MCManish Chauhan

Manish Chauhan

*This is an algorithmically generated author record based on publicly available information.

Manish Chauhan has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Hybrid Continuum Robot Designs and Architectures for Healthcare Applications

    by Burak Ozdemir, Muhammad A. Khalid, Manish Chauhan, Pietro Valdastri, James H. Chandler

    Continuum robots offer enhanced flexibility and dexterity compared to traditional rigid‐link systems, making them well‐suited to minimally invasive and endoluminal interventions. Numerous design and actuation configurations have been proposed, spanning from hard yet flexible robotic structures to passively adaptable monolithic soft‐bodied designs. However, unimodal approaches often face trade‐offs between compliance, range of motion, and control precision. Recently, hybrid continuum robots that integrate multiple design and/or actuation strategies within a single architecture have emerged. By spanning a broader range of materials and actuation approaches, hybrid continuum robots aim to overcome the limitations of single‐modal systems and present new capabilities suited to challenging clinical applications. The presented review specifically focuses on the designs, architectures, and configurations of this emerging field, emphasizing how distinct structural and actuation combinations present significant diversity in performance and application. We first stratify hybrid continuum robot architectures by their material composition, capturing hard‐ and soft‐bodied designs in exclusive or combined configurations. Within each high‐level grouping, we consider the range of associated actuation methods and clinical applications presented to date. Adjacent approaches that achieve hybrid performance through active adaptability are also considered. Finally, we discuss the open challenges and opportunities for continuum robot hybridization in the context of clinical applications and future translation.


  • Data-Driven Methods for Deploying AI

    by Manish Chauhan

    This seminar explores statistical and data-driven methods for making AI systems robust when they move from simulation into physical environments. It covers domain shift, sensor noise, Bayesian estimation, and uncertainty-aware deployment for researchers working at the interface of AI and engineering.

  • Open Access

    Design and optimisation of soft robotic actuators for augmented lung-ventilation

    by Christopher Michael Hofmair, Kunal Bhakhri, Manish Chauhan


  • Open Access

    Evaluation and usability study of low-cost laparoscopic box trainer “Lap-Pack”: a 2-stage multicenter cohort study

    by Manish Chauhan, Riya MBChB Sawhney, Carolina F. MBChB Da Silva, Noel Aruparayil, Jesudian Ms Gnanaraj, Sukumar Ms Maiti, Anurag Mishra, Aaron Mbchb Quyn, William MBChB Bolton, Joshua Mbchb Burke, et al.

    Introduction: Laparoscopic training is restricted in low resource settings due to limited access to specialist training equipment and financial constraints. This study aimed to evaluate simulation skills and usability of an original low-cost laparoscopic trainer, the “Lap-Pack,” developed at the University of Leeds, UK. Methods: Stage I evaluation was conducted in Kolkata (India) between March, 12 and 14, 2019. Laparoscopic simulation training was based on the 5 domains of fundamentals of laparoscopic surgery (FLS), which assessed skill acquisition across 7 rural surgeons from North-East India. The McGill Inanimate System for Training and Evaluation of Laparoscopic Skills (MISTELS) criteria was used to statistically analyze trainee performance between pretraining and posttraining sessions. Also, Lap-Pack was qualitatively compared with a commercial box trainer, Inovus Pyxus HD (IPHD). Stage II involved a multi-center usability study in 2 centers of India and the United Kingdom (2019). Seventy-eight participants performed 2 FLS tasks using Lap-Pack and provided scores on a 25-point questionnaire, including a preestablished Face-Validity Criteria and 4 evaluation categories—Usability, Camera, View, and, Material. Results: In stage I, the total posttraining MISTELS score for Lap-Pack was higher, that is 773.37 (SD: 183.67) than pretraining score, that is 351.2 (SD: 471.5). The posttraining scores showed laparoscopic skill acquisition with statistically significant (PPPPPP<0.05) features of Lap-Pack were appreciated. Conclusion: The Lap-Pack is a suitable low fidelity simulator for laparoscopic training in a low-resource setting.


  • Open Access

    An Origami-Based Soft Robotic Actuator for Upper Gastrointestinal Endoscopic Applications

    by Manish Chauhan, James H. Chandler, Animesh Jha, Venkataraman Subramaniam, Keith L. Obstein, Pietro Valdastri

