Sepaldeep Singh Dhaliwal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sepaldeep Singh Dhaliwal has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Rochdi Merzouki
Centre de Recherche en Informatique, Signal et Automatique de Lille UMR CNRS 9189, University of Lille and Centrale Lille Institute, Lille, France
4 shared publicationsAbdelkader Belarouci
Centre de Recherche en Informatique, Signal et Automatique de Lille UMR CNRS 9189, University of Lille and Centrale Lille Institute, Lille, France
2 shared publications- Mario Sanz-Lopez
CNRS, Lille, France
2 shared publications - Sarah Wilby
Medical Physics Department, Portsmouth Hospitals NHS Trust, Portsmouth, U.K.
2 shared publications - Taha Chettibi
Structures Laboratory, Department of Mechanics, Saad Dahlab University, Blida, Algeria
2 shared publications Wojciech Polak
Medical Physics Department, Portsmouth Hospitals NHS Trust, Portsmouth, U.K.
2 shared publications
Latest Publications
- 23 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 4 (3) , 667-681
Cooperative Brachytherapy Robotic Concept for Localized Cancer Treatment Under Real-Time MRI
Currently, localized cancer treatment is one of the focused research interests of Physicians. Indeed, with the advent of sensor and actuator technologies with the feasibility of integrating multiple systems, treatment and diagnosis have gained more interest in incorporating Magnetic Resonance Imaging (MRI) due to better soft-tissue contrast. In this paper, the authors report the development of the MR-based Cooperative Brachytherapy (CoBra) robot design for in-bore patient prostate intervention, in terms of diagnosis and treatment of localized cancers. The presented CoBra system is characterized by three main MR-compatible components: a suitable leg-support ensuring patient stabilization, a versatile robotized needle guide, and an automated implant driver to deposit precisely radioactive seeds. In fact, ergonomically in-bore needle placement is a challenging problem, whereas the CoBra robot aims to help in in-bore intra-operative intervention under closed-loop control based on imagery feedback. This feedback might be exploited judiciously for tracking online the biological target during changes after needle insertions. Within this framework, the paper discusses the CoBra robot with a focus on kinematics design, modeling, instrumentation, control, and MRI in-bore robot tests, with respect to the adopted clinical workflow. Also, Preliminary experimental results simulating an adaptive prostate LDR-BT under 3 Tesla MRI are given to validate the proposed concept.
- 23 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 4 (3) , 667-681
Cooperative Brachytherapy Robotic Concept for Localized Cancer Treatment Under Real-Time MRI
Currently, localized cancer treatment is one of the focused research interests of Physicians. Indeed, with the advent of sensor and actuator technologies with the feasibility of integrating multiple systems, treatment and diagnosis have gained more interest in incorporating Magnetic Resonance Imaging (MRI) due to better soft-tissue contrast. In this paper, the authors report the development of the MR-based Cooperative Brachytherapy (CoBra) robot design for in-bore patient prostate intervention, in terms of diagnosis and treatment of localized cancers. The presented CoBra system is characterized by three main MR-compatible components: a suitable leg-support ensuring patient stabilization, a versatile robotized needle guide, and an automated implant driver to deposit precisely radioactive seeds. In fact, ergonomically in-bore needle placement is a challenging problem, whereas the CoBra robot aims to help in in-bore intra-operative intervention under closed-loop control based on imagery feedback. This feedback might be exploited judiciously for tracking online the biological target during changes after needle insertions. Within this framework, the paper discusses the CoBra robot with a focus on kinematics design, modeling, instrumentation, control, and MRI in-bore robot tests, with respect to the adopted clinical workflow. Also, Preliminary experimental results simulating an adaptive prostate LDR-BT under 3 Tesla MRI are given to validate the proposed concept.
- 27 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 4 (2) , 300-310
A Bio-Inspired Active Prostate Phantom for Adaptive Interventions
In this paper, a novel concept for a phantom of the prostate is introduced. To study and improve automated, robotized medical interventions, reliable phantoms are essential. During brachytherapy and biopsy, the prostate will undergo displacements and changes in orientation due to the needle insertion. Therefore, there is a shift in the target regions for radioactive seed deposition or biopsy acquisition. These shifts need to be taken into account for precise dosimetry. Furthermore, the organ can undergo deformations due to edemas causing further spatial changes in the target structure. Therefore, in this paper, we propose a bio-inspired phantom (BIP) for the prostate that is equipped with sensors and coupled with a numerical simulation for estimating deformations due to external forces. There is also a cavity within the phantom where pressure can be applied to simulate prostate growth due to inflammation. The phantom has been conceived to be MRI-safe. It can thus be deployed for the in-bore study of automated brachytherapy and biopsy. In our evaluation, we verify that changes in position of the phantom target can be correctly estimated and that these motions are plausible from a clinical point of view.
