Arun M. Raghavan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Arun M. Raghavan has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Gavriel D. Kohlberg
Department of Otolaryngology-Head and Neck Surgery, University of Cincinnati/Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
2 shared publicationsJoseph T. Breen
Department of Otolaryngology-Head and Neck Surgery, University of Cincinnati/Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
2 shared publicationsNoga Lipschitz
Department of Otolaryngology-Head and Neck Surgery, University of Cincinnati/Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
2 shared publicationsRavi N. Samy
Department of Otolaryngology-Head and Neck Surgery, University of Cincinnati/Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
2 shared publicationsAlice Alexander
Department of Pathology, Johns Hopkins University, Baltimore, MD, USA
1 shared publicationAndrew Wilson
Department of Pathology, Johns Hopkins University, Baltimore, MD, USA
1 shared publication
Latest Publications
- Open Access
- 3 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 863-877
Wireless Hearables With Programmable Speech AI Accelerators
- 3 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 863-877
Open AccessWireless Hearables With Programmable Speech AI Accelerators
- 26 May 2020
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 163 (4) , 771-777
Visual Speech Recognition: Improving Speech Perception in Noise through Artificial Intelligence
Objectives: To compare speech perception (SP) in noise for normal‐hearing (NH) individuals and individuals with hearing loss (IWHL) and to demonstrate improvements in SP with use of a visual speech recognition program (VSRP).Study Design: Single‐institution prospective study.Setting: Tertiary referral center.Subjects and Methods: Eleven NH and 9 IWHL participants in a sound‐isolated booth facing a speaker through a window. In non‐VSRP conditions, SP was evaluated on 40 Bamford‐Kowal‐Bench speech‐in‐noise test (BKB‐SIN) sentences presented by the speaker at 50 A‐weighted decibels (dBA) with multiperson babble noise presented from 50 to 75 dBA. SP was defined as the percentage of words correctly identified. In VSRP conditions, an infrared camera was used to track 35 points around the speaker’s lips during speech in real time. Lip movement data were translated into speech‐text via an in‐house developed neural network–based VSRP. SP was evaluated similarly in the non‐VSRP condition on 42 BKB‐SIN sentences, with the addition of the VSRP output presented on a screen to the listener.Results: In high‐noise conditions (70‐75 dBA) without VSRP, NH listeners achieved significantly higher speech perception than IWHL listeners (38.7% vs 25.0%, P =. 02). NH listeners were significantly more accurate with VSRP than without VSRP (75.5% vs 38.7%, P <. 0001), as were IWHL listeners (70.4% vs 25.0% P <. 0001). With VSRP, no significant difference in SP was observed between NH and IWHL listeners (75.5% vs 70.4%, P =. 15).Conclusions: The VSRP significantly increased speech perception in high‐noise conditions for NH and IWHL participants and eliminated the difference in SP accuracy between NH and IWHL listeners.
- 26 May 2020
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 163 (4) , 771-777
Visual Speech Recognition: Improving Speech Perception in Noise through Artificial Intelligence
Objectives: To compare speech perception (SP) in noise for normal‐hearing (NH) individuals and individuals with hearing loss (IWHL) and to demonstrate improvements in SP with use of a visual speech recognition program (VSRP).Study Design: Single‐institution prospective study.Setting: Tertiary referral center.Subjects and Methods: Eleven NH and 9 IWHL participants in a sound‐isolated booth facing a speaker through a window. In non‐VSRP conditions, SP was evaluated on 40 Bamford‐Kowal‐Bench speech‐in‐noise test (BKB‐SIN) sentences presented by the speaker at 50 A‐weighted decibels (dBA) with multiperson babble noise presented from 50 to 75 dBA. SP was defined as the percentage of words correctly identified. In VSRP conditions, an infrared camera was used to track 35 points around the speaker’s lips during speech in real time. Lip movement data were translated into speech‐text via an in‐house developed neural network–based VSRP. SP was evaluated similarly in the non‐VSRP condition on 42 BKB‐SIN sentences, with the addition of the VSRP output presented on a screen to the listener.Results: In high‐noise conditions (70‐75 dBA) without VSRP, NH listeners achieved significantly higher speech perception than IWHL listeners (38.7% vs 25.0%, P =. 02). NH listeners were significantly more accurate with VSRP than without VSRP (75.5% vs 38.7%, P <. 0001), as were IWHL listeners (70.4% vs 25.0% P <. 0001). With VSRP, no significant difference in SP was observed between NH and IWHL listeners (75.5% vs 70.4%, P =. 15).Conclusions: The VSRP significantly increased speech perception in high‐noise conditions for NH and IWHL participants and eliminated the difference in SP accuracy between NH and IWHL listeners.
