Tais Estrela
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Tais Estrela has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Felipe A. Medeiros
Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miami, Florida
4 shared publications Samuel I. Berchuck
Vision, Imaging, and Performance Laboratory, Duke Eye Center and Department of Ophthalmology, Duke University, Durham, North Carolina; Department of Statistical Science and Forge, Duke University, Durham, North Carolina
4 shared publicationsAtalie C. Thompson
Vision, Imaging and Performance Laboratory (VIP), Duke Eye Center and Department of Ophthalmology, Duke University, Durham, North Carolina, USA
3 shared publicationsCarla N. Urata
Vision, Imaging and Performance Laboratory (VIP), Duke Eye Center and Department of Ophthalmology, Duke University, Durham, North Carolina, USA
3 shared publications- Eduardo Bicalho Mariottoni
Department of Ophthalmology, Federal University of Sao Paulo, Sao Paulo, Brazil
3 shared publications Alessandro A. Jammal
Vision, Imaging and Performance Laboratory (VIP), Duke Eye Center and Department of Ophthalmology, Duke University, Durham, North Carolina, USA; Department of Ophthalmology, State University of Campinas, Campinas, Brazil
2 shared publications
Latest Publications
- 8 April 2023
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 6 (5) , 457-465
Intraocular Pressure and Rates of Macular Thinning in Glaucoma
- 8 April 2023
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 6 (5) , 457-465
Intraocular Pressure and Rates of Macular Thinning in Glaucoma
- 1 March 2020
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 211, 123-131
Human Versus Machine: Comparing a Deep Learning Algorithm to Human Gradings for Detecting Glaucoma on Fundus Photographs
- 1 March 2020
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 211, 123-131
Human Versus Machine: Comparing a Deep Learning Algorithm to Human Gradings for Detecting Glaucoma on Fundus Photographs
- Open Access
- 15 January 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-9
Quantification of Retinal Nerve Fibre Layer Thickness on Optical Coherence Tomography with a Deep Learning Segmentation-Free Approach
This study describes a segmentation-free deep learning (DL) algorithm for measuring retinal nerve fibre layer (RNFL) thickness on spectral-domain optical coherence tomography (SDOCT). The study included 25,285 B-scans from 1,338 eyes of 706 subjects. Training was done to predict RNFL thickness from raw unsegmented scans using conventional RNFL thickness measurements from good quality images as targets, forcing the DL algorithm to learn its own representation of RNFL. The algorithm was tested in three different sets: (1) images without segmentation errors or artefacts, (2) low-quality images with segmentation errors, and (3) images with other artefacts. In test set 1, segmentation-free RNFL predictions were highly correlated with conventional RNFL thickness (r = 0.983, P < 0.001). In test set 2, segmentation-free predictions had higher correlation with the best available estimate (tests with good quality taken in the same date) compared to those from the conventional algorithm (r = 0.972 vs. r = 0.829, respectively; P < 0.001). Segmentation-free predictions were also better in test set 3 (r = 0.940 vs. r = 0.640, P < 0.001). In conclusion, a novel segmentation-free algorithm to extract RNFL thickness performed similarly to the conventional method in good quality images and better in images with errors or other artefacts.
- 15 January 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-9
Open AccessQuantification of Retinal Nerve Fibre Layer Thickness on Optical Coherence Tomography with a Deep Learning Segmentation-Free Approach
This study describes a segmentation-free deep learning (DL) algorithm for measuring retinal nerve fibre layer (RNFL) thickness on spectral-domain optical coherence tomography (SDOCT). The study included 25,285 B-scans from 1,338 eyes of 706 subjects. Training was done to predict RNFL thickness from raw unsegmented scans using conventional RNFL thickness measurements from good quality images as targets, forcing the DL algorithm to learn its own representation of RNFL. The algorithm was tested in three different sets: (1) images without segmentation errors or artefacts, (2) low-quality images with segmentation errors, and (3) images with other artefacts. In test set 1, segmentation-free RNFL predictions were highly correlated with conventional RNFL thickness (r = 0.983, P < 0.001). In test set 2, segmentation-free predictions had higher correlation with the best available estimate (tests with good quality taken in the same date) compared to those from the conventional algorithm (r = 0.972 vs. r = 0.829, respectively; P < 0.001). Segmentation-free predictions were also better in test set 3 (r = 0.940 vs. r = 0.640, P < 0.001). In conclusion, a novel segmentation-free algorithm to extract RNFL thickness performed similarly to the conventional method in good quality images and better in images with errors or other artefacts.
- 9 November 2019
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 210, 19-25
Comparison of Short- And Long-Term Variability in Standard Perimetry and Spectral Domain Optical Coherence Tomography in Glaucoma
- 9 November 2019
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 210, 19-25
Comparison of Short- And Long-Term Variability in Standard Perimetry and Spectral Domain Optical Coherence Tomography in Glaucoma