Gyu-Hyeon Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gyu-Hyeon Lee has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Dongmoon Min
Sungkyunkwan University, Suwon, Republic of Korea
3 shared publications - Ilkwon Byun
Faculty of Information Science and Electrical Engineering, Kyushu University, Fukuoka, Japan
3 shared publications - Jangwoo Kim
Seoul National University, Seoul, Republic of Korea
3 shared publications - Seongmin Na
Seoul National University, Seoul, Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 14 September 2024
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Architecture and Code Optimization
- Vol. 21 (3) , 1-27
CoolDC: A Cost-Effective Immersion-Cooled Datacenter with Workload-Aware Temperature Scaling
For datacenter architects, it is the most important goal to minimize the datacenter’s total cost of ownership for the target performance (i.e., TCO/performance). As the major component of a datacenter is a server farm, the most effective way of reducing TCO/performance is to improve the server’s performance and power efficiency. To achieve the goal, we claim that it is highly promising to reduce each server’s temperature to its most cost-effective point (or temperature scaling). In this article, we propose CoolDC , a novel and immediately applicable low-temperature cooling method to minimize the datacenter’s TCO. The key idea is to find and apply the most cost-effective sub-freezing temperature to target servers and workloads. For that purpose, we first apply the immersion cooling method to the entire servers to maintain a stable low temperature with little extra cooling and maintenance costs. Second, we define the TCO-optimal temperature for datacenter operation (e.g., 248K~273K (-25℃~0℃)) by carefully estimating all the costs and benefits at low temperatures. Finally, we propose CoolDC, our immersion-cooling datacenter architecture to run every workload at its own TCO-optimal temperature. By incorporating our low-temperature workload-aware temperature scaling, CoolDC achieves 12.7% and 13.4% lower TCO/performance than the conventional air-cooled and immersion-cooled datacenters, respectively, without any modification to existing computers.
- 14 September 2024
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Architecture and Code Optimization
- Vol. 21 (3) , 1-27
Open AccessCoolDC: A Cost-Effective Immersion-Cooled Datacenter with Workload-Aware Temperature Scaling
For datacenter architects, it is the most important goal to minimize the datacenter’s total cost of ownership for the target performance (i.e., TCO/performance). As the major component of a datacenter is a server farm, the most effective way of reducing TCO/performance is to improve the server’s performance and power efficiency. To achieve the goal, we claim that it is highly promising to reduce each server’s temperature to its most cost-effective point (or temperature scaling). In this article, we propose CoolDC , a novel and immediately applicable low-temperature cooling method to minimize the datacenter’s TCO. The key idea is to find and apply the most cost-effective sub-freezing temperature to target servers and workloads. For that purpose, we first apply the immersion cooling method to the entire servers to maintain a stable low temperature with little extra cooling and maintenance costs. Second, we define the TCO-optimal temperature for datacenter operation (e.g., 248K~273K (-25℃~0℃)) by carefully estimating all the costs and benefits at low temperatures. Finally, we propose CoolDC, our immersion-cooling datacenter architecture to run every workload at its own TCO-optimal temperature. By incorporating our low-temperature workload-aware temperature scaling, CoolDC achieves 12.7% and 13.4% lower TCO/performance than the conventional air-cooled and immersion-cooled datacenters, respectively, without any modification to existing computers.
- 31 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Micro
- Vol. 41 (3) , 80-86
A Next-Generation Cryogenic Processor Architecture
Cryogenic computing can achieve high performance and power efficiency by dramatically reducing the device's leakage power and wire resistance at low temperatures. Recent advances in cryogenic computing focus on developing cryogenic optical cache and memory devices to overcome memory capacity, latency, and power walls. However, little research has been conducted to develop a cryogenic-optimal core architecture even with its high potentials in performance, power, and area efficiency. In this paper, we first develop CryoCore-Model (CC-Model), a cryogenic processor modeling framework which can accurately estimate the maximum clock frequency of processor models running at 77K. Next, driven by the modeling tool, we design CryoCore, a 77K-optimal core microarchitecture to maximize the core's performance and area efficiency while minimizing the cooling cost. The proposed cryogenic processor architecture in this article achieves the large performance improvement and power reduction, and thus contributes to the future of high-performance and power-efficient computer systems.