    Soft pneumatic actuators have been explored for endoscopic applications, but challenges in fabricating complex geometry with desirable dimensions and compliance remain. The addition of an endoscopic camera or tool channel is generally not possible without significant change in the diameter of the actuator. Radial expansion and ballooning of actuator walls during bending is undesirable for endoscopic applications. The inclusion of strain limiting methods like, wound fibre, mesh, or multi-material molding have been explored, but the integration of these design approaches with endoscopic requirements drastically increases fabrication complexity, precluding reliable translation into functional endoscopes. For the first time in soft robotics, we present a multi-channel, single material elastomeric actuator with a fully corrugated design (inspired by origami); offering specific functionality for endoscopic applications. The features introduced in this design include i) fabrication of multi-channel monolithic structure of 8.5 mm diameter, ii) incorporation of the benefits of corrugated design in a single material (i.e., limited radial expansion and improved bending efficiency), iii) design scalability (length and diameter), and iv) incorporation of a central hollow channel for the inclusion of an endoscopic camera. Two variants of the actuator are fabricated which have different corrugated or origami length, i.e., 30 mm and 40 mm respectively). Each of the three actuator channels is evaluated under varying volumetric (0.5 mls-1 and 1.5 mls-1 feed rate) and pressurized control to achieve a similar bending profile with the maximum bending angle of 150°. With the intended use for single use upper gastrointestinal endoscopic application, it is desirable to have linear relationships between actuation and angular position in soft pneumatic actuators with high bending response at low pressures; this is where the origami actuator offers contribution. The soft pneumatic actuator has been demonstrated to achieve a maximum bending angle of 200° when integrated with manually driven endoscope. The simple 3-step fabrication technique produces a complex origami pattern in a soft robotic structure, which promotes low pressure bending through the opening of the corrugation while retaining a small diameter and a central lumen, required for successful endoscope integration.


  • Metabolite Identification of Helicobacter Pylori Supernatant Using Near-IR Raman Spectroscopy

    by Manish Chauhan, Anthony Buckley, Animesh Jha, Mark Wilcox, Venkatraman Subramaniam, Pietro Valdastri

    Helicobacter pylori, a non-invasive gram-negative bacteria is well known for its direct cause and effect relationship with peptic ulcer, gastric or duodenal ulceration. Its severe effect on human begin with its colonization and production of various enzyme like Vacuolating cytotoxin, Urease and Heat shock proteins. Urease is complex spherical protein which causes hydrolysis of gastric urea to ammonia and CO 2 . The enzymatic reaction results in increase of gastric pH and hence results in gastric cancer. We present a photonic based technique to identify these proteins in its natural supernatant condition. The Raman spectrum of Helicobacter pylori is reported and the vibrational peaks are identified with corresponding chemical bonds in the biochemical enzyme. This can lay the foundation for future diagnostic tool for clinical detection of peptic ulcer, gastric or duodenal ulceration.

  • Tu1964 USABILITY OF A NOVEL DISPOSABLE ENDOSCOPE FOR GASTRIC CANCER SCREENING IN LOW-RESOURCE SETTINGS: RESULTS FROM RURAL INDIA

    by James H. Chandler, Manish Chauhan, Simone Caló, Noel Aruparayil, Nicolo Garbin, Federico Campisano, Keith L. Obstein, Pietro Valdastri


  • PH characterization of urease using Raman Spectroscopy

    by Manish Chauhan, Animesh Jha, Venkatraman Subramanian, Pietro Valdastri

    Jack bean urease is a complex biochemical enzyme with the unique monomeric structure of polypeptides with an active site containing 2 nickel ions. Its pH-based characterization is spectroscopically investigated in an acidic (Hydrochloric acid) environment for understanding its limit of detection.


  • Design and Modeling of a Three-Degree-of-Freedom Articulating Robotic Microsurgical Forceps for Trans-Oral Laser Microsurgery

    by Manish Chauhan, Nikhil Deshpande, Darwin G. Caldwell, Leonardo S. Mattos

    Trans-oral laser microsurgery (TLM) is a surgical procedure for removing malignancies (e.g., cysts, polyps, tumors) of the laryngeal region through laser ablation. Intraoperative microsurgical forceps (i.e., microforceps) are used for tissue manipulation. The microforceps are rigid, single degree-of-freedom (DOF) devices (open–close) with precurved jaws to access different parts of the curved cylindrical laryngeal region. These microforceps are manually handled and are subject to hand tremors, poor reachability, and nonergonomic use, resulting in poor efficacy and efficiency in the surgery. A novel 3DOF motorized microforceps device is presented here, integrated with a 6DOF serial robotic manipulator. The device, referred to as RMF-3, offers three motorized DOFs: (i) open–close forceps jaw; (ii) tool rotation; and (iii) tool-tip articulation. It is designed to be compliant with TLM spatial constraints. The manual handling is replaced by tele-operation device, the omega.7. The design of the RMF-3 is characterized through theoretical and experimental analysis. The device shows a maximum articulation of 38 deg and tool rotation of 100 deg. Its performance is further evaluated through user trials using the ring-in-loop setup. The user trials demonstrate benefits of the 3DOF workspace of the device along with its teleoperation control. RMF-3 offers an improved workspace and reachability within the laryngeal region. Surgeons, in their preliminary evaluation of the device, appreciated the ability to articulate the tip, along with rotation, for hard-to-reach parts of the surgical site. RMF-3 offers an ergonomic robotic teleoperation control interface which overcomes hand tremors and extreme wrist excursion which leads to surgeon pain and discomfort.


  • Characterization of Urease enzyme using Raman and FTIR Spectroscopy

    by M. Chauhan, C. Maddi, A. Jha, V. Subramanian, P. Valdastri

    Urease is a commonly found enzyme in the natural biological environment like plants, soil, and animals. Its characteristic decomposition is spectroscopically investigated in acidic (chloride) environment for understanding nitrogen cycle.