- 1 February 2020
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 41 (2) , e268-e272
Is Longer Surgery More Dangerous? Operative Duration Not Associated With Complications After Vestibular Schwannoma Resection
Objective: To examine the association between operative duration and complications after vestibular schwannoma (VS) surgery. Study Design: Retrospective chart review. Setting: Tertiary referral center. Patients: One hundred forty-eight patients undergoing vestibular schwannoma resection in a single institution. Intervention: Vestibular schwannoma resection. Main Outcome Measures: Operative duration, surgical approach, tumor size, and postoperative complications. Results: Forty-one patients underwent middle cranial fossa (MCF) approach, 46 underwent translabyrinthine (TL) approach, and 61 underwent retrosigmoid (RS) approach. The mean operative duration overall was 407 minutes (MCF—339 min, TL—450 min, RS 420 min). When controlling for tumor size, there was no difference in procedure duration by approach (OR 0.92, CI 0.82–1.02, p=0.11). When controlling for approach, there was a significant increase in procedure duration by tumor size (OR 1.36, CI 1.23–1.50, p < 0.0001). Increased procedure duration was not associated with 30-day readmission (p = 0.82), cerebrospinal fluid leak (CSF) (p = 0.84), return to the operating room (p = 0.75), postoperative deep vein thrombosis (p = 1.0), postoperative stroke (p = 0.23), or postoperative wound complications (p = 0.70). Longer operative time was associated with increased hospital length of stay (p = 0.04). However, when controlling for tumor size and surgical approach, hospital length of stay was no longer associated with increased procedure duration (OR 1.15, CI 0.98–1.33, p = 0.3). Conclusion: Increased operative duration was associated with larger tumor size; however contrary to previous reports, increased operative duration was not associated with postoperative complications.
- 1 February 2020
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 41 (2) , e268-e272
Is Longer Surgery More Dangerous? Operative Duration Not Associated With Complications After Vestibular Schwannoma Resection
Objective: To examine the association between operative duration and complications after vestibular schwannoma (VS) surgery. Study Design: Retrospective chart review. Setting: Tertiary referral center. Patients: One hundred forty-eight patients undergoing vestibular schwannoma resection in a single institution. Intervention: Vestibular schwannoma resection. Main Outcome Measures: Operative duration, surgical approach, tumor size, and postoperative complications. Results: Forty-one patients underwent middle cranial fossa (MCF) approach, 46 underwent translabyrinthine (TL) approach, and 61 underwent retrosigmoid (RS) approach. The mean operative duration overall was 407 minutes (MCF—339 min, TL—450 min, RS 420 min). When controlling for tumor size, there was no difference in procedure duration by approach (OR 0.92, CI 0.82–1.02, p=0.11). When controlling for approach, there was a significant increase in procedure duration by tumor size (OR 1.36, CI 1.23–1.50, p < 0.0001). Increased procedure duration was not associated with 30-day readmission (p = 0.82), cerebrospinal fluid leak (CSF) (p = 0.84), return to the operating room (p = 0.75), postoperative deep vein thrombosis (p = 1.0), postoperative stroke (p = 0.23), or postoperative wound complications (p = 0.70). Longer operative time was associated with increased hospital length of stay (p = 0.04). However, when controlling for tumor size and surgical approach, hospital length of stay was no longer associated with increased procedure duration (OR 1.15, CI 0.98–1.33, p = 0.3). Conclusion: Increased operative duration was associated with larger tumor size; however contrary to previous reports, increased operative duration was not associated with postoperative complications.
- 1 September 2018
- Published by Elsevier in Epilepsy Research
- Vol. 145, 27-30
Open-source system for millisecond-synchronized continuous video-EEG
- 1 September 2018
- Published by Elsevier in Epilepsy Research
- Vol. 145, 27-30
Open-source system for millisecond-synchronized continuous video-EEG