- 31 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Micro
- Vol. 41 (3) , 80-86
A Next-Generation Cryogenic Processor Architecture
Cryogenic computing can achieve high performance and power efficiency by dramatically reducing the device's leakage power and wire resistance at low temperatures. Recent advances in cryogenic computing focus on developing cryogenic optical cache and memory devices to overcome memory capacity, latency, and power walls. However, little research has been conducted to develop a cryogenic-optimal core architecture even with its high potentials in performance, power, and area efficiency. In this paper, we first develop CryoCore-Model (CC-Model), a cryogenic processor modeling framework which can accurately estimate the maximum clock frequency of processor models running at 77K. Next, driven by the modeling tool, we design CryoCore, a 77K-optimal core microarchitecture to maximize the core's performance and area efficiency while minimizing the cooling cost. The proposed cryogenic processor architecture in this article achieves the large performance improvement and power reduction, and thus contributes to the future of high-performance and power-efficient computer systems.
- 1 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 335-348
CryoCore: A Fast and Dense Processor Architecture for Cryogenic Computing
Cryogenic computing can achieve high performance and power efficiency by dramatically reducing the device’s leakage power and wire resistance at low temperatures. Recent advances towards cryogenic computing focus on developing cryogenic-optimal cache and memory devices to overcome memory capacity, latency, and power walls. However, little research has been conducted to develop a cryogenic-optimal core architecture despite its high potentials in performance, power, and area efficiency. Once a cryogenic-optimal core becomes available, it will also take full advantage of the cryogenic-optimal cache and memory devices, which leads to a cryogenic-optimal computer.In this paper, we first develop CryoCore-Model (CC-Modet), a cryogenic processor modeling framework which can accurately estimate the maximum clock frequency of processor models running at 77K. Next, driven by the modeling tool, we design CryoCore, a 77K-optimal core microarchitecture to maximize the core’s performance and area efficiency while minimizing the cooling cost. The key idea of CryoCore is to architect a core in a way to reduce the size and number of cooling-unfriendly microarchitecture units and maximize the potential of a voltage and frequency scaling at 77K. Finally, we propose two halfsized, but differently voltage-scaled CryoCore designs aiming for either the maximum performance or power efficiency. With both conventional and our design integrated with cryogenic memories, our high-performance CryoCore design achieves 41% higher single-thread performance for the same power budget and 2x higher multi-thread performance for the same die area. Our lowpower CryoCore design reduces the power cost by 38% without sacrificing the single-thread performance.
- 1 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 335-348
CryoCore: A Fast and Dense Processor Architecture for Cryogenic Computing
Cryogenic computing can achieve high performance and power efficiency by dramatically reducing the device’s leakage power and wire resistance at low temperatures. Recent advances towards cryogenic computing focus on developing cryogenic-optimal cache and memory devices to overcome memory capacity, latency, and power walls. However, little research has been conducted to develop a cryogenic-optimal core architecture despite its high potentials in performance, power, and area efficiency. Once a cryogenic-optimal core becomes available, it will also take full advantage of the cryogenic-optimal cache and memory devices, which leads to a cryogenic-optimal computer.In this paper, we first develop CryoCore-Model (CC-Modet), a cryogenic processor modeling framework which can accurately estimate the maximum clock frequency of processor models running at 77K. Next, driven by the modeling tool, we design CryoCore, a 77K-optimal core microarchitecture to maximize the core’s performance and area efficiency while minimizing the cooling cost. The key idea of CryoCore is to architect a core in a way to reduce the size and number of cooling-unfriendly microarchitecture units and maximize the potential of a voltage and frequency scaling at 77K. Finally, we propose two halfsized, but differently voltage-scaled CryoCore designs aiming for either the maximum performance or power efficiency. With both conventional and our design integrated with cryogenic memories, our high-performance CryoCore design achieves 41% higher single-thread performance for the same power budget and 2x higher multi-thread performance for the same die area. Our lowpower CryoCore design reduces the power cost by 38% without sacrificing the single-thread performance.