis of radiance-based tools
- 6 May 2025
- Published by Elsevier in Solar Energy
- Vol. 296
Open AccessBenchmarking irradiation models for photovoltaic applications: A comparative analysis of radiance-based tools
- Open Access
- 31 March 2025
- Published by Elsevier in Solar Energy
- Vol. 292
Elucidating uncertainty in bifacial photovoltaic gain estimation
- 31 March 2025
- Published by Elsevier in Solar Energy
- Vol. 292
Open AccessElucidating uncertainty in bifacial photovoltaic gain estimation
- Open Access
- 4 December 2024
- Published by Elsevier in Renewable Energy
- Vol. 239
Photovoltaic soiling loss in Europe: Geographical distribution and cleaning recommendations
- 4 December 2024
- Published by Elsevier in Renewable Energy
- Vol. 239
Open AccessPhotovoltaic soiling loss in Europe: Geographical distribution and cleaning recommendations
- 29 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 13 (6) , 920-928
Influence of Temperature Coefficient and Sensor Choice on PV System Performance
Owing to the well-known temperature dependence of photovoltaic (PV) module performance, it is important to correct the performance ratio with respect to temperature. In this study, temperature coefficients given by the manufacturer for three different PV cell technologies are compared with experimentally obtained temperature coefficients for a PV park situated in southern Norway. Three irradiance estimation methods are used to calculate these experimental temperature coefficients. The results show that they can differ significantly from the ones provided in the datasheet of the manufacturer for all three PV systems, but whether the temperature coefficient value increases or decreases depends on the systems and/or the irradiance estimation method. Furthermore, by analyzing nine clear sky days at different times of the year, it is found that the seasonality of the performance ratio can be significantly reduced when employing the experimental temperature coefficient rather than the datasheet temperature coefficient. As such, it may be more relevant to correct the performance ratio with experimental temperature coefficients rather than with the temperature coefficient from the system datasheet, especially for systems that experience large temperature differences. It is also found that the irradiance estimation method can significantly impact the experimental temperature coefficient. This study shows that the choice of irradiance estimation method and temperature coefficient can affect the performance interpretation of solar PV systems and must then be considered carefully.
- 29 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 13 (6) , 920-928
Influence of Temperature Coefficient and Sensor Choice on PV System Performance
Owing to the well-known temperature dependence of photovoltaic (PV) module performance, it is important to correct the performance ratio with respect to temperature. In this study, temperature coefficients given by the manufacturer for three different PV cell technologies are compared with experimentally obtained temperature coefficients for a PV park situated in southern Norway. Three irradiance estimation methods are used to calculate these experimental temperature coefficients. The results show that they can differ significantly from the ones provided in the datasheet of the manufacturer for all three PV systems, but whether the temperature coefficient value increases or decreases depends on the systems and/or the irradiance estimation method. Furthermore, by analyzing nine clear sky days at different times of the year, it is found that the seasonality of the performance ratio can be significantly reduced when employing the experimental temperature coefficient rather than the datasheet temperature coefficient. As such, it may be more relevant to correct the performance ratio with experimental temperature coefficients rather than with the temperature coefficient from the system datasheet, especially for systems that experience large temperature differences. It is also found that the irradiance estimation method can significantly impact the experimental temperature coefficient. This study shows that the choice of irradiance estimation method and temperature coefficient can affect the performance interpretation of solar PV systems and must then be considered carefully.
- Open Access
- 28 March 2023
- Published by Elsevier in Solar Energy
- Vol. 255, 208-221
The value of forecasts for PV power plants operating in the past, present and future Scandinavian energy markets
- 28 March 2023
- Published by Elsevier in Solar Energy
- Vol. 255, 208-221
Open AccessThe value of forecasts for PV power plants operating in the past, present and future Scandinavian energy markets
- 29 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 12 (4) , 1005-1013
Snow Loss Modeling for Roof Mounted Photovoltaic Systems: Improving the Marion Snow Loss Model
Accurate photovoltaics (PV) energy yield assessments for cold climates necessitate understanding and estimation of snow loss. Estimation of snow loss for a specific system requires a snow loss model. Multiple models to estimate snow loss are suggested in the literature, but extensive validation is lacking. In this work, we describe the effect of snow on PV systems by analyzing signatures in monitoring data and we evaluate the accuracy of a modified adaption of the Marion snow loss model. Eight different systems with a total installed capacity of 1.6 MW p , installed on both tilted and flat roofs, are analyzed. In the modified model we use different snow clearing rate coefficients for thin and thick snow covers to model the natural snow clearing process. The snow depth dependent coefficients yield lower error in the total modeled snow loss and capture climatic variations between locations more accurately compared to the standard constant coefficient. For most of the systems the total absolute snow loss is modeled with an error of less than 11%, on average 23% points lower than with the default implementation of the Marion model. Some of the systems have larger modeling errors, which can be related to effects not taken into account in the model, such as the effect of building heat leakage and shading on snow clearing.
- 29 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 12 (4) , 1005-1013
Snow Loss Modeling for Roof Mounted Photovoltaic Systems: Improving the Marion Snow Loss Model
Accurate photovoltaics (PV) energy yield assessments for cold climates necessitate understanding and estimation of snow loss. Estimation of snow loss for a specific system requires a snow loss model. Multiple models to estimate snow loss are suggested in the literature, but extensive validation is lacking. In this work, we describe the effect of snow on PV systems by analyzing signatures in monitoring data and we evaluate the accuracy of a modified adaption of the Marion snow loss model. Eight different systems with a total installed capacity of 1.6 MW p , installed on both tilted and flat roofs, are analyzed. In the modified model we use different snow clearing rate coefficients for thin and thick snow covers to model the natural snow clearing process. The snow depth dependent coefficients yield lower error in the total modeled snow loss and capture climatic variations between locations more accurately compared to the standard constant coefficient. For most of the systems the total absolute snow loss is modeled with an error of less than 11%, on average 23% points lower than with the default implementation of the Marion model. Some of the systems have larger modeling errors, which can be related to effects not taken into account in the model, such as the effect of building heat leakage and shading on snow clearing.
- Open Access
- 1 July 2021
- Published by Elsevier in Solar Energy
- Vol. 223, 238-247
Identifying snow in photovoltaic monitoring data for improved snow loss modeling and snow detection
- 1 July 2021
- Published by Elsevier in Solar Energy
- Vol. 223, 238-247
Open AccessIdentifying snow in photovoltaic monitoring data for improved snow loss modeling and snow detection