- 27 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 4 (2) , 300-310
A Bio-Inspired Active Prostate Phantom for Adaptive Interventions
In this paper, a novel concept for a phantom of the prostate is introduced. To study and improve automated, robotized medical interventions, reliable phantoms are essential. During brachytherapy and biopsy, the prostate will undergo displacements and changes in orientation due to the needle insertion. Therefore, there is a shift in the target regions for radioactive seed deposition or biopsy acquisition. These shifts need to be taken into account for precise dosimetry. Furthermore, the organ can undergo deformations due to edemas causing further spatial changes in the target structure. Therefore, in this paper, we propose a bio-inspired phantom (BIP) for the prostate that is equipped with sensors and coupled with a numerical simulation for estimating deformations due to external forces. There is also a cavity within the phantom where pressure can be applied to simulate prostate growth due to inflammation. The phantom has been conceived to be MRI-safe. It can thus be deployed for the in-bore study of automated brachytherapy and biopsy. In our evaluation, we verify that changes in position of the phantom target can be correctly estimated and that these motions are plausible from a clinical point of view.
- 14 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 3 (3) , 583-605
Review of Clinical and Technological Consideration for MRI-Guided Robotic Prostate Brachytherapy
Low Dose Rate Brachytherapy (LDR-BT) is a technique for treating localized prostate cancer by implanting radioactive seeds. In conventional practice, the delivery of seeds is performed using transrectal ultrasonography (TRUS) imaging for implant guidance and checked using computed-tomography for post-implant dosimetry. In the case of TRUS, accuracy can be compromised due to sub-optimal imaging. Magnetic Resonance Imaging (MRI), however, is known to provide better soft-tissue contrast, therefore, increasing the ability to detect small lesions; for that reason, the integration of intraoperative MRI in BT workflows has been investigated over the last two decades. The fusion of preoperative MR-images during TRUS-brachytherapy is possible. However, the image registration process introduces a source of uncertainty. Manual, real-time intra-operative LDR-BT is challenging under MRI due to confined space and procedural workflows. This motivates the development of MRI-compatible robots for prostate BT, with potential advantages of improved source placement accuracy and final dosimetry. In this paper, the state-of-art of technological components in MRI compatible robots, especially for LDR-BT, has been presented. This systematic review helps us to position an ongoing Cooperative Brachytherapy project, developing a real-time MRI-guided robot for adaptive LDR-BT. The design approach includes integrating separate modules: imaging, dose planning, needles, and robot.
- 14 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 3 (3) , 583-605
Review of Clinical and Technological Consideration for MRI-Guided Robotic Prostate Brachytherapy
Low Dose Rate Brachytherapy (LDR-BT) is a technique for treating localized prostate cancer by implanting radioactive seeds. In conventional practice, the delivery of seeds is performed using transrectal ultrasonography (TRUS) imaging for implant guidance and checked using computed-tomography for post-implant dosimetry. In the case of TRUS, accuracy can be compromised due to sub-optimal imaging. Magnetic Resonance Imaging (MRI), however, is known to provide better soft-tissue contrast, therefore, increasing the ability to detect small lesions; for that reason, the integration of intraoperative MRI in BT workflows has been investigated over the last two decades. The fusion of preoperative MR-images during TRUS-brachytherapy is possible. However, the image registration process introduces a source of uncertainty. Manual, real-time intra-operative LDR-BT is challenging under MRI due to confined space and procedural workflows. This motivates the development of MRI-compatible robots for prostate BT, with potential advantages of improved source placement accuracy and final dosimetry. In this paper, the state-of-art of technological components in MRI compatible robots, especially for LDR-BT, has been presented. This systematic review helps us to position an ongoing Cooperative Brachytherapy project, developing a real-time MRI-guided robot for adaptive LDR-BT. The design approach includes integrating separate modules: imaging, dose planning, needles, and robot.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Cooperative Brachytherapy for Prostate Cancer Under MRI Guidance
Prostate Cancer is one of the most prevalent cancers in men and a leading cause of death. Prostate Brachytherapy (BT) is one of the promising treatment techniques. The use of BT techniques is made easier, thanks to the developments of associated imaging technologies like Ultrasound and Magnetic Resonance Imaging (MRI). MRI has the capacity to detect small lesions providing a wider scope of research and enabling better accuracy in BT treatments. In order to enhance the diagnosis of the prostate cancer and its treatment options in the 2 seas region, Europe, Interreg 2 Seas co-financed a European Union Project Cooperative Brachytherapy called CoBra. The aim of the CoBra project is to perform a robotized biopsy and BT under real-time MRI-guidance. The concept is under development such as the robot’s task should be achieved within the MRI-scanner without any repositioning of the patient.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Cooperative Brachytherapy for Prostate Cancer Under MRI Guidance
Prostate Cancer is one of the most prevalent cancers in men and a leading cause of death. Prostate Brachytherapy (BT) is one of the promising treatment techniques. The use of BT techniques is made easier, thanks to the developments of associated imaging technologies like Ultrasound and Magnetic Resonance Imaging (MRI). MRI has the capacity to detect small lesions providing a wider scope of research and enabling better accuracy in BT treatments. In order to enhance the diagnosis of the prostate cancer and its treatment options in the 2 seas region, Europe, Interreg 2 Seas co-financed a European Union Project Cooperative Brachytherapy called CoBra. The aim of the CoBra project is to perform a robotized biopsy and BT under real-time MRI-guidance. The concept is under development such as the robot’s task should be achieved within the MRI-scanner without any repositioning of the patient.